10
DIAPHRAGM DESIGN
Large flat diaphragm permits precise valve control.
MATERIALS OF CONSTRUCTION
Pin and port materials offer maximum protection against
corrosion and erosion.
TABLE OF CONTENTS
Selection Procedure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
G . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22
EG . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23
BF . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24
S . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27
EBS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28
O . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29-30
H . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31
M . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32
Valve Specifications
V . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33
RC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
W . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34
ER . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
F & EF . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15-16
SELECTION PROCEDURE
The following procedure should be used when selecting a
Sporlan TEV:
1. Determine the liquid temperature of the refrigerant
entering the valve.
The TEV capacity tables on pages 4 to 8 are based on
a liquid temperature of 100F for R-22, R-134a, R401A,
R-402A, R-404A, R-407C, R-408A, R-409A, R-410A, and
R-507. For other liquid temperatures, apply the correction factor given in the tables for each refrigerant. For
example see Table B.
2. Determine pressure drop across valve.
The pressure drop correction factors are based on
standard liquid temperature and pressure drop. The
standard pressure drop is dependent on the evaporator
temperature. To determine the pressure drop, subtract
the saturated pressure equivalent to evaporator temperature from the condensing pressure. The condensing pressure used in this calculation should be the
minimum operating condensing pressure of the system.
From this value, subtract all other pressure losses to
obtain the net pressure drop across the valve. Use this
value to determine the pressure drop correction factor.
For example see Table C. Be sure to consider all of the
following possible sources of pressure drop:
1. Friction losses through refrigeration lines including
the evaporator and condenser.
2. Pressure drop across liquid line accessories such as a
solenoid valve and filter-drier.
3. Static pressure loss (gain) due to the vertical lift (drop)
of the liquid line.
4. Pressure drop across a refrigerant distributor if used.
Refer to Bulletin 20-10 for information on refrigerant distributors.
Application: medium temperature refrigeration
Design evaporator temperature . . . . . . . . . . . . . . . . . . . . 20F
Design condenser temperature . . . . . . . . . . . . . . . . . . . . . 95F
Refrigerant liquid temperature . . . . . . . . . . . . . . . . . . . . . 70F
Design system capacity . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 ton
Available pressure drop across TEV:
Condensing pressure (psig) . . . . . . . . . . . . . . . . . . . . . . . 182
Evaporating pressure (psig) . . . . . . . . . . . . . . . . . . . . . . . . 43
139
Liquid line and accessories loss (psi) . . . . . . . . . . . . . . . 4
Distributor and tubes loss (psi) Q . . . . . . . . . . . . . . . . . 35
100
Refrigerant liquid correction factor . . . . . . . . . . . . . . . . . 1.17
Pressure drop correction factor . . . . . . . . . . . . . . . . . . . . . 0.89
Use the following formula to calculate TEV capacity:
TEV Capacity = TEV rating x CF liquid temperature x CF pressure drop
EGVE-1 has valve capacity of: 1.09 x 1.17 x 0.89 = 1.14 Tons at
20F evaporating temperature, 100 psi pressure drop and 70 liquid
temperature.
NSION VALVE
THERMOSTATIC EXPAIGERANTS - TONS
FR
RE
for
IES
CIT
CAPA
ERC
HEAT PUMP and COMM
AIR CONDITIONING,
NT
VALVE
TYPES
F-EF-G -EG
F-EF-G -EG
F-EF-G -EG
G-EG
F-EF-G -EG
F-EF-G -EG
NOMINAL
CAPACIT Y
1/5
1/3
1/2
3/4
1
1-1/2
Liquid Temperature
The valve capacity should equal or
slightly exceed the tonnage rating
of the system. (For complete R-22
capacity tables, see pages 4 and 5.)
REFRIGERA
22
RMOSTATIC
RECOMMENDED THE
VZ, VZP40
VC, VCP100, VGA
ATURE F
EVAPORATOR TEMPER
-10 -20 -40
0
40 20
0.17 0.15 0.11
0.20 0.22 0.19
0.27 0.24 0.18
0.35 0.38 0.33
0.35 0.31 0.23 Design Evaporating
0.45 0.49 0.43
0.68 0.61 0.45 Temperature
0.75 0.82 0.71
0.86 0.77 0.57
5
0.9
9
1.0
0
1.0
1.22 1.09 0.81
2
1.5
1.74
1.60
Table A
Selection:
EGVE-1-C 3/8 x 1/2 x 1/4 ODF x 5
Q An externally equalized valve must be used on evaporators employing a refrigerant distributor due to the
pressure drop created by the distributor. In addition,
an externally equalized valve should always be used
with air conditioning thermostatic charges to reduce
the possibility of thermostatic charge migration.
LIQUID TEMPERA
TURE ENTERING TE
REFRIGERANT 0
V F
10 20 30
40 50 60
70 80
CORREC TION FACT
OR , CF LIQUID TEM
22
PERATURE
1.56 1.51 1.45
1.40 1.34 1.29
407C
1.23 1.17 1.12
1.69 1.62 1.55
1.49 1.42 1.35
1.28 1.21 1.14
Table B
TEV (psi)
PRESSURE DROP ACROSS
175 200
75 100 125 150
50
30
CF PRESSURE DROP
,
TOR
FAC
N
TIO
REC
COR
1.12 1.22 1.32 1.41
0.55 0.71 0.87 1.00
1.10 1.18 1.26
1.00
0.89
0.77
0.49 0.63
1.00 1.08 1.15
0.91
0.82
0.71
0.45 0.58
0.93 1.00 1.07
0.85
0.76
0.65
0.41 0.53
Table C
SELECTION PROCEDURE
7. Valve Nomenclature / Ordering Instructions
Combine the letters and numbers in the following manner to obtain the complete valve designation. Also include all connection sizes and the capillary tube length.
EXAMPLE
EG
Body
Type
E
specifies
external
equalizer.
Omission of
letter E
indicates
valve with
internal
equalizer.
e.g.
EGV-1-C
F = R-12 Yellow
E = R-13 Blue
V = R-22 Green
G = R-23 Blue
M = R-124 Blue
J = R-134a Blue
X = R-401A Pink
L = R-402A Sand
S = R-404A Orange
V = R-407A Green
N = R-407C Lt. Brown
S = R-408A Purple
F = R-409A Yellow
Z = R-410A Rose
V = R-422D Green
R = R-502 Purple
W = R-503 Blue
P = R-507 Teal
W = R-508B Blue
Nominal
Capacity
in Tons
3/8 ODF
SOLDER
Thermostatic
Charge
1/2 ODF
SOLDER
Inlet
Connection
Outlet
Connection
Size and
Style
Size and
Style
1/4 ODF
SOLDER
External
Equalizer
Connection
Capillary
Tubing
Length
Size and
Style
Inches or
Feet
Air Conditioning
Commercial
Refrigeration
50F to -10F
Low Temperature
Refrigeration
0F to -40F
Extreme Low Temperature
Refrigeration
-40F to -100F
REFRIGERANT
12,
409A
FCP60
FC
FZ
FZP
VCP100
ZCP180
VGA
ZGA
VC
VZ
VZP40
VX
407C
502
507
LC
LZ
LZP
404A,
408A
SCP115
SC
SZ
SZP
NCP100
NGA
NC
RCP115
RC
RZ
RZP
PC
PZ
PZP
ACTUAL
THERMOSTATIC
CHARGES
JCP60
VCP100
ZCP180
VGA
SCP115
ZGA
JC
VC
SC
PC
JZ
JZP
VZ
VZP40
SZ
SZP
VX
LX
SX
RX
PX
SX
134a
401A
402A
JCP60
JC
XCP60
XC
*APPLICATION FACTORS:
1. TheTypeZPchargeshaveessentiallythesamecharacteristicsastheTypeZchargewithoneexception:theyproduceapressurelimitMaximumOperatingPressure(MOP).ZPchargesarenotintendedasreplacements
for Z charges. Each should be selected for its own unique purpose.
2. All air conditioning and heat pump charges are intended for use with externally equalized valves.
3. Type L liquid charges are also available for most commonly used refrigerants in most element sizes.
4. The Type X charges are not to be used with EBS and O valves.
5. If in doubt as to which charge to use, review the section on thermostatic charges in Bulletin 10-9 or contact Sporlan Division of Parker, Washington, Missouri with complete system data.
6. For dual temperature applications, use the C charge.
7. The C charge may be used on applications down to -30F on R-22, R-404A and R-507.
FOR REFRIGERANTS: 22, 134a, 401A, 402A, 404A, 407C, 408A, 409A, 410A, 422D, 507
TEV capacity ratings for R-22, R-134a, R-401A, R-402A,
R-404A, R-407C, R-408A, R-409A, R-410A, R-422D, and
R-507 are based on vapor free 100F liquid refrigerant
entering the expansion valve, a maximum opening superheat of 7F, and a standard factory air test superheat setting. A discussion of the relationship between valve capacities and superheat settings can be found in Bulletin 10-9.
The ratings for evaporator temperatures 40F, 20F, -10F,
-40F in the capacity tables are in accordance with ANSI/
ARI Standard Number 750. TEVs are tested in accordance
with ANSI/ASHRAE 17.
REFRIGERANT
422DQ
407C
RECOMMENDED THERMOSTATIC CHARGE
NOMINAL
VALVE TYPES
CAPACITY
VC, VCP100, VGA
VZ, VZP40
VC, VCP100, VGA
VZ, VZP40
NC, NCP100, NGA
EVAPORATOR TEMPERATURE F
40 20
0
-10 -20 -40 40 20
0
-10 -20 -40 40 20
0
F-EF-G-EG
1/5
0.20 0.22 0.19 0.17 0.15 0.11 0.14 0.15 0.13 0.11 0.10 0.07 0.18 0.20 0.17
F-EF-G-EG
1/3
0.35 0.38 0.33 0.27 0.24 0.18 0.25 0.26 0.22 0.18 0.16 0.11 0.32 0.35 0.30
F-EF-G-EG
1/2
0.45 0.49 0.43 0.35 0.31 0.23 0.36 0.34 0.29 0.23 0.20 0.15 0.41 0.44 0.38
G-EG
3/4
0.75 0.82 0.71 0.68 0.61 0.45 0.54 0.57 0.48 0.45 0.40 0.28 0.69 0.74 0.64
F-EF-G-EG
1
1.00 1.09 0.95 0.86 0.77 0.57 0.71 0.76 0.64 0.57 0.50 0.36 0.92 0.99 0.85
F-EF-G-EG
1-1/2
1.60 1.74 1.52 1.22 1.09 0.81 1.14 1.21 1.02 0.81 0.71 0.51 1.47 1.58 1.36
F&EF(Ext)-G&EG(Ext)-S
2
2.00 2.18 1.91 1.96 1.75 1.31 1.43 1.51 1.28 1.30 1.14 0.82 1.84 1.97 1.70
F&EF (Int)-G&EG(Int)
2-1/2
2.50 2.72 2.38 2.20 1.97 1.47 1.78 1.89 1.60 1.45 1.28 0.92 2.30 2.46 2.12
F&EF (Ext)-G&EG (Ext)-S
3
3.20 3.49 3.05 2.33 2.09 1.56 2.28 2.42 2.05 1.54 1.36 0.97 2.94 3.16 2.71
S
4
4.50 4.90 4.29 3.43 3.07 2.29 3.21 3.40 2.88 2.27 1.99 1.43 4.14 4.44 3.81
S
5
5.20 5.67 4.96 4.04 3.62 2.70 3.71 3.93 3.33 2.67 2.35 1.69 4.78 5.13 4.41
S(Ext)
8
8.00 8.72 7.04 5.82 4.87 3.59 5.70 6.04 4.73 3.85 3.16 2.24 7.35 7.89 6.25
S(Ext)
10
10.0 10.9 8.80 7.27 6.08 4.48 7.13 7.56 5.91 4.81 3.95 2.80 9.19 9.86 7.82
H
5-1/2
5.60 5.98 5.34 4.59 3.39 2.73 3.99 4.15 3.59 3.03 2.20 1.71 5.15 5.41 4.75
H
7
7.00 7.48 6.67 5.14 3.79 3.06 4.99 5.18 4.48 3.40 2.46 1.91 6.43 6.76 5.93
H
11
10.5 11.2 10.0 7.00 5.17 4.17 7.49 7.77 6.73 4.63 3.36 2.61 9.65 10.1 8.90
H
16
15.2 16.2 14.5 10.0 7.38 5.96 10.8 11.3 9.74 6.61 4.79 3.72 14.0 14.7 12.9
H
20
22.2 23.7 21.2 16.3 12.0 9.71 15.8 16.4 14.2 10.8 7.81 6.07 20.4 21.5 18.8
M
21
21.5 23.4 22.5 18.4 16.3 13.2 15.3 16.2 15.1 12.2 10.6 8.27 19.8 21.2 20.0
M
26
26.5 28.9 27.8 26.0 23.0 18.7 18.9 20.0 18.7 17.2 15.0 11.7 24.4 26.1 24.7
M
34
34.0 37.1 35.6 30.6 27.1 22.0 24.2 25.7 24.0 20.2 17.6 13.8 31.3 33.5 31.7
M
42
42.0 45.8 44.0 39.6 32.7 25.2 29.9 31.7 29.6 26.2 21.3 15.8 38.6 41.4 39.2
BALANCED PORT THERMOSTATIC EXPANSION VALVES
BF-EBF-SBF
AAA
0.35 0.38 0.33 0.27 0.24 0.18 0.25 0.26 0.22 0.18 0.16 0.11 0.32 0.34 0.30
BF-EBF-SBF
AA
0.75 0.82 0.71 0.68 0.61 0.45 0.54 0.57 0.48 0.45 0.40 0.28 0.69 0.74 0.64
BF-EBF-SBF
A
1.60 1.74 1.52 1.22 1.09 0.81 1.14 1.21 1.02 0.81 0.71 0.51 1.47 1.58 1.36
BF-EBF-SBF
B
2.80 3.05 2.67 2.25 2.01 1.50 2.00 2.12 1.79 1.49 1.31 0.94 2.57 2.76 2.37
BF-EBF-SBF
C
5.20 5.67 4.96 4.04 3.62 2.70 3.71 3.93 3.33 2.67 2.35 1.69 4.78 5.13 4.41
EBS
8
8.51 8.81 7.30 6.15 5.15 3.79 6.06 6.10 4.90 4.06 3.34 2.37 7.81 7.96 6.48
EBS
11
11.5 11.9 9.86 8.32 6.96 5.13 8.20 8.25 6.63 5.50 4.52 3.21 10.6 10.8 8.77
EBS
15
15.5 16.3 12.2 11.1 8.88 6.85 11.0 11.3 8.19 7.33 5.77 4.28 14.2 14.7 10.8
EBS
20
22.3 22.8 16.9 15.4 12.4 8.66 15.9 15.8 11.4 10.2 8.02 5.42 20.5 20.6 15.0
O
15
15.0 15.5 13.0 9.20 8.15 6.14 10.7 10.8 8.75 6.08 5.29 3.84 13.8 14.1 11.6
O
20
22.2 23.0 19.3 16.3 12.0 9.71 15.8 15.9 13.0 10.8 7.81 6.07 20.4 20.8 17.1
O
30
30.5 31.6 26.5 19.4 17.1 14.4 21.7 21.9 17.8 12.8 11.1 8.97 28.0 28.6 23.6
O
40
40.3 43.5 32.0 29.5 26.1 21.8 28.7 30.1 21.5 19.5 17.0 13.6 37.0 39.3 28.5
O
55
55.0 59.3 43.7 39.4 29.9 24.3 39.2 41.1 29.4 26.0 19.4 15.2 50.6 53.7 38.9
O
70
73.0 78.8 58.0 51.5 34.0 26.4 52.0 54.6 39.0 34.0 22.1 16.5 67.1 71.3 51.6
V
52
52.0 56.1 54.0 52.2 37.0 29.5 37.1 38.9 36.3 34.5 24.0 18.4 47.8 50.8 48.0
V
70
73.0 78.8 75.8 71.6 50.7 40.4 52.0 54.6 50.9 47.3 32.9 25.3 67.1 71.3 67.4
V
100
100 108 104 92.2 65.3 52.1 71.3 74.8 69.8 60.9 42.4 32.6 91.9 97.6 92.3
W
135
143 154 148 132 93.5 74.5 102 107 99.7 87.3 60.7 46.6 131 140 132
W
180
180
128
165
VALVE TYPES
CARTRIDGE NO.
