100% found this document useful (1 vote)
557 views8 pages

Honeywell Hbs Fire System Options Brochure

introucion

Uploaded by

rahu2260
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
100% found this document useful (1 vote)
557 views8 pages

Honeywell Hbs Fire System Options Brochure

introucion

Uploaded by

rahu2260
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 8

Building Solutions

One Honeywell Solution


for All of Your Fire Systems Needs

Intelligent and Accurate Detection


Fire/CO
The Advanced Multi-Criteria Fire/CO Detector is a plug-in, addressable device that
provides both fire and Carbon Monoxide (CO) detection. For fire, the detector combines
four separate sensing elements in one unit (smoke, CO, infrared and heat) to sense
multiple components of a fire. This approach has enhanced sensitivity to a real fire with
heightened immunity to nuisance particulate. For CO, the detectors electrochemical
sensing cell creates a separate signal for life safety CO detection. When used together
with our addressable sounder base, you can replace as many as four separate devices
for a cleaner and more efficient installation.

COPTIR
COPTIR senses smoke particulate from Carbon Monoxide (CO), thermal, photo,
and infrared signatures simultaneously to determine the presence of a fire condition.
Sensor readings are continually evaluated against one another, allowing the detector
to operate normally with high immunity to nuisance conditions, while quickly responding
to true alarm events.

ACCLIMATE
The Acclimate detector combines thermal and photoelectric technologies into a single
device. It constantly monitors ambient heat and particulate conditions, adjusting sensitivity parameters and alarm thresholds automatically to maximize detection across a broad
range of fire types.

FAAST
Fire Alarm Aspiration Sensing Technology (FAAST) solutions provide early warning of
an impending fire hazard. FAAST can buy time to investigate an alarm and initiate an
appropriate response to prevent injury, property damage, or business disruption. With
a wide sensitivity range and multi-level warnings, even minute levels of smoke can be
detected before a fire has time to escalate. It is also possible to connect the unit to the
buildings Ethernet connection in order to provide access and monitoring from anywhere
in the world.

ECLIPSE
The EclipseTM family is an innovative line of detection and notification devices, which
boasts a completely digital, powerful and extremely fast protocol. Unmatched in the
industry, this protocol is one of many unique features of the XLS3000 Fire Alarm System.
Other benefits include:
Intelligence in the head via distributed processing; digital protocol for speed, accuracy,
and error detection; peer-to-peer device communication; and adaptable to existing
wiring
Integral Isolators such as loop reliability (short circuit protection, earth fault detection)
Auto addressing; As-wired mapping - cable tree structure; and providing Style 7
operation
Electronic addressing features such as Unique Serial Number; device replacements
can be found and automatically addressed; and eliminates dual addressing

Emergency Communications
and Annunciation
Honeywell fire alarm control panels are paired with a variety of customized and effective visual, audible, and textual/
DRMNS emergency notification products. These products ensure facility occupants are notified of emergencies
and communicate action and direction for the proper response. This aids significantly in the proper accountability
of personnel during potential evacuation.

First Responder
Honeywells First Responder is a revolutionary touch screen graphical interface that simplifies
emergency scene assessment from a building lobby. Emergency responders can immediately
gather the information needed to accurately pinpoint the source of the fire and the rate at which
its spreading, enabling them to quickly locate and extinguish the fire.

Indoor/Outdoor Notification
SpectrAlert Advance is a visual/audible fire and non-fire emergency notification products line.
SpectrAlert Advance line supports indoor and outdoor use, along with different lens colors
for various emergency types.
Plug-in design; bases wire separately
Field-selectable candela settings on wall and ceiling units:
15, 15/75, 30, 75, 95, 110, 115, 145, 150, 177, 185
Captive mounting screw
Tamper resistance capability
Automatic selection of 12-or-24 volt operation at 15 and 15/75 candela
Shorting spring on mounting plate for continuity check before installation
Indoor/Outdoor
Horn/Strobe

Outdoor wall and ceiling products rated from -40F to 151F

Giant Voice
The Whelen Emergency Communication warning system is an omni-directional voice and siren warning system,
installed around an industrial facility to alert occupants and surrounding areas of emergency conditions.
One to ten omni-directional speaker cells assembled in a vertical column
Ten models, 109dBc to 129 dBc @ 100
All WPS2900 speaker cells include high efficiency 400 watt EZ-PULL speaker drivers
Power amplifiers
Tone generator

Textual/DRMNS Notification
Textual and Distributed Recipient Mass Notifications Systems (DRMNS) are a multi-faceted approach that
utilizes an organizations existing IP network as the basis for an emergency notification and communications
system. These systems also allow for specific user groups to be established so that targeted communications can be sent. In addition, they interface with the fire and gas system with relay or high-level interfaces.

