YODIMETRIA, YODOMETRIA
y YODATOMETRIA
There are a lot of redox titrations classified according to the
titrant used.
1) Permanganimetric: Titrant KMnO4
2) Dichromatometric: Titrant K2Cr2O7
3) Titrations involving iodine (I2)
Iodimetry
Iodometry
Titrations that create or consume I2 are widely used in
quantitative analysis.
A reducing agent is the element or compound in a redox
reaction that reduces another species. In doing so, it
becomes oxidized, and is therefore the electron donor in the
redox.
Examples of reducing agents:
The active metals sodium, magnesium, aluminum, and
zinc,
NaH, CaH2, and LiAlH4, which formally contain the Hion.
An oxidaizing agent is the element or compound in a redox
reaction that oxidaizes another species. In doing so, it
becomes reduced, and is therefore the element or compund
that gain electrons.
Examples:
permanganate (MnO4-), chromate (CrO42-), and dichromate
(Cr2O7)2- ions, sodium hypochlorite (bleach) as well as nitric
acid (HNO3), perchloric acid (HClO4), and sulfuric acid (H2SO4)
When a reducing analyte is titrated with iodine (the titrant),
the method is called iodimetry.
Iodimetry: A direct titration with only 1 reaction:
Analyte
unknown
+ titrant (iodine I2) product (iodide I-)
known
When a reducing analyte is titrated with iodine (the titrant),
the method is called iodimetry.
Example: Quantification of Ascorbic Acid (Vitamin C)
C6H8O6 + I2 CH6O6 + 2I- + 2H+
Iodine rapidly oxidizes ascorbic acid, C6H8O6 , to produce
dehydroascorbic acid, C6H6O6 .
Ascorbic acid
Dehydroascorbic acid
Pictures taken from: http://en.wikipedia.org
Iodometry is the titration of iodine (I2) produced when an
oxidizing analyte is added to excess I- (iodide).
Then the iodine (I2) is usually titrated with standard
thiosulfate solution.
Iodometry: Not a direct titration because there are 2 reactions:
analyte
unknown
I2
+
+
I-
I2
titrant (standard thiosulfate)
Known
product
Iodimetric titrations:
a) A reducing analyte
b) One reaction
c) Standard solution: Iodine (I2)
Iodometric titrations:
a) An oxidizing analyte
b) Two reactions
c) Standard solution: Sodium thisoufate
Analytical applications:
Iodimetric titrations:
Species analyzed (reducing analytes)
SO2
H2S
Zn2+ , Cd2+ , Hg2+ , Pb2+
Cysteine, glutathione, mercaptoethanol
Section of a protein structure
Source: http://en.wikipedia.org
Glucose (and other reducing sugars)
Analytical applications:
Iodometric titrations:
Species analyzed (oxidizing analytes)
HOCl
Br2
IO3- ,
O2,
IO4H2O2,
O3
NO2Cu 2+
MnO4-,
MnO2
Example: Quantification of Copper
2 Cu
2+
4I-
2CuI
I2
Analyte of
unknown
concentration
I2
2S2O32-
2I-
Titrant
-standrard solutions: sodium
thiosulfate
-known concentration
S4O62-
Fact File 1: Introduction to iodometric and iodimetric titrations
In this lesson: Iodometric titration of copper
Sample: Copper wire (solid)
First: Dissolve the sample
copper wire Cu0 dissolution Cu 2+
Copper ion: oxidizing agent
Second: Pre-treatment of the sample
Fact File 1: Introduction to iodometric and iodimetric titrations
Third: Iodometric titration
2 Cu
2+
4I-
2CuI
I2
Analyte of
unknown
concentration
I2
2S2O32-
2I-
Titrant
-standrard solutions: sodium
thiosulfate
-known concentration
S4O62-
APLICACIONES PARA LAS
VALORACIONES
YODOMETRICAS
Preadjustment of analyte oxidation state
It is necessary to adjust the oxidation state of the analyte to one that can be titrated
with an auxiliary oxidizing or reducing agent.
Ex.