REPLACEABLE CARTRIDGE THERMOSTATIC EXPANSION VALVES
Q-EQ-SQ
0
1/3
0.35 0.38 0.33 0.27 0.24 0.18 0.25 0.26 0.22 0.18 0.16 0.11 0.32 0.35 0.30
Q-EQ-SQ
1
3/4
0.75 0.82 0.72 0.68 0.61 0.45 0.54 0.57 0.48 0.45 0.40 0.28 0.69 0.74 0.64
Q-EQ-SQ
2
1
1.00 1.09 0.95 0.86 0.77 0.57 0.71 0.76 0.64 0.57 0.50 0.36 0.92 0.99 0.85
Q-EQ-SQ
3
1-1/2
1.50 1.64 1.43 1.10 0.99 0.73 1.07 1.13 0.96 0.73 0.64 0.46 1.38 1.48 1.27
Q-EQ-SQ
4
2-1/2
2.50 2.73 2.38 2.20 1.97 1.47 1.78 1.89 1.60 1.45 1.28 0.92 2.30 2.46 2.12
Q-EQ-SQ
5
3-1/2
3.50 3.82 3.34 3.00 2.69 2.00 2.50 2.64 2.24 1.98 1.74 1.25 3.22 3.45 2.97
Q-EQ-SQ
6
5
4.80 5.24 4.58 3.65 3.27 2.44 3.42 3.63 3.07 2.41 2.12 1.52 4.41 4.73 4.07
Balanced port replaceable cartridges, AAA, AA, A, B and C, have the same capacities as the matching nominal capacity of the
BQ-EBQ-SBQ
standard balanced port valves above.
22
REFRIGERANT
20
EVAPORATOR TEMPERATURE
F
30
50
40
20 & 0
-10 & -20
-40
0.55
0.49
0.45
0.41
0.71
0.63
0.58
0.53
22
422D
407C
275
300
1.66
1.48
1.35
1.25
1.73
1.55
1.41
1.31
QR-422DcanbeusedinasystemwithR-22valves,buttheTEVcapacitywillbereduced.Pleaseverifyvalvecapacitywillhandlesystemload.
VALVE TYPES
NOMINAL
CAPACITY
ER, RC
ER, RC
ER, RC
ER, RC
ER, RC
ER, RC
ER, RC
ER
ER
ER
1
1-1/2
2
3
4
5
6
8
10
12
REFRIGERANT
22
422D
407C
22
40
1.0
1.8
2.3
3.2
4.2
5.0
6.0
8.0
10.4
12.1
20
1.1
1.9
2.5
3.5
4.6
5.5
6.5
8.7
11.4
13.2
REFRIGERANT
422DQ
RECOMMENDED THERMOSTATIC CHARGE
VCP100, VGAW
EVAPORATOR TEMPERATURE F
0
40
20
0
40
1.0
0.71
0.76
0.66
0.9
1.7
1.25
1.32
1.15
1.6
2.2
1.64
1.74
1.51
2.1
3.1
2.28
2.42
2.10
2.9
4.1
2.99
3.17
2.75
3.9
4.9
3.56
3.78
3.27
4.6
5.3
4.28
4.53
3.54
5.5
7.8
5.70
6.04
5.24
7.4
10.2
7.44
7.88
6.83
9.6
11.8
8.62
9.14
7.92
11.1
10
20
407C
20
1.0
1.7
2.3
3.2
4.1
4.9
5.9
7.9
10.3
11.9
0
0.9
1.5
2.0
2.8
3.6
4.3
4.7
6.9
9.0
10.5
Q R-422D can be used in a system with R-22 valves, but the TEV capacity will be reduced. Please verify valve capacity will handle system load.
W The RC valve for R-22 applications is only available with a VGA element.
410A
VALVE TYPES
NOMINAL
CAPACITY
ER, RC
ER, RC
ER, RC
ER, RC
ER, RC
ER, RC
ER, RC
ER
ER
ER
1
1-1/2
2
3
4
5
6
8
12-1/2
15
REFRIGERANT
410A
REFRIGERANT
410A
RECOMMENDED
THERMOSTATIC CHARGE
ZCP200, ZGAQ
EVAPORATOR TEMPERATURE F
40
20
0
1.2
1.3
1.2
2.1
2.3
2.0
2.7
3.0
2.7
3.8
4.1
3.7
5.0
5.4
4.9
5.9
6.5
5.8
7.1
7.8
6.3
9.5
10.4
9.3
12.3
13.5
12.1
14.3
15.7
14.0
Q The RC valve for R-410A applications is only available with a ZGA element.
NOMINAL
CAPACITY
VALVE TYPES
OZE-20
OZE-25
OZE-35
OZE-50
OZE-60
CARTRIDGE
VALVE
TYPES
TYPE
BQ, EBQ, SBQ
BQ, EBQ, SBQ
BQ, EBQ, SBQ
BQ, EBQ, SBQ
BQ, EBQ, SBQ
EVAPORATOR
TEMPERATURE
F
40
20 & 0
AAA
AA
A
B
C
20
25
35
50
60
1/3
3/4
1-3/4
3-1/2
6
REFRIGERANT
410A
RECOMMENDED
THERMOSTATIC CHARGE
ZCP200, ZGA
EVAPORATOR TEMPERATURE F
40
20
0
19.7
21.6
20.4
23.7
25.9
24.5
32.6
35.6
33.6
49.3
54.0
51.0
59.2
64.8
61.2
0.4
0.9
1.9
3.4
6.2
0.5
1.0
2.1
3.7
6.8
0.4
0.9
1.8
3.2
5.9
404A, 408A
408A
RECOMMENDED THERMOSTATIC CHARGE
SC, SCP115
SZ, SZP
SC, SCP115
SZ, SZP
EVAPORATOR TEMPERATURE F
40
20
0
-10
-20
-40
40
20
0
-10
-20
-40
F-EF-G-EG
1/8
0.15
0.16
0.15
0.15
0.13
0.11
0.20
0.21
0.20
0.22
0.19
0.16
F-EF-G-EG
1/6
0.23
0.24
0.23
0.24
0.21
0.17
0.31
0.33
0.32
0.34
0.30
0.25
F-EF-G-EG
1/4
0.29
0.31
0.29
0.31
0.27
0.22
0.39
0.42
0.41
0.43
0.38
0.32
F-EF-G-EG
1/2
0.56
0.59
0.56
0.59
0.51
0.42
0.75
0.81
0.77
0.83
0.72
0.61
F-EF-G-EG
1
1.02
1.10
1.04
1.10
0.94
0.79
1.37
1.50
1.44
1.54
1.34
1.14
F-EF-G-EG
1-1/2
1.53
1.61
1.39
1.47
1.26
1.05
2.05
2.19
1.92
2.06
1.79
1.53
F&EF(Ext)-G&EG(Ext)-S
2
2.04
2.14
1.84
1.96
1.68
1.40
2.74
2.92
2.54
2.74
2.38
2.04
S
3
2.86
3.00
2.52
2.45
2.10
1.75
3.83
4.08
3.48
3.43
2.98
2.54
S
4
4.08
4.28
3.60
3.42
2.94
2.45
5.48
5.83
4.97
4.80
4.17
3.56
S (Ext)
6
5.61
5.12
4.27
4.52
3.84
2.97
7.53
6.97
5.90
6.34
5.45
4.32
S (Ext)
7
7.14
6.51
5.44
5.76
4.90
3.79
9.58
8.87
7.50
8.08
6.94
5.51
H
3
2.85
2.72
2.32
2.45
2.08
1.65
3.83
3.71
3.20 3.434 2.95
2.41
H
4
4.08
3.89
3.15
3.42
2.91
2.32
5.48
5.30
4.34
4.80
4.13
3.37
H
6-1/2
6.63
6.33
5.12
5.32
4.52
3.60
8.90
8.61
7.06
7.46
6.41
5.24
H
9
9.69
9.25
7.48
6.11
5.19
4.13
13.0
12.6
10.3
8.57
7.36
6.01
H
12
13.3
12.7
10.2
9.79
8.31
6.62
17.8
17.2
14.1
13.7
11.8
9.60
M
15
16.1
17.1
13.1
13.8
12.4
10.0
21.6
23.3
18.0
19.3
17.5
14.5
M
20
21.0
22.3
16.4
17.3
15.5
12.5
28.2
30.3
22.7
24.2
22.0
18.2
M
25
26.2
27.8
20.5
20.3
18.2
14.7
35.2
37.8
28.3
28.4
25.8
21.4
M
30
31.6
33.5
24.7
23.5
21.1
17.0
42.4
45.7
34.1
32.9
29.9
24.7
BALANCED PORT THERMOSTATIC EXPANSION VALVES
BF-EBF-SBF
AAA
0.23
0.24
0.23
0.24
0.21
0.17
0.31
0.33
0.32
0.34
0.30
0.25
BF-EBF-SBF
AA
0.46
0.49
0.46
0.45
0.39
0.32
0.62
0.66
0.64
0.63
0.55
0.47
BF-EBF-SBF
A
1.02
1.10
1.04
1.10
0.94
0.79
1.37
1.50
1.44
1.54
1.34
1.14
BF-EBF-SBF
B
1.89
1.98
1.66
1.60
1.37
1.14
2.53
2.70
2.30
2.24
1.95
1.66
BF-EBF-SBF
C
2.86
3.00
2.50
2.45
2.10
1.75
3.83
4.08
3.48
3.43
2.98
2.54
EBS
6
5.71
5.63
4.61
4.15
3.28
2.97
7.67
7.66
6.40
5.82
4.66
4.32
EBS
7-1/2
7.75
7.64
6.26
5.28
4.18
3.78
10.4
10.4
8.68
7.41
5.93
5.49
EBS
10
9.54
9.63
7.25
6.72
5.56
4.64
12.8
13.2
10.0
9.42
7.88
6.74
EBS
13
13.6
14.0
10.2
9.54
8.00
6.15
18.3
19.0
14.2
13.4
11.4
8.94
O
9
9.69
9.24
7.24
6.11
5.31
4.43
13.0
12.6
10.1
8.57
7.53
6.44
O
12
13.3
12.6
9.91
9.74
8.46
7.06
17.8
17.2
13.8
13.6
12.0
10.3
O
21
21.4
20.4
14.3
11.7
10.1
8.46
28.8
27.8
19.8
16.4
14.4
12.3
O
30
30.8
32.3
23.0
17.5
15.2
12.7
41.4
44.0
32.0
24.5
21.5
18.4
O
35
35.7
37.4
26.7
19.0
16.5
13.8
47.9
51.0
37.0
26.6
23.4
20.0
O
45
45.9
48.1
34.3
21.9
19.0
15.9
61.6
65.6
47.6
30.7
26.9
23.1
V
38
38.7
39.4
33.6
33.2
30.5
24.1
52.0
53.7
46.6
46.6
43.2
35.1
V
50
52.0
52.9
45.1
47.4
43.5
34.4
69.8
72.1
62.6
66.5
61.7
50.0
V
70
71.4
72.6
62.7
66.4
60.9
48.1
95.8
99.0
87.0
93.1
86.4
70.0
VALVE TYPES
CARTRIDGE NO.
REPLACEABLE CARTRIDGE THERMOSTATIC EXPANSION VALVES
Q-EQ-SQ
0
1/6
0.20
0.22
0.20
0.20
0.17
0.14
0.27
0.30
0.28
0.28
0.24
0.21
Q-EQ-SQ
1
1/4
0.46
0.49
0.46
0.45
0.39
0.32
0.62
0.66
0.64
0.63
0.55
0.47
Q-EQ-SQ
2
1/2
0.66
0.72
0.67
0.59
0.51
0.42
0.89
0.98
0.94
0.83
0.72
0.61
Q-EQ-SQ
3
1
1.02
1.07
0.89
0.85
0.73
0.61
1.37
1.46
1.24
1.19
1.03
0.88
Q-EQ-SQ
4
1-1/2
1.63
1.71
1.44
1.47
1.26
1.05
2.19
2.33
1.99
2.06
1.79
1.53
Q-EQ-SQ
5
2
2.14
2.25
1.88
1.96
1.68
1.40
2.88
3.06
2.61
2.74
2.38
2.04
Q-EQ-SQ
6
3
2.86
3.00
2.51
2.45
2.11
1.75
3.83
4.08
3.48
3.43
2.98
2.54
Balancedportreplaceablecartridges,AAA,AA,A,BandC,havethesamecapacitiesasthematchingnominalcapacityofthestandardbalanced
BQ-EBQ-SBQ
port valves above.
