Symphony Hi Cool Operating Instructions
Symphony Hi Cool Operating Instructions
Your comfort is a combination of live factors: such as, room air temperature, room air velocity, humidity content of room air, the
types of clothes that you are wearing and the type of physical work you are doing
Your Symphony Hi Cool air cooler ensures your comfort by managing air conditions by four ways;
1 !t replaces stale and stuffy air from your room with fresh air in "ust a few minutes
# !t provides cool air blast uniformly at your desired location in the room and even covers the entire room by its swinging
air flow
$ !t makes up the humidity level by adding moisture back into the room air and removes any dryness from the air that
surrounds you
% !t maintains consistent air circulation over your body and improves you comfort by reducing body heat
Controls
1 &ir flow switch
# Humidity control
$ Cool and swing switch
% 'ater ( ice inlet
) Hori*ontal louvre
+ 'ater level indicator
, -rain plug
1 Air flow / three speed
.his control enables the customer to operate and control the blower motor operation .he function of the switch is as
follows:
/00 1 !n this position the fan is in off condition
2/' 1 !n this position the fan operates at a low speed
34- 1 !n this position the fan operates at a medium speed
H!5H 1 !n this position the fan operates at the highest speed
# Cooling and swing
.his function enables the user to operate the pump and start the cooling operation
$ Humidity control 62ocated in the ice bo78
'ith this function you can control the level of humidity in the room
OFF 1 !n this position all the water which is pumped is by passed from the cellulose pad and the pads are then not
getting wet .his is able to keep the humidity close to atmospheric humidity level
ON 1 &s soon as the knob is turned in a clockwise direction, the water which is being pumped
% Timer 6!n select models only8
.his function allows the customer to set the timing for the unit to be in operation .his function can also be bypassed
OFF 1 !n this position the cooler remains in off condition
0! hours 1 9y turning the knob clockwise from the :off; position, one can set the timing for the cooler to be :on;
starting from < hours to almost = hours .his is a continuously varying control
Continuous operation 1 !n this position the unit is on continuous run mode by turning the knob anti>clockwise from
the :off; position
Trou"le Shooting
Your symphony H;C//2 cools to nature;s limits 6it lowers dry bulb temperature to wet bulb temperature8, which means the
hotter the day the better your Symphony H;C//2 performs
!f your Symphony H;C//2 air cooler fails to operate, check the following before calling 2ondon Cool on <=<< %%< %%% for service:
1 Check that there is power at the power point
# Check that the power point is switched on and that the plug is in place correctly
$ Check that the controls are set properly
Care of H#COO$ air cooler
1 'hen unit is not in operation be sire to turn off the switches to the off position
# /perate the controls gently
$ -o not wipe the air cooler with harsh chemicals, scrubbing powder or ?C thinner as they will damage the finish
% -o not keep heavy load on top of the unit
) -o not add bleaching agent into the water tank
+ 9efore moving or replacing the unit ensure that the water tank is empty
%aintenance
.he symphony H;C//2 cooler has been designed to move from room to room so that you en"oy the comfort it provides where
you need it .his unit is intended for office use only
4very fortnight 1 -rain out the water from the tank, and clean the e7ternal parts
Safety precautions / warnings
Read and save these instructions
1 -o not open any knob ( cover when the unit is in operation
# .o avoid electric fire or electric shock or in"ury to person, always unplug or disconnect the appliance from the power
supply before servicing, cleaning, or while carrying out maintenance
$ -o not try to fill water manually into the cooler while the unit is in operation
% -o not overfill the water tank
) 'hile servicing and during replacement of any component in the appliance, please ensure that the safety devise is
reinstalled or remounted
+ .o reduce risk of fire or electric shock, do not use this cooler with any solid state speed control devise
, -o not put any weight on the top of the unit
$ondon Cool air conditioner rental and sales
.his document has been compiled in good faith, but no representation is made or warranty given 6either e7press or implied8 as
to the completeness or accuracy of this information