Preadjustment by auxiliary reagent
Fe(II), Fe(III)
Fe(II)
4
Titration
Ce4+
Preoxidation :
Peroxydisulfate ( (NH4)22S) 2O8 )
Sodium bismuthate ( NaBiO 3)
Hydrogen peroxide (H2O2)
Prereduction : Stannous chloride ( SnCl2)
Chromous chloride
Jones reductor (zinc coated with zinc amalgam)
Walden reductor ( solid Ag and 1M HCl)
920310
http:\\asadipour.kmu.ac.ir 33 slides
15
Reagents used in redox titration
Reducing agents
1) ammonium iron(II) sulfate hexahydrate (Mohrs salt)
FeSO 4(NH4)2SO4 6H2O
2) iron(II) ethylene diamine sulfate (Oespers salt) FeC2H4(NH3)2(SO4)2 4H2O
3) Sodium thiosulfate pentahydrate
4) Arsenic trioxide: arsenious oxide
Na2S2O35H2O
As2O3
5) Sodium oxalate and oxalic acid dihydarte
920310
Na2(COO)2 ,
http:\\asadipour.kmu.ac.ir 33 slides
(COOH)22H2O
18
Standardization of thiosulfate solution:
Primary standard : potassium iodate (KIO3), K2Cr2O7, KBrO3
Titration reactions:
KIO3 + 5KI + 6HCl
I2 + 2Na2S2O3
KIO3
3I2 + 6KCl + 3 H2O
2NaI + Na2S4O6
3I2
6Na2S2O35H2O
6 Equivalent
S2O32- +H+ HSO3- +S(s)
pH, Microorganisms, Concentration, Cu2+, Sunlight
Stabilizer for sodium thiosulfate solution : Na2CO3
Na2S2O3 + H2O + CO2
H2S2O3
920310
Na2CO3 + H2S2O3
H2SO3 + S
http:\\asadipour.kmu.ac.ir 33 slides
20
920310
http:\\asadipour.kmu.ac.ir 33 slides
21
16-2 Finding the end point
A redox indicator is a compound
that changes color
when it goes from its oxidized
to its reduced state.
or
For ferroin, with E = 1.147 V
we expect the color change to occur in the approximate range
1.088 V to 1.206 V with respect SHE
920310
http:\\asadipour.kmu.ac.ir 33 slides
22
920310
http:\\asadipour.kmu.ac.ir 33 slides
23
Starch-Iodine Complex
Starch is the indicator of choice for those procedures
involving iodine because it forms an intense blue colour
with iodine.
Starch is not a redox indicator;
it responds specifically to the presence of I2,
not to a change in redox potential.
Structure of the repeating unit
of the sugar amylose.
920310
http:\\asadipour.kmu.ac.ir 33 slides
24
Arsenious oxide, As4O6
As4O6 + 6H2O = 4H3AsO3
H3AsO3 + I3 + H2O = H3AsO4 + 3I + 2H+
920310
http:\\asadipour.kmu.ac.ir 33 slides
25
Reagents used in redox titration
Oxidizing agents
1) Potassium permanganate KMnO4 :
Permanganometry
2) Ceric sulfate / Ceric ammonium sulfate
3) Potassium dichromate K2Cr2O7
4) Iodine I2 :
Ce(SO4)22(NH4)2SO4 4H2O : Cerimetry
Dichrometry
Iodimetry, Iodometry
5) Potassium iodate
KIO3
: Iodatimetry
6) Potassium bromate KBrO3 : Bromatimetry
920310
http:\\asadipour.kmu.ac.ir 33 slides
26
920310
http:\\asadipour.kmu.ac.ir 33 slides
27
Permanganate titration
Oxidation with permanganate : Reduction of permanaganate
KMnO4 Powerful oxidant that the most widely used.
1) In strongly acidic solutions (1M H2SO4 or HCl, pH
MnO4 + 8H+ + 5e = Mn2 + + 4H2 O
1)
Eo = 1.51 V
KMnO4 is a self-indicator.
2) In feebly acidic, neutral, or alkaline solutions
MnO4 + 4H+ + 3e = MnO2 (s) + 2H2 O
Eo = 1.695 V
3) In very strongly alkaline solution (2M NaOH)
MnO4 + e = MnO42
920310
http:\\asadipour.kmu.ac.ir 33 slides
Eo = 0.558 V
28
Permanganate titration
Duration of colour in end point (30 seconds)
MnO4 + 3Mn2+ + 2H2O 5MnO2 + 4H+
K=1*1047
Stability of aqoues solution of MnO4MnO4 + 2H2O 4MnO2 (s) + 3O2 (g) +4OH-
920310
http:\\asadipour.kmu.ac.ir 33 slides
29
Standardization of KMnO4 solution
Potassium permanganate is not primary standard, because traces of MnO2
are invariably present.