NOMINAL
CAPACITY
VALVE TYPES
REFRIGERANT
404A
408A
404A
EVAPORATOR
TEMPERATURE
F
40
20 & 0
-10 & -20
-40
10
30
0.55
0.49
0.45
0.41
20
275
1.66
1.48
1.35
1.25
402A, 507
507
RECOMMENDED THERMOSTATIC CHARGE
LC
LZ, LZP
PC
PZ, PZP
EVAPORATOR TEMPERATURE F
40
20
0
-10
-20
-40
40
20
0
-10
-20
-40
F-EF-G-EG
1/8
0.15
0.16
0.15
0.16
0.13
0.11
0.14
0.15
0.14
0.15
0.13
0.11
F-EF-G-EG
1/6
0.23
0.24
0.23
0.24
0.21
0.18
0.22
0.24
0.22
0.24
0.20
0.17
F-EF-G-EG
1/4
0.29
0.31
0.29
0.31
0.27
0.23
0.29
0.30
0.29
0.30
0.26
0.22
F-EF-G-EG
1/2
0.56
0.59
0.56
0.59
0.51
0.43
0.55
0.58
0.54
0.58
0.50
0.41
F-EF-G-EG
1
1.02
1.10
1.04
1.11
0.95
0.80
1.00
1.08
1.01
1.08
0.93
0.77
F-EF-G-EG
1-1/2
1.52
1.61
1.39
1.48
1.27
1.07
1.50
1.57
1.36
1.44
1.24
1.03
F&EF(Ext)-G&EG(Ext)-S
2
2.03
2.14
1.84
1.97
1.70
1.42
2.00
2.09
1.79
1.92
1.65
1.38
S
3
2.85
3.00
2.52
2.47
2.12
1.78
2.79
2.93
2.45
2.40
2.06
1.72
S
4
4.07
4.28
3.60
3.45
2.97
2.49
3.99
4.19
3.50
3.36
2.89
2.41
S (Ext)
6
5.59
5.12
4.27
4.56
3.88
3.02
5.49
5.00
4.16
4.43
3.77
2.93
S (Ext)
7
7.12
6.51
5.44
5.81
4.95
3.85
6.99
6.36
5.30
5.65
4.80
3.73
H
3
2.85
2.72
2.32
2.46
2.10
1.68
2.79
2.66
2.26
2.40
2.04
1.63
H
4
4.07
3.89
3.15
3.45
2.94
2.36
3.99
3.81
3.07
3.36
2.86
2.28
H
6-1/2
6.61
6.33
5.12
5.36
4.57
3.66
6.49
6.18
4.98
5.22
4.44
3.54
H
9
9.66
9.25
7.48
6.16
5.25
4.20
9.48
9.04
7.28
5.99
5.09
4.07
H
12
13.2
12.7
10.2
9.86
8.40
6.73
13.0
12.4
10.0
9.59
8.16
6.52
M
15
16.1
17.1
13.1
13.9
12.5
10.2
15.8
16.7
12.7
13.5
12.1
9.83
M
20
20.9
22.3
16.4
17.4
15.7
12.7
20.6
21.8
16.0
16.9
15.2
12.3
M
25
26.1
27.8
20.5
20.4
18.4
14.9
25.6
27.2
20.0
19.9
17.9
14.5
M
30
31.5
33.5
24.7
23.6
21.3
17.3
30.9
32.8
24.1
23.0
20.7
16.7
BALANCED PORT THERMOSTATIC EXPANSION VALVES
BF-EBF-SBF
AAA
0.23
0.24
0.23
0.24
0.21
0.18
0.23
0.24
0.22
0.24
0.21
0.17
BF-EBF-SBF
AA
0.46
0.49
0.46
0.45
0.39
0.33
0.45
0.48
0.45
0.44
0.38
0.32
BF-EBF-SBF
A
1.02
1.10
1.04
1.11
0.95
0.80
1.00
1.08
1.01
1.08
0.93
0.77
BF-EBF-SBF
B
1.88
1.98
1.66
1.61
1.39
1.16
1.85
1.94
1.62
1.57
1.35
1.12
BF-EBF-SBF
C
2.85
3.00
2.52
2.47
2.12
1.78
2.79
2.93
2.45
2.40
2.06
1.72
EBS
6
5.69
5.63
4.63
4.18
3.32
3.01
5.59
5.50
4.52
4.06
3.22
2.92
EBS
7-1/2
7.73
7.64
6.29
5.32
4.23
3.84
7.59
7.47
6.13
5.18
4.10
3.72
EBS
10
9.51
9.64
7.28
6.77
5.62
4.71
9.35
9.43
7.10
6.59
5.46
4.57
EBS
13
13.6
14.0
10.2
9.61
8.08
6.25
13.4
13.7
9.99
9.36
7.85
6.06
O
9
9.66
9.25
7.28
6.16
5.37
4.50
9.48
9.04
7.09
5.99
5.21
4.36
O
12
13.2
12.7
9.96
9.81
8.55
7.17
13.0
12.4
9.71
9.54
8.30
6.95
O
21
21.3
20.4
14.4
11.8
10.2
8.60
21.0
20.0
14.0
11.4
9.95
8.32
O
30
30.7
32.3
23.1
17.6
15.3
12.9
30.1
31.6
22.5
17.1
14.9
12.5
O
35
35.6
37.5
26.8
19.1
16.7
14.0
34.9
36.6
26.1
18.6
16.2
13.5
O
45
45.7
48.2
34.5
22.0
19.2
16.1
44.9
47.1
33.6
21.4
18.6
15.6
V
38
38.6
39.5
33.8
33.5
30.8
24.5
37.9
38.6
32.9
32.6
29.9
23.7
V
50
51.8
52.9
45.3
47.8
44.0
34.9
50.9
51.8
44.2
46.5
42.7
33.8
V
70
71.2
72.7
63.0
66.9
61.5
48.9
69.9
71.0
61.4
65.1
59.8
47.4
VALVE TYPES
CARTRIDGE NO.
REPLACEABLE CARTRIDGE THERMOSTATIC EXPANSION VALVES
Q-EQ-SQ
0
1/6
0.20
0.22
0.20
0.20
0.17
0.15
0.20
0.21
0.20
0.20
0.17
0.14
Q-EQ-SQ
1
1/4
0.46
0.49
0.46
0.45
0.39
0.33
0.45
0.48
0.45
0.44
0.38
0.32
Q-EQ-SQ
2
1/2
0.66
0.72
0.67
0.59
0.51
0.43
0.65
0.70
0.66
0.58
0.50
0.42
Q-EQ-SQ
3
1
1.02
1.07
0.89
0.86
0.74
0.62
1.00
1.05
0.88
0.83
0.72
0.60
Q-EQ-SQ
4
1-1/2
1.63
1.71
1.44
1.48
1.27
1.07
1.60
1.67
1.41
1.44
1.24
1.03
Q-EQ-SQ
5
2
2.14
2.25
1.88
1.97
1.70
1.43
2.10
2.20
1.84
1.92
1.65
1.38
Q-EQ-SQ
6
3
2.86
3.00
2.51
2.47
2.13
1.77
2.79
2.93
2.46
2.40
2.07
1.72
Balancedportreplaceablecartridges,AAA,AA,A,BandC,havethesamecapacitiesasthematchingnominalcapacityofthestandardbalanced
BQ-EBQ-SBQ
port valves above.
NOMINAL
CAPACITY
VALVE TYPES
REFRIGERANT
402A
507
402A
EVAPORATOR
TEMPERATURE
F
40
20 & 0
-10 & -20
-40
10
30
0.55
0.49
0.45
0.41
20
275
1.66
1.48
1.35
1.25
REFRIGERANT
401A
409A
NOMINAL
RECOMMENDED THERMOSTATIC CHARGE
VALVE TYPES
CAPACITY
JC, JCP60
XC, XCP60
FC, FCP60
EVAPORATOR TEMPERATURE F
40
20
0
40
20
0
40
20
0
F-EF-G-EG
1/8
0.15
0.15
0.14
0.16
0.16
0.15
0.15
0.15
0.14
F-EF-G-EG
1/6
0.25
0.28
0.26
0.27
0.30
0.29
0.25
0.28
0.27
F-EF-G-EG
1/4
0.31
0.35
0.33
0.34
0.37
0.36
0.32
0.35
0.33
F-EF-G-EG
1/2
0.60
0.60
0.55
0.65
0.65
0.60
0.61
0.60
0.56
F-EF-G-EG
1
1.20
1.20
1.10
1.29
1.29
1.20
1.21
1.21
1.12
F-EF-G-EG
1-1/2
1.93
1.91
1.76
2.07
2.07
1.92
1.94
1.93
1.79
F&EF(Ext)-G&EG(Ext)-S
2
2.41
2.39
2.20
2.59
2.59
2.40
2.42
2.42
2.23
S
2-1/2
3.01
2.99
2.75
3.23
3.24
3.00
3.03
3.02
2.79
S
3
3.62
3.59
3.30
3.88
3.88
3.60
3.63
3.62
3.35
S (Ext)
5
6.03
4.98
4.17
6.47
5.39
4.56
6.05
5.03
4.24
S (Ext)
6
7.23
5.98
5.01
7.76
6.47
5.47
7.26
6.04
5.09
H
3
3.62
3.59
3.04
3.88
3.88
3.31
3.63
3.62
3.08
H
4
4.82
4.79
4.05
5.18
5.18
4.42
4.84
4.83
4.11
H
5
6.03
5.98
5.06
6.47
6.47
5.52
6.05
6.04
5.14
H
8
9.04
8.97
7.59
9.70
9.71
8.29
9.08
9.06
7.71
H
12
14.1
14.0
11.8
15.1
15.1
12.9
14.2
14.1
12.0
M
15
18.7
18.5
15.1
20.1
20.1
16.5
18.8
18.7
15.3
M
20
24.1
23.9
19.5
25.9
25.9
21.3
24.2
24.2
19.8
M
25
30.1
29.9
24.3
32.3
32.4
26.6
30.3
30.2
24.7
BALANCED PORT THERMOSTATIC EXPANSION VALVES
BF-EBF-SBF
AAA
0.25
0.28
0.26
0.27
0.30
0.29
0.25
0.28
0.27
BF-EBF-SBF
AA
0.54
0.54
0.50
0.58
0.58
0.54
0.55
0.54
0.50
BF-EBF-SBF
A
1.21
1.20
1.10
1.29
1.29
1.20
1.21
1.21
1.12
BF-EBF-SBF
B
2.05
2.03
1.87
2.20
2.20
2.04
2.06
2.05
1.90
BF-EBF-SBF
C
3.62
3.59
3.30
3.88
3.88
3.60
3.63
3.62
3.35
EBS
5
6.12
5.60
4.82
6.57
6.06
5.26
6.15
5.66
4.89
EBS
7
8.44
7.72
6.64
9.06
8.36
7.25
8.47
7.80
6.74
EBS
9
11.2
9.72
7.80
12.0
10.5
8.52
11.2
9.81
7.92
EBS
12
16.0
14.0
10.9
17.2
15.1
11.9
16.1
14.1
11.1
O
9
10.8
10.8
9.33
11.6
11.7
10.2
10.9
10.9
9.48
O
12
14.1
14.0
12.1
15.1
15.1
13.2
14.2
14.1
12.3
O
16
18.7
18.5
16.1
20.1
20.1
17.6
18.8
18.7
16.3
O
23
27.7
30.0
24.7
29.8
32.4
27.0
27.8
30.2
25.1
O
32
38.6
41.7
34.4
41.4
45.1
37.6
38.7
42.1
34.9
O
40
48.2
52.1
43.0
51.8
56.4
47.0
48.4
52.6
43.7
V
35
42.2
41.9
33.2
45.3
45.3
36.3
42.4
42.3
33.7
V
45
54.2
53.8
42.7
58.2
58.3
46.6
54.5
54.3
43.3
V
55
66.3
65.8
52.2
71.2
71.2
57.0
66.6
66.4
53.0
W
80
102
102
75.3
110
110
82.2
103
103
76.4
W
110
137
148
138
VALVE TYPES
CARTRIDGE NO.
REPLACEABLE CARTRIDGE THERMOSTATIC EXPANSION VALVES
Q-EQ-SQ
0
1/6
0.24
0.24
0.22
0.26
0.26
0.24
0.24
0.24
0.22
Q-EQ-SQ
1
1/4
0.54
0.54
0.50
0.58
0.58
0.54
0.55
0.54
0.50
Q-EQ-SQ
2
1/2
0.78
0.78
0.72
0.84
0.84
0.78
0.79
0.79
0.73
Q-EQ-SQ
3
1
1.21
1.20
1.10
1.29
1.29
1.20
1.21
1.21
1.12
Q-EQ-SQ
4
1-1/2
1.69
1.67
1.54
1.81
1.81
1.68
1.69
1.69
1.56
Q-EQ-SQ
5
2
2.41
2.39
2.20
2.59
2.59
2.40
2.42
2.42
2.23
Q-EQ-SQ
6
2-1/2
3.25
3.23
2.97
3.49
3.50
3.24
3.27
3.26
3.02
Balanced
port
replaceable
cartridges,
AAA,
AA,
A,
B
and
C,
have
the
same
capacities
as
the
matching
nominal
capacity
of
the
BQ-EBQ-SBQ
standard balanced port valves above.
134a
REFRIGERANT
134a
401A
409A
EVAPORATOR
TEMPERATURE
F
40
20 & 0
10
20
SPECS
R-22
R-134a
R-404A
& R-507
R-410A
CONNECTION
TYPES
Chatleff,
SAE Flare,
or
ODF Solder
ODF Solder
Smallbrassbody,externallyadjustablevalveavailableforR-22
andR-410Aairconditioningandheatpumpapplications.This
valvefeaturesabalancedportconstructionandisapproved
forbi-directionaloperation.SuitableforreplacingOEMtype
TEVswithoutinternalcheckvalveontheseapplications.A60
x 50 mesh inlet strainer is included with 3/8 inlet.
RC
Page
12
1
thru
6
1
thru
6
ER
Page
13
1
thru
12
1
thru
15
Page
15 - 16
1/5
thru
3
1/8
thru
2
1/8
thru
2
SAE Flare
Page
15 - 16
1/5
thru
3
1/8
thru
2
1/8
thru
2
ODF Solder
Q
1/3
thru
5
Q
1/6
thru
2-1/2
Q
1/6
thru
3
BQ
1/8
thru
5-1/2
BQ
1/8
thru
3
BQ
1/8
thru
3
BQ
1/4
thru
6
SAE Flare
EQ
1/3
thru
5
EQ
1/6
thru
2-1/2
EQ
1/6
thru
3
EQ
EBQ
1/8
thru
5-1/2
EBQ
1/8
thru
3
EBQ
1/8
thru
3
EBQ
1/4
thru
6
Extended
ODF Solder
TypeEQsameastheTypeQexceptitfeaturesextendedODF
connections.A100meshinsertstrainerisprovidedwiththe
valve. Type EBQ same as Type EQ with balanced port construction and is approved for bi-directional applications.
SQ
1/3
thru
5
SQ
1/6
thru
2-1/2
SQ
1/6
thru
3
SQ
SBQ
1/8
thru
5-1/2
SBQ
1/8
thru
3
SBQ
1/8
thru
3
SBQ
1/4
thru
6
Extended
ODF Solder
Type SQ same as the Type Q valve except it features ODF solderconnectionsandaforgedbrassinletfittingwitharemovable 100 mesh strainer screen which can be cleaned and/or
replacedwithoutremovingthevalvefromtheline.TypeSBQ
isthesameasTypeSQwithbalancedportconstructionandis
approved for bi-directional applications.
