Flexicon Hazardous Area Applications Why use Conduit over Cable?
Routing of cables, both electrical and data in hazardous areas, can be a complex task requiring detailed planning.
In summary, using a Flexicon conduit system with a Flameproof Barrier Gland can provide the following benefits over cable:
Simplified termination and greater enclosure integrity Reduced installation time - less terminations Cable is mechanically protected
SWA
's
No need for specialist cables Can provide EMC screening (braided versions) No need for use of SWA cables
Flameproof integrity
Future proofing the installation - easier to upgrade
KG
Ex d requirements insist that cable used in hazardous areas should be a considerably compact circular cable with extruded bedding and using fillers that are non-hygroscopic. Further more, thought should be given to the volume of cable required and how it will be terminated. If numerous cables are to be terminated at the same point, the size of glanding panel may impact on the required control box enclosure size. Using Flexicon conduit systems removes these issues as cables can be run through a protective conduit, allowing multi-cores to share the same space and so reduce the number of entry points required into the control box. Calculating the cross-sectional area of the cables to be run through a single conduit will enable the correct specification and selection of conduit system required.
Hazardous Area Applications
As a progressive organisation, Flexicon are continually investing in new product development to ensure superior cable protection in safety critical and hazardous areas. With a reputation for manufacturing innovation and excellence, Flexicon operate and are accredited to ISO9001 2008 British Standards and BS EN IEC 61386 Worldwide Standard for conduit systems. Flexicons EXD glands have been tested and accredited by SIRA to both ATEX and IECEx Ex d, Ex e and Ex ta applications and also have GOST approval.
Hazardous Area Approvals - now featuring Group 1 approvals
The following table provides further information and details on our ATEX, IECEx and GOST approvals for our straight EXD glands.
Group I
ATEX APPROVAL to EN60079-0 2009 Ex d Flameproof Ex e Increased Safety
Sira Certificate no: Ex d I Mb Ex e I Mb
Sira 10ATEX1172X EN 60079-1 2007 EN 60079-7 2007 IECEx SIR 10.0094X IEC 60079-1 2007 IEC 60079-7 2006-7 Sira 10ATEX1172X EN 60079-1 2007 EN 60079-7 2007 IEC 60079-31 2008
IECEx APPROVAL to IEC60079-0 2007 Sira Certificate no: Ex d Flameproof Ex d I Mb Ex e Increased Safety Ex e I Mb ATEX APPROVAL to EN60079-0 2009 Ex d Flameproof Ex e Increased Safety Ex ta Dust Ignition Proof Sira Certificate no: Ex d II C Gb Ex e II C Gb Ex ta IIIC DA IP6X
Group II
IECEx APPROVAL to IEC60079-0 2007 Sira Certificate no: IECEx SIR 10.0094X Ex d Flameproof Ex d II C Gb IEC 60079-1 2007 Ex e Increased Safety Ex e II C Gb IEC 60079-7 2006-7 Ex ta Dust Ignition Proof Ex ta IIIC DA IP6X IEC 60079-31 2008 GOST APPROVAL no. POCC GB.HO06.B00207
04
www.flexicon.uk.com
Flexicon Hazardous Area Classifications & Zones
Introduction
Hazardous Areas exist where a flammable mixture of gas and air, or dust and air, can exist in large enough quantities and for long enough periods to create a risk of explosion if an ignition source is present. Wherever possible it is important to minimise the risk of explosive mixtures forming and / or the risk of ignition. In the instances where this is impossible or impractical then means of providing a level of protection are required. This guide will briefly explain how people and plant can be protected in hazardous areas. The guide is particularly focussed towards applications for the Flexicon EXD conduit gland and is not intended to be a full guide to hazardous areas. Users of this conduit gland should be fully qualified, competent and conversant with hazardous area requirements.
ZONE
ZONE 2
ZONE 0
ZONE 1
ZONE 1 ZONE 0
Combustible Dust Hazards
IEC 61241 - Electrical apparatus for use in the presence of combustible dust.
ZONE
Flammable mixtures & Ignition Sources
ZONE
ZONE
21
Flammable gases when mixed with air can be explosive. Gases are categorised into 3 groups with Group A being the least explosive and Group C being the most explosive. Equipment is also classified from T1 to T6 according to maximum allowed ZONE ZONE ZONE ZONE temperature of the equipment to prevent ignition of the gas/air 0 1 2 21 mixture it is designed to work in. Certain fine dusts dispersed in air can also be explosive. Ignition sources include: sparking due to static discharge, electrical arcs, lightning, hot engine exhaust, hot equipment and heat from chemical reactions.
Zone 21 ZONE An22 area, in which combustible dust, as a cloud, is occasionally present during normal operation, in sufficient quantity to be capable of producing an explosive concentration of combustible dust in a mixture with air. Zone 22 An area, in which combustible dust, as a cloud, may occur infrequently and persist for only a short period, or in which accumulations of layers of combustible dust may give rise to an explosive concentration of combustible dust in a mixture with air.
ZONE
22
Hazardous Area Zones
The level of risk in hazardous areas is defined by a zoning system.
ZONE
0 1
Zone 0 ZONE ZONE ZONE ZONE An area where an explosive gas atmosphere 1 2 21 22 is present continuously or for long periods of time. Zone 1 ZONE ZONE ZONE An 2 area where 21 an explosive gas atmosphere may exist 22 under normal operating conditions. Zone 2 ZONE ZONE An area an explosive gas atmosphere is not likely 21 where 22 to exist under normal operating conditions, but if it does it will exist only for a short period of time.
Flexicons EXD barrier glands range can be used in Zone 1 and Zone 2 areas where Group A, B or C gases are present. As the gland does not add to the temperature of the enclosure, it does not have a temperature classification and so can be used with all temperature classes. Flexicons EXD barrier glands can be used in Zone 21 and Zone 22 where explosive dust may be present.
Anti-Static Applications
Clause 7.4 of EN60079-0 refers to the avoidance of a build-up of electrostatic charge on Group I or Group II electrical equipment. Electrical equipment shall be so designed that under normal conditions of use, maintenance and cleaning, danger of ignition due to electrostatic charges shall be avoided. This requirement is satisfied by suitable selection of the material so that surface resistance complies with either of the limits given below when measured in accordance with 26.13; 109 measured at (50 5) % relative humidity; or 1011 measured at (30 5) % relative humidity.
