CI/SfB
(23.9)
Rm1
(P2)
December 2006 (replaces November 2006 issue)
Construction type
Roofs
Application type
Acoustic
Rockwool Acoustic Infill
High performance sound absorption for perforated metal decks
Rockwool Acoustic Infill consists of
trapezoidal shaped tissue faced Rockwool
insulation, which is engineered to suit
specified perforated roof decking.
The combination of optimised density, fibre
direction and excellent fit provides a
significant improvement in sound absorption
when used together with Rockwool Hardrock
Dual Density Roofing Board on perforated
metal roof decking constructions.
Advantages
Excellent acoustic absorption
- Class C sound absorption performance
Pre-cut to suit specific roof deck sizes for
fast installation
Vapour control layer can be installed directly
onto the roof decking
Tissue faced on all sides for enhanced
aesthetic appearance
Description, performance and properties
Description
Performance & Properties
Rockwool Acoustic Infill D60
Acoustic Performance
Solution to E3 and E4 of the Approved Document E
Dimensions
Length: 1000mm
Profile: To suit Corus D60 perforated roof decking
Other profile sizes available on request.
Standards and approvals
The product is manufactured in full accordance with the
ISO 9001:2000 Quality Management System.
A perforated metal deck construction including Rockwool Acoustic Infill and Hardrock DD
Roofing Board will achieve Classification C sound absorption rating in accordance with BS EN
ISO 11654:1997. See Typical applications. Method A as determined by E3 and E4 of Approved
Document E can generally be satisfied by the use of ceilings with Class C sound absorption. See
Approved Document E, and Building Bulletin 93 (The Acoustic Design of Schools) for guidance.
Fire Performance
The Rockwool used in the manufacture of this product is non-combustible.
Thermal Conductivity
The Thermal Conductivity () of Rockwool Acoustic Infill is 0.040W/mk.
Resistance to moisture
UKAS
QUALITY
MANAGEMENT
Rockwool Acoustic Infill is water-repellent and unaffected by the freeze/thaw cycle.
003
Certificate No FM 02262
UKAS
QUALITY
MANAGEMENT
003
UKAS
ENVIRONMENTAL
MANAGEMENT
003
Certificate No FM 02262 Certificate No EMS 70301
Associate Member
Construction and installation guidance
Typical Applications
Design
Flat roof areas over convention and sports halls,
manufacturing plants, entrance halls, corridors, hallways
and stairwells etc.
The roof construction and design should comply with BS
6229:2003 (Code of practice for flat roofs with continuous
supported coverings).
Mechanically fastened single ply membrane system
Vapour control layer
The need for a vapour control layer should be calculated in
accordance with BS 5250: 2002 (Code of practice for control
of condesation in buildings) and with reference to BS 6229:
2003 (Code of Practice for Flat Roofs with Continuously
Supported Coverings).
Storage and handling
Rockwool Acoustic Infill is supplied to site in cardboard
cartons. Store in dry conditions
Supply
Available throughout the United Kingdom from Rockwool
stockists. A list is available on request.
Specify SPRA
The Single Ply Roofing Association (SPRA) represents
membrane manufacturers, associated component
manufacturers and specialist subcontractors and aims to
ensure the delivery of best value single ply roofing systems,
through a quality assured partnership. By specifying
products and specialist installation by SPRA Manufacturer,
Associate and Contractor members you can be assured that
all parties meet strict quality criteria.
D60 webb perforated steel deck 13% open area
Rockwool Acoustic Infill D60
Polythene vapour control layer (VCL), 0.22mm
Rockwool Hardrock DD Roofing Board,
210mm (105 + 105mm)
Mechanically fastened single ply membrane system
U value: 0.18W/m2K
Frequency (Hz)
125
250
500
1K
2K
4K
Sound absorption
coefficient
0.55
0.94
1.09
0.95
0.59
0.44
Compliance with these criteria and with the Code of
Conduct is assessed at application, by annual audit and by
random spot checks. For further information, and to obtain
copies of the SPRA Design Guide and other documents, go
to www.spra.co.uk or call 0115 914 4445
Rockwool Limited reserves the right
to alter or amend the specification of
products without notice as our policy
is one of constant improvement.
The information contained in this
data sheet is believed to be correct
Associate Member
Weighted Sound Absorption Coefficient
Noise Reduction Coefficient
Absorption Classification
Weighted Sound Reduction Index
W = 0.6(LM)
NRC = 0.90
Class C
Rw = 39dB
C/06/5L3434/2, C/06/5L/3434/1
Fully bonded single ply membrane system
D60 webb perforated steel deck 13% open area
Rockwool Acoustic Infill D60
Bituminous Vapour control layer (VCL)
Rockwool Hardrock DD SPA Roofing Board,
210mm (105 + 105mm)
Fully bonded single ply membrane system
at the date of publication. Whilst
Rockwool will endeavour to keep its
Health and safety
publications up to date, readers will
appreciate that between publications
Current HSE CHIP Regulations and EU directive 97/69/EC
confirm the safety of Rockwool mineral wool; Rockwool
fibres are not classified as a possible human carcinogen.
there may be pertinent changes in the
The maximum exposure limit for mineral wool is 5mg/m3,
8 hour time-weighted average.
The above applications do not
law, or other developments affecting
the accuracy of the information
contained in this data sheet.
necessarily represent an exhaustive
list of applications for Rockwool
A Material Safety Data Sheet is available from the Rockwool
Marketing Services Department to assist in the preparation
of risk assessments, as required by the Control of Substances
Hazardous to Health Regulations (COSHH).
Acoustic Infill. Rockwool Limited does
not accept responsibility for the
consequences of using Rockwool
Acoustic Infill in applications
different from those described above.
Expert advice should be sought where
See above for sound absorption coefficients.
Environment
such different applications are
contemplated, or where the extent of
Installation
Apply the Rockwool Acoustic Infill strips directly within the
troughs of the metal deck. Ensure that all joints are tightly
butted together. Where lengths of Rockwool Acoustic Infill
require to be cut, this is easily facilitated with a sharp knife.
Follow with the installation of the appropriate VCL,
Rockwool insulation and waterproofing layer in accordance
with the manufacturers requirements. Day joints must be
formed at the conclusion of each section of work to seal
exposed edges of the Rockwool Acoustic Infill and Hardrock
DD roofing board. For roof board installation, see the
Hardrock DD data sheet.
Rockwool insulation relies on entrapped air for its thermal
properties; air is not a VOC and it does not have Global
Warming Potential (GWP) or Ozone Depleting Potential (ODP).
ZERO
GWP
ZERO
ODP
GLOBAL
WARMING
POTENTIAL
OZONE
DEPLETING
POTENTIAL
any listed application is in doubt.
Rockwool Limited
Pencoed. Bridgend. cf35 6ny
e [email protected]
www.rockwool.co.uk
Technical Information
For further details visit our website at
www.rockwool.co.uk or phone the
Technical Hotline on 0871 222 1780