Fujikura - Optical Components
Fujikura - Optical Components
URL : www.fujikura.co.jp
For Enquiry
Email :
[email protected]
FTM Series
Optical Termination Rack (Central Ofce)
Features
Provide efcient termination, storage, splicing and management of
optical bers from Central ofce to OSP.
Suitable for indoor application inside central ofce.
19 inch rack mounted concept with expandable modular FDU,
splitter module.
Storage shelf provided for excess patch cord.
Splitter module and Fiber Monitoring system available for option.
Compatible with Industry standard equipment. (ETSI,EIA)
Front View
FTM-1000F
Rear View
Optical Test Unit
Easy access to each port
Splitter Module Splitter Module Unit
Optical Fiber Selector
Splice tray for OSP cable
2D-barcode tag Cord bundled cable
Coupler integrated module
Specications
Option
Item Content
Using of Area Indoor
Direction of access Front and Rear access
Number of OSP cable Max:21 cables
Number of Termination Unit
Max.7units
(Max.port No. 1008F=144Fx7units)
19 rack mount (EIA standard)
4U size (177.8mm)
Connector Type SC
Dimension (mm) W800 x H2200 x D600
Wight (kg) Approx. 250
Main body Steel Thickness ; 2.0mm
Color Light Gray
Item FTM-1000F FTM-600F FTM-300F
Rack 1set 1set 1set
Splice/Patching Unit 7units 4units 2units
Storage Shelf 1set 1set 1set
Cable Clamp 1set 1set 1set
Accessories 1set 1set 1set
For Fiber Monitoring System
OPTICAL COMPONENTS
OPTICAL FIBERS OPTICAL CABLES MONITORING / MANAGEMENT SYSTEM
30
Notes
Optical Termination Rack
Variety Type of Termination Rack
Only Front Access type
(Depth 300mm)
1,000-port Termination Rack
SC connector , Splice Tray
For all your connection needs
Full Customization for Full Flexibility
Super High Density type
4,000-port Termination Rack
MU connector, pre-connectorized cable (OSP cable)
(Fiber Monitoring system integrated)
Standard type
2,400-port Termination Rack
SC2 connector , Splice Tray
31
Latest information also available on the internet
URL : www.fujikura.co.jp
For Enquiry
Email :
[email protected]
Specications of FDC
Applications
FTTH OSP network applications.
Fiber Distribution Cabinet FDC Series
Splitter
Splice Tray
Splice Tray
Connector
Adapter
Fusion Splice Point
Features & Benets
Modular distribution units and splitter modules allow scalable high-value
assets, such as opticalsplitters, to match take rates.
Front door entry allows easy access.
R-guide and cord guide provided for simplied routing and neat ber
management.
Expandable to larger capacity upon request.
The FDC ber distribution cabinet is a local convergence hub in the outside plant envi-
ronment for multiple subscribers. It provides easy testing and troubleshooting access
as all splitters are at the same point.
Parameter FDC-144FB(N)
(1)
Installation Outdoor, Pad Mount
Degree of Protection (IP Code) IP55 (IEC 60529)
Access Front & Rear
Function
(1) Incoming / Outgoing Cable Termination
(2) Splitting (PON) / Bypass (Point-to-point)
(3) Cross-connect
Conguration
(1) Outdoor Cabinet with 19"" Rack Frame: 1
(2) Splice / Patching Shelf (Input, 34F, 2U): 1
(3) Splice / Patching Shelf (Output, 128F, 4U): 1
(4) Splitter Module Rack (4U): 1
(5) Cable Management Guide: 1
Splitter Module Capacity 18 modules / rack
Connection Type Splice & Connector
Number of Connection Input: 34; Output: 128
Connector Type SC/APC (Green) or SC/UPC (Blue); Compliant with IEC 61754-4
Splice Capacity Input: 48F (2 trays); Output: 144F (6 trays)
Applicable Incoming / Outgoing Cable
Entry Bottom
Number 8
Diameter [mm] 11 to 16
Main Body Paint-coated Stainless Steel; Light Gray
Dimensions [mm] 660 W x 1,115 H x 140 D
Weight [kg] Approx. 100
(1) Please contact us for larger capacity, customized designs / congurations / modules.
Splitter Module
Splice/patching shelf
for Input cable
Splice/patching shelf
for Output cable
Cord spool
OPTICAL COMPONENTS
OPTICAL FIBERS OPTICAL CABLES MONITORING / MANAGEMENT SYSTEM
32
Notes
Fiber Distribution Cabinet FDC Series
Specications of Splitter Modules (FSC-110 Series)
(2)
Ordering Information
# Model Number Description
1 FDC-144FB(N)(APC)
(3)
Fiber Distribution Cabinet, Outdoor, 144F, SC/APC, No Splitters
2 FDC-144FB(N)(UPC)
(3)
Fiber Distribution Cabinet, Outdoor, 144F, SC/UPC, No Splitters
3 FSC110-1 x 4-SC/APC Splitter Module, 1 x 4, SC/APC, Receptacle
4 FSC110-1 x 8-SC/APC Splitter Module, 1 x 8, SC/APC, Receptacle
5 FSC110-1 x 16-SC/APC Splitter Module, 1 x 16, SC/APC, Receptacle
6 FSC110-2 x 4-SC/APC Splitter Module, 2 x 4, SC/APC, Receptacle
7 FSC110-2 x 8-SC/APC Splitter Module, 2 x 8, SC/APC, Receptacle
8 FSC110-2 x 16-SC/APC Splitter Module, 2 x 16, SC/APC, Receptacle
9 FSC110-1 x 4-SC/UPC Splitter Module, 1 x 4, SC/UPC, Receptacle
10 FSC110-1 x 8-SC/UPC Splitter Module, 1 x 8, SC/UPC, Receptacle
11 FSC110-1 x 16-SC/UPC Splitter Module, 1 x 16, SC/UPC, Receptacle
12 FSC110-2 x 4-SC/UPC Splitter Module, 2 x 4, SC/UPC, Receptacle
13 FSC110-2 x 8-SC/UPC Splitter Module, 2 x 8, SC/UPC, Receptacle
14 FSC110-2 x 16-SC/UPC Splitter Module, 2 x 16, SC/UPC, Receptacle
(3) No pigtails / ber protection sleeves included.
FSC-110 series
Parameter 1 x 2 1 x 4 1 x 8 1 x 16 1 x 32
Installation Splitter Module Rack for FSC-110 (19", 3U)
Module Capacity 18 9 4
Fiber Singlemode
Operating Wavelength [nm] 1,290 - 1,330, 1480-1500, 1530-1570
Operating Temperature & Humidity -10 to +40 degC, 90 % RH
Storage Temperature & Humidity -20 to +70 degC, 95 % RH
Splitter Module
Insertion Loss [dB] 4.3 8.0 11.6 14.9 18.4
Uniformity [dB]* 0.9 2.0 1.0 1.5 2.0
Return Loss [dB] 50 (UPC,APC)
Connector Type SC/APC (Green) or SC/UPC (Blue); Compliant with IEC 61754-4
Dimensions [mm] W x H x D 22 x 130 x 117 47 x 130 x 117 97 x 130 x 117
*Except connector loss uniformity
(2) Please contact us for customized designs / congurations / modules.
Splitter module rack (for FSC-110)
33
Latest information also available on the internet
URL : www.fujikura.co.jp
For Enquiry
Email :
[email protected]
Features & Benets
Suitable for interconnect, cross-connect, customer premise and
various environments.
Compatible with industry standard equipment frames.
Light weight for easy installation.
Slide-out drawer for easy access to connectors and splice trays.
Various connector interfaces available upon request.
Customized designs and integrated or extremely-dense cabling
systems available upon request.
Specications (Simplex SC Type)
Applications
Telecommunication Central Ofces.
Customer Premises.
Outdoor Cabinets.
Data Centers.
CCTV Security Systems.
SCADA Systems. etc.
Rack-mount Patch Panel FDU Series
FDU-24F (LC)-CA
Parameter
4F
SC
24F
SC
36F
SC
48F
SC
72F
SC
96F
SC
144F
SC
288F
(1)
SC
Installation Indoor, 19" Rack Mount (EIA)
Main Body Material Aluminum
Color Black
Adapter
Type Simplex SC; Compliant with IEC 61754-4 (Green for Singlemode APC or Blue for Singlemode UPC)
Number 4 24 36 48 72 96 144 288
Splice Capacity
(2)
24 (1 tray) 48 (2 trays) 72 (3 trays) 96 (4 trays) 144 (6 trays) 288 (12 trays)
Number of Cables 2
2
(-CA)
4
(-CA4)
4
Dimensions [mm] 483 W x 44 H x 310 D (1U) 483 W x 88 H x 310 D (2U) 483 W x 133 H x 310 D (3U)
483 W x 177 H
x 310 D (4U)
483 W x 400 H
x 310 D (9U)
Weight [kg] Approx. 2 Approx. 2.5 Approx. 3 Approx. 3.5 Approx. 8
(1) 2 ea of 144F FDU-CAs stacked.
(2) No pigtails or ber protection sleeves included.
Adapter
Optical
Cable
Connector
Fusion Splice Point
Adapter
Central ofce application. Data center application.
OPTICAL COMPONENTS
OPTICAL FIBERS OPTICAL CABLES MONITORING / MANAGEMENT SYSTEM
34
Notes
Rack-mount Patch Panel FDU Series
Specications (Duplex LC Type)
Parameter
4F
LC
24F
LC
36F
LC
48F
LC
72F
LC
96F
LC
144F
LC
288F
(1)
LC
Installation Indoor, 19" Rack Mount (EIA)
Main Body Material Aluminum
Color Black
Adapter
Type Duplex LC; Compliant with IEC 61754-20 (Blue for Singlemode UPC or Beige for Multimode PC)
Number 2 12 18 24 36 48 72 144
Splice Capacity
(2)
24 (1 tray) 48 (2 trays) 72 (3 trays) 96 (4 trays) 144 (6 trays) 288 (12 trays)
Number of Cables 2
2
(-CA)
4
(-CA4)
4
Dimensions [mm] 483 W x 44 H x 310 D (1U) 483 W x 88 H x 310 D (2U) 483 W x 133 H x 310 D (3U)
483 W x 177 H
x 310 D (4U)
483 W x 400 H
x 310 D (9U)
Weight [kg] Approx. 2 Approx. 2.5 Approx. 3 Approx. 3.5 Approx. 8
(1) 2 ea of 144F FDU-CAs stacked.
(2) No pigtails or ber protection sleeves included.