ZONE
0 1
ZONE
ZONE
ZONE
05
Flexicon Liquid Tight Flexible Conduit Range
With a choice of 11 different conduit types and fittings that provide the highest Ingress Protection rating IP69K, you can be sure your installation is Liquid Tight not just for now, but for many years to come!
High level of mechanical protection is paramount in arduous environments such as oil and gas, mining and other industrial installations. Flexicon Liquid Tight conduit and fittings offer a true heavy duty conduit and IP69K liquid tight solution for indoor or outdoor cable installations offering hard wearing solutions thus minimising production downtime.
EXD Liquid Tight Fittings
IP40 IP40
IP54 IP54
IP65 IP65
IP66 IP66
IP67 IP67
IP68 IP68
IP69K IP69K
These ttings can be used with Liquid Tight Conduits
Liquid tight conduit range Conduit
Core material Outer sheath Size Range Temperature Range IP Rating Tensile Strength* Compression Strength* Min Inside Bend Radius* Colours UV Resistant Oil Resistance Fire performance Applications Anti-Static Option Additional Approvals
LOW FIRE HAZARD
STANDARD
LOW FIRE HAZARD
EXTRA
LOW FIRE HAZARD
INHERENT
LTP/LTPAS
Galvanised Steel PVC / Anti-Static PVC 10mm to 63mm -20C.+105C IP66 + IP67 + IP68 (5 bar) + IP69K 130kg 400kg 65mm Black, Grey, Orange Yes Yes Self Extinguishing Oil resistance Yes (LTPAS) Lloyds Register of Shipping
LTPHC
Galvanised Steel Thermoplastic Elastomer (TPE) 12mm to 63mm -60C .+150C IP66 + IP67 + IP68 (5 bar) + IP69K 130kg 400kg 65mm Black Yes Yes Self Extinguishing & Halogen Free Low / High Temp -
LTPLFH
Galvanised Steel LFH Polyolen 16mm to 32mm -25C .+90C IP66 + IP67 + IP68 (5 bar) + IP69K 130kg 400kg 100mm Black Yes Yes Extra Low Fire Hazard & Self Extinguishing LFH London Underground
LTPUL
Galvanised Steel PVC 16mm to 63mm -15C.+75C IP66 + IP67 + IP68 (5 bar) + IP69K 160kg 500kg 90mm Black Yes Yes Self Extinguishing Dual listed UL Listed & CSA Approved
* Figures are representative for 20mm size
International Standards the peace of mind you should expect!
LFH encompasses LSF (low smoke and fume) and LSOH (low smoke zero halogen) Low Fire Hazard (LFH) conduit systems are becoming an increasing part of the specification in many cabling applications. Low Fire Hazard systems are required to protect personnel and property in the event of a fire and may be demanded by specifiers, occupiers, fire services or even insurers. Visit our website for more information.
LTPLFH
Self extinguishing Highly flame retardant Low smoke to BS6853 Low toxicity to BS6853 Classification to BS6853 London Underground Product Registration to 1-085 Halogen, Sulphur & Phosphorus free
LOW FIRE HAZARD
STANDARD
LOW FIRE HAZARD
EXTRA
LOW FIRE HAZARD
INHERENT
to EN 61386 LOI = 50% maximum opacity Ao = 0.01 R = 0.27 Cat 1a int and ext Certificate no. 2020
06
www.flexicon.uk.com
Flexicon Whatever your application we've got it covered!
Liquid Tight Fittings
IP40 IP40
IP54 IP54
IP65 IP65
IP66 IP66
IP67 IP67
IP68 IP68
IP69K IP69K
IP40 IP40 Steel IP54 IP54 IP65 IP65 Liquid Tight Stainless
IP66 IP66
IP67 IP67
IP68 IP68
IP69K IP69K
These ttings can be used with Liquid Tight Conduits
These ttings can be used with Liquid Tight Conduits
STANDARD
SCREEN
EMC
ENHANCED
SCREEN
EMC
SCREEN SCREEN
EMC EMC
SUPER STANDARD
LOW FIRE EMC HAZARD SCREEN
ENHANCED STANDARD
LOW FIRE EMC HAZARD SCREEN
EXTRASUPER
LOW FIRE EMC HAZARD SCREEN
INHERENT
STANDARD
ENHANCED
SCREEN
EMC
SCREEN
EMC
SUPER
LTPPU/LTPPUAS
Galvanised Steel Polyurethane / Anti-Static PU 10mm to 63mm -40C.+80C IP66 + IP67 + IP68 (5 bar) + IP69K 130kg 400kg 65mm Blue, Black Yes Yes Self Extinguishing & Halogen Free Abrasion resistance Yes (LTPPUAS) -
LTPSS
Stainless Steel (316) PVC 16mm to 50mm -20C.+105C IP66 + IP67 + IP68 (5 bar) + IP69K 130kg 400kg 65mm Black Yes Yes Self Extinguishing Corrosion resistance -
LTBRDP
Galv Steel / Galv Steel Braid PVC 20mm to 50mm -20C.+105C IP66 + IP67 + IP68 (5 bar) + IP69K 130kg 400kg 65mm Black Yes Yes Self Extinguishing EMC screened -
LTBRDLFH
Galv Steel / Galv Steel Braid LFH Polyolen 20mm to 32mm -20C.+90C IP66 + IP67 + IP68 (5 bar) + IP69K 130kg 400kg 130mm Black Yes Yes Extra Low Fire Hazard & Self Extinguishing EMC screening and LFH London Underground
LTPBRD
Galv Steel / TPE SS316 Overbraid 16mm to 50mm -60C.+150C IP66 + IP67 + IP68 (5 bar) IP69K 350kg 400kg 65mm Stainless Steel Yes Yes Self Extinguishing & Halogen Free Very arduous industrial environments As standard -
LTBRDLFH
Self extinguishing Highly flame retardant Low smoke to BS6853 Low toxicity to BS6853 Classification to BS6853 London Underground Product Registration to 1-085 Halogen, Sulphur & Phosphorus free
LOW FIRE HAZARD
STANDARD
LOW FIRE HAZARD
EXTRA
LOW FIRE HAZARD
INHERENT
EMC Screening Performance
Flexicon has classified EMC screening as follows
STANDARD STANDARD STANDARD ENHANCED ENHANCED ENHANCED SUPER SUPER SUPER
to EN 61386 LOI = 50% maximum opacity Ao = 0.01 R = 0.27 Cat 1a int and ext Certificate no. 658
SCREEN SCREEN SCREEN SCREEN SCREEN SCREEN SCREEN SCREEN SCREEN
EMC EMC EMCEMC EMC EMCEMC EMC EMC
Standard 50dB @ IMHz
Enhanced 60dB @ IMHz
Super 70dB @ IMHz
EMC screening performance charts are available on request. Contact Flexicon for further information.
