Device Information
Part Number 0487E32648XXC2X4H624XXX
FID
SEL-487E-3-RXXX-V0-Z103101-D20121108
BFID
SLBT-4XX-R205-V0-Z001002-D20100128
Config
Special
Displayed Setting Groups
Global
Group 1
Settings Legend
Visible Setting
Hidden Setting
Invalid Setting
file:///C:/Users/pbanerjee/AppData/Roaming/SEL/AcSELerator/QuickSet/Session_00... 19-03-2015
Page 2 of 9
Global
Top
Value
Setting
Description
Range
SID
Station Identifier
Range = ASCII string with a
maximum length of 40.
HADCO
RID
Relay Identifier
Range = ASCII string with a
maximum length of 40.
SGT
NFREQ
Nominal System Frequency
Select: 50, 60
60
PHROT
System Phase Rotation
Select: ABC, ACB
ABC
EICIS
Enable Independent Control
Input Settings
Select: Y, N
EPMU
Enable Synchronized Phasor
Select: Y, N
Measurements
IN1XXD
Debounce Time For
Mainboard Contact Inputs
Range = 0.0 to 30.0
2.0
IN2XXD
Debounce Time For Interface
Range = 0.0 to 30.0
Board # 1 Contact Inputs
2.0
SS1
Condition(s) to Enable
Setting Group 1 Equation
Valid range = The legal
operators: AND OR NOT
R_TRIG F_TRIG
SS2
Condition(s) to Enable
Setting Group 2 Equation
Valid range = The legal
operators: AND OR NOT
R_TRIG F_TRIG
NA
SS3
Condition(s) to Enable
Setting Group 3 Equation
Valid range = The legal
operators: AND OR NOT
R_TRIG F_TRIG
NA
SS4
Condition(s) to Enable
Setting Group 4 Equation
Valid range = The legal
operators: AND OR NOT
R_TRIG F_TRIG
NA
SS5
Condition(s) to Enable
Setting Group 5 Equation
Valid range = The legal
operators: AND OR NOT
R_TRIG F_TRIG
NA
SS6
Condition(s) to Enable
Setting Group 6 Equation
Valid range = The legal
operators: AND OR NOT
R_TRIG F_TRIG
NA
TGR
Group Change Delay
Range = 1 to 54000
180
FRQST
Primary Frequency Source
Terminal
Select: V, Z, ADV or OFF
DATE_F
Date Format
Select: MDY, YMD, DMY
MDY
IRIGC
IRIG-B Control Bits
Definition
Select: NONE, C37.118
NONE
UTCOFF
Offset From UTC to Local
Time
Range = -15.5 to 15.5
-8.0
BEG_DST Begin DST
Select:
"0,1,2,3,4,5,6,7,8,9,10,11,12,13,14,15,16,17,18,19,20,21,22,23",
2, 2, 1, 3
"1,2,3,L", "1,2,3,4,5,6,7",
"1,2,3,4,5,6,7,8,9,10,11,12"
END_DST End DST
Select:
"0,1,2,3,4,5,6,7,8,9,10,11,12,13,14,15,16,17,18,19,20,21,22,23",
2, 1, 1, 11
"1,2,3,L", "1,2,3,4,5,6,7",
"1,2,3,4,5,6,7,8,9,10,11,12"
Condition(s) for Resetting of Valid range = The legal
operators: AND OR NOT
RST_DEM Demand Metering Data
R_TRIG F_TRIG
Equation
NA
Condition(s) for Resetting of Valid range = The legal
file:///C:/Users/pbanerjee/AppData/Roaming/SEL/AcSELerator/QuickSet/Session_00... 19-03-2015
Page 3 of 9
RST_PDM
Peak Demand Metering Data operators: AND OR NOT
Equation
R_TRIG F_TRIG
NA
RST_ENE
Condition(s) for Resetting of Valid range = The legal
Energy Metering Data
operators: AND OR NOT
Equation
R_TRIG F_TRIG
NA
RSTTRGT
Valid range = The legal
Condition(s) for Resetting of
operators: AND OR NOT
Target LEDs Equation
R_TRIG F_TRIG
NA
Condition(s) for Resetting of Valid range = The legal
RSTDNPE DNP Fault Summary Data
operators: AND OR NOT
Equation
R_TRIG F_TRIG
TRGTR