Standardization by titration of sodium oxalate (primary standard) :
2KMnO4 + 5 Na2(COO)2 + 8H2SO4 = 2MnSO4 + K2SO4 + 5Na2SO4 + 10 CO2 + 8H2O
2KMnO4
920310
5 Na2(COO)2
10 Equivalent
http:\\asadipour.kmu.ac.ir 33 slides
30
Preparation of 0.1 N potassium permanganate solution
KMnO4 is not pure.
Distilled water contains traces of organic reducing substances
which react slowly with permanganate to form hydrous managnese dioxide.
Manganesse dioxide promotes the autodecomposition of permanganate.
1)
Dissolve about 3.2 g of KMnO4 (mw=158.04) in 1000ml of water,
heat the solution to boiling, and keep slightly below the boiling point for 1 hr.
Alternatively , allow the solution to stand at room temperature for 2 or 3 days.
2)
Filter the liquid through a sintered-glass filter crucible to remove solid MnO2.
3)
Transfer the filtrate to a clean stoppered bottle freed from grease with cleaning
mixture.
4)
Protect the solution from evaporation, dust, and reducing vapors, and keep it in the
dark or in diffuse light.
5)
If in time managanese dioxide settles out, refilter the solution and restandardize it.
920310
http:\\asadipour.kmu.ac.ir 33 slides
31
Applications of permanganometry
(1) H2O2
2KMnO4 + 5 H2O2 + 3H2SO4 = 2MnSO4 + K2SO4 + 5O2 + 8H2O
(2) NaNO2
2NaNO2 + H2SO4 =
Na2SO4
+ HNO2
2KMnO4 + 5 HNO2 + 3H2SO4 = 2MnSO4 + K2SO4 + 5HNO3 + 3H2O
(3) FeSO4
2KMnO4 + 510 FeSO4 + 8H2SO4 = 2MnSO4 + K2SO4 + 5Fe2(SO4)3 + 8H2O
(4) CaO
CaO + 2HCl = CaCl2 + H2O
CaCl2 + H2C2O4 = CaC2O4 + 2HCl
(excess oxalic acid)
2KMnO4 + 5 H2C2O4 + 3H2SO4 = 2MnSO4 + K2SO4 + 10CO2 + 8H2O (back tit)
(5) Calcium gluconate
[CH2OH(CHOH)4COO]2Ca + 2HCl = CaCl2 + 2CH2OH9CHOH)4COOH
(NH4)2C2O4 + CaCl2 = CaC2O4 + 2 NH4Cl
CaCl2
+ H2SO4 =
9203102KMnO
H2C2O4 + CaSO4
http:\\asadipour.kmu.ac.ir
33 slides
+ 5 H2C2O4 + 3H2SO
4 = 2MnSO4 + K2SO4 + 10CO2 + 8H2O
33
Oxidation with Ce4+
Ce4+ + e = Ce3+
1.7 V in 1 N HClO4
yellow
1.61 V in 1N HNO3
colorless
1.47 V in 1N HCl
1.44 V in 1M H2SO4
Indicator : ferroin, diphenylamine
Preparation and standardization:
Ammonium hexanitratocerate, (NH4)2Ce(NO3)6, (primary standard grade)
Sodium oxalate.
920310
http:\\asadipour.kmu.ac.ir 33 slides
34
920310
http:\\asadipour.kmu.ac.ir 33 slides
35
Applications of cerimetry
(1) Menadione (2-methylnaphthoquinon: vitamin K3)
HCl, Zn
O
CH3
OH
CH3
Reduction
2 Ce(SO4)2
OH
(2) Iron
2FeSO4 + 2 (NH4)4Ce(SO4)4 = Fe2(SO4)3 + Ce2(SO4)3 + 4 (NH4)2SO4
920310
http:\\asadipour.kmu.ac.ir 33 slides
36
Oxidation with potassium dichromate
Cr2O72 + 14H+ + 6e = 2Cr3+ + 7H2O
Eo = 1.36 V
K2Cr2O7 is a primary standard.