Anti-Static Performance
Clause 7.4.2 of EN60079-0 refers to the avoidance of a build-up of electrostatic charge on Group I or Group II electrical equipment. Where necessary, Flexicon's AS ranges of products have been tested to and comply with this clause.
07
Flexicon Liquid Tight Conduit Galvanised Steel & Plastic Coated
LTP, LTPAS, LTPHC, LTPUL, LTPPU, LTPPUAS & LTPLFH
Galvanised Steel Core, Plastic Coated Liquid Tight
Conduit
LT P & LT P A S
Construction: Galvanised steel, helically wound, flexible conduit with smooth oil resistant and high temperature pvc cover. Colour black. Grey or orange on request. Special Characteristics: Oil resistant and self extiguishing. LTPAS version as above but with anti-static performance coating.
Properties
LT P H C
Construction: Galvanised steel, helically wound, flexible conduit with smooth thermoplastic elastomer (TPE) cover. Colour black. Special Characteristics: Wide temperature range performance. Good flexibility at low and high temperatures.
High mechanical strength IP rating: IP66 + IP67 + IP68 (5 bar) + IP69K Smooth, wipe clean outer cover Cover does not wrinkle when bent Temperature range -20C to +105C (LTP) -40C to +80C (LTPPU) -60C to +150C (LTPHC) -25C to +90C (LTPLFH) -15C to +75C (LTPUL) LTP has Lloyds Register Type Approval LTPUL conduits are UL listed and CSA approved Resistant to oils and greases Compliant to LUL Std 1-085-A3 (LTPLFH) Good flexibility (LTP, LTPAS, LTPHC, LTPUL, LTPPU & LTPPUAS) UV resistant and suitable for external use Nickel plated brass or stainless steel fittings Vibration and shock tested to EN61373 Cat 2 LTPAS & LTPPUAS have Anti-Static performace coating
LOW FIRE HAZARD
STANDARD
LOW FIRE HAZARD
EXTRA
LOW FIRE HAZARD
INHERENT
LT P U L
Construction: Galvanised steel, helically wound, flexible steel conduit including copper bonding strip (up to 40mm) with smooth pvc cover. Colour black. Special Characteristics: UL listed and CSA approved.
LT P P U & LTPPUAS
Construction: Galvanised steel, helically wound, flexible steel conduit with smooth halogen free polyurethane cover. Colour black (B) and blue (BU). (RAL 5015) Special Characteristics: Low temperature performance, high abrasion and high fatigue life. LTPPUAS version as above but with anti-static performance coating.
LT P L F H
Construction: Galvanised steel, helically wound, flexible conduit with smooth oil resistant Low Fire Hazard (LFH) cover. Colour black. Special Characteristics: As per LTP but where Extra Low Fire Hazard performance is required.
outside dia (mm)
US trade size ()
LT P P UA S
nominal size (mm)
inside dia (mm)
LT P H C
LT PA S
reel length (m) min inside bend radius (mm)
min inside bend radius (mm)
reel length (m) min inside bend radius (mm)
reel length (m) min inside bend radius (mm)
LT P L F H
LT P P U
LT P U L
min inside bend radius (mm)
min inside bend radius (mm)
reel length (m)
reel length (m)
part number
10 12 16 20 25 32 40 50 63
1 5 3 1 3
11.8 7.0 LTP10B+
part number
50
35 40
16 14.2 10.0 LTP12B 25, 50
8 17.8 12.6 LTP16B 10, 25, 50 45 2 21.1 16.0 LTP20B 10, 25, 50 65 4 26.4 21.0 LTP25B 10, 25, 50 100 135 175 230 280
1 33.1 26.5 LTP32B 10, 25 114 41.8 35.4 LTP40B 10, 25 112 47.9 40.4 LTP50B+ 10, 25 2 59.7 51.6 LTP63B+ 10, 25
LTPAS16B LTPAS20B LTPAS25B LTPAS32B LTPAS40B LTPAS50B+ LTPAS63B+
25 25 25 25 10 10 10
45 65 100 135 175 230 280
LTPHC12B LTPHC16B LTPHC20B LTPHC25B LTPHC32B LTPHC40B LTPHC50B+ LTPHC63B+
25 40 25 45 25 65 25 100 25 135 10 175 10 230 10 280
LTPUL16B LTPUL20B LTPUL25B LTPUL32B LTPUL40B LTPUL50B+ LTPUL63B+
25 25
50 90
25 110 15 140 15 180 15 230 15 280
LTPPU10 LTPPU12 LTPPU16 LTPPU20 LTPPU25 LTPPU32 LTPPU40 LTPPU50+ LTPPU63+
25 35 25 40 25 45 25 65 25 100 25 135 10 175 10 230 10 280
LTPPUAS16 LTPPUAS20 LTPPUAS25 LTPPUAS32 LTPPUAS40 LTPPUAS50+ LTPPUAS63+
25 25
45 65
25 100 25 135 10 175 10 230 10 280
LTPLFH16B 25 60 LTPLFH20B 10, 25 100 LTPLFH25B 10, 25 130 LTPLFH32B 10 180
+ Double interlock section.
STANDARDS
Please note that some of the above products are made to order on request and may be subject to MOQ and lead time. Contact us for further details.
Technical Drawing
BS EN IEC 61386
08
Note: refer to conduit properties for applicable standards.
