0% found this document useful (0 votes)
604 views13 pages

Nikum Automatic Circuit Reclosers

Nikum produces automatic circuit reclosers for distribution lines from 11kV to 33kV. Their reclosers use vacuum interrupters for fast, low-energy arc interruption and have a modular design requiring minimal maintenance. Reclosers can be controlled electronically using Nikum's control units, which allow programming various timing and operational settings. Nikum offers communication packages to enable remote operation and monitoring of reclosers.

Uploaded by

Rahul Yadav
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
604 views13 pages

Nikum Automatic Circuit Reclosers

Nikum produces automatic circuit reclosers for distribution lines from 11kV to 33kV. Their reclosers use vacuum interrupters for fast, low-energy arc interruption and have a modular design requiring minimal maintenance. Reclosers can be controlled electronically using Nikum's control units, which allow programming various timing and operational settings. Nikum offers communication packages to enable remote operation and monitoring of reclosers.

Uploaded by

Rahul Yadav
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 13

Range of our products

Switchgear and Protection Equipment Industrial Lubricants Flow Switch Insulators

NIKUM

Nikum Energy Control (I) Limited


Website Email Phone www.nikum.co.in [email protected] +91 8510024871/2/3

NIKUM CONTENTS
TITLE
Introduction

Automatic Circuit Recloser

PAGE NUMBER

Overview Features Range

Technology Review

4 4 4 5 5 6 6 7 7 8

Recloser Technology Vacuum Interruption Surge Protection Flashover Recovery

Construction Operation Electronic Control


Recloser Electronic Control Relay Control Unit

Drawings Accessories

9 10

Communication Package

Ratings And Specifications

11

NIKUM

Automatic Circuit Recloser

INTRODUCTION
Overview
Nikum strives to bring our customers the latest technology. Combined with superior performance, competitive pricing, and unparalleled service aimed at total customer satisfaction, our products are the natural choice for you. This is especially true of our feeder automation products, where years of knowledge and modular manufacturing techniques allow our PSN series vacuum reclosers and contactors to meet any need and schedule.

Features
Flexible mounting options, such as indoor
and outdoor with individually mounted poles.

Cast aluminum and stainless steel high voltage ensure the best weathering/corrosion performance

Solenoid Operation = no mechanically


charged components for added safety.

No oil or gas insulation = environmentally


friendly products.

Less moving parts = less maintenance. Compact designs provide easy installation
in substations.

Low profile control cabinet (LPCC) available


where compact, lightweight control cabinets are required.

Proven design rated for 10,000 full load


operations.

Composite Silicon insulation provides


industry leading reliability.

Range
(11kV-33kV)

PSN series for three phase operation. NECL-M series for single phase operation. NECL-X series for compact and lightweight applications.

NIKUM

Automatic Circuit Recloser

TECHNOLOGY REVIEW

Recloser Technology
As part of our initiative to stay a generation ahead, NIKUM has assembled the latest magnetic actuation technology, highest quality vacuum interrupters, and most durable insulating material into the most dependable, cost effective, and lowest maintenance solution for recloser products. The PSN and NECL series, all function using the advanced technology created by NIKUMs researchers, and engineers. The reclosing sequence can be adjusted according to the requirement.

Vacuum Interruption
NIKUM reclosers use vacuum as the interrupting medium. Vacuum interrupters provide fast, low-energy arc interruption with long contact and interrupter life, low mechanical stress, and maximum operating safety. With arc interruption taking place in a vacuum, contact and interrupter life are several times greater than with interruption in oil, virtually eliminating Interrupter maintenance.

NIKUM
Surge Protection
Best operating results are achieved when reclosers are protected with surge arresters. On line applications, arrester protection is recommended on both sides of a recloser. If protection is to be provided on one side

Automatic Circuit Recloser

Flashover Recovery
Flashovers occur when an object, usually wildlife, contacts energized parts of the equipment. The NIKUM recloser minimizes the effect of flashovers with remarkable physical resilience, arc-quenching properties, and a self-healing ability. NIKUM recloser can withstand the enormous forces experienced during faults without wholesale damage and allows reenergizing after external flashover