Condition(s) for Resetting of Valid range = The legal
RST_HAL Warning Alarm Pulsing
operators: AND OR NOT
Equation
R_TRIG F_TRIG
NA
EVELOCK Event Summary Lock Period Range = 0 to 1000
DNPSRC
UTC
DNP Session Time Base
Select: LOCAL, UTC
Global
Top
file:///C:/Users/pbanerjee/AppData/Roaming/SEL/AcSELerator/QuickSet/Session_00... 19-03-2015
Page 4 of 9
Group 1
Top
Setting
Description
Range
Value
ECTTERM
Enable the Following Current Terminals
Select: Combination of S,
T, U, W, X or OFF
S, T
EPTTERM
Enable the Following Voltage Terminals
Select: Combination of V,
Z or OFF
E87
Include the Following Terminals in the Differential
Element
Select: Combination of S, T
S, T
or OFF
EREF
Enable the Following Number of Restricted Earth Fault
Elements
Select: N, 1-3
E50
Enable Definite Time Overcurrent Elements for the
Following Terminals
Select: Combination of S, T
S, T
or OFF
E51
Enable the Following Number of Inverse Time
Overcurrent Elements
Select: N, 1-10
E46
Enable Current Unbalance Elements for the Following
Terminals
Select: Combination of S, T
OFF
or OFF
E59
Enable the Following Number of Overvoltage Elements
Select: N, 1-5
E27
Enable the Following Number of Undervoltage Elements Select: N, 1-5
E81
Enable the Following Number of Over/Under Frequency
Elements
Select: N, 1-6
E24
Enable Volts per Hertz Protection
Select: N, Y
EBFL
Enable Breaker Failure Protection for the Following
Terminals
Select: Combination of S, T
T
or OFF
EPCAL
Enable Active, Reactive and Apparent Power
Calculations for the Following Terminals
Select: Combination of S, T
OFF
or OFF
EDEM
Select the Number of Demand Metering Elements
Required
Select: N, 1-10
PTRV
Potential Transformer Ratio for Terminal V
Range = 1.0 to 10000.0
2000.0
PTCONV
Potential Transformer Connection For Terminal V
Select: Y, D
PTCOMPV
Potential Transformer Compensation Angle for Terminal
Range = -179.99 to 180.00
V
0.00
VNOMV
Potential Transformer Nominal Line-to-Line Voltage For
Range = 30 to 300
Terminal V
110
CTRS
Current Transformer Ratio For Terminal S
Range = 1 to 50000
400
CTCONS
Current Transformer Connection For Terminal S
Select: Y, D
CTRT
Current Transformer Ratio For Terminal T
Range = 1 to 50000
2400
CTCONT
Current Transformer Connection For Terminal T
Select: Y, D
CTRY1
Current Transformer Ratio for Terminal Y, Channel 1
Range = 1 to 50000
100
VREFS
Select Voltage Reference for Terminal S
Select: OFF, V
VREFT
Select Voltage Reference for Terminal T
Select: OFF, V
OFF
ICOM
Internal CT Connection Matrix Compensation Enabled
Select: Y, N
MVA
Enter Transformer Maximum MVA Rating
Range = 1 to 5000, OFF
120
E87TS
Include Terminal S in the Differential Element for the
Following Conditions
Valid range = The legal
operators: AND OR NOT
R_TRIG F_TRIG
TSCTC
Terminal S CT Connection Compensation
Range = 0 to 12
12
VTERMS
Terminal S Line-to-Line Voltage
Range = 1.00 to 1000.00
380.00
E87TT
Include Terminal T in the Differential Element for the
Following Conditions
Valid range = The legal
operators: AND OR NOT
R_TRIG F_TRIG