Specications (Cable Organizer)
Parameter FTB-R-WMPT (1U)
installation Indoor,19" Rack Mount (EIA)
Colo Black
Dimensions [mm] 482 W x 43 H x 267 D (1U)
Weight [kg] Approx. 2.6
Ordering Information
# Model Number Description
1 FDU-4F (SC/APC)-CA FDU, 4F, 4 Simplex SC/APC, Green, 2 Cable Clamps
2 FDU-24F (SC/APC)-CA FDU, 24F, 24 Simplex SC/APC, Green, 2 Cable Clamps
3 FDU-36F (SC/APC)-CA FDU, 36F, 36 Simplex SC/APC, Green, 2 Cable Clamps
4 FDU-48F (SC/APC)-CA FDU, 48F, 48 Simplex SC/APC, Green, 2 Cable Clamps
5 FDU-72F (SC/APC)-CA FDU, 72F, 72 Simplex SC/APC, Green, 2 Cable Clamps
6 FDU-96F (SC/APC)-CA FDU, 96F, 96 Simplex SC/APC, Green, 2 Cable Clamps
7 FDU-144F (SC/APC)-CA FDU, 144F, 144 Simplex SC/APC, Green, 2 Cable Clamps
8 FDU-144F (SC/APC)-CA4 FDU, 144F, 144 Simplex SC/APC, Green, 4 Cable Clamps
9 FDU-288F (SC/APC)-CA FDU, 288F, 288 Simplex SC/APC, Green, 4 Cable Clamps
10 FDU-4F (SC)-CA FDU, 4F, 4 Simplex SC/UPC, Blue, 2 Cable Clamps
11 FDU-24F (SC)-CA FDU, 24F, 24 Simplex SC/UPC, Blue, 2 Cable Clamps
12 FDU-36F (SC)-CA FDU, 36F, 36 Simplex SC/UPC, Blue, 2 Cable Clamps
13 FDU-48F (SC)-CA FDU, 48F, 48 Simplex SC/UPC, Blue, 2 Cable Clamps
14 FDU-72F (SC)-CA FDU, 72F, 72 Simplex SC/UPC, Blue, 2 Cable Clamps
15 FDU-96F (SC)-CA FDU, 96F, 96 Simplex SC/UPC, Blue, 2 Cable Clamps
16 FDU-144F (SC)-CA FDU, 144F, 144 Simplex SC/UPC, Blue, 2 Cable Clamps
17 FDU-144F (SC)-CA4 FDU, 144F, 144 Simplex SC/UPC, Blue, 4 Cable Clamps
18 FDU-288F (SC)-CA FDU, 288F, 288 Simplex SC/UPC, Blue, 4 Cable Clamps
19 FDU-4F (LC)-CA FDU, 4F, 2 Duplex LC/UPC, Blue, 2 Cable Clamps
# Model Number Description
20 FDU-24F (LC)-CA FDU, 24F, 12 Duplex LC/UPC, Blue, 2 Cable Clamps
21 FDU-36F (LC)-CA FDU, 36F, 18 Duplex LC/UPC, Blue, 2 Cable Clamps
22 FDU-48F (LC)-CA FDU, 48F, 24 Duplex LC/UPC, Blue, 2 Cable Clamps
23 FDU-72F (LC)-CA FDU, 72F, 36 Duplex LC/UPC, Blue, 2 Cable Clamps
24 FDU-96F (LC)-CA FDU, 96F, 48 Duplex LC/UPC, Blue, 2 Cable Clamps
25 FDU-144F (LC)-CA FDU, 144F, 72 Duplex LC/UPC, Blue, 2 Cable Clamps
26 FDU-144F (LC)-CA4 FDU, 144F, 72 Duplex LC/UPC, Blue, 4 Cable Clamps
27 FDU-288F (LC)-CA FDU, 288F, 144 Duplex LC/UPC, Blue, 4 Cable Clamps
28 FDU-4F (LC/PC)-CA FDU, 4F, 2 Duplex LC/PC, Blue, 2 Cable Clamps
29 FDU-24F (LC/PC)-CA FDU, 24F, 12 Duplex LC/PC, Beige, 2 Cable Clamps
30 FDU-36F (LC/PC)-CA FDU, 36F, 18 Duplex LC/PC, Beige, 2 Cable Clamps
31 FDU-48F (LC/PC)-CA FDU, 48F, 24 Duplex LC/PC, Beige, 2 Cable Clamps
32 FDU-72F (LC/PC)-CA FDU, 72F, 36 Duplex LC/PC, Beige, 2 Cable Clamps
33 FDU-96F (LC/PC)-CA FDU, 96F, 48 Duplex LC/PC, Beige, 2 Cable Clamps
34 FDU-144F (LC/PC)-CA FDU, 144F, 72 Duplex LC/PC, Beige, 2 Cable Clamps
35 FDU-144F (LC/PC)-CA4 FDU, 144F, 72 Duplex LC/PC, Beige, 4 Cable Clamps
36 FDU-288F (LC/PC)-CA FDU, 288F, 144 Duplex LC/PC, Beige, 4 Cable Clamps
37 FTB-R-WMPT (1U) Cable Organizer, 1U, Tray Type
Patchcords compliant with ISO/IEC 11801 and TIA/EIA-568-C.3 available for customer premises and
commercial building telecommunications cabling.
Simplex and zipcord cables meet TIA/EIA 568-C.3, Telcordia GR-409-CORE and Directive 2002/95/EC
(RoHS) and Plenum, Riser and OFNR-listed LSZH grade jackets available.
LSZH meets the requirement of IEC 61034-1, 61034-2, 60332-1-1,60332-1-2, 60754-1 and 60754-2.
OS1, OS2 and bend-insensitive FutureGuide-SR15E compliant with ITU-T G.657.A1 for singlemode
applications and OM1, OM2, OM3 and OM4 for multimode applications available as options.
35
Latest information also available on the internet
URL : www.fujikura.co.jp
For Enquiry
Email :
[email protected]
Fiber Distribution Panel FDPanel Series
Applications
Fiber interconnection and distribution in FTTH, utilities and data networks.
Building entrance applications in FTTH, utilities and data networks.
Connector
Adapter
Optical
Cable
Indoor Cable or
Patchcord
1-side Splice Fusion Splice Point
Features & Benets
Provides connection points for interconnecting and
distributing bers in interconnection, distribution and
building entrance applications.
Suitable for indoor environments.
Secured with a key.
Swivel patch panel for easy access to connectors (12F, 24F,
36F and 48F).
Customized designs and congurations, such as outdoor
types, two compartment types, customized number of
cables, termination of outgoing round cables with tension
members or at drop cables, etc., available upon request.
OPTICAL COMPONENTS
OPTICAL FIBERS OPTICAL CABLES MONITORING / MANAGEMENT SYSTEM
Specications (Higher Fiber Counts)
Parameter 192F 144F 96F 72F
Installation Indoor, Wall Mount
Patch Panel Fixed
Connection Type Pigtail & Splice
(1)
Number of Connection 192 144 96 72
Connector Type SC/APC (Green) or SC/UPC (Blue); Compliant with IEC 61754-4
Splice Capacity
Incoming 192F (8 trays) 144F (6 trays) 96F (4 trays) 72F (3 trays)
Outgoing -
Cable Entry Lower
Applicable Incoming Cable
Type 17 mm dia. (Tension Member Clamps applicable)
Number of Holes 2
Applicable Outgoing Cable (Bunched)
Type 17 mm dia. (No Tension Member Clamps, Tied)
Number of Holes 8 6 4 3
Main Body Electro-galvanized Steel; Gray
Dimensions [mm] 440 W x 770 H x 160 D 420 W x 620 H x 160 D 420 W x 470 H x 160 D 420 W x 400 H x 140 D
Weight [kg] Approx. 20 Approx. 17 Approx. 14 Approx. 13
(1) No pigtails or ber protection sleeves included.
36
Notes
Fiber Distribution Panel FDPanel Series
Specications (Lower Fiber Counts)
Parameter 48F 36F 24F 12F
Installation Indoor, Wall Mount
Patch Panel Swivel
Connection Type Pigtail & Splice
(1)
Number of Connection 48 36 24 12
Connector Type SC/APC (Green) or SC/UPC (Blue); Compliant with IEC 61754-4
Splice Capacity
Incoming 48F (2 trays) 24F (1 tray)
Outgoing -
Cable Entry Lower
Applicable Incoming Cable
Type 17 mm dia. (Tension Member Clamps applicable)
Number of Holes 2
Applicable Outgoing Cable (Bunched)
Type 17 mm dia. (No Tension Member Clamps, Tied)
Number of Holes 2
Main Body Electro-galvanized Steel; Gray
Dimensions [mm] 340 W x 400 H x 130 D 340 W x 330 H x 130 D 340 W x 330 H x 110 D 340 W x 280 H x 80 D
Weight [kg] Approx. 11 Approx. 10 Approx. 9 Approx. 8
(1) No pigtails or ber protection sleeves included.
Ordering Information
# Model Number Description
1 FDPanel-192F SC/APC FDPanel, Indoor, 192F, 192SC/APC, 1-side Splice
2 FDPanel-144F SC/APC FDPanel, Indoor, 144F, 144SC/APC, 1-side Splice
3 FDPanel-96F SC/APC FDPanel, Indoor, 96F, 96SC/APC, 1-side Splice
4 FDPanel-72F SC/APC FDPanel, Indoor, 72F, 72SC/APC, 1-side Splice
5 FDPanel-48F SC/APC FDPanel, Indoor, 48F, 48SC/APC, 1-side Splice
6 FDPanel-36F SC/APC FDPanel, Indoor, 36F, 36SC/APC, 1-side Splice
7 FDPanel-24F SC/APC FDPanel, Indoor, 24F, 24SC/APC, 1-side Splice
8 FDPanel-12F SC/APC FDPanel, Indoor, 12F, 12SC/APC, 1-side Splice
9 FDPanel-192F SC/UPC FDPanel, Indoor, 192F, 192SC/UPC, 1-side Splice
10 FDPanel-144F SC/UPC FDPanel, Indoor, 144F, 144SC/UPC, 1-side Splice
11 FDPanel-96F SC/UPC FDPanel, Indoor, 96F, 96SC/UPC, 1-side Splice
12 FDPanel-72F SC/UPC FDPanel, Indoor, 72F, 72SC/UPC, 1-side Splice
13 FDPanel-48F SC/UPC FDPanel, Indoor, 48F, 48SC/UPC, 1-side Splice
14 FDPanel-36F SC/UPC FDPanel, Indoor, 36F, 36SC/UPC, 1-side Splice
15 FDPanel-24F SC/UPC FDPanel, Indoor, 24F, 24SC/UPC, 1-side Splice
16 FDPanel-12F SC/UPC FDPanel, Indoor, 12F, 12SC/UPC, 1-side Splice
37
Latest information also available on the internet
URL : www.fujikura.co.jp
For Enquiry
Email :
[email protected]
Features & Benets
Provides distribution points for terminating, splitting and
cross-connecting bers.
Pass-through riser cable installable.
Various congurations of pre-installed splitters, and
centralized splitting for low-rise building and two stage
splitting with compact splitter modules (FSC114 series) for
high-rise building possible.
Secured with a key.
Customized designs and congurations available upon
request.
Applications
FTTH MDU applications. 32 / 64 subscribers supported by 32F / 64F
type. 256 / 512 subscribers supported by 32F / 64F type and 1x8
compact splitter modules (FSC114 series) with two stage splitting.
Fiber Distribution Hub FTB Series
Parameter 32F 64F
Installation Indoor, Wall Mount
Function
(1) Cable Termination
(2) Splitting (PON)
(3) Cross-connect
Conguration
(1) 8 ea of 1 x 4 (1) 16 ea of 1 x 4
(2) 4 ea of 1 x 8 (2) 8 ea of 1 x 8
(3) 1 ea of 1 x 32 (3) 2 ea of 1 x 32
Connection Type (1) Input: Splice; Output: Connector
Number of Connection
Input 24 (1 tray) 24 (1 tray)
Output 32 64
Connector Type SC/APC (Green) or SC/UPC (Blue); Compliant with IEC 61754-4
Cable Entry Upper & Lower
Applicable Incoming Cable
Type Feeder or Riser Cable (Pass-through possible)
Number 1
Applicable Outgoing Cable
Type Standard / Low-friction Flat Drop Cable (2 / 1.6 mm t)
Number 32 64
Main Body Steel; Gray
Dimensions [mm] 450 W x 400 H x 110 D 450 W x 440 H x 145 D
Weight [kg] Approx. 15 Approx. 16
(1) No pigtails, ber protection sleeves or connectors included.
Specications
Ordering Information
# Model Number Description
1 FTB-32D-SP & PT SC/APC 1-1 x 32 Fiber Distribution Hub, Indoor, 32 Drops, Pass-through, SC/APC, 1-1 x 32
2 FTB-32D-SP & PT SC/APC 4-1 x 8 Fiber Distribution Hub, Indoor, 32 Drops, Pass-through, SC/APC, 4-1 x 8
3 FTB-32D-SP & PT SC/APC 8-1 x 4 Fiber Distribution Hub, Indoor, 32 Drops, Pass-through, SC/APC, 8-1 x 4
4 FTB-64D-SP & PT SC/APC 2-1 x 32 Fiber Distribution Hub, Indoor, 64 Drops, Pass-through, SC/APC, 2-1 x 32
5 FTB-64D-SP & PT SC/APC 8-1 x 8 Fiber Distribution Hub, Indoor, 64 Drops, Pass-through, SC/APC, 8-1 x 8
6 FTB-64D-SP & PT SC/APC 16-1 x 4 Fiber Distribution Hub, Indoor, 64 Drops, Pass-through, SC/APC, 16-1 x 4
7 FTB-32D-SP & PT SC/UPC 1-1 x 32 Fiber Distribution Hub, Indoor, 32 Drops, Pass-through, SC/UPC, 1-1 x 32
8 FTB-32D-SP & PT SC/UPC 4-1 x 8 Fiber Distribution Hub, Indoor, 32 Drops, Pass-through, SC/UPC, 4-1 x 8
9 FTB-32D-SP & PT SC/UPC 8-1 x 4 Fiber Distribution Hub, Indoor, 32 Drops, Pass-through, SC/UPC, 8-1 x 4
10 FTB-64D-SP & PT SC/UPC 2-1 x 32 Fiber Distribution Hub, Indoor, 64 Drops, Pass-through, SC/UPC, 2-1 x 32
11 FTB-64D-SP & PT SC/UPC 8-1 x 8 Fiber Distribution Hub, Indoor, 64 Drops, Pass-through, SC/UPC, 8-1 x 8
12 FTB-64D-SP & PT SC/UPC 16-1 x 4 Fiber Distribution Hub, Indoor, 64 Drops, Pass-through, SC/UPC, 16-1 x 4
Connector
Fusion Splice Point
Adapter
Splitter
FAST Connector
Optical Cable
Drop Cable
OPTICAL COMPONENTS
OPTICAL FIBERS OPTICAL CABLES MONITORING / MANAGEMENT SYSTEM
38
Notes
Specications
Parameter Value
Installation Indoor, Wall Mount
Connection Type Fusion or Mechanical Splice
Main Cable Entrance Upper or Lower
Incoming Cable Count
Round Cable
(2)
( 16 mm dia.) 1
Flat Drop Cable (1.6 / 2 / 3.3 mm t) 3
Outgoing Cable Count
Round Cable
(2)
( 16 mm dia.) 2
Simplex Cable (1.6 / 2 mm dia.) 12
Flat Drop Cable (1.6 / 2 / 3.3 mm t) 24
Splice Capacity
(1)
Single Fiber (0.25 mm dia.) 24F
Single Fiber (0.9 mm dia.) 8F
4F Ribbon 40F (10 Ribbons)
Through-ber Capacity
(4F Ribbon)
One Side Branch 160F (40 Ribbons)
Both Side Branch 120F (30 Ribbons)
Splitter Capacity
(1)
1 x 4 4 ea
1 x 8 2 ea
1 x 16 1 ea
1 x 32 1 ea
Color Ivory
Dimensions [mm] 160 W x 180 H x 38 D
Weight [kg] Approx. 0.3
(1) Element Dimensions [mm]: 4 W x 4 H x 60 L in Splice Slot; 7 W x 9.5 H x 70 L in Splitter Slot.