Telephone

Cell Phone

Text Messaging

Email

Desktops

LED Displays

XLS120 / XLS140-2 System


XLS140-2
Fire Alarm
Control Panel

EIA-232
SLC
SLC
XLS-120
Fire Alarm
Control Panel

XLS-PRN-6 Printer

TC840M
Acclimate
Detector

TC809A1059
Monitor Module

TC806B
Photo Detector

XLS-NET

TC846A
PINNACLE
Detector

LCD2--80
Remote
Annunciator
TC807B
Ion Detector

FAAST
Aspiration
Detector

TC840C2010
Multi-Criteria
Fire/CO Detector

TC808B
Thermal Detector
TC840C
COPTIR
Detector

DNR
Duct Detector

XLS-NCA2

TC847A
Addressable
Beam Detector
FNA-3
Fire Network Adapter

TC809A
Monitor Module
TC841A
2-Wire Detector
Monitor Module

IP

S464G
Addressable
Manual Pull
Station
Honeywell Enterprise
Building Integrator

2151
Photo Detector

ACPS-610
Addressable
Charger Power Supply

P2RH
Horn/Strobe

Intelligent Devices

Intelligent 1 Loop

Complete intelligent system

Fire Alarm Control Panel

feature set with digital protocol,

318 FlashScanTM devices

9 levels of sensitivity, drift compensa-

(159 detectors and 159 modules)


per loop
Expandable to 2 SLC loops
(XLS140-2 only)
Honeywell Enterprise Buildings
Integrator (EBI) compatible
UL 864, Ninth Edition listed
Supports Honeywell CLIP and
FlashScanTM addressable devices

tion and maintenance alert, and auto


detector test
6.0 amp switch mode power supply
with four Class A/B built-in NAC

2WB
Photo Detector

HR
Horn

SCW
Strobe

Peripheral Devices

Supports Direct Connect to the


XLS-DVC Digital Voice Command
(XLS140-2 only)
XLS-NET compatible up to 102
nodes for standard networking
or 200 nodes for high speed
networking

(Notification Appliance Circuits).

Unique environment detection

Selectable System Sensor strobe

includes Pinnacle for clean

synchronization

environments, COPTIR for critical

Fully field programmable with


80-character display (includes
QWERTY keypad) or offline with
VeriFire Tools programming utility

environments, and Acclimate


a multi sensor that adjusts
sensitivity automatically
Optional universal 2040-point DACT

XLS3000 System
EIA-485

LCD-160
Display

SCS
Smoke
Control Station

Custom
Graphics
Annunciator

ACS
LED Annunciator

UDACT-2 Digital
Alarm
Communicator

EIA-232

SLC Loop
(Up to 10)

XLS-PRN-6 Printer
TC809A
Monitor Module

FAAST
Aspiration
Detector

TC906A
Photo Detector

XLS3000 Fire Alarm


Control Panel
XLS-NET
EA-CT Eclipse
Infrared Tool

XLS-NCA2

FNA-3
Fire Network Adapter

TC807B
Ion Detector

DNR
Duct Detector

TC840C2010
Multi-Criteria
Fire/CO Detector

TC840C
COPTIR
Detector

TC809A
Monitor Module
TC910R
Relay Module

IP

S464G
Addressable
Manual Pull
Station

TC910N
Control Module

Honeywell Enterprise
Building Integrator

P2RH
Horn/Strobe

Intelligent Devices

Intelligent 1 to 10 Loop

Honeywell SMART capable

Fire Alarm Control Panels

250 Eclipse devices (125 detectors

Honeywell Enterprise Buildings

and 125 modules) per loop

Integrator (EBI) compatible

Large 640-character LCD backlit

UL 864, Ninth Edition listed

display (16 lines x 40 characters)

1-10 Signaling Line Circuits

or displayless (a node on a network)

Style 4, 6 or 7
Supports Honeywell CLIP, ECLIPSE,
and FlashScan addressable devices
Point Capacity: Up to 159 detectors

XLS-NET compatible (up to 102 nodes

PF24V
ExitPointTM
with Voice

Peripheral Devices

Weekly Occupancy Schedules allow


changing sensitivity by time of day
and day of week
Optional universal 2040-point DACT
EIA-485 annunciators, including
custom graphics
Unique environment detection includes
Pinnacle for clean environments,

for high-speed networking

COPTIR for critical environments,

Application code is saved in FLASH


memory, eliminating the need

thermal, or multisensor) and 159 modules

to change EPROMs

notification, or relay) per SLC

SCW
Strobe

for standard networking or 200 nodes

(any mix of ion, photo, laser photo,


(N.O. manual stations, two-wire smoke,

HR
Horn

Supports Direct Connect to the


XLS-DVC Digital Voice Command

and Acclimate a multi sensor that


adjusts sensitivity automatically
FM6320 approved Gas Detection
System with TC809C module and
any FM approved gas detector