file:///C:/Users/pbanerjee/AppData/Roaming/SEL/AcSELerator/QuickSet/Session_00... 19-03-2015
Page 5 of 9
TTCTC
Terminal T CT Connection Compensation
Range = 0 to 12
12
VTERMT
Terminal T Line-to-Line Voltage
Range = 1.00 to 1000.00
33.00
O87P
Differential Element Operating Current Pickup
Range = 0.10 to 4.00
0.25
SLP1
Slope 1 Setting
Range = 5.00 to 90.00
33.00
SLP2
Slope 2 Setting
Range = 5.00 to 90.00
90.00
U87P
Unrestrained Element Current Pickup
Range = 1.00 to 20.00
8.00
DIOPR
Incremental Operate Current Pickup
Range = 0.10 to 10.00
1.20
DIRTR
Incremental Restraint Current Pickup
Range = 0.10 to 10.00
1.20
E87HB
Enable Harmonic Blocking Differential Element
Select: Y, N
E87HR
Enable Harmonic Restraint Differential Element
Select: Y, N
PCT2
Second-Harmonic Percentage (% of fundamental)
Range = 5 to 100, OFF
15
PCT4
Fourth-Harmonic Percentage (% of fundamental)
Range = 5 to 100, OFF
15
PCT5
Fifth-Harmonic Percentage (% of fundamental)
Range = 5 to 100, OFF
50
TH5P
Fifth-Harmonic Alarm Threshold
Range = 0.2 to 3.2, OFF
OFF
87QP
Negative Sequence Differential Element Operating
Current Pickup
Range = 0.05 to 1.00
0.30
SLPQ1
Negative Sequence Differential Slope
Range = 5 to 100
25
87QD
Negative Sequence Differential Element Delay
Range = 2.000 to 9999.000 10.000
REFRF1
Select the Restraint Quantity for REF Element 1
Select: Combination of S, T
OFF
or OFF
REF50P1
REF (50P) Operate Current Instantaneous Overcurrent 1
Pickup
Range = 0.05 to 20.00, OFF OFF
REF51P1
REF (51P) Operate Current Inverse Time Overcurrent
Element 1 Pickup
Range = 0.05 to 3.20, OFF
0.05
REF51C1
REF Inverse Time Overcurrent Element 1 Curve
Select: U1-U5, C1-C5
C4
RF51TD1
REF Inverse Time Overcurrent Element 1 Time Dial
Setting
Range = 0.05 to 1.00
0.15
RF51RS1
REF Inverse Time Overcurrent Element 1
Electromechanical Reset
Select: Y, N
RF51TC1
Valid range = The legal
REF Inverse Time Overcurrent Element 1 Torque Control
operators: AND OR NOT
Equation
R_TRIG F_TRIG
E50S
Enable the Type of Overcurrent Elements for Terminal S
Select: Combination of P,
Q, G
P, G
N
E67S
Enable Directional Elements
Select: Y, N
50SP1P
Phase Instantaneous Overcurrent Pickup Level 1
Range = 0.05 to 20.00, OFF 8.00
67SP1TC
Valid range = The legal
Phase Instantaneous Overcurrent Level 1 Torque Control operators: AND OR NOT
R_TRIG F_TRIG
SF32P AND
PLT03
67SP1D
Phase Instantaneous Overcurrent Level 1 Delay
Range = 0.00 to 16000.00
3.00
50SG1P
Zero-Seq Inst O/C Pickup Level 1
Range = 0.05 to 20.00, OFF OFF
50SP2P
Phase Instantaneous Overcurrent Pickup Level 2
Range = 0.05 to 20.00, OFF OFF
E50T
Select: Combination of P,
Enable the Type of Overcurrent Elements for Terminal T
Q, G
50TP1P
Phase Instantaneous Overcurrent Pickup Level 1
67TP1TC
Valid range = The legal
Phase Instantaneous Overcurrent Level 1 Torque Control operators: AND OR NOT
R_TRIG F_TRIG
TF32P AND
PLT03
67TP1D
Phase Instantaneous Overcurrent Level 1 Delay
Range = 0.00 to 16000.00
3.00
50TG1P
Zero-Seq Inst O/C Pickup Level 1
