Pietro Fiorentini

The Reflux 919 Control is a pneumatic control valve designed for use with natural gas. It has an absolute tight shut off and very high rangeability of 1:500. The valve has a long trim life, low noise, and is easy to maintain with standardized parts. Table 1 provides capacity information for valve sizes ranging from 1" to 10" including flow coefficients. The document also includes dimensional drawings, material specifications, and equations for calculating flow rates based on inlet pressure and valve coefficients.

Uploaded by

RadityaA.Perdana
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
354 views6 pages

Pietro Fiorentini

The Reflux 919 Control is a pneumatic control valve designed for use with natural gas. It has an absolute tight shut off and very high rangeability of 1:500. The valve has a long trim life, low noise, and is easy to maintain with standardized parts. Table 1 provides capacity information for valve sizes ranging from 1" to 10" including flow coefficients. The document also includes dimensional drawings, material specifications, and equations for calculating flow rates based on inlet pressure and valve coefficients.

Uploaded by

RadityaA.Perdana
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 6

CT 222/E

UNEQUALLED HIGH
TURNDOWN (1:500)
LOW-NOISE TRIM

REFLUX 919 CONTROL

ABSOLUTE TIGHT SHUT OFF


UNEQUALLED HIGH TURNDOWN
(1:500)
LONG TRIM LIFE
EASY MAINTENANCE
STANDARDIZED PARTS

LOW-NOISE TRIM
HIGH CAPACITY
HIGH ACCURACY
HIGH STABILITY
PRESSURE CLASSES: S150,
S300, S600

The Reflux 919 Control is a pneumatic control valve,


specifically designed for use of natural gas, commonly operated by a direct acting type diaphragm
actuator (mod. 200) or reverse acting type diaphragm actuator (mod. 300).
- The control loop is 6-30 psig: other signals available on application
- The absolute tight shut off is obtained by the soft
seated patented Fiorentini design

- Very high rangeability due to special plug guiding


(1:500)
- The actuator design has a special balanced valve
plug for minimum actuator requirement
- Maximum inlet pressure 85 bar
- Maximum pressure drop 83 bar
- Nace MR 01/75 version available on request
- Retrofitting capability by built-in special silencer
and Fiorentini patented channel flow trim.

Table 1 - Capacity information


Size

10

Kg

605

2.335

5.194

8.416

17.471

27.282

38.425

Cg

575

2.200

4.937

8.000

16.607

25.933

36.525

Cv

18

69

154

250

519

810

1141

CHOOSING THE SIZE OF THE VALVE


Choise of the valve is usually on the basis of Cg valve
and KG flow rate coefficients. Cg coefficient corresponds numerically to the value of air flow in SCF/H in
critical conditions with full open valve operating with
an upstream pressure of 1 psia at a temperature of
15C. KG coefficient corresponds numerically to the
value of natural gas flow rate in Stm/h in critical conditions with full open valve operating with an upstream
pressure of 2 bar abs at a temperature of 15C.
Flow rates at full open position and various working
conditions, are bound by the following formule where:

(valid for Pe < 2 Pa)


1.2 in critical conditions:

(valid for Pe 2 Pa)

Pe = inlet pressure in bar (abs)


Pa = outlet pressure in bar (abs)
Q = flow rate in Stm/h
KG, Cg = valve coefficients

Q = 0.525 Cg Pe (valid for Pe 2 Pa)


2 Viceversa, when values of Pe, Pa and Q are known
calculate the values of Cg or KG with:

1. When valves Cg and KG and values of Pe and Pa


are known

2.1 in non critical-conditions:


1.1 in non critical conditions:

(valid for Pe < 2 Pa)

(valid for Pe < 2 Pa)

(valid for Pe < 2 Pa)

As already mentioned Cg and KG values are related


to a fully-open valve.
Diagram of fig. 1 gives the values of Cg and KG
coefficients in function of plug lift. Both coefficient
values and plug lift are expressed in percentage of
the maximum value.

2.2 in critical conditions:

VALVE CHARACTERISTICS Cg and KG


Cg, Kg%
100
90
80

(valid for Pe 2 Pa)

70

A oversizing of 20% on calculated values is raccomanded.