NIKUM

Automatic Circuit Recloser

Construction
In common with other reclosers, Type NIKUM reclosers are designed for long service life with minimum maintenance. The recloser head is an aluminum/steel casting. The tank is fabricated of heavy -gauge steel and is finished with a corrosion-inhibitingepoxy prime coat, followed by a finish coat of thermosetting decal paint. Finish color is light gray. The recloser head is attached to a welded angle- and channel-steel box frame which facilitates handling and mounting. The tank is suspended within the box frame from the head. Each interrupter is independently suspended from the internal mechanism under the recloser head in a way which eliminates mechanical stress on the bushings as well as any need for adjustment between the bushing and interrupter. Silicon bushings are provided for flexible mounting options. Two targets, embedded on the recloser body, provide continuous (easily readable) indications of contact position and recloser state. Contact position indication is either CLOSED (white letters on red background) or OPEN (white letters on green background). A four-stage auxiliary switch is provided as standard. Normally set for four a and four b contacts, the switch can be programmed for other a and b combinations totaling eight. It is operated by the recloser mechanism and is wired to a terminal block in the operator cabinet.The switch can be used to provide a remote indication of contact position or to switch other devices, such as alarm circuits, coincidentally with recloser contact opening and closing.

Operation
Tripping
Line current in all three phases is sensed by 1000:1 ratio current transformers on bushings 1, 3, and 5 under the recloser head. Continuous signals from the CTs, proportional to line currents, are routed to the recloser control, where they are monitored. When the line current flows in excess of the programmed minimum trip level, in one or more phases, and after a time delay based on the programmed time current characteristic, a trip solenoid in the operating mechanism is energized by the electronic control (240V AC). The solenoids pull a shaft coupled with the vacuum interrupters that provide enough force for the interrupters to break the contact. A linkage simultaneously operates all three phases, opening the recloser contacts and a switch which interrupts the trip signal. from the control. During the process of tripping the shaft gets locked in the end position by a automatically adjusting self locking device. Once the recloser is tripped, the supply to the solenoids are cut-off to save energy by a limit switch.

Closing
As with contact opening, contact closing force is provided through the release of closing solenoids. The closing solenoids are charged by 240 V AC supply fed through contactors. Upon receiving a closing signal from the control, a solenoid energizes, overcoming the forces exerted by the locking mechanism. When released from the lock, the solenoids cause the operating mechanism to close the vacuum interrupter contacts. Limit switches interrupt the supply to the solenoids and the signal from the control when the recloser is closed to save energy.

NIKUM
Recloser Electronic Control
Nikum recloser is electronically controlled by a recloser control unit. The relay offers a choice of two controls that can be used in conjunction with this recloser. The control unit, is a solid-state electronic control system, using conventional, discrete, electronic components. Control operating parameters are programmed via plug-in modules. These programming components provide precise values for operating parameters, which include: time-current characteristics, reclosing delay intervals, and minimum trip levels. The control provides simple selector switch determination of phase and ground-trip sequences and operations to lockout. Operating characteristics and be quickly and easily changed, to meet new application requirements, by simply changing the dial settings or plug-in component(s), without removing the recloser from service. The relay control can be equipped with a variety of accessories to provide remote operation and monitoring for SCADA applications. Some of the available accessories include: remote fault indication, remote modification of operating characteristics, and remote operation.

Automatic Circuit Recloser

NIKUM
Relay Control Unit
Local human-machine interface
Simple menu-driven programming using large six-button keypad. Backlit display indicates metering values, fault information and location.

Automatic Circuit Recloser

Temperature compensated - operating temperature range: -40 F (-40 C) to +158 F (+70 C) Two levels of password-protected settings and controls.

Indicator lights
Continual self-checking with status indication. Pickup and lockout indication. User programmable LEDs for alarms, additional targets, etc.

Front mounted RS-232 port


Independent from rear mounted RS-232 port. Easy download and upload of data on-site using windows compatible software.

NIKUM
Drawings

Automatic Circuit Recloser

Control Panel

Recloser Architecture

Mounting Details 9

NIKUM
Accessories
Communications Packages Nikum can package reclosers with communications packages for a variety of protocols and transfer methods. NIKUM supported protocols include: DNP 3.0 Level 2 MODBUS ASCII Cellular/ Telemetry Interface: For operation of recloser through cellular mobile phone. Ethernet Hub

Automatic Circuit Recloser

Bluetooth
Stay out of the weather with the RN-220XP adapter for communication with your Nikum reclosers. Provides wireless connection to relay. Supports DNP 3.0 and MODBUS protocols. Built-in lithium ion battery (1.1AH) provides up to 32 hours of continuous operation. Secure Spread Spectrum Communication Adapter available for laptops without Bluetooth

Effortlessly multiplex up to 6 reclosers from one location. The 12A03054H01 ethernet hub has many benefits and features: Ideal for substation applications Does not require much space or complicated rack mounts Supports DNP 3.0 and MODBUS protocols Supports a variety of TCP/IP features Supports one RS-232 and four RS-485 ports 40 MHz processor

REMOTE CONTROL & MONITORING


When used with a compatible Distribution Automation System (DSA) Nikum pole mounted reclosers support remote controlling and monitoring to provide the following advantages: Information on reclosure status and fault current values transmitted to system control allows fast operation of the faulted line section, reducing the travelling time of line crews. This same information allows informed remote switching which reduces the affected area and quickly restores supply. Reclosers can be configured and settings managed from system control, without technicians having to visit each individual reclosure in the field, with a consequent reduction in staffing and improved system integrity.