EF
Q/BQ
Page
17 - 21
EQ/EBQ
Page
17 - 21
SQ/SBQ
Page
17 - 21
R-22
R-134a
R-404A
& R-507
R-410A
CONNECTION
TYPES
Page
22
1/5
thru
3
1/8
thru
2
1/8
thru
2
SAE Flare
Page
23
1/5
thru
3
1/8
thru
2
1/8
thru
2
ODF Solder
SameastheTypeGvalveexceptitfeaturesODFsolderconnectionsandaforgedbrassinletfittingwitharemovable100
meshstrainerwhichcanbecleanedand/orreplacedwithout
removing the valve from the line.
Page
24
1/8
thru
5-1/2
1/8
thru
3
1/8
thru
3
SAE Flare
Same physical size as the Type F valve with SAE flare connectionsexceptitfeaturesabalancedportconstruction.Inlet connection has a removable 100 mesh strainer. Typical
applications:Smallcapacityrefrigerationthatoperatesover
widely varying operating conditions.
Page
25 - 26
1/8
thru
5-1/2
1/8
thru
3
1/8
thru
3
Extended
ODF Solder
SameastheTypeBFvalveexceptitfeaturesODFsolderconnectionsandaforgedbrassinletfittingwitharemovable100
meshstrainerwhichcanbecleanedand/orreplacedwithout
removing the valve from the line.
Page
25 - 26
1/8
thru
5-1/2
1/8
thru
3
1/8
thru
3
Extended
ODF Solder
Page
27
2
thru
10
2
thru
6
2
thru
7
ODF Solder
Brass bar body, externally adjustable valve. Inlet has a permanent12meshstrainer.Generalpurposevalveforairconditioning and refrigeration applications.
Page
28
8
thru
20
5
thru
12
6
thru
13
Extended
ODF Solder
SPECS
EG
BF
SBF
EBF
EBS
SPECS
CONNECTION
TYPES
ODF Solder
ODF Solder
or
FPT Flange
ODF Solder
or
FPT Flange
ODF Solder
or
FPT Flange
ODF Solder
Flange
R-22
R-134a
R-404A
& R-507
R-410A
15
thru
70
9
thru
40
9
thru
45
20
thru
60
O
Page
29 - 30
H
Page
31
5-1/2
thru
20
3
thru
12
3
thru
12
Page
32
21
thru
42
15
thru
25
15
thru
30
V
Page
33
52
thru
100
35
thru
55
Page
34
135
&
180
80
&
110
38
thru
70
TYPE RC
Type
RC
RCVE-1-GA
22 (V)
407C (N)
407A (V)
422D (V)
INLET
OUTLET
3/8 SAE
3/8 ODF
1/2 SAE
1/2 ODF
1/2 ODF
1/2 SAE
1/2 ODF
1/2 ODF
1/2 SAE
5/8 ODF
3/8 ODF
1/2 ODF
1/2 ODF
1/2 ODF
1/2 ODF
5/8 ODF
SHIPPING
WEIGHT
NET
WEIGHT
CONNECTIONS - Inches Q
SAE Flare/ R ODF Solder
RCVE-1-1/2-GA
1-1/2
RCVE-2-GA
1/4 SAE
1/4 ODF
RCVE-3-GA
RCVE-4-GA
2
3
43
VGA
RCVE-5-GA
RCVE-6-GA
RCZE-1-GA
RCZE-1-1/2-GA
410A (Z)
STANDARD
TUBING
LENGTH
EXTERNAL
EQUALIZER
W, E
THERMOSTATIC
CHARGES
AVAILABLE
VALVE TYPE
THERMOSTATIC
ELEMENT
SIZE NO.
REFRIGERANT
(Sporlan Code)
NOMINAL
CAPACITY
Tons of
Refrigeration
SPECIFICATIONS ELEMENT SIZE NO. 43 (R-22) AND NO. 45 (R-410A), KNIFE EDGE JOINT
30 in.
760 mm
1-1/2
RCZE-2-GA
RCZE-3-GA
1/4 ODF
RCZE-4-GA
RCZE-5-GA
RCZE-6-GA
45
ZGA
1.94
DIMENSIONS
Cap Tube 30
CONNECTIONS - Inches
VALVE
TYPE
RC
FITTING SIZE
3/8 SAE
1.92
1.63
1/2 SAE
1.89
1.92
1.63
3/8 ODF
1.92
1.45
0.31
1.90
1/2 ODF
1.98
1.45
0.40
1.90
5/8 ODF
1.53
0.50
1.90
1.89
1.71
RC Chatleff Fitting
C
3.66
C
2.30
1.81
REFRIGERANT
22
410A
0.75 OD x 2.00
Top View
30
Chatleff
Fitting Option E
TYPE ER
Type
ER
22 (V)
407C (N)
407A (V)
422D (V)
410A (Z)
ERVE-3
ERVE-4
ERVE-5
ERVE-6
ERVE-8
ERVE-10
10
ERVE-12
12
OUTLET
3/8
1/2
1 lb.
454 g
1-1/2 lbs.
680 g
1 lb.
454 g
1-1/2 lbs.
680 g
1/2 or 5/8
VGA
VCP100
60 in.
1.5 m
3/8 or 1/2
1/2
45-5
5/8
1
2
ERZE-3
ERZE-4
ERZE-5
ERZE-6
ERZE-8
ERZE-15
43
1-1/2
ERZE-2
ERZE-12-1/2
STANDARD
TUBING
LENGTH
1-1/2
2
ERZE-1-1/2
INLET
ERVE-2
ERZE-1
SHIPPING
WEIGHT
ERVE-1-1/2
CONNECTIONS -Inches
Q ODF Solder
NET
WEIGHT
ERVE-1
THERMOSTATIC
CHARGES
AVAILABLE
VALVE TYPE
THERMOSTATIC
ELEMENT
SIZE NO.
REFRIGERANT
(Sporlan Code)
NOMINAL
CAPACITY
Tons of
Refrigeration
SPECIFICATIONS ELEMENT SIZE NO. 43 (R-22), NO. 45 (R-410A), AND NO. 45-5, KNIFE EDGE JOINT
12-1/2
15
3/8
45
1/2 or 5/8
ZGA
ZCP180
60 in.
1.5 m
3/8 or 1/2
1/2
45-5
1/2
5/8
Q ODF Solder indicates a female connection on the valve of proper diameter to receive copper tubing of corresponding OD size. Thus 1/2 ODF will receive 1/2 OD tubing.
TYPE ER
1.94
49.3 mm
30
1.81
50.0 mm
Cap Tube 60
E
.253/.256
6.43/6.50 mm
Top View
F
3.53
89.7 mm
2.17
55.1 mm
Diameter
1.94
49.3 mm
DIMENSIONS - CONNECTIONS
REFRIGERANT
22
410A
NOMINAL
CAPACITY
1-1/2
2
3
4
5
3
4
5
6
4
5
6
8
B
BULB SIZES
FITTING SIZE
INLET OUTLET
3/8
1/2
5/8
1/2
7/8
6
8
7/8
5/8
1.83
46.5 mm
1-1/8
REFRIGERANT
22
410A
0.50 OD x 3.00
12.7 mm x 76.2 mm
0.75 OD x 2.00
19.1 mm x 50.8 mm
STANDARD
CHARGES
VCP100, ZCP180
GA
0.50
.627/.632
12.7
mm .502/.506 15.9/16.1 mm
12.8/12.9
mm
0.78
.877/.882
19.8
22.3/22.4
mm
mm
0.78
.877/.882
19.8
2.35 2.41 0.50 mm .627/.632 22.3/22.4mm
59.7 61.2 12.7 0.91 15.9/16.1 1.128/1.135
mm
mm mm mm
23.1
28.7/28.8
mm
mm
30
1.90
48.3 mm
0.31
7.9 mm
E
D
.253/.256
6.43/6.50 mm
3.79
96.3 mm
2.30
58.4 mm
F
C
Diameter
1.94
49.3 mm
1.83
46.5 mm
A
DIMENSIONS - CONNECTIONS
REFRIGERANT
NOMINAL
CAPACITY
22
10
12
410A
12-1/2
15
Cap Tube 60
FITTING SIZE
INLET OUTLET
7/8
5/8
1-1/8
.877/.882
0.78
22.3/22.4
19.8
mm
2.48 2.51 0.50 mm .627/.632
15.9/16.1
63.0 63.8 12.7
1.128/1.135
mm
mm mm mm 0.91
23.1
28.7/28.8
mm
mm
TYPE F & EF
Outlet Connections
3/8 SAE, 1/2 SAE, 3/8 ODF, 1/2 ODF
Mating Distributors (See Bulletin 20-10)
D260, D262, 1603, 1605, 1606, 1608, 1650(R)
Type
F
FV-1/5
FVE-1/5
EFV-1/5
EFVE-1/5
1/5
FV-1/3
FVE-1/3
EFV-1/3
EFVE-1/3
1/3
FV-1/2
FVE-1/2
EFV-1/2
EFVE-1/2
1/2
FV-1
FVE-1
EFV-1
EFVE-1
FV-1-1/2
FV-2-1/2
FJ-1/8
134a (J)
12 (F)
401A (X)
409A (F)
EFJE-1/8
1/8
EFJ-1/6
EFJE-1/6
1/6
EFJ-1/4
EFJE-1/4
1/4
1/2
FJ-1/2
FJE-1/2
EFJ-1/2
EFJE-1/2
FJ-1
FJE-1
EFJ-1
EFJE-1
FJE-1-1/2
EFJ-1-1/2
FJ-1-1/2
FJE-2
FSE-1/8
EFS-1/8
EFJE-1-1/2
EFJE-2
FS-1/6
FSE-1/6
EFS-1/6
EFSE-1/6
1/6
FSE-1/4
EFS-1/4
EFSE-1/4
1/4
1/2
FSE-1/2
EFS-1/2
EFSE-1/2
EFS-1
EFSE-1
FS-1-1/2
FSE-1-1/2
EFS-1-1/2
EFSE-1-1/2
FSE-2
FPE-1/8
EFP-1/8
EFSE-2
FP-1/6
FPE-1/6
EFP-1/6
EFPE-1/6
1/6
FP-1/4
FPE-1/4
EFP-1/4
EFPE-1/4
1/4
1/2
FPE-1/2
EFP-1/2
EFPE-1/2
FPE-1
EFP-1
EFPE-1
FPE-1-1/2
EFP-1-1/2
FP-1-1/2
FPE-2
EFPE-1-1/2
EFPE-2
3/8 E
1/2
1/4 or 3/8 Q
3/8 or 1/2
3/8 E
1/2
1/4 or 3/8 Q
3/8 or 1/2
3/8 E
1/2
1/4 or 3/8 Q
3/8 or 1/2
3/8 E
1/2
1 lb.
454 g
1-1/2 lbs.
680 g
2
1/8
FP-1/2
3/8 or 1/2
C
Z
ZP40
1-1/2
EFPE-1/8
FP-1
30 in.
760 mm
FS-1/4
FSE-1
1/4 or 3/8 Q
1-1/2
1/8
FS-1/2
OUTLET
EFSE-1/8
FS-1
STANDARD
TUBING
LENGTH
EFVE-3
INLET
C
Z
ZP40
2-1/2
FJE-1/6
402A (L)
EFJ-1/8
EFVE-2
FJE-1/4
FP-1/8
507 (P)
FJE-1/8
EFV-2-1/2
FJ-1/6
FS-1/8
502 (R)
408A (R)
1-1/2
FJ-1/4
404A (S)
FVE-2
SHIPPING
WEIGHT
407C (N)
407A (V)
422D (V)
CONNECTIONS - Inches
SAE Flare / W ODF Solder
NET
WEIGHT
22 (V)
TYPE EF
ODF Solder
THERMOSTATIC
CHARGES
AVAILABLE
REFRIGERANT
(Sporlan Code)
TYPE F
SAE Flare
NOMINAL
CAPACITY
Tons of
Refrigeration
1
1-1/2
C
Z
ZP40
Q The 3/8 SAE inlet fitting has a long taper on the flare surface. A 3/8 x 1/4 reducing flare nut will allow 1/4 OD tubing to be attached to this fitting.
W ODF Solder on Type EF valves indicates a female connection on the valve of proper diameter to receive copper tubing of corresponding OD size. Thus 1/2 ODF will receive 1/2 OD tubing.
E Nominal 1 ton and larger F valves for R-134a, R-404A and R-507 type refrigerants, and nominal 1-1/2 ton and larger for R-22 refrigerant require 3/8 SAE Flare or 3/8 ODF inlet, minimum.
TYPE F & EF
SAE FLARE
DIMENSIONS
1.94
A
1.05
1.27
1.61
1.80
C
1.34
0.98
0.50 OD x 3.00
1/4 SAE
Inlet
Strainer
P/N
3008-000
3/8 SAE
Inlet
Strainer
P/N
3.76 1538-000
2.02
External 1/4 SAE
Equalizer Fitting
60
C
B
A
1.54
Top View
ODF SOLDER
DIMENSIONS
1.94
A
1.69
1.69
1.35
1.35
C
0.31
0.31
0.40
REFRIGERANT
STANDARD
CHARGES
22
134a
404A
507
C
0.50 OD x 3.00
Z & ZP Series 0.50 OD x 3.00
0.50 OD x 3.00
3.76
2.43
2.02
3/8 ODF
Insert
Strainer
P/N 1524-000
30
1/4 ODF External
Equalizer
Connection
A
1.81
Top View
1/4 ODF
Insert
Strainer
P/N 1543-002
TYPE Q & BQ
SELECTIVE CHARGES
Sporlan selective thermostatic charges are
specifically designed for low temperature,
medium temperature, and air conditioning
applications. The elements are manufactured
with a large flat diaphragm to reduce diaphragm stresses and provide precise control.
And, because Q & BQ valve bodies and thermostatic elements are supplied as independent components, the installer is able to select
the best possible thermostatic charge for the
application.
INTERNAL PORT DESIGN
Refrigerant flow through the valve port opposes
the pin movement in all type Q and BQ valves.
This provides improved stability at light loads,
when the pin modulates to a position close
to the port. Additionally, charge migration, is
reduced or eliminated by the Q & BQ valve
design. By engineering the liquid flow to enter
through the top of the valve body, the liquid
refrigerant warms the thermostatic element
and minimizes the potential for charge migration.
For complete details of construction, see page 35.
TYPE
Conventional
Port
TYPE
Balanced Port
SELECTING COMPONENTS
BODY
Flare Connections
EQ
SAE
(Internally
Equalized)
SQ
ODF
(Internally
Equalized)
QE
SAE
(Externally
Equalized)
ODF
(Internally
Equalized)
EQE
EBQ
BQ
ODF
(Internally
Equalized)
SAE
(Internally
Equalized)
BQE
SAE
(Externally
Equalized)
U.S. Patent No. 5,238,219, Replaceable Strainer P/N 3427-000 U.S. Patent No. 5,232,015
SQE
ODF
(Externally
Equalized)
EBQE
ODF
(Externally
Equalized)
ODF
(Externally
Equalized)
SBQ
ODF
(Internally
Equalized)
SBQE
ODF
(Externally
Equalized)
TYPE Q & BQ
CARTRIDGE
Q CARTRIDGE SERVICE KIT PART NUMBER 184000
Top surface is color coded
to identify cartridge capacity.