(2) Tension Member Diameter [mm] 3.2.
Ordering Information
# Model # Description
1 FTB-601-12C
Fiber Splice Box, Indoor, Wall Mount, 24F,
12 Standard Drop Cables.
2 FTB-601-24Q
Fiber Splice Box, Indoor, Wall Mount, 24F,
24 Standard Drop Cables.
3 FTB-601-12C (C)
Fiber Splice Box, Indoor, Wall Mount, 24F,
12 Low-friction Drop Cables.
4 FTB-601-24Q (C)
Fiber Splice Box, Indoor, Wall Mount, 24F,
24 Low-friction Drop Cables.
5 C sleeve
C Sleeve, For 2.5-4.5mm dia. FRP Strength
Member.
Fiber Splice Box FTB-601
Features & Benets
Versatile splice box for FTTH MDU applications.
Compact and suitable for limited riser space.
Various types of cables can be installed in various directions.
Splitter can be installed.
Mid-span access with through-bers can be done.
Applications
FTTH MDU applications.
Structure
Red:
Main Cable into Box
Blue: Flat Drop / Simplex
Cable into Box
Green:
Fibers into Slack Tray
Tension Member
Clamp x 3
Cable Clamp x 3
Slack Tray
Splice Slot x 12
(2 ea/slot)
Splitter Slot x 1
Tie Strip
Flat Drop / Simplex
Cable Clamp
Wiring Conguration
Splice Through-fibers
Flat Drop or Round Simplex Cable Flat Drop or Round Simplex Cable
Splice
Through-fibers
Splitter
Main Cable Main Cable
39
Latest information also available on the internet
URL : www.fujikura.co.jp
For Enquiry
Email :
[email protected]
Features & Benets
Indoor wall-mountable outlet with 1 / 2 / 4 SC port(s).
Compact and light weight.
Cable entry from any of 4 directions possible to enable
exible cabling.
Applications
FTTH MDU and SDU applications.
Optical Outlet FPB-103A / 302 / 301
FPB-302 FPB-301 FPB-103A
Specications
Parameter FPB-103A
FPB-302 FPB-301
(No Sufx) FS PR (No Sufx) FS PR
Installation Indoor, Wall Mount
Connection Type Connector Connector
Pigtail &
Splice
Connector
Pigtail &
Splice
Number of Connection 1 2 4
Connector Type SC/APC (Green) or SC/UPC (Blue); Compliant with IEC 61754-4
Appended Connectors or Pigtails
(1)
n/a n/a 2 FAST-SCs 2 Pigtails n/a 4 FAST-SCs
4F Ribbon
Pigtail
(2)
Incoming Cable Entry Upper, Lower, Right or Left
Applicable Incoming
Cable
Type
Standard / Low-friction
(3)
Flat Drop Cable (2 / 1.6 mm t) with 15 / 7.5 mm Bend Radius Fiber (FutureGuide-SR15E / BIS-B)
n/a Round Cable ( 8 mm dia.) Round Cable ( 10 mm dia.)
Number 1F x 1 Discrete 2F x 1 4F Ribbon
(2)
x 1
Recommended
Outgoing Cable
Type Bend-insensitive Patchcord (MageTsuyo) with 15 / 7.5 mm Bend Radius Fiber (FutureGuide-SR15E / BIS-B)
Number 1 2 4
Main Body
PC; Ivory;
Compliant with UL-94 V0;
Shutter for Dust-proof and Eye Safety
PC; White Gray;
Compliant with UL-94 V0;
Connector Cover for Protection
PP; White Gray;
Connector Cover for Protection
Dimensions [mm] 50 W x 93 H x 18 D 70 W x 150 H x 15.3 D 76 W x 165 H x 26 D
Weight [kg] Approx. 0.1 Approx. 0.1 Approx. 0.1
(1) No ber protection sleeves are included.
(2) 4 ea of discrete ber pigtails for discrete ber cable are available upon request.
(3) Regarding FPB-302 and FBP-301, low-friction at drop cable will be secured with cable tie and cable entry will be limited to lower direction for FPB-302 and upper one for FPB-301.
Ordering Information
# Model Number Description
1 FPB-103A (APC) Optical Outlet, Indoor, Wall Mount, 1F, 1SC/APC
2 FPB-103A (UPC) Optical Outlet, Indoor, Wall Mount, 1F, 1SC/UPC
3 FPB-302-2SC (APC) Optical Outlet, Indoor, Wall Mount, 2F, 2SC/APC, No Pigtails / Connectors
4 FPB-302-2SC (UPC) Optical Outlet, Indoor, Wall Mount, 2F, 2SC/UPC, No Pigtails / Connectors
5 FPB-302-2SC-FS (APC) Optical Outlet, Indoor, Wall Mount, 2F, 2SC/APC, FAST Connectors
6 FPB-302-2SC-FS (UPC) Optical Outlet, Indoor, Wall Mount, 2F, 2SC/UPC, FAST Connectors
7 FPB-302-2SC-PR (APC) Optical Outlet, Indoor, Wall Mount, 2F, 2SC/APC, Pre-assembled Simplex Pigtails
8 FPB-302-2SC-PR (UPC) Optical Outlet, Indoor, Wall Mount, 2F, 2SC/UPC, Pre-assembled Simplex Pigtails
9 FPB-301-4SC (APC) Optical Outlet, Indoor, Wall Mount, 4F, 4SC/APC, No Pigtails / Connectors
10 FPB-301-4SC (UPC) Optical Outlet, Indoor, Wall Mount, 4F, 4SC/UPC, No Pigtails / Connectors
11 FPB-301-4SC-FS (APC) Optical Outlet, Indoor, Wall Mount, 4F, 4SC/APC, FAST Connectors
12 FPB-301-4SC-FS (UPC) Optical Outlet, Indoor, Wall Mount, 4F, 4SC/UPC, FAST Connectors
13 FPB-301-4SC-PR (APC) Optical Outlet, Indoor, Wall Mount, 4F, 4SC/APC, Pre-assembled Fan-out Pigtails
14 FPB-301-4SC-PR (UPC) Optical Outlet, Indoor, Wall Mount, 4F, 4SC/UPC, Pre-assembled Fan-out Pigtails
OPTICAL COMPONENTS
OPTICAL FIBERS OPTICAL CABLES MONITORING / MANAGEMENT SYSTEM
40
Notes
Demarcation Box FPB-203
Incoming / Outgoing Direction (Ex.):
Red: Incoming
Blue: Outgoing
2 ea of flat drop cables
stackable in a slot.
Incoming Flat
Drop Cable
Outgoing Flat
Drop Cable
Up to 4 connections.
FAST-SC
FAST-SC
FAST-SC Connector
for Flat Drop Cable
SC Adapter
FAST-SC Connector
for Flat Drop Cable
2 ea of SC adapters
stackable in a slot.
SC Adapter
Applications
FTTH MDU and SDU applications.
Specications
Parameter FPB-203-1SC-A(N) FPB-203-2SC-A(N) FPB-203-4SC-A(N)
Installation Indoor and Outdoor, Wall Mount
Degree of Protection
(IP Code)
IP55 (IEC 60529)
Connection Type Connector
Number of Connection 1 2 4
Connector Type
(1)
SC/APC (Green) or SC/UPC (Blue); Compliant with IEC 61754-4
Cable Entry Lower
Applicable
Incoming Cable
(2)
Type
Standard Flat Drop Cable (2 mm t)
with 15 / 7.5 mm Bend Radius Fiber (FutureGuide-SR15E / BIS-B)
Number 4
Applicable
Outgoing Cable
(2)
Type
Standard Flat Drop Cable (2 mm t)
with 15 / 7.5 mm Bend Radius Fiber (FutureGuide-SR15E / BIS-B)
Number 4
Main Body PC; Gray; Compliant with UL 94 V-1
Lock Lockable with Padlock, etc. (Option)
Dimensions [mm] 104 W x 203 H x 38 D
Weight [kg] Approx. 0.3
(1) Adapter(s) included. No connector(s) included.
(2) Please contact us regarding customized designs for terminations of low-friction at drop cables
(1.6 mm t), splices of connectorized pigtails, etc.
Ordering Information
# Model Number Description
1 FPB-203-1SC-A(N) Demarcation Box, 1F, 1SC/UPC, No Connector
2 FPB-203-2SC-A(N) Demarcation Box, 2F, 2SC/UPC, No Connectors
3 FPB-203-4SC-A(N) Demarcation Box, 4F, 4SC/UPC, No Connectors
4 FPB-203-1SC/APC-A(N) Demarcation Box, 1F, 1SC/APC, No Connector
5 FPB-203-2SC/APC-A(N) Demarcation Box, 2F, 2SC/APC, No Connectors
6 FPB-203-4SC/APC-A(N) Demarcation Box, 4F, 4SC/APC, No Connectors
FPB-203-2SC-A (N)
Features & Benets
Joints at drop cables through connectors as a demarcation
box.
Wall-mountable and suitable for indoor and outdoor use.
Lockable with padlock, etc. (option)
41
Latest information also available on the internet
URL : www.fujikura.co.jp
For Enquiry
Email :
[email protected]
OPTICAL COMPONENTS
OPTICAL FIBERS OPTICAL CABLES MONITORING / MANAGEMENT SYSTEM
Features
19 rack mountable splitter module is signed for FTTH central ofce
solution.
19 Rack Mountable
Various Splitter Congurations available
1x2, 1x4, 1x8, 1x16 and 1x32; 2 Input Option for Redundancy
Various Connector and Polish Types (SC; UPC, APC) available
Flexible Design and Various Module Congurations are available
(Ex. 1x32 in 1U Body)
Easy Installation and Removal with High Density
Applications
19 rack mountable splitter module is suitable for 1xn splitting of optical signal, which can cover most of the applications in the ber distribution
networks like Fiber To The Home (FTTH), especially for the central ofce solution.
19 rack mountable splitter module shall be accommodated with the chassis in 19 rack.
19 rack mountable splitter module can be used with the ber distribution unit (FDU series), the fusion splice termination box, and the cable
holder in 19 rack in order to cover most of the applications in the ber distribution networks.
19 rack mountable splitter module (3U)
Splitter module rack( for FSC-116 ) Splitter module rack( for FSC-110 )
FSC-116 series
FSC-110 series
FDU-96F-A Fusion splice termination box
(Sliding tray type)
Cable holder
42
Notes
19 rack mountable splitter module
Ordering Information
Specications
Product Code
FSC-116- X -SC / Y *
FSC-110- X -SC / Y
Technical characteristics ITU-T L.51 complied
Vibration
IEC61300-2-1
A=5mm, f=10Hz, 1,000,000 Cy, No splice case degradation. No damage.
Cable torsion
IEC61300-2-5
400mm, Maximum rotation 90/maximum 50 Nm, 5Cy/cable. No splice case degradation.
Temperature cycling IEC61300-2-22 -40C-20C-65C, 8h/Cy 100Cy. No splice case degradation No damage.