LTP , LTPAS, LTPHC, LTPUL, LTPPU, LTPPUAS & LTPLFH
min inside bend radius (mm)
reel length (m)
reel length (m)
part number
part number
part number
part number
part number
LT P
Flexicon Liquid Tight Conduit Stainless Steel & Galvanised
LTPSS system
Stainless Steel Core, PVC Coated Liquid Tight
LTPBRD system
Galv Steel Core, Thermoplastic Elastomer (TPE) Coated and Stainless Steel Overbraid
STANDARD
LTBRDP system
Galv Steel Core, Galv Steel Braid, PVC Coated Liquid Tight
STANDARD
LTBRDLFH system
Galv Steel Core, Galv Steel Braid, LFH Coated Liquid Tight
STANDARD
SCREEN
EMC
ENHANCED
SCREEN
EMC
SCREEN
EMC
SUPER
SCREEN
EMC
ENHANCED
SCREEN
EMC
SCREEN
EMC
SUPER
SCREEN
EMC
LOW EMC FIRE SCREEN HAZARD
ENHANCED STANDARD
LOW EMC FIRE SCREEN HAZARD
SUPER EXTRA
LOW FIRE HAZARD
INHERENT
Conduit
STANDARD
Properties
SCREEN
EMC
ENHANCED
SCREEN
EMC
SCREEN
EMC
SUPER
LTPSS
Construction: Stainless steel (316), helically wound, flexible conduit with oil resistant and high temperature pvc smooth cover. Colour black. Special Characteristics: Enhanced corrosion resistance performance.
LTPBRD
Construction: Galvanised steel, helically wound, flexible conduit with thermoplastic elastomer (TPE) cover (same as LTPHC) and stainless steel (grade-316) overbraid. Special Characteristics: EMC screening, antistatic performance.
STANDARD
High mechanical strength Good flexibility (LTPSS,LTPBRD, LTBRDP) IP rating: IP66 + IP67 + IP68 (5 bar) + IP69K Smooth, wipe clean outer cover Cover does not wrinkle when bent Resistant to oils and greases Temperature range: -20C to +105C (LTPSS & LTBRDP) -20C to +90C (LTBRDLFH) -60C to +150C (LTPBRD) Vibration and shock tested to EN61373 Cat 2 Provides EMC screening (LTBRDP , LTBRDLFH, LTPBRD) Compliant to LUL Std 1-085-A3 (LTBRDLFH) LTPBRD offers inherent Anti-Static performance properties
SCREEN
EMC
ENHANCED
SCREEN
EMC
SCREEN
EMC
SUPER
STANDARD
SCREEN
EMC
EMC LOW FIRE SCREEN HAZARD
ENHANCED STANDARD
EMC LOW FIRE SCREEN HAZARD
SUPER EXTRA
LOW FIRE HAZARD
INHERENT
LTBRDP
Construction: Galvanised steel, helically wound, flexible conduit with galvanised steel braid and oil resistant and high temperature pvc smooth cover. Colour black. Special Characteristics: Good flexibility and EMC screening.
LTBRDLFH
Construction: Galvanised steel, helically wound, flexible conduit with galvanised steel braid and smooth LFH cover. Colour black. Special Characteristics: EMC screening and Extra Low Fire Hazard Performance.
Technical Drawing
TECHNICAL DRAWING
LTPSS
outside dia (mm)
US trade size ()
nominal size (mm)
inside dia (mm)
min inside bend radius (mm)
min inside bend radius (mm)
LTBRDP
min inside bend radius (mm)
LTBRDLFH
LTPBRD
10 12 16 20 25 32 40 50
3 1 3
8 17.8 12.6 LTPSS16 2 21.1 16.0 LTPSS20 4 26.4 21.0 LTPSS25
25 25 25 10 10 10
45 65 100 135 175 230
1 33.1 26.5 LTPSS32 114 41.8 35.4 LTPSS40 112 47.9 40.4 LTPSS50
LTPBRD16B LTPBRD20B LTPBRD25B LTPBRD32B LTPBRD40B LTPBRD50B
25 25 25
45 65 100
min inside bend radius (mm)
reel length (m)
reel length (m)
reel length (m)
reel length (m)
LTPSS
part number
part number
part number
part number
25 120 10 140 10 180
LTBRDP20B LTBRDP25B LTBRDP32B LTBRDP40B LTBRDP50B
25
65 LTBRDLFH20B
25 130 25 200 25 270
LTPBRD
25 100 LTBRDLFH25B 25 120 LTBRDLFH32B 10 140 10 180
+ Double interlock section.
STANDARDS
Please note that some of the above products are made to order on request and may be subject to MOQ and lead time. Contact us for further details.