0
2
QC-0 - Red
Qty. 3
SPORLAN
0
SIZE
QC-1 - Yellow
Qty. 5
QC-2 - Green
Qty. 5
QC-3 - Blue
Qty. 5
QC-4 - Pink
Qty. 3
Oil
Bottle
4 mm
Allen
Wrench
QC-5 - Black
Qty. 3
QC-6 - White
Qty. 3
Pushrods
Qty. 4
CAPACITIES
COLOR CODE
R-12
1/8
1/6
1/4
1/2
1
1-1/2
2
2-1/2
3
R-134a
R-401A
R-402A R-404A
1/8
1/6
1/8
1/6
1/8
1/6
1/4
1/4
1/2
1
R-410A
Q VALVE
CARTRIDGE
SIZE COLOR
CODE
R-502
R-507
1/8
1/6
1/8
1/6
1/8
1/6
Red
1/4
1/4
1/4
1/4
Yellow
1/2
1
1/2
1
1/2
1
1/2
1
1/2
1
2
3
Green
Blue
1-1/2
1-1/2
1-1/2
1-1/2
1-1/2
1-1/2
Pink
2
2-1/2
3
2
2-1/2
3
Black
White
NOT APPROVED
BQC-B - Pink
Qty. 1
BQC-B - Pink
Qty. 2
Oil
Bottle
L
POR A
BQC-A - Blue
Qty. 4
BQ Cartridge Tool
SPORLAN
AAA
PART NUMBER
BQC-AA - Yellow
Qty. 4
AAA
AA
AAA
BQC-AAA - Red
Qty. 2
BQ
BQC-C - White
Qty. 2
CAPACITIES
COLOR CODE
4444-000
BQ Cartridge Tool
CSK-1
184007
R-22,
R-422D
R-134a
BQ VALVE
CARTRIDGE
R-502
R-507
SIZE COLOR
CODE
1/8
1/8
1/8
1/8
1/8
1/8
1/4
1/8
1/8
AAA
thru 1/5 thru 1/3 thru 1/5 thru 1/5 thru 1/5 thru 1/5 thru 1/3 thru 1/5 thru 1/5
1/4
1/2
1/4
1/4
1/4
1/4
1/2
1/4
1/4
thru 1/3 thru 2/3 thru 1/3 thru 1/3 thru 1/3 thru 1/3 thru 3/4 thru 1/3 thru 1/3
1/2
3/4
1/2
thru 1 thru 1-1/2 thru 1
AA
Yellow
1/2
thru 1
1/2
1
1/2
thru 1 thru 1-3/4 thru 1
1/2
thru 1
Blue
1-1/4
1-3/4
1-1/4
1-1/4
1-1/4
thru 1-3/4 thru 3 thru 1-3/4 thru 1-3/4 thru 2
1-1/4
2
1-1/4
thru 2 thru 3-1/2 thru 2
1-1/4
thru 2
Pink
2-1/4
thru 3
2-1/4
thru 3
White
2 thru 3
3-1/4
2 thru 3
thru 5-1/2
1/2
thru 1
Red
2 thru 3
2-1/4
thru 3
4
thru 6
2-1/4
thru 3
TYPE Q & BQ
ELEMENT
SPORLAN REFRIGERANT CODE
KT-43-VC
ELEMENT
LABEL
COLOR CODE
F
V
J
X
L
S
V
N
R
F
Z
R
P
R-12
R-22, R-422D
R-134a
R-401A
R-402A
R-404A
R-407A
R-407C
R-408A
R-409A
R-410A
R-502
R-507
Yellow
Green
Blue
Pink
Sand
Orange
Green
Light Brown
Purple
Yellow
Pink
Purple
Teal
Bulb
5207
R -22
V E C O W A S H IN
GT
VA L
ON
AN
,
RL
M AD E IN
U .S.ofA. M O
CapillaryTube Length
(standard = 5 ft.)
PO
43
VC
Elem entLabel
KT
43
Element
Size
Number
Abbreviation
for Kit
Refrigerant
Code Q
Thermostatic
Charge
Q While many new refrigerants and refrigerant blends have a unique letter code, many use the same thermostatic element as the traditional refrigerant they replace.
Refer to the table below to select the correct thermostatic element.
12
22,
422D
134a
X
X
X
X
X
X
Air Conditioning
Commercial
Refrigeration
50F to -10F
Low Temperature
Refrigeration
0F to -40F
X
X
X
X
X
X
X
X
X
X
410A
502
507
X
X
X
X
X
X
THERMOSTATIC
ELEMENT
SYSTEM MOP
psig
KT-43-JCP60
KT-43-VCP100
KT-43-VGA
KT-43-SCP115
KT-45-ZGA
KT-45-ZCP180
KT-43-JC
KT-43-VC
KT-43-SC
KT-43-PC
KT-43-JZ
KT-43-JZP
KT-43-VZ
KT-43-VZP40
KT-43-SZ
KT-43-SZP
50
90
105
170
12
30
35
**APPLICATION FACTORS:
1. TheSporlanTypeZPthermostaticchargeshaveessentiallythesamecharacteristicsastheconventionalZcrosschargeswithoneexception:theyproduceapressurelimitorMOP.TheZPchargesarenotintendedasreplacements
for the Z charges - they should only be used where a definite pressure limit is required to prevent motor overloading.
2. All air conditioning and heat pump charges are intended for use with externally equalized valves.
3. For dual temperature applications, use the C charge.
4. The C charge may be used on applications down to -30F on R-22, R-404A and R-507.
5. R-410A elements for use with BQ, EBQ, and SBQ only.
QE
Valve Type
Q, EQ, SQ
Internally Equalized
QE, EQE, SQE
Externally Equalized
BQE
ELEMENT
QC
KT-43
Cartridge
Type
Cartridge
Size
Element Kit
KT-43
Refrigerant
Code
(See above)
Thermostatic
Charge
BODY
Valve Type
BQ, EBQ, SBQ
Internally Equalized
BQE, EBQE, SBQE
Externally Equalized
CARTRIDGE
CARTRIDGE
Cartridge
Size
5
Capillary
Tube
Length
ELEMENT
BQC AA KT-43
Cartridge
Type
Element Kit
KT-43
or
KT-45
(R-410A only)
Refrigerant
Code
(See above)
Thermostatic
Charge
5
Capillary
Tube
Length
TYPE Q & BQ
502 (R)
408A (R)
507 (P)
402A (L)
SQ-0
SQ-1
SQ-2
SQ-3
SQ-4
SQ-5
SQ-6
SQ-0
SQ-1
SQ-2
SQ-3
SQ-4
SQ-5
SQ-6
SQ-0
SQ-1
SQ-2
SQ-3
SQ-4
SQ-5
SQ-6
SQ-0
SQ-1
SQ-2
SQ-3
SQ-4
SQ-5
SQ-6
SQE-0
SQE-1
SQE-2
SQE-3
SQE-4
SQE-5
SQE-6
SQE-0
SQE-1
SQE-2
SQE-3
SQE-4
SQE-5
SQE-6
SQE-0
SQE-1
SQE-2
SQE-3
SQE-4
SQE-5
SQE-6
SQE-0
SQE-1
SQE-2
SQE-3
SQE-4
SQE-5
SQE-6
1/3
3/4
1
1-1/2
2-1/2
3-1/2
5
1/6
1/4
1/2
1
1-1/2
2
2-1/2
1/6
1/4
1/2
1
1-1/2
2
3
1/6
1/4
1/2
1
1-1/2
2
3
STANDARD
TUBING LENGTH
0
1
2
3
4
5
6
0
1
2
3
4
5
6
0
1
2
3
4
5
6
0
1
2
3
4
5
6
SHIPPING
WEIGHT
404A (S)
EQE-0
EQE-1
EQE-2
EQE-3
EQE-4
EQE-5
EQE-6
EQE-0
EQE-1
EQE-2
EQE-3
EQE-4
EQE-5
EQE-6
EQE-0
EQE-1
EQE-2
EQE-3
EQE-4
EQE-5
EQE-6
EQE-0
EQE-1
EQE-2
EQE-3
EQE-4
EQE-5
EQE-6
1 lb.
454 g
1-1/2
lbs.
680 g
SHIPPING
WEIGHT
12 (F)
401A (X)
409A (F)
EQ-0
EQ-1
EQ-2
EQ-3
EQ-4
EQ-5
EQ-6
EQ-0
EQ-1
EQ-2
EQ-3
EQ-4
EQ-5
EQ-6
EQ-0
EQ-1
EQ-2
EQ-3
EQ-4
EQ-5
EQ-6
EQ-0
EQ-1
EQ-2
EQ-3
EQ-4
EQ-5
EQ-6
NET
WEIGHT
134a (J)
QE-0
QE-1
QE-2
QE-3
QE-4
QE-5
QE-6
QE-0
QE-1
QE-2
QE-3
QE-4
QE-5
QE-6
QE-0
QE-1
QE-2
QE-3
QE-4
QE-5
QE-6
QE-0
QE-1
QE-2
QE-3
QE-4
QE-5
QE-6
CONNECTIONS
Inches
Blue figures are
standard and will
be furnished unless
otherwise specified.
NET
WEIGHT
407C (N)
407A (V)
422D (V)
Q-0
Q-1
Q-2
Q-3
Q-4
Q-5
Q-6
Q-0
Q-1
Q-2
Q-3
Q-4
Q-5
Q-6
Q-0
Q-1
Q-2
Q-3
Q-4
Q-5
Q-6
Q-0
Q-1
Q-2
Q-3
Q-4
Q-5
Q-6
Refer to Recommended
Thermostatic Elements on Page 19
22 (V)
NOMINAL
CAPACITY
Tons of
Refrigeration
REFRIGERANT
(Sporlan Code)
CARTRIDGE
THERMOSTATIC
CHARGES
AVAILABLE
1 lb.
454 g
1-1/2
lbs.
680 g
INLET x OUTLET
Q & QE Only
1/4 x 3/8 SAE
90 Angle Inlet
or
1/4 x 1/2 SAE
90 Angle Inlet
or
3/8 x 1/2 SAE
90 Angle Inlet
EQ Only
3/8 x 1/2 ODF
Straight Thru
5 ft.
1.5 m
EQE Only
3/8 x 1/2 ODF
Straight Thru
or
3/8 x 5/8 ODF
Straight Thru
or
1/2 x 5/8 ODF
Straight Thru
or
1/2 x 7/8 ODF
Straight Thru
SQ & SQE Only
3/8 x 1/2 ODF
90 Angle Inlet
22 (V)
407C (N)
407A (V)
422D (V)
134a (J)
12 (F)
401A (X)
409A (F)
404A (S)
502 (R)
408A (R)
410A (Z)
507 (P)
402A (L)
BQ-AAA
BQ-AA
BQ-A
BQ-B
BQ-C
BQ-AAA
BQ-AA
BQ-A
BQ-B
BQ-C
BQ-AAA
BQ-AA
BQ-A
BQ-B
BQ-C
BQ-AAA
BQ-AA
BQ-A
BQ-B
BQ-C
BQ-AAA
BQ-AA
BQ-A
BQ-B
BQ-C
BQE-AAA
BQE-AA
BQE-A
BQE-B
BQE-C
BQE-AAA
BQE-AA
BQE-A
BQE-B
BQE-C
BQE-AAA
BQE-AA
BQE-A
BQE-B
BQE-C
BQE-AAA
BQE-AA
BQE-A
BQE-B
BQE-C
BQE-AAA
BQE-AA
BQE-A
BQE-B
BQE-C
EBQ-AAA
EBQ-AA
EBQ-A
EBQ-B
EBQ-C
EBQ-AAA
EBQ-AA
EBQ-A
EBQ-B
EBQ-C
EBQ-AAA
EBQ-AA
EBQ-A
EBQ-B
EBQ-C
EBQ-AAA
EBQ-AA
EBQ-A
EBQ-B
EBQ-C
EBQ-AAA
EBQ-AA
EBQ-A
EBQ-B
EBQ-C
EBQE-AAA
EBQE-AA
EBQE-A
EBQE-B
EBQE-C
EBQE-AAA
EBQE-AA
EBQE-A
EBQE-B
EBQE-C
EBQE-AAA
EBQE-AA
EBQE-A
EBQE-B
EBQE-C
EBQE-AAA
EBQE-AA
EBQE-A
EBQE-B
EBQE-C
EBQE-AAA
EBQE-AA
EBQE-A
EBQE-B
EBQE-C
SBQ-AAA
SBQ-AA
SBQ-A
SBQ-B
SBQ-C
SBQ-AAA
SBQ-AA
SBQ-A
SBQ-B
SBQ-C
SBQ-AAA
SBQ-AA
SBQ-A
SBQ-B
SBQ-C
SBQ-AAA
SBQ-AA
SBQ-A
SBQ-B
SBQ-C
SBQ-AAA
SBQ-AA
SBQ-A
SBQ-B
SBQ-C
SBQE-AAA
SBQE-AA
SBQE-A
SBQE-B
SBQE-C
SBQE-AAA
SBQE-AA
SBQE-A
SBQE-B
SBQE-C
SBQE-AAA
SBQE-AA
SBQE-A
SBQE-B
SBQE-C
SBQE-AAA
SBQE-AA
SBQE-A
SBQE-B
SBQE-C
SBQE-AAA
SBQE-AA
SBQE-A
SBQE-B
SBQE-C
AAA
1/8 thru 1/3
AA
1/2 thru 2/3
A
3/4 thru 1-1/2
B
1-3/4 thru 3
C 3-1/4 thru 5-1/2
AAA
1/8 thru 1/5
AA
1/4 thru 1/3
A
1/2 thru 1
B 1-1/4 thru 1-3/4
C
2 thru 3
AAA
1/8 thru 1/5
AA
1/4 thru 1/3
A
1/2 thru 1
B
1-1/4 thru 2
C
2-1/4 thru 3
AAA
1/4 thru 1/3
AA
1/2 thru 3/4
A
1 thru 1-3/4
B
2 thru 3-1/12
C
4 thru 6
AAA
1/8 thru 1/5
AA
1/4 thru 1/3
A
1/2 thru 1
B
1-1/4 thru 2
C
2-1/4 thru 3
STANDARD
TUBING LENGTH
THERMOSTATIC
CHARGES
AVAILABLE
Refer to Recommended
Thermostatic Elements on Page 19
REFRIGERANT
(Sporlan Code)
CARTRIDGE
NOMINAL
CAPACITY
Tons of
Refrigeration
BQ SPECIFICATIONS ELEMENT SIZE NO. 43 (R-22) and N0. 45 (R-410A), KNIFE EDGE JOINT
CONNECTIONS
Inches
Blue figures are
standard and will
be furnished unless
otherwise specified.