Optical characteristics
Parameter 1x2 1x4 1x8 1x16 1x32 1x64 2x4 2x8 2x16
Fiber Singlemode
Operating Wavelength [nm] 1,290 - 1,330, 1480-1500, 1530-1570
Splitter Module
Insertion Loss [dB] 4.3 8.0 11.6 14.9 18.4 22.1 8.1 11.7 15.0
Uniformity [dB]* 0.9 2.0 1.0 1.5 2.0 3.0 2.0 1.2 1.5
Return Loss [dB] 50 (UPC,APC)
Connector Type SC/APC (Green) or SC/UPC (Blue); Compliant with IEC 61754-4
*Except connector loss uniformity
Splitter module rack (for FSC-110)
Type 1x2 1x4 1x8 1x16 1x32 1x64 2x4 2x8 2x16
Module Capacity 18 9 4 n/a 18 9
Dimension (mm) WxHxD 482.6 x 132.6 x 48.0
Splitter module rack (for FSC-116)
Type 1x2 1x4 1x8 1x16 1x32 1x64 2x4 2x8 2x16
Module Capacity 36 18 36
Dimension (mm) WxHxD 482.6 x 132.6 x 114.0
Connector type :
UPC : UPC adapter
APC : APC adapter
*Please specify cord length (m)
Splitter type :
1x2 : 1x2 splitter
1x4 : 1x4 splitter
1x8 : 1x8 splitter
1x16 : 1x16 splitter
1x32 : 1x32 splitter
1x64 : 1x64 splitter
2x4 : 2x4 splitter
2x8 : 2x8 splitter
2x16 : 2x16 splitter
UP to 32 branching is available for FSC-110 series.
43
Latest information also available on the internet
URL : www.fujikura.co.jp
For Enquiry
Email :
[email protected]
Features
FSC114 series Wall mountable compact splitter module are
designed for FTTH MDU solution.
Can be direct mounted on the wall, or elevator shaft
Can accommodate Fujikuras termination boxes for the changing
needs of optical networks.
FSC114 series
Wall mountable Compact Splitter Module SC for FTTH MDU solution.
28.4
19.4
105
55
5
32
35.1
28.8
105
57
5
32
Structure
FSC114-1X4SC FSC114-1X8SC
Applications
Wall mountable compact splitter module is suitable for 1x4 splitting or 1x8 splitting , which can cover most of the applications in the ber
distribution networks like Fiber To The Home (FTTH), especially for MDU solution.
Wall mountable compact splitter module can be accommodated with the termination boxes.
FSCO-PM-MDU-SP-Box FSCO-PM-2SPMDU
Wall mount box 1:8 Splitter Module SC/APC(ForMDF) FSCO-PM with 1:8 Splitter Module SC/APC(ForMDF)
FSC114-1x4-SC/APC
FSC114-1x4-SC/UPC
FSC114-1x8-SC/APC
FSC114-1x8-SC/UPC
OPTICAL COMPONENTS
OPTICAL FIBERS OPTICAL CABLES MONITORING / MANAGEMENT SYSTEM
44
Notes
FSC114 series
Ordering Information
Specications
Type of Connector :
APC : Angled PC
UPC : UPC
Type of Splitter :
4 : 1 x 4 splitter
8 : 1 x 8 splitter
Product Code
FSC114-1X X SC/ Y
Physical characteristics
Material Molded plastic
Dimension
1x4 : L 105mm x W 29mmx H 55mm
1x8 : L 105mm x W 36mmx H 57mm
Weight (without kit) 0.2 kg
Technical characteristics ITU-T L.51 complied
Vibration
IEC61300-2-1
A = 5 mm, f = 10Hz, 1,000,000 Cy, No splice case degradation. No damage
Cable torsion
IEC61300-2-5
400 mm, Maximum rotation 90/maximum 50 Nm, 5Cy/cable. No splice case degradation.
Temperature cycling
IEC61300-2-22
-40C-20C-65C, 8h/Cy 100Cy. No splice case degradation No damage.
Item 1 x 4 Splitter Module 1 x 8 Splitter Module
Wavel length 1310 20 nm, 1550 20nm
Insertion loss 8.0 dB 11.6 dB
Uniformity 2.0 dB 1.0 dB
Return loss 50 dB 50 dB
Operating temperature / Humidity - 10 ~ + 40C, 90 %Rh
Except connector uniformity
45
Latest information also available on the internet
URL : www.fujikura.co.jp
For Enquiry
Email :
[email protected]
Features
FSCO-PM wall mountable Splice Closures are designed for aerial, strand-
mount FTTH drop locations where drop cables are spliced to distribution
cables.
These closures combine grommet cable sealing technology and splice & SC
adapter tray in a strong outer body
These closures are compatible with all loose buffer tube and central core
tube
Sleeve with hexagon socket bolt locking mechanism which makes
dismantling/assembling easy
Accommodate SC eld terminated Drop Cables installation.
Compatible with most cable types.
Fully mechanical design, ber reinforced plastic or equivalent
Recommendation of life span for 15 to 20 years (depends on environment).
Concept of separate cable entries system.
Compatible with Fujikuras optical splitter trays for the changing needs of
optical networks.
Removable splice tray holder available for convenient aerial splicing.
Laser caution signs provided on cover of the top tray.
Flipped opened and stackable tray available.
Main Cable
Through Fiber
Branching Cable
Drop Cable
Field installable
connector
Fusion Splice
Applications
Wall mountable Closure is suitable for up to 48 single ber splicing,
which can cover most of the applications in the ber distribution
networks like Fiber To The Home / Fiber To The Curb (FTTH/FTTC) .
Pole mount application is possible with pole mount option,
Butt, Mid-span access, and Taut Sheath conguration are used. In
addition, wall mount, pole mount application with indoor/outdoor are
possible.
FSCO-PM
Wall mountable Optic Closures for Drop point
(
3
1
7
)
(
1
4
1
)
(202)
Structure
Overview of FSCO-PM
External View Internal View (Wiring)
OPTICAL COMPONENTS
OPTICAL FIBERS OPTICAL CABLES MONITORING / MANAGEMENT SYSTEM
46
Notes
Physical characteristics
Material
Molded plastic
Stainless steel
EPDM
Dimension H 317mm x W 202mmx D 141mm
Weight (without kit) 1.2kg
Cable diameter
Main cable
Branch cable
Drop cable
11 - 15 mm dia.
11 - 15 mm dia.
2 x 3 mm
Through ber capacity 1.5m x 8 tubes (2.4mm Loose tube)
Cable ports
2 for main cable
1 for branch cable
16 for Drop or Indoor Cable/w friction cable)
Splitter tray capacity 1 tray
Splice tray capacity 1 tray
Maximum ber storage
capacity
Single ber 24 ber / tray
No. of splitter 1x4:4pcs or 1x8:2pcs or 1x16:1pcs
FSCO-PM
Technical characteristics ITU-T L.13 complied
Vibration
IEC61300-2-1
A=5mm, f=10Hz, 1,000,000 Cy, No splice case degradation.
No damage.
Cable xture(bend)
IEC61300-2-37
400mm, 30 bending or max. 500 N, 5Cy/cable. No splice
case degradation. No damage.
Cable torsion
IEC61300-2-5
400mm, Maximum rotation 90/maximum 50 Nm, 5Cy/cable.
No splice case degradation.
Temperature cycling
IEC61300-2-22
-40C-20C-65C, 8h/Cy 100Cy. No splice case degradation No
damage.
Impact(free drop)
IEC61300-2-12
0.75m @-15C & +45 C. No splice case degradation.
Degrees of protection
(IP Code) IEC 60529
IP55 : Wind driven rain proof & no effective by dust.
Salt mist
IEC61300-2-26
5% NaCl for 5days, without rust. No damage.
Re-entries
IEC61300-2-33
At least 1 thermal cycle to repeat Open & Close the closure
sleeve 10 times. No damage.
Ordering Information
Specication
X1; Model type
CC : SC adapter connecting type
FS : Fusion splice type (Adaptor not equipped)
X2; Splitter module
0SP : No splitter module inside
4SP : 1x4 splitter module inside
8SP : 1x8 splitter module inside
16SP : 1x16 splitter module inside
2(8SP) : 1x8 splitter module x 2set inside
X3; Adapter type
SC4 : 4xSC/PC
SC8 : 8xSC/PC
SC12 : 12xSC/PC
SC16 : 16xSC/PC
SCA4 : 4xSC/APC
SCA8 : 8xSC/APC
SCA12 : 12xSC/APC
SCA16 : 16xSC/APC
Product Code
FSCO-PM- X1 / X2/ X3
47
Latest information also available on the internet
URL : www.fujikura.co.jp
For Enquiry
Email :
[email protected]
Features
FSCO-AS Aerial Weathertight Splice Closures are designed for aerial,
strand-mount FTTH drop locations where drop cables are spliced to
distribution cables.
These free breathing closures combine grommet cable sealing technology
and splice tray, the splitter module is also available.
FSCO-AS Aerial Weathertight Splice Closures are suitable for special feature
with SSW cable.
Closure adopts hinge/buckle mechanism which makes dismantling/
assembling easy
Cable entry section can accommodate 1 main cable with up to 16c SSW
cable.
Can accommodate up to 8 drop cables.
Convenient attachable splitter module with 1:8 splitter module & 1:4
splitter module for drop cable installation.
Re-useable grommet sealing open and close easily for adding or removing
drop cables providing efcient cable installation with no mess.
Applications
FSCO-AS Aerial Weathertight Splice Closures is suitable for up to 8 drop cable splicing, which can cover most of the applications in the premise
wiring networks like Fiber To The Home (FTTH) .
Aerial application is possible with this closure. FSCO-AS has chemical and mechanical resistance for all the aerial application areas in the ber
networks.
Structure
Splice type Splitter module type
FSCO-AS
Aerial Weathertight Fiber Optic Splice Closures
(387)
(70)
(
1
0
7
.
5
)
(
1
2
4
)
COVER
LATCH BASE BODY
(43)
(387)
(
1
0
7
.
5
)
(
1
2
6
)
Latch
End plate
Cover
Base body
Pass through fibers
SSW aerial cable
Splice point
Drop Cable
Drop cable
Main body
Bare fiber operation area
SC adapter connection
SSW aerial cable
Splice point
1:8 splitter
Drop cover
Non bare fiber operation area
OPTICAL COMPONENTS
OPTICAL FIBERS OPTICAL CABLES MONITORING / MANAGEMENT SYSTEM
48
Notes
Physical characteristics
Material Molded plastic
Dimension L 387mm x W 70mmx H 124mm( Splitter module type )
Weight (without kit) 0.8 kg
Cable diameter
Main cable SSW aerial optical cable: 1pc
Drop cable 2 x 3 mm : up to 8pc
Cable ports 2 for main cable
Maximum ber storage
capacity
Single-ber 12 splices points
No. of optical adapter Max.8xSC adapter with 1x8 splitter module.
FSCO-AS
Technical characteristics ITU-T L.13 complied
Vibration
IEC61300-2-1
A=5mm, f=10Hz, 1,000,000 Cy, No splice case degradation.
No damage.
Cable xture(bend)
IEC61300-2-37
Bending radious:15mm, 90 bending, 3Cy/cable. No splice
case degradation. No damage.
Cable retention
IEC61300-2-4
Mina cable : 98N Drop cable : 49N. No splice case
degradation.
Temperature cycling
IEC61300-2-22
-20C-20C-60C, 8h/Cy 100Cy. No splice case degradation No
damage.
Impact(free drop)
IEC61300-2-12
0.75m @-15C & +45 C. No splice case degradation.
Degrees of protection
(IP Code) IEC 60529
IPX4 Protected against Wind driven rain proof.
(option :IP54 Wind driven rain proof & no effective by dust.)
Salt mist
IEC61300-2-26
5% NaCl for 5days, without rust. No damage.
Re-entries
IEC61300-2-33
At least 1 thermal cycle to repeat Open & Close the closure
sleeve 10 times. No damage.
Ordering Information
Specications
Connector type
Null : UPC adapter
A : APC adapter
Splitter type
Example:
4SP : 1 x 4 splitter module
8SP : 1 x 8 splitter module
Product Code
FSCO-AS- X / Y
FSCO-AS
Splice type
49
Latest information also available on the internet
URL : www.fujikura.co.jp
For Enquiry
Email :
[email protected]
Features
FSCO-AX Aerial Weathertight Splice Closures are designed for aerial,
strand-mount FTTH drop locations where drop cables are spliced to
distribution cables.
These free breathing closures combine grommet cable sealing technology
and splice tray in a strong, rodent proof outer body.
FSCO-AX Aerial Weathertight Splice Closures are designed for FTTH mid
span jointing with SZ slotted core cable with ribbon tape.
Closure adopts hinge/buckle mechanism which makes dismantling/
assembling easy
Cable entry section can accommodate 1 cables (main cable 1pcs) as the
mid span jointing.
Can accommodate up to 16 drop cables.
Outer body can be completely removed for 360 degree splice access.
Re-useable grommet sealing open and close easily for adding or removing
drop cables providing efcient cable installation with no mess.
Removable splice tray holder available for convenient aerial splicing.
Can accommodate Fujikuras optical splitter into trays for the changing
needs of optical networks.
Pass through fibers Cable slot
SSW aerial cable
Splice point
Drop Cable
Applications
Closure is suitable for up to 16 single ber splicing, which
can cover most of the applications in the ber distribution
networks like Fiber To The Home (FTTH).