LTBRDP & LTBRDLFH
BS EN IEC 61386
www.flexicon.uk.com
09
EXD Conduit Glands Flameproof EXD Barrier Gland
Properties
IP Rating: IP66 + IP67 + IP68 (5bar) + IP69K Material: Nickel Plated Brass or Stainless Steel (316) Suitable for threaded entries Operating Temperature of gland -60C to +85C High mechanical strength Can be used with individual cores or oversheathed cable
Hazardous Area Liquid Tight Conduit Solutions
Can be used in Zone 1, Zone 2, Zone 21 and Zone 22 Hazardous areas when used with Flexicons Liquid Tight range of flexible conduits ATEX and IECEx Ex d (Flameproof) ATEX and IECEx Ex e (Increased Safety) ATEX and IECEx Ex ta (Dust Ignition Protection)
Standards
Hazardous Area Approvals Group I
ATEX APPROVAL to EN60079-0 2009 Ex d Flameproof Ex e Increased Safety Sira Certificate no: Ex d I Mb Ex e I Mb Sira 10ATEX1172X EN 60079-1 2007 EN 60079-7 2007 IECEx SIR 10.0094X IEC 60079-1 2007 IEC 60079-7 2006-7 Sira 10ATEX1172X EN 60079-1 2007 EN 60079-7 2007 IEC 60079-31 2008
0518
BS EN IEC 61386
IECEx APPROVAL to IEC60079-0 2007 Sira Certificate no: Ex d Flameproof Ex d I Mb Ex e Increased Safety Ex e I Mb ATEX APPROVAL to EN60079-0 2009 Ex d Flameproof Ex e Increased Safety Ex ta Dust Ignition Proof Sira Certificate no: Ex d II C Gb Ex e II C Gb Ex ta IIIC DA IP6X
Group II
IECEx APPROVAL to IEC60079-0 2007 Sira Certificate no: IECEx SIR 10.0094X Ex d Flameproof Ex d II C Gb IEC 60079-1 2007 Ex e Increased Safety Ex e II C Gb IEC 60079-7 2006-7 Ex ta Dust Ignition Proof Ex ta IIIC DA IP6X IEC 60079-31 2008 GOST APPROVAL no. POCC GB.HO06.B00207
IP40 IP40 IP54 IP54 IP65 IP65 IP66 IP66 IP67 IP67 IP68 IP68 IP69K IP69K
IP40 IP40
IP54 IP54
IP65 IP65
IP66 IP66
IP67 IP67
IP68 IP68
IP69K IP69K
LTP - EXD
Construction: Nickel Plated Brass fitting with a nylon seal and two part epoxy resin pack. Supplied in boxes of one, complete with instructions and gloves. Typical Applications: Flameproof barrier gland offering a high specification, high quality solution for Ex d, Ex e and Ex ta applications. IP rating: IP66 + IP67 + IP68(5bar) + IP69K
LTP - EXD - SS
Construction: Stainless steel (grade 316) fitting with a nylon seal and two part epoxy resin pack. Supplied in boxes of one, complete with instructions and gloves. Typical Applications: Flameproof barrier gland offering a high specification, high quality solution for Ex d, Ex e and Ex ta applications where additional corrosion resistance is required. IP rating: IP66 + IP67 + IP68(5bar) + IP69K
To fit nominal size (mm)
metric thread part number
NPT thread part number
To fit nominal size (mm)
metric thread part number
NPT thread part number
16 20 25 32 40 50 63
LTP16-M20-EXD LTP20-M20-EXD LTP25-M25-EXD LTP32-M32-EXD LTP40-M40-EXD LTP50-M50-EXD LTP63-M63-EXD
LTP16-050-EXD LTP20-050-EXD LTP25-075-EXD LTP32-100-EXD LTP40-125-EXD LTP50-150-EXD LTP63-200-EXD
16 20 25 32 40 50 63
LTP20-M20-EXD-SS LTP25-M25-EXD-SS LTP32-M32-EXD-SS LTP40-M40-EXD-SS LTP50-M50-EXD-SS LTP63-M63-EXD-SS
LTP20-050-EXD-SS LTP25-075-EXD-SS LTP32-100-EXD-SS LTP40-125-EXD-SS LTP50-150-EXD-SS LTP63-200-EXD-SS
USED WITH THE FOLLOWING CONDUITS:- as featured on pages 08 & 09
LTP / LTPAS
LTPHC
STANDARD
LTPLFH
LOW FIRE HAZARD LOW FIRE HAZARD
EXTRA
LTPPU / LTPPUAS
LOW FIRE HAZARD
INHERENT
LTPSS
10
Properties
IP Rating: IP66 + IP67 + IP68 (5 Bar) Material: Nickel Plated Brass Suitable for threaded entries Operating Temperature of gland -60C to +85C High mechanical strength Can be used with individual cores or oversheathed cable Can be used in Zone 1, Zone 2, Zone 21 and Zone 22 Hazardous areas when used with Flexicons Liquid Tight range of flexible conduits ATEX and IECEx Ex d (Flameproof) ATEX and IECEx Ex e (Increased Safety) ATEX and IECEx Ex ta (Dust Ignition Protection)
Hazardous Area Approvals
ATEX APPROVAL to EN60079-0 2006 Ex d Flameproof Ex e Increased Safety Ex ta Dust Ignition Proof IECEx APPROVAL to IEC60079-0 2004 Ex d Flameproof Ex e Increased Safety Ex ta Dust Ignition Proof GOST APPROVAL no. Sira Certificate no: SIRA 13ATEX1072X Ex d II C Gb Ex e II C Gb Ex ta IIIC DA IP6X Sira Certificate no: IEC Ex SIR13.0027X Ex d II C Gb Ex e II C Gb Ex ta IIIC DA IP6X POCC GB.HO06.B00207
IP66
IP67
IP68
IP66
IP67
IP68
LTP-EXD-90
Construction: 90 elbow, Nickel Plated Brass fitting with a nylon seal and two part epoxy resin pack. Supplied in boxes of one complete with instructions and gloves. Typical Applications: Flameproof barrier gland ideal for use when there is restricted space to terminate into an enclosure / equipment. IP rating: IP66 + IP67 + IP68 (5 bar)
LTP-EXD-45
Construction: 45 elbow, Nickel Plated Brass fitting with a nylon seal and two part epoxy resin pack. Supplied in boxes of one complete with instructions and gloves. Typical Applications: Flameproof barrier gland ideal for use when there is restricted space to terminate into an enclosure / equipment. IP rating: IP66 + IP67 + IP68 (5 bar)
To fit nominal size (mm)
metric thread part number
To fit nominal size (mm)
metric thread part number
16 20 25 32 40 50 63
LTP16-M20-EXD-90 LTP20-M20-EXD-90 LTP25-M25-EXD-90 LTP32-M32-EXD-90 LTP40-M40-EXD-90 LTP50-M50-EXD-90 LTP63-M63-EXD-90
16 20 25 32 40 50 63
LTP16-M20-EXD-45 LTP20-M20-EXD-45 LTP25-M25-EXD-45 LTP32-M32-EXD-45 LTP40-M40-EXD-45 LTP50-M50-EXD-45 LTP63-M63-EXD-45
Please note that some of the above products are made to order on request and may be subject to MOQ and lead time. Contact us for further details.