XLS-DVC Digital Voice Command


Up to 32
Digital Audio
Amplifiers

Background Music,
Paging and Emergency
Communication System
Input

Digital
Audio
Riser

Digital Audio
Amplifier

Low Level
Audio
Channel
Output

Outdoor Voice

Up to 4
Speaker
Circuits

Digital
Audio Loop

Firefighter
Telephone
Circuit

XLS3000 with XLS-DVC-EM


Digital Voice Command

Background Music,
Paging and Emergency
Communication System
Input

AA Series Amplifier

Low Level
Audio Channels
Low Level
Audio
Channel
Output
Outdoor Voice

Eight channels of audio messages


and five channels of fire telephones
over the digital audio loop
Digital audio loop compatible with wire,
single mode and multi-mode fiber
Up to 32 minutes of digital audio
message/tone storage
Up to 1000 audio sequences
Messages are created with standard
.wav files
Digital audio ports for direct connection with up to 32 digital amplifiers.

XLS140-2 with XLS-DVC-EM


Digital Voice Command

Two auxiliary low level audio inputs


Programmable via VeriFire Tools
programming utility
Honeywell Enterprise Buildings
Integrator (EBI) compatible
XLS-NET Compatible
Can provide analog low level audio
output for retrofit applications
Allows for multiple command centers
and expansion up to thousands
of digital amplifiers
Live paging over XLS-NET

TC810N
Control
Module

Speaker

Isolated alarm bus input for fail safe


degraded mode operation.
History buffer for local event storage
Delivers cost effective digital audio
through traditional analog amplifiers
Interface with giant voice system
for outdoor applications

SMARTTM

Panel Comparison
XLS-120

XLS140-2

XLS3000

SLC Protocol Capability


Maximum number of SLCs
Honeywell CLIP Capable
Honeywell FlashScanTM Capable
Honeywell EclipseTM Capable
SLC Autoprogram

1
Yes
Yes
No
Yes

2
Yes
Yes
No
Yes

10
Yes
Yes
Yes
Yes

EBI & Networking Compatibility


XLS-NET Compatible
Full EBI Integration

Yes
Yes

Yes
Yes

Yes
Yes

Audio Capability
Standalone Audio w/Analog Amplifiers
Standalone Audio w/Digital Amplifiers
Networked Digital Audio Capable

No
No
No

Yes
Yes
Yes

Yes
Yes
Yes

Programming Options
SMARTTM Capable
Logic Zones
Releasing Zones

No
99
10

No
99
10

Yes
1000
10

200 AH

200 AH

200 AH

Yes
No
No
80 Char.

Yes
Yes
Yes
80 char.

No
Yes
Yes
640 char.

Yes
Yes
Yes
Yes
Yes
No

Yes
Yes
Yes
Yes
Yes
No

Yes
Yes
Yes
Yes
Yes
Yes

Main Power Supply Battery Capacity


Display Options
80 Character
640 Character
Displayless
Remote LCD Annunciator
Regulatory Approvals
UL 9th Edition
ULC
FM
MEA
CSFM
City of Chicago

Properly maintaining a fire alarm system


is critical to ensure that it will work when
it is needed the most. The problem with
the average fire alarm system is that it
does little more than tell you when it has
already been compromised. Only the
Honeywell XLS3000 offers the patented
(US 7,161,481 B2) System Maintenance
Analysis Reporting Tool (SMARTTM),
which provides an unparalleled amount
of service and maintenance information
to the owner. SMARTTM is Honeywell
technology to track the required installation, inspection, testing and maintenance
frequencies of your Fire Alarm System.
SMARTTM is a software algorithm in
XLS3000 that:
Knows local (regional) testing
requirements
Verifies all system points are tested
at installation
Tracks periodic testing
Reports devices that require testing
and those coming due for service
Verifies that changes to the system
are tested, speeding recertification
Alerts building owner when testing
is required
Independently verifies to the owner
that service is being performed
SMARTTM is Honeywells way to deliver:
Piece of Mind for the Building Owner
- That the fire alarm system is
operating normally
- That the service company
is performing their work
- That interruptions to the building
activities are minimized
- That their investment is being
optimally protected
Code Compliance for:
- Fire Marshall
- Building Inspector
- On-site Safety Personnel
SMARTTM is one of many key advantages
of the Honeywell XLS3000 Fire Alarm
System when used with its revolutionary
EclipseTM family of detectors and modules.

More Information
For more information about
Honeywell Building Solutions, call
1-800-345-6770, ext. 603. Or e-mail
[email protected]
Honeywell Building Solutions
Honeywell International Inc.
1985 Douglas Drive North
Golden Valley, MN 55422-3992
Tel: 1-800-345-6770, ext. 603
Outside North America:
+1-480-592-3248
www.honeywell.com

SL 53-2006-1
June 2012
Printed in U.S.A.
2012 Honeywell International Inc.

You might also like