Aerial application is possible with this closure. FSCO-AX has
chemical and mechanical resistance for all the aerial
application areas in the ber networks. In-ling, Mid-span
access, and Taut Sheath conguration are used.
Structure
FSCO-AX
Aerial Weathertight Fiber Optic Splice Closures
1
5
0
3
83
3
545
5
Sleeve Slack tray (9pcs)
End plate
Aerial hanger
Cable clamp
FSCO-AX
OPTICAL COMPONENTS
OPTICAL FIBERS OPTICAL CABLES MONITORING / MANAGEMENT SYSTEM
50
Notes
FSCO-AX
Ordering Information
Specications
Connector type
Null : UPC adapter
A : APC adapter
Splitter type
Example:
4SP : 1 x 4 splitter module
8SP : 1 x 8 splitter module
Product Code
FSCO-AS- X / Y
FSCO-AX
Splice type
Physical characteristics
Material
Molded plastic
ADC
Stainless steel
Dimension L 550mm x W 85mmx H 150mm
Weight (without kit) 2 kg
Cable diameter Main cable 8 15 mm dia.
Drop cable 2 x 3 mm
Cable capacity 1 6
Cable ports
2 for main cable
16 for branch cable (up to 4 port for Drop Cable optional)
Splice tray capacity Max. 9 trays
Maximum ber storage
capacity
Single ber 18 ber (2 ber/tray)
4-ber ribbon 36 ber (1 ribbon/tray)
Technical characteristics ITU-T L.13 complied
Vibration
IEC61300-2-1
A=5mm, f=10Hz, 1,000,000 Cy, No splice case degradation.
No damage.
Cable xture(bend)
IEC61300-2-37
400mm, 30 bending or max. 500 N, 5Cy/cable. No splice
case degradation. No damage.
Cable torsion
IEC61300-2-5
400mm, Maximum rotation 90/maximum 50 Nm, 5Cy/cable.
No splice case degradation.
Temperature cycling
IEC61300-2-22
-40C-20C-65C, 8h/Cy 100Cy. No splice case degradation No
damage.
Impact(free drop)
IEC61300-2-12
0.75m @-15C & +45 C. No splice case degradation.
Degrees of protection
(IP Code) IEC 60529
IP54 Protected against splashing water & no effective by dust.
Salt mist
IEC61300-2-26
5% NaCl for 5days, without rust. No damage.
Re-entries
IEC61300-2-33
At least 1 thermal cycle to repeat Open & Close the closure
sleeve 10 times. No damage.
51
Latest information also available on the internet
URL : www.fujikura.co.jp
For Enquiry
Email :
[email protected]
Features
FSCO-AO Aerial Weathertight Splice Closures are designed for aerial,
strand-mount FTTH drop locations where drop cables are spliced to
distribution cables.
These free breathing closures combine grommet cable sealing technology
and splice tray, SC adapter tray in a strong, rodent proof outer body.
FSCO-AO Aerial Weathertight Splice Closures are compatible with all loose
buffer tube and central core tube
Closure adopts hinge/buckle mechanism which makes dismantling/
assembling easy
Cable entry section can accommodate maximum 6 cables (main cable
2pcs, branching cable 4pcs)
Can accommodate up to 32 drop cables. (option)
Convenient pull-out SC adapter module for drop cable installation.
Compatible with most cable types.
Outer body can be completely removed for 360 degree splice access.
Re-useable grommet sealing open and close easily for adding or removing
drop cables providing efcient cable installation with no mess.
Removable splice tray holder available for convenient aerial splicing.
Compatible with Fujikuras optical splitter trays for the changing needs of
optical networks.
Fusion Splice
Connector
Branching Cable
Drop Cable
Through Fiber
Main Cable
Main Cable
Applications
Closure is suitable for up to 120 single ber splicing, which can cover
most of the applications in the ber distribution networks like Fiber
To The Home / Fiber To The Curb (FTTH/FTTC) .
Aerial application is possible with this closure. FSCO-AO has
chemical and mechanical resistance for all the aerial application
areas in the ber networks. In-Line, Butt, Mid-span access, and Taut
Sheath conguration are used.
Structure
FSCO-AO
Aerial Weathertight Fiber Optic Splice Closures
Packing sealing
Drop cable clamp SC Adapter module
Splice tray
Sleeve
(620) (150)
(200)
Cable clamp
Splitter tray
TM clamp
OPTICAL COMPONENTS
OPTICAL FIBERS OPTICAL CABLES MONITORING / MANAGEMENT SYSTEM
52
Notes
Physical characteristics
Material
Molded plastic
ADC
Stainless steel
Dimension L 620mm x W 150mmx H 200mm
Weight (without kit) 4 kg
Cable diameter
Main cable 8.5 - 28 mm dia.
Branch cable 8.5 - 28 mm dia.
Drop cable 2 x 3 mm
Cable capacity 1 6
Cable ports
2 for main cable
4 for branch cable (up to 4 port for Drop Cable optional)
Splice tray capacity Max. 10 trays
Maximum ber storage
capacity
Single ber 120 ber (12 ber/tray)
4-ber ribbon 200 ber (10 ribbon/tray)
No. of optical adapter Max. 16x SC adapter
FSCO-AO
Technical characteristics ITU-T L.13 complied
Vibration
IEC61300-2-1
A=5mm, f=10Hz, 1,000,000 Cy, No splice case degradation.
No damage.
Cable xture (bend)
IEC61300-2-37
400mm, 30 bending or max. 500 N, 5Cy/cable. No splice
case degradation. No damage.
Cable torsion
IEC61300-2-5
400mm, Maximum rotation 90/maximum 50 Nm, 5Cy/cable.
No splice case degradation.
Temperature cycling
IEC61300-2-22
-40C-20C-65C, 8h/Cy 100Cy. No splice case degradation No
damage.
Impact (free drop)
IEC61300-2-12
0.75m @-15C & +45 C. No splice case degradation.
Degrees of protection
(IP Code) IEC 60529
IP54 Protected against splashing water & no effective by dust.
(option :IP55 Wind driven rain proof & no effective by dust.)
Salt mist
IEC61300-2-26
5% NaCl for 5days, without rust. No damage.
Re-entries
IEC61300-2-33
At least 1 thermal cycle to repeat Open & Close the closure
sleeve 10 times. No damage.
Ordering Information
Specication
Tray type and qty
Example :
HD4 : 4 slack trays
Connector type
SC8 : 8xSC/UPC adapter w/ 1 drop clamp module
SC16 : 16xSC/UPC adapter w/ 2 drop clamp modules
SCA8 : 8xSC/APC adapter w/ 1 drop clamp module
SCA16 : 16xSC/APC adapter w/ 2 drop clamp modules
Drop cable installable
(with drop cable clamp)
Product Code
FSCO-AO / X / Y / D
(
/CPL
)
With Coupler tray
53
Latest information also available on the internet
URL : www.fujikura.co.jp
For Enquiry
Email :
[email protected]
Features
Cable entrance conguration is In-line, which is suitable for space
constrained hand holes (also possible to be used in man-holes, telephone
tunnels and aerial, etc)
Closure adopts band mechanism, which makes dismantling/assembling
easy.
Cable entry section can accommodate maximum 4 cables (main cable 2pcs,
branching cable 2pcs)
Supports loose tube cable and slotted core cable.
Fusion Splice
Branching Cable
Branching Cable
Main Cable
Applications
Closure is suitable for up to 72 single ber splicing, which can cover
most of the applications in the ber distribution networks like Fiber
To The Home / Fiber To The Curb (FTTH/FTTC). Underground, aerial,
or pedestal applications are possible with this closure.
Structure
FSCO-CB Structure
FSCO-CB
Sealed Fiber optic splice Closure
CABLE CLAMP
END SEAL TAPE
SLEEVE HALVES
BAND
TRAY (max.6)
TENSION MEMBER CLAMP
A
EARTH TERMINAL
GAS VALVE
A
A-A
Hinges of tray
1
2
6
1
4
0
340
A
Lock patr of tray
SLEEVE GASKET
OPTICAL COMPONENTS
OPTICAL FIBERS OPTICAL CABLES MONITORING / MANAGEMENT SYSTEM
54
Notes
Physical characteristics
Material
Molded plastic (Sleeve, Splice tray)
Stainless steel (Band), Anti-rusted steel (Connecting bar,
Organiser)
synthetic rubber (Sleeve gasket, end seal tape)
Dimension L 340mm x W 140mm x H 126mm
Weight (without kit) 2 kg
Cable diameter 8 - 21 mm dia.
Cable capacity 1 4
Cable ports
2 for main cable
2 for branch cable
Splice tray capacity Max. 6 trays
Maximum ber storage Single ber 72 ber (12 ber/tray)
Capacity (BH Tray) 4-ber ribbon 120 ber (5 ribbon/tray)
Un-reusable parts End seal tape, Sleeve gasket, Sealing washer
FSCO-CB
Technical characteristics ITU-T L.13 complied
Vibration
IEC61300-2-1
49kPa, A=5mm, f=10Hz, 1,000,000 Cy,
No damage, No leakage.
Cable xture (bend)
IEC61300-2-37
49kPa, 90bending radius 6D, 6Cy.
No damage, No leakage.
Cable torsion
IEC61300-2-5
49kPa, 400mm, 90 degree, -15C and 45C, 5Cy.
No damage, No leakage.
Cable axial tension
IEC61300-2-4
49kPa, D/45 x 1000N (Max.1000N), 1hr
No leakage
Temperature cycling
IEC61300-2-22
-20C ~ 60C, 8h/Cy 100Cy. Then ll 49kPa air-pressure,
No leakage.
Impact
IEC61300-2-12
0.5kg, 0.3m @-10C.
No damage, No splice case degradation.
Immersion
IEC61300-2-23
Water depth 5m, 7days,
No water intrusion.
Air tightness
IEC61300-2-38
49kPa@Room temperature, 15min.
No leakage.
Degrees of protection
(IP code) IEC60529
IP67 : Water proof and No effective by duct
Compression
IEC61300-2-10
1000N, 25cm2, 10min, -15C and 45C
No leakage
Chemical Resistance
IEC61300-2-34
pH2, pH12 for 5 days.
No leakage, Visual appearance.
Rust resistance
IEC61300-2-26
Salt spray 5% NaCl for 5days, No rust
Ordering Information
Specications
Tray type BH or BL
Number of slack Tray (1~6)
Presence of gas valve and
earth terminal
(Yes:2 No:1)
Product Code
FSCO-CB / ** / X / Y / Z / <a1><a2><b1><b2>
Cable size
Cable diameter D (mm)
The size of cable clamp
and sealing washer
8 D 11 S
11 D 16 M
16 D 21 L
End packing E
Presence of optional parts
(Yes:2 No:1)
Option
C sleeve Fro FRP tension member use. Please order when Non-metallic cable installation
Re-entry kit End seal tape 4pcs, Sleeve gasket 2pcs
Cable kit Size S, M, L for additional branching cable
55
Latest information also available on the internet
URL : www.fujikura.co.jp
For Enquiry
Email :
[email protected]
Features
Cable entry section is single-sided pot structure which is suitable for space
constrained hand holes (also possible to be used in man-holes, telephone
tunnels etc)
Closure adopts hinge/buckle mechanism which makes dismantling/
assembling easy
Cable entry section can accommodate maximum 8 cables (main cable 2pcs,
branching cable 6pcs)
Can accommodate up to 32 drop cables. (option)
Supports loose tube cable, slotted core cable, drop cable.
Suitable for application in areas with limited space applications, too. (hand
holes)
Applicable for all networks. FTTH /FTTC solutions.
Fully mechanical design, ber reinforced plastic or equivalent
Recommendation of life span for 15 to 20 years (depends on environment)
Concept of separate cable entries system
Laser caution signs provided on cover of the top tray
Size of splice tray smaller footprint than 5"x12"
360deg access permits complete access to all wirework and equipment
sleeve attaches securely to the base using a self-locking 216-hex head
bolt lock or equivalent
Main Cable
Through Fiber
Branching Cable
Drop Cable
Field installableconnector
Fusion Splice
Applications
Closure is suitable for up to 192 single ber splicing, which can cover
most of the applications in the ber distribution networks like Fiber
To The Home / Fiber To The Curb (FTTH/FTTC) .Underground, aerial,
or pedestal applications are possible with this closure.
FSCO-HHS has chemical and mechanical resistance for all the
application areas in the ber networks. Only butt conguration use.