INLET x OUTLET
BQ & BQE
1/4 x 3/8 SAE
90 Angle Inlet
or
1/4 x 1/2 SAE
90 Angle Inlet
or
3/8 x 1/2 SAE E
90 Angle Inlet
EBQ Only
3/8 x 1/2 ODF R
Straight Thru
5 ft.
1.5 m
EBQE Only
3/8 x 1/2 ODF R
Straight Thru
or
3/8 x 1/2 ODF R
90 Angle Inlet
or
1/2 x 5/8 ODF R
Straight Thru
or
1/2 x 7/8 ODF R
Straight Thru
SBQ & SBQE Only
3/8 x 1/2 ODF R
90 Angle Inlet
Q Valves listed in the column are NOT AVAILABLE with MOP type air conditioning charges.
W Standard External Equalizer 1/4 SAE (Q and BQ Body), 1/4 ODF (SQ, SBQ, EQ and EBQ Body).
E The 3/8 SAE inlet fitting has a long taper on the flare surface. A 3/8 x 1/4 reducing flare nut will allow 1/4 OD tubing to be attached to this fitting.
R ODF Solder indicates a female connection on the valve of proper diameter to receive copper tubing of corresponding OD size. Thus 1/2 ODF will receive 1/2 OD tubing.
TYPE Q & BQ
TYPE QE
TYPE BQE
FITTING SIZE
1/4 SAE, 90 Angle
3/8 SAE, 90 Angle
3/8 SAE
1/2 SAE
1/4 SAE
Inlet
Strainer
P/N 3008-000
2.43 3/8 SAE
Inlet
Strainer
P/N 1538-000
1.94
1.94
3.93
Top View
2.02
1.19
1.44
1.35 1.08
1.61
1.80
1/4 SAE
Inlet
Strainer
P/N 3008-000
2.53 3/8 SAE
Inlet
Strainer
P/N 1538-000
3.93
60
C
A
1.54
TYPE EQE
2.02
C
A
TYPE EBQE
1.94
1.94
C
3.93
3.93
3/8 ODF
Insert Strainer
P/N 877-003
1/2 ODF
Insert Strainer
P/N 877-004
2.43
2.53
2.02
3/8 ODF
Insert Strainer
P/N 877-003
1/2 ODF
Insert Strainer
P/N 877-004
2.02
FITTING SIZE
3/8
1/2
5/8
7/8
Top View
B
60
2.50 0.31
2.42 2.48 0.40
2.48 0.50
2.39 0.78
TYPE SQE
1.87
TYPE SBQE
1.94
1.94
Removable
Strainer
P/N
3427-000
Top View
Removable
Strainer
P/N 3427-000
60
.40
.40
1.87
3.93
2.43
3.93
2.53
2.02
.31
.84
.74
1.39
2.02
.31
2.48
1.39
22
134a
REFRIGERANT
404A
410A
507
C
0.50 OD x 3.00
0.50 OD x 3.00
Z & ZP Series 0.50 OD x 3.00
0.50 OD x 3.00
0.50 OD x 3.00
CP Series
0.50 OD x 3.00
GA
0.75 OD x 2.00
0.75 OD x 2.00
2.48
TYPE G
Outlet Connections
1/2 SAE
Mating Distributors (See Bulletin 20-10)
1603, 1605, 1606, 1608, 1650(R)
For complete details of construction, see page 35.
Type
G
22 (V)
407C (N)
407A (V)
422D (V)
134a (J)
12 (F)
401A (X)
409A (F)
404A (S)
502 (R)
408A (R)
507 (P)
402A (L)
GVE-1/5
GVE-1/3
GVE-1/2
GVE-3/4
GVE-1
GVE-1-1/2
GVE-2
GVE-3
GJE-1/8
GJE-1/6
GJE-1/4
GJE-1/2
GJE-1
GJE-1-1/2
GJE-2
GSE-1/8
GSE-1/6
GSE-1/4
GSE-1/2
GSE-1
GSE-1-1/2
GSE-2
GPE-1/8
GPE-1/6
GPE-1/4
GPE-1/2
GPE-1
GPE-1-1/2
GPE-2
1/5
1/3
1/2
3/4
1
1-1/2
2
2-1/2
3
1/8
1/6
1/4
1/2
1
1-1/2
2
1/8
1/6
1/4
1/2
1
1-1/2
2
1/8
1/6
1/4
1/2
1
1-1/2
2
INLET
OUTLET
1/4 or 3/8 W
1/4 or 3/8 W
3/8 W
1/4 or 3/8 W
1/4 or 3/8 W
5 ft.
1.5 m
3/8 W
1/4 or 3/8 W
1/4 or 3/8 W
3/8 W
1/4 or 3/8 W
1/4 or 3/8 W
3/8 W
2.31
.25
Removable
Strainer
P/N 1538-000
1.25
Top View
1.56
with external
equalizer 1.68
1.44
DIMENSIONS
0.50 OD x 3.50
X
0.75 OD x 4.00
0.75 OD x 4.00
CP Series
0.50 OD x 3.50
VGA
0.75 OD x 2.00
2 lbs.
3 lbs.
0.90 kg 1.36 kg
1/2
Q Valves listed in this column NOT AVAILABLE with MOP Type air conditioning charges.
W The 3/8 SAE inlet fitting has a long taper on the flare surface. A 3/8 x 1/4 reducing flare nut will allow 1/4
OD tubing to be attached to this fitting.
SHIPPING
WEIGHT
GV-1/5
GV-1/3
GV-1/2
GV-3/4
GV-1
GV-1-1/2
GV-2-1/2
GJ-1/8
GJ-1/6
GJ-1/4
GJ-1/2
GJ-1
GJ-1-1/2
GS-1/8
GS-1/6
GS-1/4
GS-1/2
GS-1
GS-1-1/2
GP-1/8
GP-1/6
GP-1/4
GP-1/2
GP-1
GP-1-1/2
CONNECTIONS - Inches
SAE Flare
NET
WEIGHT
External
Equalizer
1/4 SAE
Flare
STANDARD
TUBING
LENGTH
Internal
Equalizer
Q
Refer to Recommended
Thermostatic Charges on page 3
REFRIGERANT
(Sporlan Code)
NOMINAL
CAPACITY
Tons of
Refrigeration
VALVE TYPE
THERMOSTATIC
CHARGES
AVAILABLE
0.56
Diameter 3.06
of Type X
Charge
Diaphragm
Case is 3.62
1/4 SAE
Inlet
Strainer
P/N 772-000
1.31
1.88
TYPE EG
Type
EG
Replaceable Strainer
U.S. Patent No. 5,232,015
THERMOSTATIC
CHARGES
AVAILABLE
STANDARD
TUBING
LENGTH
EGV-1/5
EGV-1/3
EGV-1/2
EGV-3/4
EGV-1
EGV-1-1/2
EGV-2-1/2
EGJ-1/8
EGJ-1/6
EGJ-1/4
EGJ-1/2
EGJ-1
EGJ-1-1/2
EGS-1/8
EGS-1/6
EGS-1/4
EGS-1/2
EGS-1
EGS-1-1/2
EGP-1/8
EGP-1/6
EGP-1/4
EGP-1/2
EGP-1
EGP-1-1/2
EGVE-1/5
EGVE-1/3
EGVE-1/2
EGVE-3/4
EGVE-1
EGVE-1-1/2
EGVE-2
EGVE-3
EGJE-1/8
EGJE-1/6
EGJE-1/4
EGJE-1/2
EGJE-1
EGJE-1-1/2
EGJE-2
EGSE-1/8
EGSE-1/6
EGSE-1/4
EGSE-1/2
EGSE-1
EGSE-1-1/2
EGSE-2
EGPE-1/8
EGPE-1/6
EGPE-1/4
EGPE-1/2
EGPE-1
EGPE-1-1/2
EGPE-2
1/5
1/3
1/2
3/4
1
1-1/2
2
2-1/2
3
1/8
1/6
1/4
1/2
1
1-1/2
2
1/8
1/6
1/4
1/2
1
1-1/2
2
1/8
1/6
1/4
1/2
1
1-1/2
2
Refer to Recommended
Thermostatic Charges on page 3
REFRIGERANT
(Sporlan Code)
22 (V)
407C (N)
407A (V)
422D (V)
134a (J)
12 (F)
401A (X)
409A (F)
5 ft.
1.5 m
404A (S)
502 (R)
408A (R)
507 (P)
402A (L)
CONNECTIONS - Inches
W ODF Solder
INLET
OUTLET
3/8
1/2
Q Valves listed in this column NOT AVAILABLE with MOP Type air conditioning charges.
W ODF Solder indicates a female connection on the valve of proper diameter to receive copper tubing of corresponding OD size. Thus 1/2 ODF will receive 1/2 OD tubing.
DIMENSIONS
.25
1.33
SHIPPING
WEIGHT
External
Equalizer
1/4 ODF
Solder
VALVE TYPE
NET
WEIGHT
Internal
Equalizer
Q
NOMINAL
CAPACITY
Tons of
Refrigeration
2 lbs.
3 lbs.
0.90 kg 1.36 kg
2.31
*Removable
Strainer
P/N 3427-000
1.68
Top View
0.50 OD x 3.50
X
0.75 OD x 4.00
0.75 OD x 4.00
CP Series
0.50 OD x 3.50
VGA
0.75 OD x 2.00
1.80
Diameter 3.06
of Type X
Charge
Diaphragm
Case is 3.62
1.31
2.30
* Type EG valves manufactured prior to June 1994 use a smaller inlet strainer, P/N 1935-000, which has a 1/2 brass hex head. Current Type EG valves use inlet strainer P/N 3427-000 which has a 5/8 brass hex head.These
strainers are not interchangeable. The 3427-000 is available as a replacement part. The 1935-000 is no longer available.
TYPE BF
Outlet Connections
1/2 SAE
Mating Distributors (See Bulletin 20-10)
1603, 1605, 1606, 1608, 1650(R)
For complete details of construction, see page 35.
Type
BF
134a (J)
12 (F)
401A (X)
409A (F)
404A (S)
502 (R)
408A (R)
507 (P)
402A (L)
BFV-AAA
BFVE-AAA
BFV-AA
BFVE-AA
BFV-A
BFVE-A
AAA
AA
BFV-B
BFVE-B
1-3/4 thru 3
BFV-C
BFVE-C
BFJ-AAA
BFJE-AAA
AAA
BFJ-AA
BFJE-AA
AA
BFJ-A
BFJE-A
1/2 thru 1
BFJ-B
BFJE-B
BFJ-C
BFJE-C
2 thru 3
BFS-AAA
BFSE-AAA
AAA
BFS-AA
BFSE-AA
AA
BFS-A
BFSE-A
1/2 thru 1
BFS-B
BFSE-B
1-1/4 thru 2
BFS-C
BFSE-C
2-1/4 thru 3
BFP-AAA
BFPE-AAA
AAA
BFP-AA
BFPE-AA
AA
BFP-A
BFPE-A
1/2 thru 1
BFP-B
BFPE-B
1-1/4 thru 2
BFP-C
BFPE-C
2-1/4 thru 3
INLET
OUTLET
EXTERNAL
EQUALIZER
3/8
or
1/2
1/4
SHIPPING
WEIGHT
407C (N)
407A (V)
422D (V)
External
Equalizer
CONNECTIONS - Inches
SAE Flare
NET
WEIGHT
Internal
Equalizer
22 (V)
PORT
SIZE
SAE Flare
STANDARD
TUBING
LENGTH
REFRIGERANT
(Sporlan Code)
NOMINAL
CAPACITY
Tons of
Refrigeration
VALVE TYPE
THERMOSTATIC
CHARGES
AVAILABLE
1 lb.
454 g
1-1/2
lbs.
680 g
C
Z
ZP40
C
30 in.
760 mm
C
Z
ZP
3/8 Elbow
1/4 or 3/8 Elbow Q
1/4 or 3/8 Elbow Q
3/8 Elbow
1/4 or 3/8 Elbow Q
C
Z
ZP
Q The 3/8 SAE inlet fitting has a long taper on the flare surface. A 3/8 x 1/4 reducing flare nut will allow 1/4 OD tubing to be attached to this fitting.
DIMENSIONS
CONNECTIONS - Inches
FITTING SIZE
SAE Flare
1/4 Elbow
1.19
1.34
3/8 Elbow
1.35
0.98
3/8 SAE
1.61
1/2 SAE
1.80
60
1.54
3.76
Top View
1/4 SAE
Removable
Strainer
2.02
P/N 3008-000
3/8 SAE
Removable
Strainer
P/N 1538-000
1.94
22
C
Z & ZP Series 0.50 OD x 3.00
REFRIGERANT
134a
404A
0.50 OD x 3.00
507
0.50 OD x 3.00
suited for small capacity refrigeration applications which operate over widely varying
conditions.
Type
SBF
Outlet Connections
1/2 ODF, 5/8 ODF
Mating Distributors (See Bulletin 20-10)
D260, D262, 1620, 1622, 1651(R)
Type
EBF
Replaceable Strainer
U.S. Patent No. 5,232,015
TYPE EBF
22 (V)
407C (N)
407A (V)
422D (V)
134a (J)
12 (F)
401A (X)
409A (F)
404A (S)
502 (R)
408A (R)
507 (P)
402A (L)
SBFV-AAA SBFVE-AAA
EBFV-AAA EBFVE-AAA
SBFV-AA
SBFVE-AA
EBFV-AA
EBFVE-AA
SBFV-A
SBFVE-A
EBFV-A
EBFVE-A
SBFV-B
SBFVE-B
EBFV-B
EBFVE-B
1-3/4 thru 3
SBFV-C
SBFVE-C
EBFV-C
EBFVE-C
SBFJ-AAA
SBFJE-AAA
EBFJ-AAA
EBFJE-AAA
AAA
SBFJ-AA
SBFJE-AA
EBFJ-AA
EBFJE-AA
AA
SBFJ-A
SBFJE-A
EBFJ-A
EBFJE-A
1/2 thru 1
SBFJ-B
SBFJE-B
EBFJ-B
EBFJE-B
SBFJ-C
SBFJE-C
EBFJ-C
EBFJE-C
2 thru 3
SBFS-AAA
SBFSE-AAA
EBFS-AAA
EBFSE-AAA
AAA
SBFS-AA
SBFSE-AA
EBFS-AA
EBFSE-AA
AA
SBFS-A
SBFSE-A
EBFS-A
EBFSE-A
1/2 thur 1
SBFS-B
SBFSE-B
EBFS-B
EBFSE-B
1-1/4 thru 2
SBFS-C
SBFSE-C
EBFS-C
EBFSE-C
SBFP-AAA
SBFPE-AAA
EBFP-AAA
EBFPE-AAA
AAA
AA
2-1/4 thru 3
AAA
SBFP-AA
SBFPE-AA
EBFP-AA
EBFPE-AA
AA
SBFP-A
SBFPE-A
EBFP-A
EBFPE-A
1/2 thru 1
SBFP-B
SBFPE-B
EBFP-B
EBFPE-B
1-1/4 thru 2
SBFP-C
SBFPE-C
EBFP-C
EBFPE-C
2-1/4 thru 3
THERMOSTATIC
CHARGES
AVAILABLE
STANDARD
TUBING
LENGTH
TYPE SBF
NOMINAL
CAPACITY RANGE
Tons of
Refrigeration
CONNECTIONS - Inches
Q Extended ODF Solder
INLET OUTLET
EXTERNAL
EQUALIZER
NET
WEIGHT
SHIPPING
WEIGHT
C
Z
ZP40
C
30 in.