Supported communications include:

Wi-Fi, cellular, radio,


Ethernet, SCADA, and 900/1800/2100 MHz spread spectrum.

Bluetooth

Ethernet 10

Cellular

NIKUM
Ratings And Specifications
Rated Voltage
Maximum Voltage Rated Basic Impulse Level Radio Noise Limit (V) Power Frequency Withstand (Dry) Power Frequency Withstand (Wet) Rated Continuous Current Short Circuit Current Withstand, Symmetrical Making Current, Asymmetrical Cable Charging Current Weight- Recloser (kg) Weight Control Cabinet (kg) Maximum Interrupting Time (ms) Maximum Closing Time Current Transformer Control Voltage

Automatic Circuit Recloser

11Kv
12kV 110kV [email protected] 55kV

12.5kV
15kV 125kV [email protected] 55kV

25kV
27kV 150kV [email protected] 60kV

33kV
36kV 170kV 100@24kV 75kV

50kV

50kV

55kV

70V

400 1600 A 12.5-40 kA

400-1600 A 12.5-40 kA

400-1250 A 12.531.5kA

400-1250 A 12.5-31.5 kA

31 kA 10 A 76-122 24 58

31 kA 13 A 85-130 24 60

31 kA 22 A 165-210 35 48

31 kA 24 A 180-320 35 46

60

60 One per phase 120/240 V AC

56

56

Creepage Distance (mm)


Terminal to ground Lower terminal to ground/ earth

11kV
950 660

12.5kV
950 680

25kV
1060 950

33kV
1060 970

11

NIKUM Testing And Standard


Testing

Automatic Circuit Recloser

The NEC-PSN circuit-breakers have undergone the tests indicated below and guarantee the safety and reliability of the apparatus in service in any installation: Type tests: heating, withstand insulation at power frequency, withstand insulation at

lightning impulse, short-time and peak withstand current, mechanical life, short-circuit
current making and breaking capacity. Individual tests: insulation of the main circuits with voltage at power frequency, auxiliary circuit and operating mechanism insulation, measurement of the main circuit resistance, mechanical and electrical operation.

Standard

GB/T 11022, IEC 60694 and DIN VDE 0670 part 100, "Common specifications for high voltage switchgear and control gear standards".

GB 1984 and IEC 62271-100 , "High-voltage alternating-current circuit-breakers". DIN VDE 0141, earthing systems for special power installations with rated voltages over 1 kV. IEC 61936, Electrical devices with rated voltage above AC 1 kV. PC37.60 - IEC/IEEE Draft International Standard for Automatic Circuit Reclosers and Fault In-

terrupters for Alternating Current Systems Up to 38 kV.

12

We at Nikum manufacture switchgear & protection equipment. We provide electric power optimization which include services such as Power Factor Correction, Harmonic Filtering etc. Some of our products:

Head Office
Address Plot No-29,D Block, Phase A-2, UPSIDC Industrial Ghaziabad, Uttar Pradesh, India Pincode 201102 Contact +91 8510024 871/2/3 ; +91 9350 139 227 E-mail [email protected] ;

Automatic Circuit Recloser Vacuum Circuit Breaker HT Fuse(33/11 kV) HRC Fuse Protection Fuse Semi-Conductor Fuse Crane Master Control Distribution Panel APFC Panel Wire Rope Compound Flow Switch Clamps Hosepipe Capacitor Bank Clamp & Nut Bolts Mica Insulator Epoxy insulators Super Charge Resin

Branch Office
Jamshedpur, Jharkhand Address Parmanu Nagar, Kandra Road , Behind Sri Ram Ranta, Adityapur, Jamshedpur, Jharkhand Pincode 831013 Contact +91 9304 321 564

Durgapur, West Bengal


Address tre, Contact Durgapur, West Bengal. +91 9474 600 889 54,Malhar North Avenue, Bengal Ambuja City Cen-

For any further details,please visit: www.nikum.co.in or E-mail at [email protected]; [email protected]; As an initiative towards environment safety most of the products at Nikum are designed to be built through the raw materials which are recyclable and environment friendly.

You might also like