Range = 0.05 to 20.00, OFF OFF
50TP2P
Phase Instantaneous Overcurrent Pickup Level 2
Range = 0.05 to 20.00, OFF OFF
EXBFT
Enabling Condition(s) for External Breaker Failure
Valid range = The legal
operators: AND OR NOT
P, G
Range = 0.05 to 20.00, OFF 9.00
NA
file:///C:/Users/pbanerjee/AppData/Roaming/SEL/AcSELerator/QuickSet/Session_00... 19-03-2015
Page 6 of 9
R_TRIG F_TRIG
EBFPUT
External Breaker Failure Initiate Pickup Delay
Range = 0.000 to 6000.000 6.000
50FPUT
Fault Current Pickup
Range = 0.10 to 10.00
BFPUT
Breaker Failure Initiate Pickup Delay
Range = 0.000 to 6000.000 12.000
RTPUT
Retrip Delay
Range = 0.000 to 6000.000 6000.000
BFIT
Breaker Fail Initiate Condition(s)
Valid range = The legal
operators: AND OR NOT
R_TRIG F_TRIG
NA
ATBFIT
Alternate Breaker Fail Initiate Condition(s)
Valid range = The legal
operators: AND OR NOT
R_TRIG F_TRIG
NA
ENINBFT
Enabling Condition(s) for Neutral Breaker Failure
Valid range = The legal
operators: AND OR NOT
R_TRIG F_TRIG
NA
INFPUT
Neutral Current Pickup
Range = 0.10 to 10.00
0.10
EBFIST
Breaker Failure Initiate Seal-In
Select: Y, N
BFIDOT
Breaker Failure Initiate Dropout Delay
Range = 0.000 to 1000.000 1.500
51O01
Inverse Time Overcurrent Element 01 Operate Quantity
Select: 3I0TM, 3I2TM,
I1TM, IATFM, IATRMS,
IBTFM, IBTRMS, ICTFM,
ICTRMS, IMAXTF,
IMAXSF
IMAXTR, 3I0SM, 3I2SM,
I1SM, IASFM, IASRMS,
IBSFM, IBSRMS, ICSFM,
ICSR ...
51P01
Inverse Time Overcurrent Element 01 Pickup Value
Valid range = The legal
operators: AND OR NOT
R_TRIG F_TRIG
0.6
51C01
Inverse Time Overcurrent Element 01 Curve Selection
Select: U1-U5, C1-C5
C1
51TD01
Inverse Time Overcurrent Element 01 Time Dial
Valid range = The legal
operators: AND OR NOT
R_TRIG F_TRIG
0.20
51RS01
Inverse Time Overcurrent Element 01 Electromechanical
Select: Y, N
Reset Enable
51TC01
Inverse Time Overcurrent Element 01 Torque Control
Valid range = The legal
operators: AND OR NOT
R_TRIG F_TRIG
51O02
Inverse Time Overcurrent Element 02 Operate Quantity
Select: 3I0TM, 3I2TM,
I1TM, IATFM, IATRMS,
IBTFM, IBTRMS, ICTFM,
ICTRMS, IMAXTF,
IMAXTF
IMAXTR, 3I0SM, 3I2SM,
I1SM, IASFM, IASRMS,
IBSFM, IBSRMS, ICSFM,
ICSR ...
51P02
Inverse Time Overcurrent Element 02 Pickup Value
Valid range = The legal
operators: AND OR NOT
R_TRIG F_TRIG
1.1
51C02
Inverse Time Overcurrent Element 02 Curve Selection
Select: U1-U5, C1-C5
C1
51TD02
Inverse Time Overcurrent Element 02 Time Dial
Valid range = The legal
operators: AND OR NOT
R_TRIG F_TRIG
0.20
51RS02
Inverse Time Overcurrent Element 02 Electromechanical
Select: Y, N
Reset Enable
51TC02
Inverse Time Overcurrent Element 02 Torque Control
Valid range = The legal
operators: AND OR NOT
R_TRIG F_TRIG
9.00
Y
PLT09
Y
PLT09
Select: 3I0TM, 3I2TM,
file:///C:/Users/pbanerjee/AppData/Roaming/SEL/AcSELerator/QuickSet/Session_00... 19-03-2015
Page 7 of 9
51O03
Inverse Time Overcurrent Element 03 Operate Quantity
I1TM, IATFM, IATRMS,
IBTFM, IBTRMS, ICTFM,
ICTRMS, IMAXTF,
IMAXTR, 3I0SM, 3I2SM, 3I0SM
I1SM, IASFM, IASRMS,
IBSFM, IBSRMS, ICSFM,
ICSR ...