60

Cg formulae give flow rate values more correct


while KG formulae give values 5% higher than real
ones only in noncritical conditions.
In the case of noise limitation level a speed at the
outlet flange of 130 m/sec. it is also raccomanded.
Above formulae are valid for natural gas with a relative specific gravity of 0,61 compared to air and
temperature of 15C at inlet.
For gases with different relative specific gravity (S)
and temperature t (in C), value of flow rate calculated as above, must be adjusted multiplying by:

40

50

30
20
10
0
0

10

20

30

40

50

Fig. 1

60

70

80

90

100

Opening

VALVE CHARACTERISTICS
Modified equal percent, inherent linear (easily) characterizable with positioner CAM)

Table 2- STD MATERIAL INFORMATION


PART

MATERIAL

SEAT RING

Vulcanized nitril TN040

BODY
VALVE STEM

ASTM A216 WCB


AISI 416

PISTON

Carbon steel

DIAPHRAGM PLATES

Carbon stell

SEALS

Viton

G
A
H
P

DN

DN

Direct action version

OVERALL DIMENSIONS in mm. WEIGHTS


25

50

80

100

150

200

250

10

ANSI 150

183

254

298

352

451

543

673

ANSI 300

197

267

317

368

473

568

708

ANSI 600

Size

210

286

336

394

508

609

752

550

580

615

645

670

720

830

A*

503

533

568

598

657

707

817

100

130

150

190

225

265

340

375

375

375

375

495

495

630

130

160

200

250

275

320

440

640

660

715

755

755

820

930

G*

593

613

668

708

742

807

917

650

710

765

835

895

985

1170

H*

603

663

718

788

882

972

1157

170

200

235

265

300

350

460

* dimensions only for direct action

Weights - Kgf
ANSI 150

35

53

75

117

210

330

ANSI 300

40

58

85

140

280

390

600

ANSI 600

41

60

90

145

300

420

700

G
A
H
P

DN

DN

Direct action version

OVERALL DIMENSIONS in mm. WEIGHTS


25

50

80

100

150

200

250

10

ANSI 150

183

254

298

352

451

543

673

ANSI 300

197

267

317

368

473

568

708

ANSI 600

Size

210

286

336

394

508

609

752

750

805

885

955

955

1055

1330

A*

703

758

838

908

942

1042

1317

100

130

150

190

225

265

340

375

375

375

375

495

495

630

130

160

200

250

275

320

440

840

885

985

1065

1040

1155

1430

G*

793

838

938

1018

1027

1142

1417

850

935

1035

1145

1180

1320

1670

H*

803

888

988

1098

1167

1307

1657

370

425

505

575

585

685

960

* dimensions only for direct action

Weights - Kgf
ANSI 150

58

93

135

207

405

620

ANSI 300

63

108

167

240

480

665

1000

ANSI 600

64

112

175

263

500

705

1130

CT 222/E

I dati sono indicativi e non impegnativi. Ci riserviamo di apportare eventuali modifiche senza preavviso.
The data are not binding. We reserve the right to make modification without prior notice.

Pietro Fiorentini S.p.A.


I-20124 MILANO
I-36057 ARCUGNANO (VI)
I-80142 NAPOLI

Italy - Via Rosellini, 1 - Phone +39.02.6961421 (10 linee a.r.) - Telefax +39.02.6880457
E-mail: [email protected]
Italy - Via E. Fermi, 8/10 - Phone +39.0444.968511 (10 linee a.r.) - Telefax +39.0444.960468
E-mail: [email protected]
Italy - Via B. Brin, 69 - Phone +39.081.5544308 - +39.081.5537201 - Telefax +39.081.5544568

ASSISTENZA POST-VENDITA E SERVIZIO RICAMBI: - SPARE PARTS AND AFTER-SALES SERVICE:

I-36057 ARCUGNANO (VI) - Italy - Via E. Fermi, 8/10 - Phone +39.0444.968511 (10 linee a.r.) - Telefax +39.0444.968513 - E-mail: [email protected]

Edigraf srl 03/2000

UFFICI COMMERCIALI: - OFFICES:

You might also like