Structure
FSCO-HHS
FSCO-HHS-CC/[ ]SP FSCO-HHS-FS/[ ]SP
FSCO-HHS
Sealed Fiber optic splice Closure
Band
End plate
Drop cable clamp
SC Adapter
Splice tray
214
278
214 316.3
278
316.3
TM clamp
Sleeve
Cable clamp
Band
End plate
Drop cable clamp
Splice tray
TM clamp
Sleeve
Cable clamp
OPTICAL COMPONENTS
OPTICAL FIBERS OPTICAL CABLES MONITORING / MANAGEMENT SYSTEM
56
Notes
Physical characteristics
Material
Molded plastic
Coated ADC as stainless equivalent
Stainless steel
EPDM
Dimension W 278mm x D 214mm x H 316mm
Weight (without kit) 4 kg
Cable diameter
Main cable 9 - 24 mm dia.
Branch cable 8 - 16 mm dia.
Drop cable 2 x 3 mm
Cable ports
2 for main cable
1 for branch cable
2 for Drop Cable
Splice tray capacity 2 trays
Maximum ber storage
capacity
Single ber 24 ber / tray
4-ber ribbon 40 ber (10 ribbons) / tray
Splitter 1 x 4 : 4pcs or 1 x 8 :2pcs or 1 x 16 : 1pcs
with max. 4 splices
No. of optical adapter Max.16 x SC adapter
FSCO-HHS
Technical characteristics ITU-T L.13 complied
Vibration 40kPa A=5mm, f=10Hz, 1,000,000 Cy, No splice case
degradation. No leakage.
Cable bend
40kPa, 300mm, 90degree, 6Cy. No splice case
degradation. No leakage.
Cable torsion 1000mm, 90 degree, 10Cy. No splice case degradation.
Rust resistance Salt spray for 30days, without rust
Temperature cycling
-20C-20C-60C, 8h/Cy 100Cy. Then ll 40kPa air-pressure,
without leakage.
Impact 0.5kg, 0.3m @-10C. No splice case degradation.
Immersion Water depth 4m, 24hrs, without water intrusion.
Air tightness
40kPa@Room temperature, 5min. No splice case
degradation. No leakage. IP67
Compression 980N, 1min, No splice case degradation.
Chemical Resistance pH2, pH12 for 5 days. Without corrosion.
Re-entry
Repeat Open & Close the closure 25times.
No greater than 0.1dB optical attenuation change
Ordering Information
Specication
Model type
CC : Connector connecting type
FS : Fusion Splice type
Product Code
FSCO-HHS- X1 / X2
Splitter module
0SP : No splitter inside(SC adaptor not equipped)
4SP : 1x4 splitter module inside(with 4pcs SC adaptor)
8SP : 1x8 splitter module inside(with 8pcs SC adaptor)
16SP : 1x16 splitter module inside(with 16pcs SC adaptor)
b1
b2
b3
b4
a1
a2
a3
a4
a1,b1 : for Main cable only
b2,b31 : for Drop cable only
b4 : for Branch cable only
a2,a3,a4 : No entty
Cable ently position
C sleeve Fro FRP tension member use. Please order when Non-metallic cable installation
Branch cable kit <HS> 1 set/1 cable for 8 - 6 mm dia.
Branch cable kit <HM> 1 set/1 cable for 16 - 19 mm dia.
Drop cable kit <D8> 1 set/8 cables for drop cables
Main cable end plate 1 pcs Necessary to entry one main cable only
Option
57
Latest information also available on the internet
URL : www.fujikura.co.jp
For Enquiry
Email :
[email protected]
Features
Cable entry section is single-sided dome structure which is suitable for
space constrained hand holes (also possible to be used in man-holes,
telephone tunnels etc).
Closure adopts hinge/buckle mechanism which makes dismantling/
assembling easy.
Cable entry section can accommodate maximum 6 cables (main cable 2pcs,
branching cable 4pcs).
Supports both loose tube cables and slotted core cables.
Suitable for use in limited space areas such as hand holes
Applicable for all networks. FTTH /FTTC solutions.
Fully mechanical design, ber reinforced plastic
Recommendation of life span for 15 to 20 years (depends on environment)
Concept of separate cable entries system
Laser caution signs provided on cover of the top tray
360-deg access permits complete access to all wirework and equipment
Main Cable
Main Cable
Through Fiber
Branching Cable
Fusion Splice
Applications
Closure is suitable for up to 192C (4-ribbon) ber splicing,
which can accommodate the requirements of most ber
distribution networks such as Fiber To The Home/Fiber To
The Curb (FTTH/FTTC). Suitable for underground, aerial and
pedestal installation.
FSCO-L5BR has chemical and mechanical resistance for all
the application areas in the ber networks.
Structure
FSCO-L5BR
Sealed Fiber Optic Splice Closure
194 230
Cover
Tray
Tension member clamp Cable clamp
Band
Valve
Cover gasket
435
OPTICAL COMPONENTS
OPTICAL FIBERS OPTICAL CABLES MONITORING / MANAGEMENT SYSTEM
58
Notes
FSCO-L5BR
Ordering Information
Specications
Type of ber capacity :
12C, 24C, 36C, 48C, 96C,
144C, 192C
Type of Closure : BR
(BR : Heat shrink tube type)
Number of holes cable :
5 holes
Product Code
FSCO - L5 BR / Y
Physical characteristics
Material
Molded plastic (Cover, Splice tray, Tray base, Pass case, End
plate, Cable clamping )
Stainless steel (Tension member clamp),
Synthetic rubber (Cover gasket, Valve gasket )
Dimension L 435mm x D230mm
Weight (without kit) Approx 3.7 kg
Cable diameter
8 17.5 mm dia.(Main cable:12-17.5 mm, Branch cable:8-17.5
mm)
Cable capacity Max. 6 cables
Cable ports
1 oval port for 2x main cables
4 round ports for branch cables
Splice tray capacity Max. 5 trays
Maximum ber storage
Capacity
Single ber 120 bers (24 ber/tray)
4-ber ribbon 200 bers (10 ribbon/tray)
Un-reusable parts Heat shrink tube, Branching clip
Technical characteristics ITU-T L.13 complied
Vibration
IEC61300-2-1
49kPa, A=5mm, f=10Hz, 1,000,000 Cy,
No damage, No leakage.
Cable xture (bend)
IEC61300-2-37
49kPa, 90bending radius 6D, 6Cy.
No damage, No leakage.
Cable torsion
IEC61300-2-5
49kPa, 400mm, 90 degree, -15C and 45C, 5Cy.
No damage, No leakage.
Cable axial tension
IEC61300-2-4
49kPa, D/45 x 1000N (Max.1000N), 1hr
No leakage
Temperature cycling
IEC61300-2-22
-20C ~ 60C, 8h/Cy 100Cy. Then ll 49kPa air-pressure,
No leakage.
Impact
IEC61300-2-12
0.5kg, 0.3m @-10C.
No damage, No splice case degradation.
Immersion
IEC61300-2-23
Water depth 5m, 7days,
No water intrusion.
Air tightness
IEC61300-2-38
49kPa@Room temperature, 15min.
No leakage.
Degrees of protection
(IP code) IEC60529
IP67 : Water proof and No effective by duct
Compression
IEC61300-2-10
1000N, 25cm
2
, 10min, -15C and 45C
No leakage
Chemical Resistance
IEC61300-2-34
pH2, pH12 for 5 days.
No leakage, Visual appearance.
Rust resistance
IEC61300-2-26
Salt spray 5% NaCl for 5days,
No rust
59
Latest information also available on the internet
URL : www.fujikura.co.jp
For Enquiry
Email :
[email protected]
Optical connectors and cable assemblies
SC Connector
Optical connectors
MU Connector
FC Connector
LC Connector
MTRJ Connector
MPO/LIGHTRAY MPX Connector
Item Content
Fiber Type
Single Mode Multi Mode
SM10/125 G50/125
DSM8/125 G62.5/125
Insertion Loss
(with master cord)
PC polish
Typical 0.2 dB
0.3dB
Ultra PC polish (UPC) -
Return Loss Ultra PC polish (UPC) Typical 55 dB -
Suitable Cord Type f 2 cord, f 0.9 ber
Conformity Standard IEC61754-6
( ) Available for "premium grade" with excellent insertion loss and return loss.
( ) Please enquire on the return loss for multi-mode ber if required.
Item Content
Fiber Type
Single Mode Multi Mode
SM10/125 G50/125
DSM8/125 G62.5/125
Connector Loss
(with master cord)
PC polish
Typical 0.2 dB
0.3dB
Ultra PC polish (UPC) -
Angled PC polish (APC) -
Return Loss
Ultra PC polish (UPC) Typical 55 dB -
Angled PC polish (APC) 60dB -
Suitable Cord Type f 2 cord, f 3 cord, f 0.9 ber
Conformity Standard JIS C5970(F01), IEC61754-13
( ) Available for "premium grade" with excellent insertion loss and return loss.
( ) Please enquire on the return loss for multi-mode ber if required.
Tight-Buffered Fiber Type
Item Content
Fiber Type
Single Mode Multi Mode
SM10/125 G50/125
DSM8/125 G62.5/125
Insertion Loss
(with master cord)
PC polish
Typical 0.2 dB
0.3dB
Ultra PC polish (UPC) -
Angled PC polish (APC) -
Return Loss
Ultra PC polish (UPC) Typical 55 dB -
Angled PC polish (APC) 60 dB -
Suitable Cord Type f 2 cord, f 3 cord, f 0.9 ber
Conformity Standard IEC61754-4
( ) Available for "premium grade" with excellent insertion loss and return loss.
( ) Please enquire on the return loss for multi-mode ber if required.
Item Content
Fiber Type
Single Mode Multi Mode
SM10/125 G50/125
DSM8/125 G62.5/125
Insertion Loss
(with master cord)
PC polish
Typical 0.2 dB
0.3dB
Ultra PC polish (UPC) -
Angled PC polish (APC) -
Return Loss
Ultra PC polish (UPC) Typical 55 dB
Angled PC polish (APC) 60 dB
Suitable Cord Type f 2 cord, f 0.9 ber
Conformity Standard TIA/EIA-604-10, IEC61754-20
( ) Available for "premium grade" with excellent insertion loss and return loss.
( ) Please enquire on the return loss for multi-mode ber if required.
Tight-Buffered Fiber Type
Item Content
Fiber Type
Single Mode Multi Mode
SM10/125 G50/125
DSM8/125 G62.5/125
Insertion Loss
PC polish
0.7dB 0.4dB
Return Loss 26dB -
Suitable Cord Type f 2 zipcord, f 2.8 dual-link cable
Conformity Standard TIA/EIA-604-12, IEC61754-18
MTRJF: Without guide pin MTRJM: With guide pin
( ) Please enquire on the return loss for multi-mode ber if required.
Dual-Link Cable Type
Item Content
Fiber Type Single Mode Multi Mode
Connector Loss
Standard Grade 1dB 0.5dB
Low-Loss Grade 0.35dB -
Return Loss 55dB -
Suitable Cord Type Fiber ribbon, Ribbon cord
Conformity Standard MPO: IEC61754-7
MPOF, MPXF: Without guide pin MPOM, MPXM: With guide pin
Singlemode type meets Telcordia GR-1435-CORE
( ) MPX: LIGHTRAY MPX is a trademark of The Whitaker Corporation
( ) Please enquire on the return loss for multi-mode ber if required.
MPX connector
Cord Type
Cord Type
Cord Type
MPO connector
OPTICAL COMPONENTS
OPTICAL FIBERS OPTICAL CABLES MONITORING / MANAGEMENT SYSTEM
60
Notes
Optical connectors and cable assemblies
Pigtails, Simplex and Duplex Cable Assemblies
Compatible with SC, FC and other types of single ber connectors.
Available in various cord sizes 0.9 (TBF), 1.6, 2 and 3 mm.
1 3 3
4
2 5 6 7
1
Lm
Optical Connector
Name
Differentiate Between
Single/Double Ended
Termination and Fiber
Type (SM or GI)
Polishing Method Product Length Fiber Type Fiber Size Cord Size
Shows the connector
type
Please indicate clearly
if different connectors
are required to be
terminated at both
ends (ex. FFC/FSC)
* Single-ended: 1
* Double-ended: 2
* GI:P
* SM:PS
* Spherical: PC
* Ultra PC:UPC
* Angled PC:APC
Please indicate clearly
if polishing is different
at both ends (ex. APC
/UPC)
* Unit in meter
* Tolerance
L 1m +10cm, -0
1m < L 10m +10%, -0
10m < L 50m +1m, -0
L > 50m +2%,-0
Cord
* GI:GC (Orange)
* SM: SMC (Yellow)
* DSM: DSMC (Yellow or
Orange)
Tight-Buffered Fiber
* GI:G
* SM:SM
* DSM:DSM
Please indicate core
diameter (mode eld
diameter)/clad diameter
* f2 simplex: S
* f3 simplex: Leave blank.
* f2 zipcord: 2SR
* f3 zipcord: 2R
* f1.6 simplex: SS
* f1.6 zipcord: 2SSR
Please refer to the Application Table for the relevant bers and cords for each type of connector.
Shape and color of connector boot may vary depending on the type of ber/cord and polishing method.