760 mm
C
Z
ZP
3/8
1/2
or
5/8
1/4
Pointed
Toward
1-1/2
Bottom Cap 1 lb.
lbs.
or
454 g
680 g
Parallel
to Outlet
Connection
C
Z
ZP
Q ODF Solder indicates a female connection on the valve of proper diameter to receive copper tubing of corresponding OD size. Thus 1/2 ODF will receive 1/2 OD tubing.
TYPE SBF
1/4 ODF
External
Equalizer
Connection
2.00
2.33
1.94
30
Removable
Strainer
P/N 3427-000
A
3.76
2.02
.31
Top View
.74
1.39
DIMENSIONS
2.50
CONNECTIONS - Inches
OUTLET
FITTING SIZE
1/2
5/8
A
0.40
0.50
REFRIGERANT
134a
404A
0.50 OD x 3.00
22
C
Z & ZP Series 0.50 OD x 3.00
507
0.50 OD x 3.00
TYPE EBF
1/4 ODF
External
Equalizer
Connection
2.00
2.33
1.94
30
.31
3.76
2.43
Top View
3/8 ODF
Insert
Strainer
P/N 877-003
2.50
DIMENSIONS
CONNECTIONS - Inches
OUTLET
FITTING SIZE
1/2
5/8
A
0.40
0.50
22
C
Z & ZP Series 0.50 OD x 3.00
REFRIGERANT
134a
404A
0.50 OD x 3.00
507
0.50 OD x 3.00
2.50
2.02
TYPE S
Outlet Connections
5/8 ODF, 7/8 ODF, 1-1/8 ODF
Mating Distributors (See Bulletin 20-10)
1112, 1113, 1115, 1116, 1620, 1622, 1651(R), 1653(R),
1655(R)
Type
S
22 (V)
407C (N)
407A (V)
422D (V)
134a (J)
12 (F)
401A (X)
409A (F)
404A (S)
502 (R)
408A (R)
507 (P)
402A (L)
SVE-2
SV-3
SVE-3
SV-4
SVE-4
SV-5
SVE-5
SVE-8
SVE-10
10
SJ-2
SJE-2
SJ-2-1/2
SJE-2-1/2
SJ-3
SJE-3
SJE-5
SJE-6
SS-2
SSE-2
SS-3
SSE-3
SS-4
SSE-4
SSE-6
SSE-7
SP-2
SPE-2
SP-3
SPE-3
SP-4
SPE-4
SPE-6
SPE-7
2-1/2
5 ft.
1.5 m
INLET
OUTLET
3/8 or 1/2
1/2
5/8
7/8 or 1-1/8
3/8 or 1/2
1/2
5/8
7/8 or 1-1/8
3/8 or 1/2
1/2
5/8
7/8 or 1-1/8
3/8 or 1/2
1/2
5/8
7/8 or 1-1/8
2 lbs.
3 lbs.
0.90 kg 1.36 kg
Q Valves listed in this column NOT AVAILABLE with MOP Type air conditioning charges.
W ODF Solder indicates a female connection on the valve of proper diameter to receive copper tubing of corresponding OD size. Thus 5/8 ODF will receive 5/8 OD tubing.
2.31
DIMENSIONS
30
CONNECTIONS - Inches
FITTING SIZE
3/8
1/2
5/8
7/8
1-1/8
1.34
1.29
1.50
1.36
1.57
2.13
2.19
0.31
0.40
0.50
0.78
0.91
1.40
1/4 ODF
External
Equalizer
Connection
1.66
2.13
C
Top View
C
0.50 OD x 3.50
X
0.75 OD x 4.00
0.75 OD x 4.00
CP Series
0.50 OD x 3.50
VGA
0.75 OD x 2.00
3.53
Diameter
of Type X
Charge
Diaphragm
Case is 3.62
SHIPPING
WEIGHT
SV-2
NET
WEIGHT
External
Equalizer
CONNECTIONS - Inches
W ODF Solder
STANDARD
TUBING
LENGTH
Internal
Equalizer
Q
Refer to Recommended
Thermostatic Charges on page 3
REFRIGERANT
(Sporlan Code)
NOMINAL
CAPACITY
Tons of
Refrigeration
VALVE TYPE
THERMOSTATIC
CHARGES
AVAILABLE
TYPE EBS
Outlet Connections
7/8 ODF, 1-1/8 ODF, 1-3/8 ODF
Mating Distributors (See Bulletin 20-10)
1112, 1113, 1115, 1116, 1117, 1126, 1128, 1653(R),
1655(R), 1657(R)
Type
EBS
407C (N)
407A (V)
422D (V)
134a (J)
12 (F)
401A (X)
409A (F)
404A (S)
502 (R)
408A (R)
507 (P)
EXTERNAL
EQUALIZER
OUTLET
1/2 or 5/8
7/8 or 1-1/8
11
EBSVE-15
15
5/8 or 7/8
EBSVE-20
20
7/8
1-1/8 or 1-3/8
EBSJE-5 W
EBSJE-7 W
EBSJE-9
EBSJE-12
12
EBSSE-6 W
EBSSE-7-1/2 W
7-1/2
EBSSE-10
10
EBSSE-13
13
EBSPE-6 W
5 ft.
1.5 m
1/2 or 5/8
7/8 or 1-1/8
5/8 or 7/8
7/8
1-1/8 or 1-3/8
1/2 or 5/8
7/8 or 1-1/8
5/8 or 7/8
7/8
1-1/8 or 1-3/8
1/2 or 5/8
7/8 or 1-1/8
7-1/2
EBSPE-10
10
5/8 or 7/8
EBSPE-13
13
7/8
1-1/8 or 1-3/8
1/4
Pointed
Toward
Bottom Cap
or
Parallel
to Outlet
Connection
SHIPPING
WEIGHT
INLET
NET
WEIGHT
EBSVE-11 W
EBSPE-7-1/2 W
402A (L)
CONNECTIONS - Inches E
Q Extended ODF Solder
EBSVE-8 W
*Refer to Recommended
Thermostatic Charges on page 3
22 (V)
External
Equalizer
STANDARD
TUBING
LENGTH
REFRIGERANT
(Sporlan Code)
THERMOSTATIC
CHARGES
AVAILABLE
VALVE TYPE
NOMINAL
CAPACITY
Tons of
Refrigeration
2 lbs. 3 lbs.
0.90 kg 1.36 kg
Q ODF Solder indicates a female connection on the valve of proper diameter to receive copper tubing of corresponding OD size. Thus 5/8 ODF will receive 5/8 OD tubing.
W Approved for bi-directional applications.
E Minimum quantities may apply to non-standard connections. Not all connection combinations are available.
* X charge not available.
1/4 ODF
External
Equalizer
Connection
DIMENSIONS
CONNECTIONS - Inches
FITTING
SIZE
1/2
5/8
7/8
1-1/8
1-3/8
2.49
2.46
2.46
2.53
2.53
3.04
0.40
0.50
0.78
0.91
0.97
30
2.31
1.81
C
C
Top View
3.41
2.82
0.50 OD x 3.50
CP Series
0.50 OD x 3.50
VGA
0.75 OD x 2.00
TYPE O
Sporlan Type O valve is a brass bar body, externally adjustable valve with ODF solder connections. The thermostatic element is replaceable,
and the inlet connection has a permanent 12
mesh strainer. This valve type features a balanced port construction, and it is designed for
both air conditioning and refrigeration applications. A synthetic seating surface provides
tight shut-off during system off periods.
Type
O
U.S. Patent
No. 3,742,722
22 (V)
407C (N)
407A (V)
422D (V)
134a (J)
12 (F)
401A (X)
409A (F)
404A (S)
502 (R)
408A (R)
410A (Z)
507 (P)
402A (L)
OVE-15 W
15
OVE-20 W
20
OVE-30 W
30
OVE-40
40
OVE-55
55
OVE-70
70
OJE-9
OJE-12
12
OJE-16
16
OJE-23
23
OJE-32
32
OJE-40
40
OSE-9
OSE-12
12
OSE-21
21
OSE-30
30
OSE-35
35
OSE-45
45
OZE-20 W
20
OZE-25 W
25
OZE-35 W
35
OZE-50
50
OZE-60
60
OPE-9
OPE-12
12
OPE-21
21
OPE-30
30
OPE-35
35
OPE-45
45
1-1/8
7/8
83
33
85
85-3
83
33
INLET
1-1/8
1-3/8 or 1-5/8
1-1/8
1-3/8
1-1/8
7/8
1-3/8 or 1-5/8
1-1/8
1-3/8
5 feet
1.5 m
1-1/8
1-3/8 or 1-5/8
2 lbs.
3 lbs.
0.90 kg 1.36 kg
4 lbs.
5 lbs.
1.82 kg 2.27 kg
2 lbs.
3 lbs.
0.90 kg 1.36 kg
4 lbs.
5 lbs.
1.82 kg 2.27 kg
2 lbs.
3 lbs.
0.90 kg 1.36 kg
4 lbs.
5 lbs.
1.82 kg 2.27 kg
7/8
1-1/8
2 lbs.
3 lbs.
0.90 kg 1.36 kg
1-1/8
1-3/8
4 lbs.
5 lbs.
1.82 kg 2.27 kg
7/8
1-1/8
1-3/8
1-1/8
1-3/8 or 1-5/8
Q ODF Solder indicates a female connection on the valve of proper diameter to receive copper tubing of corresponding OD size. Thus 5/8 ODF will receive 5/8 OD tubing.
W Optional bi-directional feature is available, please contact Sporlan Division of Parker for more information.
* X charge not available.
SHIPPING
WEIGHT
OUTLET
1-3/8
33
83
7/8
83
33
CONNECTIONS - Inches
Q ODF Solder
NET
WEIGHT
STANDARD
TUBING
LENGTH
THERMOSTATIC
CHARGES
AVAILABLE
External
Equalizer
*Refer to Recommended
Thermostatic Charges on page 3
REFRIGERANT
(Sporlan Code)
THERMOSTATIC
ELEMENT
SIZE NO.
VALVE TYPE
NOMINAL
CAPACITY
Tons of
Refrigeration
SPECIFICATIONS ELEMENT SIZE NO. 83, NO. 33, NO. 85 (R-410A), AND NO. 85-3 (R-410A), KNIFE EDGE JOINT
2 lbs.
3 lbs.
0.90 kg 1.36 kg
4 lbs.
5 lbs.
1.82 kg 2.27 kg
TYPE O
1.40
2.31
1.70
Top View
2.43
DIMENSIONS
CONNECTIONS - Inches
STRAIGHT THRU
ODF SOLDER
7/8
2.09
2.08
0.78
1-1/8
2.21
2.23
0.91
1-3/8
2.39
0.97
C
4.14
22
134a
0.50 OD X 3.50
C
Z & ZP Series 0.50 OD X 3.50
CP Series
GA
REFRIGERANT
404A
0.50 OD X 3.50
0.50 OD X 3.50
0.75 OD X 2.00
A
410A
507
0.50 OD X 3.50
0.50 OD X 3.50
0.75 OD X 2.00
2.31*
2.75
1.59
1.93
Top View
2.90
C
C
DIMENSIONS
CONNECTIONS - Inches
STRAIGHT THRU
ODF SOLDER
5.52
1-1/8
2.69
0.91
1-3/8
2.84
0.97
1-5/8
3.12
1.09
A
BULB SIZES - Inches
STANDARD
CHARGES
C
REFRIGERANT
22
134a
404A
0.75 OD x 4.00 0.50 OD x 5.00 0.75 OD x 4.00
0.75 OD x 4.00
0.75 OD x 4.00
0.75 OD x 4.00
410A
507
0.75 OD x 4.00
0.75 OD x 4.00
0.75 OD X 2.00
TYPE H
Outlet Connections
7/8 ODF, 1-1/8 ODF, H flange type
Mating Distributors (See Bulletin 20-10)
1109, 1110, 1112, 1113, 1115, 1116, 1124,
1192 (aluminum), 1653(R), 1655(R)
Type
H
HV-5-1/2
22 (V)
12 (F)
401A (X)
409A (F)
404A (S)
HVE-11
11
HVE-16
16
HVE-20
20
HJ-3
HJE-3
HJ-4
HJE-4
HJ-5
HJE-5
HJE-8
HJE-12
12
HS-3
HSE-3
HS-4
HSE-4
HSE-6-1/2
HSE-9
HSE-12
12
HP-3
HPE-3
HP-4
HPE-4
402A (L)
6-1/2
HPE-6-1/2
6-1/2
HPE-9
HPE-12
12
5 ft.
1.5 m
FLANGE
RING
SIZE
OD x ID
Inches
R
INLET
OUTLET
5/8 or 7/8
7/8 or 1-1/8
7/8
7/8 or 1-1/8
5/8 or 7/8
7/8 or 1-1/8
7/8
7/8 or 1-1/8
5/8 or 7/8
7/8 or 1-1/8
7/8
7/8 or 1-1/8
5/8 or 7/8
7/8 or 1-1/8
7/8
7/8 or 1-1/8
1.25 x 1.00
SHIPPING
WEIGHT
CONNECTIONS - Inches
E ODF Solder
NET
WEIGHT
5-1/2
HVE-7
502 (R)
408A (R)
507 (P)
HVE-5-1/2
407C (N)
407A (V)
422D (V)
134a (J)
External
Equalizer
W
STANDARD
TUBING
LENGTH
Internal
Equalizer
Q
Refer to Recommended
Thermostatic Charges on page 3
REFRIGERANT
(Sporlan Code)
NOMINAL
CAPACITY
Tons of
Refrigeration
VALVE TYPE
THERMOSTATIC
CHARGES
AVAILABLE
5 lbs.
6 lbs.
2.27 kg 2.72 kg
Q Valves listed in this column NOT AVAILABLE with MOP Type air conditioning charges.
W Standard External Equalizer Connection 1/4 SAE Flare, 1/4 ODF Solder connection available on request.
E ODF Solder indicates a female connection on the valve of proper diameter to receive copper tubing of corresponding OD size. Thus, 5/8 ODF will receive 5/8 OD tubing.
R Kit K-1178 with two brass bushings is available for two purposes: 1) To allow the current Type H valve to replace obsolete Types T and H with 1.125 x 0.75 flange rings by mating with the smaller flange ring bushings and/or
distributors. 2) To allow the Type H to use 1/2 FPT connections Part number 225-002 and 1/2 socket weld connections Part number 580-000. Order the appropriate 1/2 connections and one K-1178 per valve.
