De-211 Quick Install v2
De-211 Quick Install v2
Placement Options In addition to placing the DE-211 unit on a desktop or other horizontal surface, you may also make use of the DIN-Rail or Wall Mount options, as illustrated here.
Wall Mount
DIN-Rail
1. Overview
Welcome to Moxa NPort Express DE-211, a compact palm-sized data communication device that allows you to control RS-232/422/485 serial devices over a TCP/IP based Ethernet.
2. Package Checklist
Before installing NPort Express DE-211, verify that the package contains the following items: 1 NPort Express DE-211 Universal Serial Device Server Quick Installation Guide for DE-211 Power Adapter NPort Document & Software CD Product Warranty Optional Accessories NP21101 NP21102 NP21103 DK-35A RS-232 cable: (M) DB25 to (F) DB9; 30 cm RS-232 cable: (M) DB25 to (M) DB9; 30 cm DB25 terminal block kit for RS-422/485 For 35 mm DIN-Rail; includes 4 screws Reset ButtonPress the Reset button continuously for a. 3 sec to erase the password After 3 sec, the Ready LED will flash on/off every half second. Release the reset button at this time to erase the password. b. 10 sec to load factory defaults After 10 sec, the Ready LED will flash on/off every fifth of a second. Release the reset button at this time to load factory defaults. LED IndicatorsDE-211s top panel contains five LED indicators, as described in the following table. LED Name PWR Link Ready Serial Tx Serial Rx LED Color red off orange off green off green off orange off LED Function Power is on. Power is off, or power error condition exists. 10 Mbps Ethernet connection. Ethernet cable is disconnected, or has a short. NPort Server system is ready. NPort Server has malfunctioned. Serial data is being transmitted. Serial data is not being transmitted. Serial data is being received. Serial data is not being received.
DIP Switch Settings & Explanation The top panel of DE-211 contains the following table, which describes how to set up the serial port using the four DIP switches located on DE-211s rear panel. SW1 SW2 Serial Connection OFF OFF RS-232 ON Console ON ON Data OFF ON Comm ON SW3 SW4 Serial Interface Mode OFF ON OFF ON OFF ON OFF ON ON ON OFF OFF RS-232 RS-422 4-Wire RS-485 by RTS 4-Wire RS-485 ADDC 2-Wire RS-485 by RTS 2-Wire RS-485 ADDC
Notify your sales representative if any of the above items is missing or damaged.
3. Hardware Introduction
Switch SW1 controls the function of the serial port. Note that after changing the setting of SW1, DE-211 will reboot to initialize the new setting. You must wait a few seconds for the green Ready light to blink off and then on again, indicating that the function of the serial port has been changed. Switches SW2, SW3, and SW4 control the serial ports data communication Interface Mode. (Note that RTS stands for Ready To Send and ADDC stands for Automatic Data Direction Control.) Keep the following points in mind when setting the DIP switches: To use the serial port as an RS-232 console connection, such as when using MOXA PComm Terminal Emulator or HyperTerminal, set SW1 to the ON position. Some setup procedures can be carried out through a Telnet connection, during which data is transmitted through DE-211s Ethernet port. However, you must set SW1 to the OFF position to establish a Telnet connection.
P/N: 18020021121
RS-422 Wiring
7. Environmental Specifications
RS-232 Wiring Power requirements DC 12V to 30V, 150 mA (max.) at 12V 92 mA (max.) at 24V 260 mA (max.) at 5V (Power over Serial enabled) 0 55C 5 95% RH 90 100.4 22 mm 3.54 3.95 0.87 in 67 100.4 22 mm 2.64 3.95 0.87 in 15 KV ESD for serial port 1.5 KV for Ethernet FCC Class B, CE Class B, UL, CUL, TV
Operating temp. Operating humidity Dimensions (WDH) Dimensions (WDH) Surge protection Magnetic isolation Regulatory approvals
RS-485 Wiring
Copyright 2004 Moxa Technologies Co., Ltd. All rights reserved. Reproduction without permission is prohibited. Tel: +886-2-8919-1230 Fax: +886-2-8919-1231 www.moxa.com [email protected]