Please enquire on ame retardant type of cords.
Connector
Single Mode (SM/DSM) Multi-Mode
Polishing Method Suitable TBF/cord diameter Suitable Cord
Polishing
Method
Suitable TBF/cord diameter Suitable Cord
PC UPC APC 0.9 1.6 2 3 Simplex Duplex PC 0.9 1.6 2 3 Simplex Duplex
SC
FC
MU
LC
MTRJF
MTRJM
DXSC
DXMU
DXLC
FFC2PSUPCLMSMC10/125S
Product Code Interpretation
Application Table
Patchcords compliant with ISO/IEC 11801 and TIA/EIA-568-C.3 available for customer premises and
commercial building telecommunications cabling.
Simplex and zipcord cables meet TIA/EIA 568-C.3, Telcordia GR-409-CORE and Directive 2002/95/EC
(RoHS) and Plenum, Riser and OFNR-listed LSZH grade jackets available.
LSZH meets the requirement of IEC 61034-1, 61034-2, 60332-1-1,60332-1-2, 60754-1 and 60754-2.
OS1, OS2, bend-insensitive FutureGuide-SR15E (ITU-T G.657.A1), FutureGuide-BIS-B (ITU-T G.657.A2)
and ITU-T G.657.B3 ber for singlemode applications and OM1, OM2, OM3 and OM4 for multimode
applications available as options.
3 or 4 mm dia. ultra-exible cables (MageTsuyo) with FutureGuide-BIS-B (ITU-T G.657.A2) for FTTH
cabling available as options.
61
Latest information also available on the internet
URL : www.fujikura.co.jp
For Enquiry
Email :
[email protected]
Features
Mechanical splice connection makes use of mechanical splice unit
where 2 bers are rst inserted into the unit. The bers are next
aligned and then held in position by clamping parts.
Fast and Easy splicing of 250 or 900um SM/MM bers.
Power source not required, all necessary tools are provided in the
standard tool kit.
Much faster compared to fusion splicing method
Specications
Structure
Mechanical splice connection is done by using the mechanical splice
shown in Figure 1. Fibers are set to the V-groove of the mechanical
splice. The bers are hold in place by clamping with the clamping
parts. Index matching gel is added to the center of the mechanical
splice ( at the supposed connection point of the two bers) to ensure
good insertion and return loss.
Figure 2 and Figure 3 show the inner structure of the mechanical
splice. Both the 0.25mm section and 0.125mm (bare ber) section of
the ber are being clamped and held in position.Therefore, to ensure
good connection, both the ber stripping length and the ber
cleaved length must be controlled within specications.
Mechanical Splice Unit
Mechanical Splice
Single fiber Mechanical Splice
Mechanical splice
Wedge grooves
U-shape sleeve
Optical bers
Figure 1
Type Mechanical Splice Unit Remark
Product Code FMSEZ-025/09
Application Dia.0.25mm single ber or Dia.0.9mm single ber Cladding : 0.125mm Except Nylon coating bers
Applicable ber diameter range Dia.0.235mm to 0.265mm , Dia. 0.85mm to 0.95mm ITU-T compliance
Size L40 x W4 x H4 (mm)
Connection Loss Average < 0.1dB
Return Loss 40dB
Fiber Adhesion Force < 3N (Connection Loss change < 0.2dB)
Required Tools Single ber MS/EZ Assembly tool
Clamping parts (3 sections)
Index matching gel
Optical fiber (outercoat stripped,
0.125mm outer diameter)
Optical fiber
(0.25mm outer
diameter)
V-groove substrate
Clamping part
Optical fiber
U-shape sleeve
Used to clamp the
clamping parts and
V-groove substrate
together
Wedge
V-groove substrate
When wedge is inserted
into the mechanical splice,
the space at the V-groove
substrate is enlarged, allowing
fiber to be inserted into
the mechanical splice.
0.125mm bare fiber section
0.125mm bare fiber
(no outercoat:
fiber glass section) Connection point
0.25mm fiber section
Optical fiber holder
0.25mm fiber
inserted section
Inner structure of
mechanical splice
Figure 2-1 Figure 2-2 Figure 3
OPTICAL COMPONENTS
OPTICAL FIBERS OPTICAL CABLES MONITORING / MANAGEMENT SYSTEM
62
Notes
Single Fiber MS/EZ Assembly tool
Assembly Tool
Features
MS/EZ assembly tool for f0.25mm single optical ber.
Easier MS/EZ assembly than one with existing tool.
MS/EZ assembly tool for FMSEZ-025.
No electric power is required and assembly can be done quickly.
Suitable for FTTH drop cable solution.
MS/EZ assembly kit is also available.
MS/EZ Assembly tool
Mechanical Splice
1 2 3 4 5
Item Model No. Quantity Remarks
1 MS/EZ Assembly Tool FMSECO-TL2-EZ 1ea
2 Mechanical Stripper F FMSECO-MSTR025 1ea
3 Single Fiber HolderF FMSECO-FH05/025 10ea
4 Spacer for Mechanical Splice Spacer F FMSECO-SP-C2 2ea
5 Alcohol Bottle FMSEZ-ALC 1ea
Wiper - 1set
Instruction Manual - 1set
6 Carrying Case - 1set
7 Fiber Cleaver CT-30 - Option
8 Micro Stripper (f0.9) MS1-08S-40-FS - Option
9 Single Fiber HolderF(f0.9) (Instruction Manual Included) FMSECO-FH09 - Option
Single ber MS/EZ assembly tool (for f250um ber) is also available.
FMSEC0EZ-KIT025C-10 (without Fiber Cleaver)
FMSEC0EZ-KIT025C-11 (with Fiber Cleaver)
6 7 8 9
63
Latest information also available on the internet
URL : www.fujikura.co.jp
For Enquiry
Email :
[email protected]
OPTICAL COMPONENTS
OPTICAL FIBERS OPTICAL CABLES MONITORING / MANAGEMENT SYSTEM
Package Information
250um Fiber holder : 1pcs/10connectors
250um Fiber insert guide : 1pcs/10connectors
900um Fiber Holder : Order separately
1pcs of spacer/10connectors
1pcs of marker/10 connectors (only for APC interface connector)
FAST-Connector (UNI) Series (for 250um, 900um ber)
FAST-Connector
Before Assemble
Features
FAST-SC-UNI, FAST-LC-UNI has own design to clamp 250um and
900um coated bers. Both are fully compatible with the standard SC,
LC connectors and demonstrate the performance combining SC, LC
connectors and Mechanical Splices.
Fujikura has greatly simplied process of joining two bers, therefore
providing signicant support for our customers in the construction of FTTH
network. Fujikura FAST connector is a series of eld-installable connectors,
which require no polishing. Unlike conventional eld-installable connectors,
FAST connector series do not employ assembling tool but incorporate its
own pre-assembled wedge launcher. The pre-assembled wedge launcher is a
disposal part after installing ber. Fujikura FAST connector uses a mechanism
of Push-pull-wedge, which has been introduced by Fujikuras Mechanical
Splices. As the Push-pull-wedge mechanism achieves clamping both bare
ber part and coating part, this clamping mechanism enhances strength
against ber twist.
Item Content
Applicable ber diameter
240 ~ 265 um (for 250um ber),
850 ~ 950 um (for 900um ber)
Fiber Polishing Method UPC Polish, APC Polish
Connection Loss
(wrt master)
< 0.5dB (Singlemode)
< 0.6dB (Singlemode APC Polish)
< 0.4dB (Multimode)
Return Loss
> 45dB (SM ber UPC polish)
> 65dB (SM ber APC polish / When use with Angled cleaver)
> 50dB (SM ber APC polish / When use with Flat cleaver)
Working temperature
-40C ~ 75 C (for 250um ber)
Base on ber spec (for 900um ber)
Specication
Specications
Type
Product Code
FAST-SC FAST-LC FAST-ST
Singlemode UPC Polish FAST-SC-SM-UNI/00-BL/BK FAST-LC-SM-UNI/00-BL/BK FAST-ST-SM-UNI/00-BL/BK
Singlemode APC Polish FAST-SC-APC-SM-UNI/00 - -
50/125 Multimode FAST-SC-GI5-UNI/00-BK/BK FAST-LC-GI5-UNI/00-BK/BK FAST-ST-GI5-UNI/00-BK/BK
62.5/125 Multimode FAST-SC-GI6-UNI/00-BG/BK FAST-LC-GI6-UNI/00-BG/BK FAST-ST-GI6-UNI/00-BG/BK
MM10G FAST-SC-10G-UNI/00-AQ/BK FAST-LC-10G-UNI/00-AQ/BK FAST-ST-10G-UNI/00-AQ/BK
Interior Structure Cross-sectional View
Polished Optical ber is pre-afxed at the tip of the connector and
stripped ber is cleaved and aligned until it touches the built-in ber,
where connection is done via mechanical splice method
Pre-installed Fiber
Refractive
Index Matching Gel
Inserted Fiber
Stripped Fiber
Securing Clamp
Bare Fiber
Securing Clamp
Ferrule
Wedge
Fiber
250um ber
insert guide
250um ber
holder
Marker 900um ber
insert guide
After Assemble
Assembly Flow
1. Prepare ber 3. Remove connector unit from
the wedge launcher
2. Insert ber into connector body
and conrm ber bend
4. Insert the boots
Approx. 10mm
Coating part Glass
64
Latest information also available on the internet
URL : www.fujikura.co.jp
For Enquiry
Email :
[email protected]
FAST-Connector Cord series (for 2mm & 3mm)
FAST-Connector
Before Assemble
Features
FAST-SC-09/CO FAST-LC-09/CO have own design to clamp 2mm,
and 3mm cord. Both are fully compatible with the standard SC, LC
connectors. Therefore, FAST-SC, FAST-LC demonstrates the
performance combining SC, LC connectors and Mechanical Splices.
Item Content
Applicable Cord Diamer f 2mm (for 2mm cord), f 3mm (for 3mm cord)
Fiber Polishing Method UPC Polish, APC Polish
Connection Loss
(wrt master)
< 0.5dB (Singlemode)
< 0.6dB (Singlemode APC Polish)
< 0.4dB (Multimode)
Return Loss
> 45dB (SM ber UPC polish)
> 65dB (SM ber APC polish / When use with Angled cleaver)
> 50dB (SM ber APC plish / When use with Flat cleaver)
Fiber Retention Force Cord : <68.6N
Specication
After Assemble
FAST-Connector
Package Information
Assembly Tool : 1pc/50connector
2 Cable Clamp :1pc / 50 connectors
3 Cable Clamp : 1pc / 50 connectors
1pc of spacer/10 connectors
1pc of marker/10 connectors (only for APC interface connector)
Specications
Type
Product Code
FAST-SC FAST-LC FAST-ST
Singlemode UPC Polish FAST-SC-SM-09/CO FAST-LC-SM-09/CO FAST-ST-SM-09/CO
Singlemode APC Polish FAST-SC-APC-SM-09/CO - -
50/125 Multimode FAST-SC-GI5-09/CO FAST-LC-GI5-09/CO FAST-ST-GI5-09/CO
62.5/125 Multimode FAST-SC-GI6-09/CO FAST-LC-GI6-09/CO FAST-ST-GI6-09/CO
MM10G FAST-SC-10G-09/CO FAST-LC-10G-09/CO FAST-ST-10G-09/CO
Assembly Tool f 2 Cable Clamp Marker f 3 Cable Clamp
Assembly Flow
Approx. 16mm
Marking
Approx. 10mm
1. Secure cord using cable clamp 3. Set connector and cord onto
assembly tool and insert ber
to connector
6. Tighten boot, remove
connector from assembly tool
and trim aramid yarn
2. Remove outer jacket and strip 4. Make bend and disengage
Wedge Unit
5. Fix aramid yarn
300mm
65
Latest information also available on the internet
URL : www.fujikura.co.jp
For Enquiry
Email :
[email protected]
FAST-Connector (for Drop/Indoor Cable/Low Friction Indoor Cable)
FAST-Connector
Before Assemble
Features
FAST-SC-GT type has own design to clamp drop cable or indoor
cable and low friction indoor cable. FAST-SC is fully compatible with
the standard SC connectors. Therefore, FAST-SC demonstrates the
performance combining both SC connectors and Mechanical
Splices.
Item Content
Applicable Cable Diamer
3.1 0.2mm x 2.0 0.2mm (Drop/Indoor Cable)
2.0 0.1mm x 1.6 0.1mm (Low Friction Indoor Cable)
Fiber Polishing Method UPC Polish, APC Polish
Connection Loss
wrt master)
< 0.5dB (Singlemode)
< 0.6dB (Singlemode APC Polish)
< 0.4dB (Multimode)
Return Loss
> 45dB (SM ber UPC polish)
> 65dB (SM ber APC polish / When use with Angled cleaver)
> 50dB (SM ber APC plish / When use with Flat cleaver)
Fiber Retention Force > 20N (<0.2dB with impressed pressure)
Specication
After Assemble
Assembly Flow
1. Secure cable using with
matching cable clamp &
holder
3. Disengage Wedged unit 2. Insert ber and conrm ber
bend
4. Down the lever and x cable
Approx.