WEBSITE
LTPUL
LTBRDP
ENHANCED
LTBRDLFH
ENHANCED
SCREEN
EMC
SCREEN
EMC
LOW FIRE HAZARD
EXTRA
Checkout our website for further details on how to use our products. EMC www.flexicon.uk.com SCREEN
STANDARD
11
EXD Braided Conduit Glands Flameproof EXD Barrier Gland
Properties
IP Rating: IP66 + IP67 + IP68 (5bar) + IP69K Material: Nickel Plated Brass Suitable for threaded entries Operating Temperature of gland -60C to +85C High mechanical strength Can be used with individual cores or oversheathed cable Used with overbraided conduit system LTPBRD to achieve EMC screening Can be used in Zone 1, Zone 2, Zone 21 and Zone 22 Hazardous areas when used with Flexicons Liquid Tight range of flexible conduits ATEX and IECEx Ex d (Flameproof) ATEX and IECEx Ex e (Increased Safety) ATEX and IECEx Ex ta (Dust Ignition Protection)
Standards
Hazardous Area Approvals Group I
ATEX APPROVAL to EN60079-0 2009 Ex d Flameproof Ex e Increased Safety Sira Certificate no: Ex d I Mb Ex e I Mb Sira 10ATEX1172X EN 60079-1 2007 EN 60079-7 2007 IECEx SIR 10.0094X IEC 60079-1 2007 IEC 60079-7 2006-7 Sira 10ATEX1172X EN 60079-1 2007 EN 60079-7 2007 IEC 60079-31 2008
0518
BS EN IEC 61386
IECEx APPROVAL to IEC60079-0 2007 Sira Certificate no: Ex d Flameproof Ex d I Mb Ex e Increased Safety Ex e I Mb ATEX APPROVAL to EN60079-0 2009 Ex d Flameproof Ex e Increased Safety Ex ta Dust Ignition Proof Sira Certificate no: Ex d II C Gb Ex e II C Gb Ex ta IIIC DA IP6X
Group II
IECEx APPROVAL to IEC60079-0 2007 Sira Certificate no: IECEx SIR 10.0094X Ex d Flameproof Ex d II C Gb IEC 60079-1 2007 Ex e Increased Safety Ex e II C Gb IEC 60079-7 2006-7 Ex ta Dust Ignition Proof Ex ta IIIC DA IP6X IEC 60079-31 2008 GOST APPROVAL no. POCC GB.HO06.B00207
IP40 IP40
IP54 IP54
IP65 IP65
IP66 IP66
IP67 IP67
IP68 IP68
IP69K IP69K
LTPB - EXD
Construction: Nickel Plated Brass fitting with a nylon seal and two part epoxy resin pack. Supplied in boxes of one, complete with instructions and gloves. Typical Applications: Flameproof barrier gland offering a high specification, high quality solution for Ex d, Ex e and Ex ta applications. For use with external braided conduit systems where high mechanical protection and / or emc screening is required. IP rating: IP66 + IP67 + IP68(5bar) + IP69K
To fit nominal size (mm)
metric thread part number
NPT thread part number
20 25 32 40 50
LTPB20-M20-EXD LTPB25-M25-EXD LTPB32-M32-EXD LTPB40-M40-EXD LTPB50-M50-EXD
LTPB20-050-EXD LTPB25-075-EXD LTPB32-100-EXD LTPB40-125-EXD LTPB50-150-EXD
Please note that some of the above products are made to order on request and may be subject to MOQ and lead time. Contact us for further details.
Technical Drawing
USED WITH THE FOLLOWING CONDUITS:as featured on page 09
LTPB - EXD
LTPBRD
STANDARD
12
SCREEN
EMC
ENHANCED
SCREEN
EMC
SCREEN
EMC
SUPER
Flexicon EXD Accessories Range
With a comprehensive range of EXD accessories we can offer customers choice when it comes to specifying hazardous area approved equipment. Our products are manufactured in the UK and have been tested to the latest ATEX & IECEx standards. The standards are marked on the body of the product allowing visibility once installed.
Our range of thread converters are designed for both Industrial and Hazardous Area applications with Ex d, Ex e and Ex ta component approval. Available with male to female connection threads these products can be used to increase, reduce or convert the thread type.
Technical Data Design Specification ATEX Certification Detail ATEX Code of Protection Category ATEX Compliance Standards IEC Ex Certifcation Detail IEC Ex Compliance Standards Continuous Operating Temperature Ingress Protection Rating Materials Optional Accessories EN 50262:1989, BS 6121:Part 1:1989 SIRA01ATEX1284U, SIRA02ATEX1003X II 2 GD Ex d IIC & Ex e II - Component & Equipment, Zone 1, Zone ATEX 2, Zone 21, & Zone 22 - Gas Groups IIA, IIB, IIC, ATEX IM2 Ex d I, Ex e I EN 60079-0:2006, EN 60079-1:2004, EN 60079-7:2007, EN 50281-1-1:1998 IEC Ex SIR07.0052X IEC 60079-0:2004, IEC 60079-1:2003, IEC 60079-7:2006-07, IEC 61241-0:2004, IEC 61241-1:2004 -60C to +200C Up to IP68 when fitted with a suitable Sealing Washer Nickel Plated Brass Locknut, Serrated Washer, Earth Tag, Sealing Washer. See Page 15
IEC Ex Code of Protection Category Ex d I, Ex e I, Ex d IIC, Ex e II, Ex tD A21 IP6X
Thread Converters
Our thread converters are Nickel Plated Brass as standard.
Internal Metric to External Metric
Female Thread - Internal Male Thread External M16 M20 M25 M32 M40 M50
M16 M20 M25 M32 M40 M50 M63
B-M16-M20-EXD B-M20-M16-EXD B-M25-M20-EXD B-M32-M25-EXD B-M40-M32-EXD B-M50-M32-EXD B-M20-M25-EXD B-M25-M32-EXD B-M32-M40-EXD B-M50-M40-EXD B-M63-M40-EXD
B-M63-M50-EXD
Internal Metric to External NPT
Female Thread - Internal Male Thread External M25 M32 M40 M16 M20 M50
2 4 1
1 3
B-050-M20-EXD B-075-M20-EXD
B-075-M25-EXD B-100-M32-EXD
To obtain Adaptor & Reducer nominal dimensions, follow the steps below:Step 1 - Select male thread by consulting the left hand column of the table. Step 2 - Select the female thread size by consulting column headings at the top of tables, and by cross referencing this with the selection in step 1. Please note that the data in the tables above includes Adaptors and Reducers that are certified for use in Hazardous Areas.
www.flexicon.uk.com
13
Flexicon EXD Accessories Range
Designed to provide a permanent or temporary means of blanking unused cable entry holes in Flameproof enclosures enabling the equipment to be safely deployed in the Hazardous Area. Always inserted from the outside of the enclosure, we have a range of stopping plug options depending on the required installation method.