DIMENSIONS
2.75
CONNECTIONS - Inches
SOLDERING
BUSHING
1/2
2.00
0.88
5/8
2.00
0.88
7/8
2.00
0.88
1-1/8
2.06
0.94
2.06
REFRIGERANT
22
134a
404A
507
0.75 OD x 4.00 0.50 OD x 5.00
0.75 OD x 4.00
0.75 OD x 4.00
CP Series
VGA
0.75 OD x 4.00
0.75 OD x 4.00
0.75 OD x 4.00
0.75 OD x 4.00
4.50
Diameter
of Type X
Charge
Diaphragm
Case is 3.62
TYPE M
Outlet Connections
1-1/8 ODF, 1-3/8 ODF, 1-5/8 ODF, M/V flange
Mating Distributors (See Bulletin 20-10)
1115, 1116, 1117, 1119, 1121, 1125, 1126, 1127, 1128,
1143, 1193 (aluminum), 1655(R), 1657(R), 1659(R)
Type
M
MVE-21
22 (V)
407C (N)
407A (V)
422D (V)
134a (J)
12 (F)
401A (X)
409A (F)
404A (S)
502 (R)
408A (R)
507 (P)
402A (L)
W CONNECTIONS - Inches
E ODF Solder Flange
INLET
OUTLET
FLANGE
RING
SIZE
OD x ID
Inches
NET
WEIGHT
STANDARD
TUBING
LENGTH
THERMOSTATIC
CHARGES
AVAILABLE
External
Equalizer
Q
21
MVE-26
26
MVE-34
34
MVE-42
42
MJE-15
15
MJE-20
20
MJE-25
25
MSE-15
15
MSE-20
20
MSE-25
25
MSE-30
30
MPE-15
15
MPE-20
20
MPE-25
25
MPE-30
30
7/8 or 1-1/8
7/8 or 1-1/8
Refer to Recommended
Thermostatic Charges on page 3
REFRIGERANT
(Sporlan Code)
NOMINAL
CAPACITY
Tons of
Refrigeration
VALVE TYPE
5 ft.
1.5 m
10 ft.
3m
7/8 or 1-1/8
7/8 or 1-1/8
7/8 or 1-1/8
1-1/8
1-3/8
or
1-5/8
1.75 x 1.25
8 lbs.
9 lbs.
3.63 kg 4.09 kg
7/8 or 1-1/8
7/8 or 1-1/8
7/8 or 1-1/8
Q Standard External Equalizer Connection 1/4 SAE Flare. 1/4 ODF Solder connection available on request.
W FPT connections also available on request; 1/2 FPT - Part Number 360-000, 3/4 FPT - Part Number 360-001, 1 FPT - Part Number 362-000.
E ODF Solder indicates a female connection on the valve of proper diameter to receive copper tubing of corresponding OD size. Thus, 7/8 ODF will receive 7/8 OD tubing.
3.62
DIMENSIONS
CONNECTIONS - Inches
SOLDERING
BUSHING
7/8
2.38
0.88
1-1/8
2.75
0.94
1-3/8
2.75
0.94
1-5/8
3.22
1.22
2.81
22
0.88 OD x 6.00
CP Series
VGA
4.94
REFRIGERANT
134a
404A
0.88 OD x 6.00
0.88 OD x 6.00
0.88 OD x 6.00
Diameter
of Type X
Charge
Diaphragm
Case is 4.75
507
0.75 OD x 4.00
0.75 OD x 4.00
SHIPPING
WEIGHT
TYPE V
Flanges for the Type V valve are interchangeable with the Type M.
Outlet Connections
1-3/8 ODF, 1-5/8 ODF, M/V flange
Type
V
22 (V)
VVE-52
52
407C (N)
407A (V)
422D (V)
VVE-70
70
VVE-100
100
134a (J)
VJE-35
35
12 (F)
401A (X)
409A (F)
VJE-45
45
VJE-55
55
404A (S)
VSE-38
38
VSE-50
50
VSE-70
70
VPE-38
38
VPE-50
50
VPE-70
70
502 (R)
408A (R)
507 (P)
402A (L)
5 ft.
1.5 m
10 ft.
3m
W CONNECTIONS - Inches
E ODF Solder Flange
INLET
OUTLET
1-1/8
or
1-3/8
1-1/8
1-3/8
or
1-5/8
FLANGE
RING
SIZE
OD x ID
Inches
NET
WEIGHT
STANDARD
TUBING
LENGTH
THERMOSTATIC
CHARGES
AVAILABLE
External
Equalizer
Q
Refer to Recommended
Thermostatic Charges on page 3
REFRIGERANT
(Sporlan Code)
NOMINAL
CAPACITY
Tons of
Refrigeration
VALVE TYPE
SHIPPING
WEIGHT
9 lbs. 10 lbs.
4.09 kg 4.54 kg
1.75 x 1.25
Q Standard External Equalizer Connection 1/4 SAE Flare. 1/4 ODF Solder connection available on request.
W FPT connections also available on request; 1/2 FPT - Part Number 360-000, 3/4 FPT - Part Number 360-001, 1 FPT - Part Number 362-000.
E ODF Solder indicates a female connection on the valve of proper diameter to receive copper tubing of corresponding OD size. Thus, 7/8 ODF will receive 7/8 OD tubing.
3.62
DIMENSIONS
CONNECTIONS - Inches
SOLDERING
BUSHING
7/8
2.38
0.88
1-1/8
2.75
0.94
1-3/8
2.75
0.94
1-5/8
3.22
1.22
4.19
B
4.81
22
0.88 OD x 6.00
CP Series
VGA
REFRIGERANT
134a
404A
0.88 OD x 6.00
0.88 OD x 6.00
0.88 OD x 6.00
0.75 OD x 4.00
0.75 OD x 4.00
507
Diameter
of Type X
Charge
Diaphragm
Case is 4.75
TYPE W
Outlet Connections
1-3/8 ODF, 1-5/8 ODF
Mating Distributors (See Bulletin 20-10)
1117, 1125, 1126, 1127, 1128, 1143, 1657(R), 1659(R)
For complete details of construction, see page 35.
Type
W
407C (N)
407A (V)
422D (V)
134a (J)
12 (F)
401A (X)
409A (F)
135
63
WVE-180
180
G only
WJE-80
80
63
WJE-110
110
G only
FLANGE
RING
SIZE
OD x ID
Inches
CONNECTIONS - Inches
W ODF Solder Flange
10 ft.
3m
INLET
OUTLET
1-1/8
1-3/8
1-5/8
or
2-1/8
1-1/8
1-3/8
1-5/8
or
2-1/8
2.75 x 2.19
10 lbs. 11 lbs.
4.54 kg 4.99 kg
Q Standard External Equalizer Connection 1/4 SAE Flare, 1/4 ODF Solder connection available on request.
W ODF Solder indicates a female connection on the valve of proper diameter to receive copper tubing of corresponding OD size. Thus, 1-1/8 ODF will receive 1-1/8 OD tubing.
E Refer to Recommended Thermostatic Charges, page 3.
R For 1-1/2 NPT connections, order flanges separately for MA42 solenoid eg P/N 933-1. The customer must supply 5/8 diameter x 6 long bolts and 5/8 diameter nuts.
3.38
B
A
2.50
E
0.75
0.53 - Diameter
Bolt Holes
4.56
C
2.06
2.78
0.12
A B
DIMENSIONS
CONNECTIONS - Inches
6.12
FITTING
SIZE
1-1/8
1.12
1.27
1.06
0.91
1.56
3.09
1-3/8
1.38
1.53
1.28
0.97
1.62
3.16
1-5/8
1.62
1.78
1.50
1.09
1.75
3.28
2-1/8
2.12
2.44
1.94
1.34
1.53
3.25
ELEMENT SIZE
NUMBER
Z & ZP Series
X
63
CP Series
REFRIGERANT
134a
0.88 OD x 6.00
0.88 OD x 6.00
0.88 OD x 6.00
0.75 OD x 4.00
VGA
G
22
0.75 OD x 4.00
0.75 OD x 4.00
SHIPPING
WEIGHT
WVE-135
STANDARD
TUBING
LENGTH
ELEMENT
SIZE
NUMBER
22 (V)
External
Equalizer
Q
THERMOSTATIC
CHARGES
AVAILABLE
REFRIGERANT
(Sporlan Code)
NOMINAL
CAPACITY
Tons of
Refrigeration
VALVE TYPE
NET
WEIGHT
*Diameter of
Diaphragm
Case is 3.62
for Small W
and 4.75
for Large W
BODY
SEAT
PIN
PIN
CARRIER
PUSHROD(S)
TYPE OF
JOINTS
CONNECTIONS
INLET
STRAINER
RC
Machined
Brass Bar
Brass Port
Machined
in Body
Stainless
Steel
Stainless
Steel
Knife Edge
to Metal
No Strainer
ER
Machined
Brass Bar
Brass Port
Machined
in Body
Stainless
Steel
Stainless
Steel
Knife Edge
to Metal
No Strainer
Machined
Brass Bar
Brass
Stainless
Steel
Brass
Stainless
Steel
Knife Edge
to Metal
Removable
Strainer
Screen
EF
Machined
Brass Bar
Brass
Stainless
Steel
Brass
Stainless
Steel
Knife Edge
to Metal
Insert
Strainer
Q/
BQ
Machined
Brass Bar
Brass
Stainless
Steel
Brass
Stainless
Steel
Knife Edge
to Metal
SQ/SBQ
Machined
Brass Bar
Brass
Stainless
Steel
Brass
Stainless
Steel
Knife Edge
to Metal
EQ/EBQ
Machined
Brass Bar
Brass
Stainless
Steel
Brass
Stainless
Steel
Knife Edge
to Metal
Brass
Forging
Brass
Stainless
Steel
Brass
Knife Edge
to Metal
EG
Brass
Forging
Brass
Stainless
Steel
Brass
Internally
Equalized:
Triangular
Stainless Steel
Machined
Brass Bar
Brass
Stainless
Steel
Brass
BF
Machined
Brass Bar
Brass
Stainless
Steel
SBF
Machined
Brass Bar
Brass
EBF
Machined
Brass Bar
EBS
Removable
Strainer
Screen
Insert
Strainer
Removable
Strainer
Screen
Externally
Equalized:
Round
Stainless Steel
Knife Edge
to Metal
Knife Edge
to Metal
Stainless
Steel
Knife Edge
to Metal
Stainless
Steel
Stainless
Steel
Knife Edge
to Metal
Brass
Stainless
Steel
Stainless
Steel
Knife Edge
to Metal
Insert
Strainer
Machined
Brass Bar
Brass Port
Machined
in Body
Stainless
Steel
Stainless
Steel
Knife Edge
to Metal
Coarse Mesh
Strainer Disc
Machined
Brass Bar
Brass Port
Machined
in Body
Stainless
Steel
Knife Edge
to Metal
Coarse Mesh
Strainer Disc
LARGE
Machined
Brass Bar
Brass Port
Machined
in Body
Stainless
Steel
Coarse Mesh
Strainer Disc
Machined
Brass Bar
Stainless
Steel or Brass
Stainless
Steel
Brass
Stainless
Steel
Knife Edge
At Element
and
Bottom Cap
Gasket
At Seal Cap
Solder-Flange,
Pipe Flange
Coarse Mesh
Strainer Disc
Bronze
Casting
Stainless
Steel or Brass
Stainless
Steel
Brass
Stainless
Steel
Gasket
Solder-Flange,
Pipe Flange
Coarse Mesh
Strainer Disc
Bronze
Casting
Stainless
Steel
Gasket
Solder-Flange,
Pipe Flange
Coarse Mesh
Strainer Disc
Bronze
Casting
Bronze Piston
With
Synthetic
Sealing
Surface
Dual Port,
Seats
Machined in
Valve Body
Stainless
Steel
Gasket
Solder-Flange,
Pipe Flange
Coarse Mesh
Strainer Disc
SMALL
Brass Piston
With
Synthetic
Seating
Surface
NOTE:MaterialsandConstructionspecificationslistedonthispagemaychangewithoutnotice.ContactSporlanDivisionofParkerforcurrentspecificationsonmaterialsandotherdetailsofconstruction.
Coarse Mesh
Strainer Disc
Removable
Strainer
Screen
CONNECTION
TYPE
VALVE DESCRIPTION
and APPLICATION
TYPICAL
REPLACEMENT TEVs
SAE Flare
or
ODF Solder
Small brass body valve available with either angle style or straight
throughconnections.TypeBIvalveswithstraightthroughconnections are normally supplied non-adjustable. The Type BBI is a Type
BI valve modified to incorporate balanced port construction. The
thermostatic element is not replaceable on valves manufactured
prior to 1994. Current models use a replaceable No. 43 element.
Typicalapplications:smallcapacityR-22airconditioningandheat
pump systems.
BI*/BBI
* BI is OBSOLETE.
Y997-BI
SAE Flare
or
ODF Solder
SAE Flare
or
ODF Solder
Small brass body valve available with either angle style or straight
throughconnections.TypeIvalveswithstraightthroughconnections
arenormallysuppliednon-adjustable.Currentmodelsuseareplaceable No. 43 element. This valve is available with the Rapid Pressure
Balancer (RPB) feature for off-cycle pressure equalization. Typical
applications: small capacity R-22 air conditioning and heat pump
systems.
RC, G, EG, S,
Q, SQ, EQ,
BQ, SBQ, EBQ
Note: A check valve
may be required for
install around the TEV
to allow flow in the
reverse direction.
CBI*/CBBI
RC, G, EG, S,
Q, SQ, EQ,
BQ, SBQ, EBQ
SAE Flare
or
ODF Solder
SAE Flare
or
ODF Solder
Small brass body valve available only with straight through connections and external adjustment. The thermostatic element is not
replaceable on valves manufactured prior to 1994. Current models
use a replaceable No. 43 element. Typical applications: small capacity air conditioning and refrigeration applications where an external
adjustment is desired.
SAE Flare
or
ODF Solder
Brass body valve available with either angle style or straight through
connections.AnglestylevalveisavailableonlywithSAEflareconnections. Type X valves with straight through connections are normally
supplied non-adjustable.Thethermostaticelementisareplaceable
type, size number 53. This valve is available with the Rapid Pressure
Balancer(RPB)featureincertainnominalcapacities for off-cycle pressureequalization.Typicalapplications:R-22airconditioningandheat
pump systems.
* CBI is OBSOLETE.
FB
Special features such as non-adjustable construction or similar modifications are also available for both standard and special
valves when ordered in reasonable quantities.
Automatic (constant pressure) expansion valves are also available on special order.
If you have a special valve application, contact your Sporlan Sales Engineer or Sporlan Division, Parker Hannifin, 206 Lange Drive,
Washington, Missouri 63090, 636-239-1111.