15mm
Approx.
10mm
Package & Product Code Information
Item Product Code Item 1 Item 2 Item 3
Drop/Indoor Cable, UPC Polish FAST-SC-SM-025/GT
Drop/Indoor Cable, APC Polish FAST-SC-APC-SM-025/GT
Low Friction Indoor Cable, UPC Polish FAST-SC-SM-LF/GT
Low Friction Indoor Cable, APC Polish FAST-SC-APC-SM-LF/GT
Item 1 :
Green Cable holder
1pc/10 connectors
Item 2 :
Blue Cable Clamp
1pc/connector
Item 3 :
Yellow Cable Clamp
1pc/connector
All package contain 1pcs of spacer/10 connectors
66
No. Name Model Purpose
KIT
(A)
KIT
(B)
KIT
(C)
KIT
(D)
KIT
(E)
1 Optical ber holder 025 FMSECO-FH05/025 To assemble FAST-SC for 250um ber
2 Cable Holder - To assemble FAST-SC(GT)
3 Mechanical Stripper 025 FMSECO-MSTR025 To strip 250um ber
4 Micro Stripper 09 MS1-08S-40-FS To strip 900um ber
5 Alcohol Container FMSEZ-ALC -
6 Cotton Pad - -
7 High Precision Cleaver CT-30 + HBA01 Flat Cleaving
8 Fiber Plates AD-30A To adjust bare ber length Option
9 Spacer FMSECO-SP-C2 To adjust bare ber length
10 250um ber insert tool - To assemble FAST-SC for 250um ber
11 Carrying Case - -
12 Cordage Assembly tool FAST-SC-KIT-CO To assemble cordage
13 f 2mm Cable Clamp FAST-SC-KIT-CO To assemble f 2mm cordage
14 f 3mm Cable Clamp FAST-SC-KIT-CO To assemble f 3mm cordage
15 Angled Cleaver CT-11
Angled Cleaving
To get high return loss
* Kit(A) ; FAST-SC-KIT025DR-10, Kit(B) ; FAST-SC-KIT025DR-11 , Kit(C) ; FAST-SC-KIT/ALL-10, Kit(D) ; FAST-SC-KIT/ALL-11,
KIT(E) ; FAST-SC/APC-KIT/ALL-11
Notes
Features
Industry standard ber preparation tools
Compact design, exible but rugged case
Complete instructions provided
The FAST Connector Assembly Tool Kit provides all the necessary installation tools.
FAST-Connector
FAST-Connector Assembly Tools
Mechanical Splice
1 2 3 4 5
7 8 9 10 11
12 13 14 15
67
Latest information also available on the internet
URL : www.fujikura.co.jp
For Enquiry
Email :
[email protected]
OPTICAL COMPONENTS
OPTICAL FIBERS OPTICAL CABLES MONITORING / MANAGEMENT SYSTEM
Features
FuseConnect
TM
with factory pre-polished ferrule, utilizes fusion
splicer to terminate the connector in the eld. Similar to Fujikura
Field Installable connector series, eld-termination process
eliminates polishing, adhesives, and crimping in the eld.
Fusion splice addresses return loss concerns present in analog
optical networks. This advanced process yields true APC
performance of >65dB return loss in an SC/APC conguration.
The unique and innovative design of Fuse Connect eliminates the
complicated crimping operation. The simplied eld installation
minimizes the potential for operator error.
Application
Connectorization in :
RF-overlay FTTP network
Cable TV backbone network
Outside plant
MDU FTTP Cabling
Central ofce connector replacement.
Data center installation
Patch cord customization in the eld
FuseConnect
TM
Fusion-spliced, eld-terminated connector
UPC
APC
FuseConnect MPO Connector
Interior Structure
Ferrule Fusion Splice point
Optical fiber cable Steal rod Protection Sleeve Embedded fiber
Specication
Item Content
Applicable ber type 900um, 2mm, 3mm j3mm cordage (12c), Ribbon ber (12c)
Connector type SC or LC MPO (Male or Female)
Polishing UPC or APC n/a
Connection Loss (wrt master)
< 0.3dB (Singlemode) < 0.75 dB (Single mode)
< 0.3dB (Multimode) < 0.50 dB (Multimode)
Return Loss
> 65dB (SM ber APC polish) > 55 dB (Single mode)
> 55dB (SM ber UPC polish) n/a (Multimode)
> 30dB (MM UPC polish) -
Working temperature -40 C ~ 75 C
Ordering Information (SC, LC)
Type SC 900um ber SC 2mm code / SC 3mm code LC 900um ber LC 2mm code LC 3mm code
SM UPC Polish FuseConnect-SC-SF-SM-09 FuseConnect-SC-SF-SM-20/30 FuseConnect-LC-SF-SM-09 FuseConnect-LC-SF-SM-20 FuseConnect-LC-SF-SM-30
SM APC Polish FuseConnect-SC-SF-APC-09 FuseConnect-SC-SF-APC-20/30 FuseConnect-LC-SF-APC-09 FuseConnect-LC-SF-APC-20 FuseConnect-LC-SF-APC-30
MM(50/125) UPC Polish FuseConnect-SC-SF-GI5-09 FuseConnect-SC-SF-GI5-20/30 FuseConnect-LC-SF-GI5-09 FuseConnect-LC-SF-GI5-20 FuseConnect-LC-SF-GI5-30
MM(62.5/125) UPC Polish FuseConnect-SC-SF-GI6-09 FuseConnect-SC-SF-GI6-20/30 FuseConnect-LC-SF-GI6-09 FuseConnect-LC-SF-GI6-20 FuseConnect-LC-SF-GI6-30
MM10G UPC Polish FuseConnect-SC-SF-10G-09 FuseConnect-SC-SF-10G-20/30 FuseConnect-LC-SF-10G-09 FuseConnect-LC-SF-10G-20 FuseConnect-LC-SF-10G-30
FuseConnect SC Connector
FuseConnect LC Connector
Ordering Information (MPO)
Product Code
FuseConnect-MPO- X - Y - Z
Type of ber:
SM
GI5
GI6
MM10G
Type of cable:
Cordage
Ribbon
Type of connector:
Male
Female
68
Notes
FuseConnect
TM
Required tools
Fusion Splicer ; FSM-60S/60R, FSM-18S/18R, FSM-17S-FH/17R, FSM-11S/11R, FSM-50R
Yarn cutter, 900um ber stripper, Fiber Holder(FH-50-900 or FH-60-900), Fiber Cleaver,
Cable Clamp, Jacket stripper, Jacket split tool (FUSE-ST)
Jacket split tool (FUSE-ST)
Easy tool for splitting cord jacket with
longitudinal direction.
Accommodate to f2.0, f3.0mm cordage.
Assembly Flow (SC cordage)
1. Secure cord using cable clamp 4. Cleave the ber
7. Putting the fusion splice sleeve
3. Insert fusion splice sleeve
through 900um ber
6. Remove cord from the ber
holder and connector holder
2. Remove outer jacket
5. Set the ber holder and connector
holder on fusion splicer
8. Screw the boot unit into the back
of connector to x the yarn.
Trim away the excess yarn using
yarn cutter.
Assembly Flow (MPO)
1. Set the ber holder and connector
holder on fusion splicer.
2. Protect the ber splicing point
with mechanical clamp.
3. Incorporate housing parts into
connector body.
4. Completed
69
Latest information also available on the internet
URL : www.oneclickcleaner.com
For Enquiry
Email :
[email protected]
Features
Removes dust and oil adhering to the ferrule endface of ber optic connector with one push mechanical action.
Cleans the ferrule endface inside an adapter or connectors on jumpers by making full use of guide cap.
Refrains from transmission error or endface damage by dirty endface.
Comfortable and user friendly design with one click cleaning.
Complies with EU/95/2002/EC directive (RoHS).
Applications
Cleans the ferrule endface inside an adapter or connectors on jumpers and builds reliable networks for Datacom, FTTH, etc.
with faster installation of patchcords, pigtails and eld assembly connectors.
One-Click
TM
Cleaner
Covered by US Patent No. 8,087,118
Product Name
One-Click Ultra
Cleaner 2.5
One-Click
Cleaner SC
One-Click
Cleaner SC
Mini
One-Click
Cleaner MU/LC
One-Click Cleaner
MU/LC Mini
One-Click
Cleaner
D-LC
One-Click
Cleaner ODC
One-Click
Cleaner M20
Model Number
*3
M250-E-CLK-A SC-CLK-B SC-MINI-CLK-A MU/LC-CLK-B MU/LC-MINI-CLK-A DLC-CLK-A ODC-CLK-A M20-CLK-A
Applicable
Fiber Optic
Connector &
Adapter
*1
SC
FC
ST
MU
LC (only for Duplex)
f 1.25 mm
Multi-connector (ODC
)
f 2.0 mm
Multi-connector
(SMPTE 304M, etc.)
Applicable Polish Type PC, UPC, APC PC, UPC, APC PC, UPC
Type Enlarged Area Standard Mini Standard Mini Duplex Standard Standard
Nozzle Extendability
No. of Cleanings 500 times >500 times
Cleaning Method Dry (Cleaning the ferrule endface with cleaning cloth, with no chemical or solvent.)
Dimensions (mm)*
2
Extended Dimensions
22.5 W x 33.4 H
x 193 L
17.5 W x 17.5 W
x 165 L (200 L)
17.5 W x 30.5 H
x 104 L
17.5 W x 17.5 W
x 173 L (208 L)
17.5 W x 30.5 H
x 104 L
18.0 W x 30.0 H x
195 L
17.5 W x 17.5 H
x 178 L (213 L)
17.5 W x 17.5 H
x 164 L (199 L)
*1: Limited to the connector endface inside an adapter. *2: Guide cap dimensions and prongs are not included. *3: Last letter indicates model version. This is subjected to change.
Cable Tray
Cable Tray
Adapter
Equipment
Adapter
Telephone Table
Adapter
Rosette / Outlet
Wall
Termination Box
Adapter
Adapter
Wall
M250 SC
Cleaning Area
Ferrule
Optical ber
* The above is an example only.
Cleaning Example (UPC Polish) with Enlarged Area Type
M250 type can clean wider area of the connector endface.
Applications of Mini Type
Mini type is useful when the work space is limited and it is difcult for workers
to access to adapters.
OPTICAL COMPONENTS
OPTICAL FIBERS OPTICAL CABLES MONITORING / MANAGEMENT SYSTEM
70
Notes
One-Click
TM
Cleaner
How to use*
1
Cleaning Example (UPC Polish)
Enlarged image of endface before and after cleaning
Extension Features of Nozzle
(Standard type only)
Nozzle length can be extended if the adapter or connector is
not reachable.
Check the remainder of cleaning
cloth through window.
To clean the ferrule endface inside an adapter*
2
Guide Cap
Few
Nil
Many
* The above is an example only. Gently pull the nozzle by pressing the unlock button, and then extended.
Lid
Guide Cap
Cleaning of Oil Cleaning of Dust
Before cleaning After cleaning
Ferrule Optical ber
Before cleaning After cleaning
Ferrule Optical ber
PUSH
Points 1. Insert the cleaner tip into the adapter or connector on jumpers straight and vertically,
and then push it.
2. Push it slowly and gently.
3. Do not push it after hearing the click sound. Take it out gently and backward.
4. Do not squeeze it into the adapter or connector.
*1 Do not use the cleaner except for the endface cleaning.
*2 Limited to the connector endface inside an adapter.
1 Remove the guide cap.
2 Insert the nozzle tip into
the adapter. Push the
body to the adapter until
it clicks.
1 Open the lid of guide cap.
2 Insert the ferrule into a hole
on the guide cap and push
the body to the adapter
until it clicks.
MPO-CLK-C / MPX-CLK-A
One-Click
TM
MT-RJ
Multi-ber Connector Cleaner
Multi-ber Connector Cleaner
Product Name MPO Cleaner LIGHTRAY MPX Cleaner
Item / Model No MPO-CLK-C MPX-CLK-A
Applicable Connector MPO, MTP
LIGHTRAY MPX
Polishing method PC, APC PC, APC
No. of cleanings 500 times
* LIGHTRAY MPX is a trademark of The Whitaker Corporation MTP is a registered
trademark of US Conec Ltd.
Product Name One-Click cleaner MT-RJ
Item / Model No. MTRJ-CLK-A
Applicable Connector MTRJ
Polishing method PC
No. of Cleanings > 500 times
MPO-CLK-C MPX-CLK-A
MTRJ-CLK-A
71