Indicator : diphenylamine sulphonic acid
920310
http:\\asadipour.kmu.ac.ir 33 slides
37
Ex. Redox titration ( hydroquinone vs dichromate standard solution )
Cr2O72 + 14H+ + 6e
3
HO
3 HO
2 Cr3+ + 7 H2O
OH
Eo= 1.33
OH + Cr2O72 + 8H+
+ 2H+ + 2e
Eo= 0.700
O + 2 Cr3+ + 7 H2O
3O
Eo= Eocathode Eoanode = 1.33 0.700 = 0.63 V
K = 10 nEo/0.05916 = 10 6(0.63) / 0.05916 = 10 64
redox indicator : diphenylamine
920310
colorless to
violet
Very large : quantitative : complete reaction
http:\\asadipour.kmu.ac.ir 33 slides
38
Iodimetry and iodometry
Iodimetry:
a reducing analyte is titrated directly with iodine (to
produce I).
I2 + V.C 2I- +
iodometry :
an oxidizing analyte is added to excess I to produce
iodine, which is then titrated with standard thiosulfate
solution.
I- + Cu2+ I2 + Cu+
I2 + S2O32- 2I- + S4O62-
920310
http:\\asadipour.kmu.ac.ir 33 slides
39
standard I31) Iodine only dissolves slightly in water. Its solubility is
enhanced by interacting with I-
2) An excellent way to prepare standard I3- is to add a weighed
quantity of potassium iodate to a small excess of KI. Then
add excess strong acid (giving pH 1) to produce I3- by
quantitative reverse disproportionation:
3) Cu2++4I- 2CUI + I2
920310
http:\\asadipour.kmu.ac.ir 33 slides
40
Stability of I2 Solutions
In acidic solutions of I3- are unstable because the
excess I is slowly oxidized by air:
In neutral solutions, oxidation is insignificant in the
absence of heat, light, and metal ions.
At pH 11, triiodide disproportionates to hypoiodous
acid (HOI), iodate, and iodide.
I2 + OH- IO- + I- + H+
920310
3IO- IO3- + 2I-
http:\\asadipour.kmu.ac.ir 33 slides
41
920310
http:\\asadipour.kmu.ac.ir 33 slides
44
Determining water with the Karl Fisher Reagent
The Karl Fisher reaction :
I2 + SO2 + 2H2O
2HI + H2SO4
For the determination of small amount of water, Karl Fischer(1935) proposed a
reagent prepared as an anhydrous methanolic solution containing iodine, sulfur
dioxide and anhydrous pyridine in the mole ratio 1:3:10. The reaction with water
involves the following reactions :
C5H5NI2 + C5H5NSO2 + C5H5N + H2O
C5H5N+SO3 + CH3OH
2 C5H5NHI + C5H5NSO3
C5H5N(H)SO4CH3
Pyridinium sulfite can also consume water.
C5H5N+SO3 + H2O
C5H5NH+SO4H
It is always advisable to use fresh reagent because of the presence of various side
reactions involving iodine. The reagent is stored in a desiccant-protected container.
The end point can be detected either by visual( at the end point, the color changes
from dark brown to yellow) or electrometric, or photometric (absorbance at 700nm)
titration methods. The detection of water by the coulometric technique with Karl
Fischer reagent is popular.
920310
http:\\asadipour.kmu.ac.ir 33 slides
45
BROMATOMETRIA
Es el mtodo de las oxidoreductimetrias donde se emplean
las reacciones de in bromato, (BrO3)1-
(BrO3)1- + 6 H+
Pot +1,45 v
6e-
Br1-
3 H2O
Por tanto, el equivalente gramo ser 1/6 del Peso Formula.
(167,01 / 6) = 27,84
Puede observarse que el medio tiene que ser
necesariamente cido. Como el bromato necesita realizarse
en caliente y en medio fuertemente cido.
Durante la titulacin los iones bromato se reducen a bromuro, que
al aparecer en el medio, en presencia de iones bromato,
reaccionan con este oxidndose.
(BrO3)1- + 6 H+
+ 5 Br1-
3 Br2
3 H2O
El bromo libre que se forma colorea la solucin de amarillo plido.
Este color es imposible de observar con precisin en el punto de
equivalencia. Pero existen colorantes organicos que se oxidan
irreversiblemente con el bromo y la solucin coloreada con ellos
se decolora. Algunos de estos colorantes son el anaranjado de
metilo y el rojo de metilo.
La solucin patrn que se emplea en bromatometra es la 0,10N,
preparada por pesada directa de la sal seca. Pero puede usarse
la solucin 0,010N (contiene 2,7835 g de sal por litro)
Se emplea para valorar, por ejemplo, fenoles