Allen Key
The Allen key stopping plugs can be installed or removed using an allen key. We offer standard stopping plugs or Dome Head type allen key stopping plugs. Technical Data - Standard & Dome Head Design Specification ATEX Certification Detail ATEX Code of Protection Category ATEX Compliance Standards IEC Ex Certifcation Detail IEC Ex Code of Protection Category IEC Ex Compliance Standards BS 6121:Part 1:1989, EN 50262:1999 SIRA01ATEX1284U, SIRA02ATEX1003X ATEX ATEX IM2 Ex d I, Ex e I; II 2 Ex d IIC, Ex e II
Hex Head
The Hex head stopping plugs can be installed or removed with a standard open ended or ring type spanner or wrench. Technical Data - Hex Head ATEX Certification Detail ATEX Code of Protection Category SIRA01ATEX1284U, SIRA02ATEX1003X II 2 GD Ex d IIC & Ex e II ATEX Component & Equipment, Zone 1, Zone 2, Zone 21, & Zone 22 Gas Groups IIA, IIB, IIC, ATEX IM2 Ex d I, Ex e I EN 60079-0:2006, EN 60079-1:2004, EN 60079-7:2007, EN 50281-1-1:1998 IEC Ex SIR07.0056X Ex d I / Ex e I / Ex d IIC / Ex e II, Ex tD A21 IP6X IEC 60079-0:2004, IEC 60079-1:2003, IEC 60079-7:2006-07, IEC 61241-0:2004, IEC 61241-1:2004 -60C to +200C Up to IP68 when fitted with suitable Sealing Washer Nickel Plated Brass Locknut, Serrated Washer, Earth Tag, Sealing Washer. See Page 15
EN 60079-0, EN 60079-7, EN 61241-0, EN 61241-1 IEC Ex SIR07.0056X Ex d I, Ex e I, Ex d IIC, Ex e II, Ex tD A21 IP6X IEC 60079-0:2004, IEC 60079-1:2003, IEC 60079-7:2006-07, IEC 61241-0:2004, IEC 61241-1:2004 -60C to + 200C IP66 Nickel Plated Brass Locknut, Serrated Washer, Earth Tag, Sealing Washer. See Page 15
ATEX Compliance Standards IEC Ex Certifcation Detail IEC Ex Code of Protection Category IEC Ex Compliance Standards
Continous Operating Temperature Ingress Protection Rating Materials Optional Accessories
Continous Operating Temperature Ingress Protection Rating Materials Optional Accessories
Stopping Plugs
Our stopping plugs are Nickel Plated Brass as standard.
Size Range
Standard
B-M16-SP-EXD B-M20-SP-EXD B-M25-SP-EXD B-M32-SP-EXD B-M40-SP-EXD B-M50-SP-EXD B-M63-SP-EXD
Dome Head
B-M16-DSP-EXD B-M20-DSP-EXD B-M25-DSP-EXD B-M32-DSP-EXD B-M40-DSP-EXD B-M50-DSP-EXD B-M63-DSP-EXD
Hex Head
B-M16-HSP-EXD B-M20-HSP-EXD B-M25-HSP-EXD B-M32-HSP-EXD B-M40-HSP-EXD B-M50-HSP-EXD B-M63-HSP-EXD
M16 M20 M25 M32 M40 M50 M63
14
www.flexicon.uk.com
Flexicon General Accessories
Metric Locknuts
Nickel plated brass, plated steel, stainless steel
Fixing Clips For Conduits
Plated steel with black pvc liner or stainless steel. Note: LFH liner available on request
stainless steel part number
nickel plated brass part number
nickel plated EMC part number
to fit conduit size (mm)
part number
plated steel part number
to fit thread
M20 M25 M32 M40 M50 M63
M20 M25 M32 M40 M50 M63
B-M20-EMC B-M25-EMC B-M32-EMC B-M40-EMC
S-M20 S-M25 S-M32 S-M40 S-M50 S-M63
SS-M20 SS-M25 SS-M32 SS-M40 SS-M50* SS-M63*
16 20 25 32 40 50 63
FCC16 FCC20 FCC25 FCC32 FCC40 FCC50 FCC63
FCC16-SS FCC20-SS FCC25-SS FCC32-SS FCC40-SS FCC50-SS *
* indicates parts made to order on request and may be subject to MOQ and lead time
Sealing Washers
Polyester Elastomer (PE), Neoprene and fibre face sealing washers PE - Retained Sealing Washer Neoprene Fibre Sealing Washer Sealing Washer Neoprene Fibre Sealing Washer Sealing Washer
Earthing Washers
Shake proof washer Earth tag washer
metric thread part number
metric thread part number
metric thread part number
to fit thread
to fit thread
M16 M20 M25 M32 M40 M50 M63
RSW16 RSW20 RSW25 RSW32 RSW40 RSW50
SW16 SW20 SW25 SW32 SW40 SW50 SW63
FW16 FW20 FW25 FW32 FW40 FW50 FW63
PG9 PG11 PG13 PG16 PG21 PG29 PG36 PG42 PG48
SWPG9 SWPG11 SWPG13 SWPG16 SWPG21 SWPG29 SWPG36 SWPG42 SWPG48
FWPG9 FWPG11 FWPG13 FWPG16 FWPG21 FWPG29 FWPG36 FWPG48
M20 M25 M32
to fit thread
SPW20 SPW25 SPW32
metric thread part number
PG thread part number
PG thread part number
ET-M20 ET-M25
metric thread part number
part number
www.flexicon.uk.com
15
Flexicon EXD Conduit Gland Installation Guide & Instructions
Barrier cable gland for use in hazardous areas with unarmoured cable or individual cores housed in Flexicon flexible conduit. Incorporating EC declaration of conformity to directive 94/9/EC
Conduit Gland Components
1. Entry Thread 2. Compound Tube 3. Washer 4. Conduit Insert 5. Conduit Seal 6. Compression Nut
NOTE: For LTPB-EXD and LTP-EXD-90 & 45 installation instructions visit our website for further information.
