I Drive
I Drive
PDA cable
EDX-PDA
iDrive
AC variable speed economy drives
options and ordering codes
EDX - 075 iDrive Power (kW) 0.2 020 0.4 040 0.75 075 1.5 150 2.2 220 100v 200v 400v 600v 1 2 4 6 E 1 3 1Phase 3 Phase
0.2-2.2kW
E
N4 N4S
RS485
EDX-485
Example shown: EDX-075-43-E = 0.75kW, 400V, 3 phase with integrated EMC filter
RS232
EDX-232
Memory pack
EDX-MP
TE
side-by-side installation
TE
GUARAN
GUARAN
GUARAN
TE
programming options
space saving
Cam Switches Din Terminals Drives Enclosures Fieldbus remote I/O Isolators & Switch Fuses MCB & RCD Motor Circuit Breakers Motor Control Gear Panel Meters Relays Signal Conditioning Sockets Timers Transformers & Power Supplies
Drives Intelligent Terminals/HMI Limit Switches Photoelectric Switches PLCs Proximity Switches Temperature Controls
Data Acquisition & Control Drives Intelligent Terminals/HMI Limit Switches Photoelectric Switches Proximity Switches PLCs Signal Conditioning Temperature Controls
All IMO products are tried, tested and approved to relevant international quality standards
Audible devices Chip-on-Board Device programmers LEDs & 7 seg. displays PCB Terminal blocks Relays - automotive Relays - power Relays - signal Switches
YEA
YEA
YEA
specification
4 x 4.5 Special Order only 110V/1 Model data EDX-xxx-11 020 040 075 Horsepower (hp) 0.25 0.5 1 Nominal Motor Capacity (kW) 0.2 0.4 0.75 Rated Output Current (A) 1.7 3.1 4.2 Rated Capacity 0.53 0.88 1.60 Max. Input Voltage 1 100-120V +10%, -15% (50/60Hz) 0V Max. Output Voltage 3 / 0 to V input Input Current (A) 7.1 12.2 17.9 Net Weight (kg) 0.62 0.68 0.72 Allowable momentary power 1.0 1.0 1.0 loss time (second) Frame size (see dims) 1 1 1 Enclosure IP20 220V/1 EDX-xxx-21-E 040 075 150 0.5 1 2 0.4 0.75 1.5 3.1 4.2 7.5 0.88 1.60 2.90 1 200-240V +10%, -15% (50/60Hz) 3 / 0 to V input 5.4 10.4 15.5 0.73 0.73 1.25 1.0 1 1.0 1 IP20 2.0 2 Special Order only 220V/3 EDX-xxx-23 040 075 150 0.5 1 2 0.4 0.75 1.5 3.1 4.2 7.5 0.88 1.60 2.90 3 200-240V +10%, -15% (50/60Hz) 3 / 0 to V input 4.0 6.4 9.4 0.61 0.66 0.95 1.0 1 1.0 1 IP20 2.0 2 440V/3 EDX-xxx-43-E 075 150 220 1 2 3 0.75 1.5 2.2 2.3 3.8 5.2 1.7 2.9 4.0 3 380-480V +10%, -15% (50/60Hz) 3 / 0 to V input 3 4.8 6.6 1.68 1.7 1.73 1.0 2 2.0 2 IP20 2.0 2 Frame 1 Frame 2 A 67 108 B 77 118 C 130.5 148 D 128.45 144 Frame 1: 1 110V/220V and 3 220V models up to 0.75kW Frame 2: 1 and 3 220V from 1.5kW and all 3 440V models
iDrive
Easy to install Basic/Advanced set-up DIN rail mounting as standard 1-phase and 3-phase variants V/F and sensorless vector modes High starting torque PID control as standard Keypad potentiometer 8 pre-set speeds DC braking as standard IP65/NEMA 4 models available Side-by-side mounting Thermostatic cooling fan Comprehensive inverter and motor protection functions Remote Keypad options with full copy facility Optional multi-function card PNP or NPN selectable RS232/485 option cards Modbus RTU/ASCII PC software (option) PDA (iPAQ) software (option)
123.5
132
IMO
GUARAN
TE
21 1.3 2.0 2
12.2 1 2.0 2
A B
Common specification
Power Source 110V model: 100~120v +10% / -15%, 50/60Hz 220V model: 200~240v +10% / -15%, 50/60Hz 440V model: 380~480v +10% / -15%, 50/60Hz Selectable V/f or Vector control (starting torque: 100% / 3Hz) 0~200Hz Digital: 0.1Hz (0~99.9Hz) / Hz(100~200Hz; Analogue: 0.6Hz / 60Hz Set with ML keys or the VR on the keypad. Alternatively use the UP/DOWN (Motorised Pot) or the AIN signal 7 segment* 3; display frequency / DC voltage / output voltage / output current / inverter parameters error code / program version / PID feedback 1. External variable resistor / 0-10V / 0-20mA / 2-10V / 4-20mA 2. Motorised Pot (UP/DOWN) Upper/lower frequency limits and two-stage prohibited frequencies 4~16KHz (factory setting 10KHz, 10KHz or more De-rating 0.1~999 sec, two-stage acc./dec. time could be changed By MFIT/Acc/Dec disable NPN/PNP toggle* four points; two points optional (S1~S4 Built in, S5~S6 option) Terminal * 1 point (1a terminal)---setting to Multi-function output. Optional Multi-function Photo Output* 1 point (open collector 24V, 600mA) Setting to speed command and PID feedback signal/MFIT S7 (PNP Mode) Instantaneous power loss restart, Speed search, fault restart, DC brake Torque boost, 2/3 wire control and PID function RS-485 Option Card: Modbus RTU/ASCII mode, 4800~38400 bps max. 254 stations. PC-PDA software link 0-95% Relative humidity (non-condensing) 150% / 1 min -10C to +50C (in distributor) IP20; -10~40C IP65 Over current, over voltage, low voltage, overload, momentary power loss and restart stall prevention for acceleration/deceleration/operation, short-circuit protection for output/grounding fault, reverse restriction, restrictions for direct start after power up and error recovery UL/cUL, CE Integrated Class B (to EN61800-3 / First Environment, unrestricted sales)
Control Mode Frequency Range Frequency Setting Resolution Frequency Setting Method Display Functions External Frequency Setting Output frequency limit function Carrier Frequency Acc/Dec control DI (Digital Output) DO (Digital Output) AI (Analogue Input) Other Function Communication Control Humidity Overload Protection Operating Temperature Other Protection Function
L1 (L) L2 L3(N) PE
T1 T2 T3 PE
PNP common Multi function digital input DC 12/24V signal NPN common Multi function analogue input Set speed PID feed back input Multi function analogue output 0-10VDC
24V S1 S2 S3 S4 COM
RA RB
Multi functional relay output SW1: digital signal selection (NPN/PNP) SW2: Control signal selection (0-10V/4-20mA) Option interface Multi function I/O card (2 in, 1 out) Remote Keypad
1 2
10K
S5 S6 T+ T-
FM