Product Description:
Product Dimensions:
The Lumination BT Series LED Luminaire is a commercial ceiling troffer that
provides high uniformity, excellent efficiency and reduced glare in T-grid
ceiling applicaitons. The improved lumen maintenance of L70 of initial
lumens at 50,000 hours of operation, allows lower maintenance costs
over time. It is suitable for indoor general lighting.
Targeted Performance Summary:
Distribution Patterns: Lambertian
Delivered Lumen Output: 3100 Lm (3500K); 3300 Lm (4000K)
System Input Power: 35W
Efficacy: 88 LPW (typical for 3500K); 95 LPW (typical for 4000K)
Input Voltage: 120-277V for UL version, 220-240V for CE version
CCT: 3500K, 4000K
Typical CRI: 80 +, R9: >0
Color Consistency: 4 Step MacAdam Ellipse
Lifetime Rating: 50,000 Hours @ L70
Input Frequency (Hz): 50/60Hz
Power Factor: >0.9
Dimensions: UL Version: 23.7 in x 23.7 in x 3.3 in
CE Version: 595 mm x 595 mm x 83 mm
THD: <20%
Mounting: Fits standard T-Bar grid (drop ceilings)
Maximum Weight: <11 lbs
Limited Warranty: 5 Years Standard
Files Available: LM79, LM80, IES
UL Version: A = 23.7 in [603 mm] B =23.7 in [603 mm] C = 3.3in [83 mm]
CE Version: A = 595 mm B = 595 mm C = 83 mm
Certified by:
Ordering Information:
B
_ _T
INTERNAL
CODE
BT
- _ _
FIXTURE TYPE
(NOMINAL)
22 = 2 x 2
- __ -
A
_
VOLTAGE
OPTICAL
CODE
MOUNTING
LOGIX COMPATIBLE
CONTROLLER
A = T-Grid, Bolt Slot
P = Non-Dimming
0 = 120-277V
(UL Version)
7 = 220-240V
(CE Version)
- _W_H _T E_ -
__
OPTIONS
FINISH
WHTE = White
OPTICAL
CODE
DISTRIBUTION
TYPE
A2
A3
Lambertian
Lambertian
Blank if no options
H = Chicago Plenum, CCEA
EL = Emergency Light
CRI
80
80
COLOR TEMP
(K)
TYPICAL
LUMENS
SYSTEM
WATTAGE
3500
4000
3100
3300
35
35
Photometric Data: LuminationTM 2 x 2 Recessed Troffer BT 22 Series
2BY2 UL.IES
CANDLEPOWER SUMMARY
0 30 60 90
0
5
10
15
20
25
30
35
40
45
50
55
60
65
70
75
80
85
90
1256 1256 1256 1256
1249 1249 1249 1249
1228 1228 1228 1228
1192 1193 1193 1194
1144 1145 1146 1146
1084 1085 1087 1087
1013 1014 1016 1017
934 935 937 938
847 849 851 852
756 758 760 761
662 663 666 667
567 568 571 572
473 474 476 477
382 383 384 385
294 295 295 295
210 210 209 209
130 130 128 128
54 54 52 52
3 2 0 1
COEFFICIENTS OF UTILIZATION
RC
80%
70%
50%
30%
10%
0%
RW 70% 50% 30% 10% 70% 50% 30% 10% 50% 30% 10% 50% 30% 10% 50% 30% 10% 0%
0 119 119 119 119 116 116 116 116 111 111 111 106 106 106 102 102 102
1 109 104 100
96 106
102
98 95 98 94 92 94 91 89 90 88 86
2 99 91 84 79 97 89 83 78 86 80 76 82 78 74 79 76 72
3 91 80 72 66 88 79 71 65 76 69 64 73 67 63 70 66 62
4 83 71 62 56 81 70 62 55 67 60 55 65 59 54 63 57 53
5 76 64 55 48 74 63 54 48 60 53 47 58 52 47 57 51 46
6 71 57 49 42 69 56 48 42 55 47 42 53 46 41 51 45 41
7 66 52 43 37 64 51 43 37 50 42 37 48 42 37 47 41 36
8 61 48 39 33 60 47 39 33 46 38 33 44 38 33 43 37 33
9 57 44 36 30 56 43 35 30 42 35 30 41 34 30 40 34 30
10 54 40 33 27 52 40 32 27 39 32 27 38 32 27 37 31 27
NOTE: Floor Cavity Reflectance : 20%
ZONAL LUMEN SUMMARY
Zone
Lumens
% of Fixture
0-30 954.72
0-40 1540.06
0-60 2635.26
0-90 3303.03
28.9
46.6
79.8
100
LUMINANCE DATA (CANDELA/m2)
Gamma
45
55
65
75
85
0
3019
2790
2552
2287
1746
POLAR GRAPH
45
90
1369
3032
2807
2565
2289
1758
3041
2815
2570
2285
1677
1027
685
342
2
1
CO - C180
C90 - C270
Product Specifications:
Construction:
Optical System:
Durable, long lasting bezel construction. Steel, Electrogalvanized, Cold-rolled,
Commercial quality coated with Electrostatic Powder Coat Paint
IP Rating: IP30
Impact Resistance: IK=03
Electrical System:
Class 2, replaceable, high efficiency LED driver rated for 50,000 hours when used
within operating conditions.
Thermal overload protection shuts down the luminaire when system
temperatures exceed designed operating conditions
THD: <20%
Transient Protection: 100 kHz ring wave, 2 kV level condensing)
Input Current: 120V/35W - 290mA
230V/35W - 150mA
277V/35W - 130mA
Precision formed optical assembly comprised of high specularity reflectors,
and a transmissive lens.
High optical grade lens providing good efficiency and impact resistance
Luminance Uniformity: 3:1 max to min
No visible diodes
Installation:
Drivers and internal components accessed via plenum.
Suitable for dry locations.
L shape mounting brackets provided with luminaire. Mounting holes provided for hanging wire.
Integrated galvanized PSU enclosure delivers low profile and ease of installation
Luminaire Vibration Testing: Luminaire test to 0.5 G, 100,000 cycles per axis, 2 axis
For more information and access to all of our resources, including our
design tool visit: www.gelighting.com
GE Lighting 1-888-MY-GE-LED (1 - 888 - 69 - 43 - 533) www.gelighting.com