Installation instructions for Flexicon conduit gland type EXD
a
Please read all instructions carefully before beginning the installation a Disconnect the Compression Nut (6) and remove the Conduit Seal (5) and Conduit Insert (4) from the gland. Slide the nut over the conduit, followed by the conduit seal (orientated as shown below) and screw the conduit insert into place.
b Remove the Compound Tube (2), and Washer (3) as an assembly from the Entry Item (1). Feed the prepared cable/cable cores through the flexible conduit and through the compound tube/washer assembly.
Crutch of the cable
Remove the compound tube. If the installation involves a cable, remove any bedding or fillers from around the cable cores. If the cable cores have screens, these should be unravelled and then twisted together to form a single core. Wearing the protective gloves supplied, mix all of the two-part epoxy compound (EP2122) until it is pliable and an even colour is achieved. The minimum temperature when mixing is 10C. Ensure compound is within use-by date.
d Separate the cable cores and apply the compound to the crutch of the cable for a distance of about 6mm and pack into place. If a drain wire is present then it should be sleeved with some heat shrink tubing which is pushed into the compound before shrinking with the application of some heat. Screens that have been twisted together should be treated as a drain wire.
Remove surplus compound
e f
Bring the cores together again and pack more compound around them to a length and diameter sufficient to fill the compound tube, ending in a taper. Pass the Compound Tube (2) over the conductors until the stepped end is fully located with the Washer (3). Pack more compound into place until the compound tube is fully filled.
Ensure that compound does not overlap tube
16
www.flexicon.uk.com
g Re-install the conduit assembly into the entry item making sure the compound is not disturbed and loosely tighten the Compresson Nut (6) onto the Entry Item (1). When the compound has cured the entry item should be removed from the assembly and fitted to the apparatus. The gland can then be refitted into it and the Compression Nut (6) finally tightened. Typical cure times are shown opposite.
Flexicon EXD Conduit Gland Installation Guide & Instructions
Technical data and specification
Technical Data
CONDUIT GLAND TYPE : INGRESS PROTECTION : PROCESS CONTROL SYSTEM : EXD IP66, IP67, IP68 (5 Bar) & IP69K BS EN ISO 9001
Hazardous Area Approvals Group I
ATEX APPROVAL to EN60079-0 2009 Ex d Flameproof Ex e Increased Safety IECEx APPROVAL to IEC60079-0 2007 Ex d Flameproof Ex e Increased Safety ATEX APPROVAL to EN60079-0 2009 Ex d Flameproof Ex e Increased Safety Ex ta Dust Ignition Proof IECEx APPROVAL to IEC60079-0 2007 Ex d Flameproof Ex e Increased Safety Ex ta Dust Ignition Proof GOST APPROVAL no. Sira Certificate no: Ex d I Mb Ex e I Mb Sira Certificate no: Ex d I Mb Ex e I Mb Sira Certificate no: Ex d II C Gb Ex e II C Gb Ex ta IIIC DA IP6X Sira Certificate no: Ex d II C Gb Ex e II C Gb Ex ta IIIC DA IP6X POCC GB.HO06.B00207 Sira 10ATEX1172X EN 60079-1 2007 EN 60079-7 2007 IECEx SIR 10.0094X IEC 60079-1 2007 IEC 60079-7 2006-7 Sira 10ATEX1172X EN 60079-1 2007 EN 60079-7 2007 IEC 60079-31 2008 IECEx SIR 10.0094X IEC 60079-1 2007 IEC 60079-7 2006-7 IEC 60079-31 2008
Installation Instructions
Installation should only be performed by a competent person using the correct tools. Read all instructions before beginning installation.
1400 1200
Group II
Temperature Vs Cure Times
Special Conditions For Safe Use
1 The conduit gland ranges shall only be used where the temperature, at the point of entry, is in the following ranges: -60C to +85C. 2 The entry component threads may need additional sealing to maintain the ingress protection ratings as applicable to the associated equipment to which it is attached. See pages 9, 10 & 11 for accessory details.
Liquid Tight Conduit Size (mm) 16 20 25 32 40 50 63 Available Entry Threads A Standard Metric M20 M20 M25 M32 M40 M50 M63 Option NPT 1 1 1 2 Diameter Minimum Over Thread Conductors Length F B Max 15.0 15.0 15.0 15.0 15.0 15.0 15.0 10.7 12.6 17.5 23.6 30.0 36.6 47.9 Number of Cores Max 11 11 21 38 59 89 115 Across Flats E Max 30.0 30.0 36.0 46.0 52.0 60.0 70.0
TIme (Mins)
1000 800 600 400 200 0 0 5 10 15 20 25 30 35 40 45
Temperature (c)
E A/F
F
Cable Gland Selection Table
Across Nominal Corners Protrusion D Length C Max 29.0 29.0 35.0 42.0 52.0 58.0 70.0 32.0 32.0 35.0 37.0 38.0 40.0 40.0
Part No.
Cable Gland Weight (Kgs) 0.100 0.100 0.250 0.460 0.615 0.700 0.820
D A/F C B
LTP16-M20-EXD LTP20-M20-EXD LTP25-M25-EXD LTP32-M32-EXD LTP40-M40-EXD LTP50-M50-EXD LTP63-M63-EXD
All dimensions in millimetres (unless otherwise stated)
17
F o r m o r e i n f o r m a t i o n o n o u r F l e x i c o n f l e x i b l e c o n d u i t s o l u t i o n s , p l e a s e v i s i t w w w . e t s c c . c o . u k f o r m o r e i n f o r m a t i o n .
L i q u i d T i g h t F l e x i b l e C o n d u i t s
S t a i n l e s s S t e e l B r a i d e d F l e x i b l e C o n d u i t s
R a i l I n f r a s t r u c t u r e F l e x i b l e C o n d u i t s
H a z a r d o u s A r e a ( E X D ) F l e x i b l e C o n d u i t s
F l e x i b l e C o n d u i t F i t t i n g s a n d A c c e s s o r i e s
+ 4 4 ( 0 ) 2 0 8 4 0 5 6 7 8 9
s a l e s @ e t s c c . c o . u k
w w w . e t s c c . c o . u k