51P03
Inverse Time Overcurrent Element 03 Pickup Value
Valid range = The legal
operators: AND OR NOT
R_TRIG F_TRIG
0.6
51C03
Inverse Time Overcurrent Element 03 Curve Selection
Select: U1-U5, C1-C5
C1
51TD03
Inverse Time Overcurrent Element 03 Time Dial
Valid range = The legal
operators: AND OR NOT
R_TRIG F_TRIG
0.15
51RS03
Inverse Time Overcurrent Element 03 Electromechanical
Select: Y, N
Reset Enable
51TC03
Inverse Time Overcurrent Element 03 Torque Control
Valid range = The legal
operators: AND OR NOT
R_TRIG F_TRIG
51O04
Inverse Time Overcurrent Element 04 Operate Quantity
Select: 3I0TM, 3I2TM,
I1TM, IATFM, IATRMS,
IBTFM, IBTRMS, ICTFM,
ICTRMS, IMAXTF,
3I0TM
IMAXTR, 3I0SM, 3I2SM,
I1SM, IASFM, IASRMS,
IBSFM, IBSRMS, ICSFM,
ICSR ...
51P04
Inverse Time Overcurrent Element 04 Pickup Value
Valid range = The legal
operators: AND OR NOT
R_TRIG F_TRIG
0.1
51C04
Inverse Time Overcurrent Element 04 Curve Selection
Select: U1-U5, C1-C5
C1
51TD04
Inverse Time Overcurrent Element 04 Time Dial
Valid range = The legal
operators: AND OR NOT
R_TRIG F_TRIG
0.20
51RS04
Inverse Time Overcurrent Element 04 Electromechanical
Select: Y, N
Reset Enable
51TC04
Inverse Time Overcurrent Element 04 Torque Control
Valid range = The legal
operators: AND OR NOT
R_TRIG F_TRIG
PLT09
TRXFMR
Trip Condition(s) for Transformer Terminals
Valid range = The legal
operators: AND OR NOT
R_TRIG F_TRIG
87R OR REFF1
ULTXFMR
Unlatch Trip Condition(s) for Transformer Terminals
Valid range = The legal
operators: AND OR NOT
R_TRIG F_TRIG
TRGTR
TRS
Trip Condition(s) for Terminal S
Valid range = The legal
operators: AND OR NOT
R_TRIG F_TRIG
50SP1 OR 50SQ1
ULTRS
Unlatch Trip Condition(s) for Terminal S
Valid range = The legal
operators: AND OR NOT
R_TRIG F_TRIG
TRGTR
CLS
Close Condition(s) for Terminal S
Valid range = The legal
operators: AND OR NOT
R_TRIG F_TRIG
LB10
ULCLS
Unlatch Close Condition(s) for Terminal S
Valid range = The legal
operators: AND OR NOT
R_TRIG F_TRIG
52CLS
TRT
Trip Condition(s) for Terminal T
Valid range = The legal
operators: AND OR NOT
R_TRIG F_TRIG
50TP1 OR 50TQ1
Y
PLT09
file:///C:/Users/pbanerjee/AppData/Roaming/SEL/AcSELerator/QuickSet/Session_00... 19-03-2015
Page 8 of 9
ULTRT
Unlatch Trip Condition(s) for Terminal T
Valid range = The legal
operators: AND OR NOT
R_TRIG F_TRIG
TRGTR
CLT
Close Condition(s) for Terminal T
Valid range = The legal
operators: AND OR NOT
R_TRIG F_TRIG
LB10
ULCLT
Unlatch Close Condition(s) for Terminal T
Valid range = The legal
operators: AND OR NOT
R_TRIG F_TRIG
52CLT
TDURD
Minimum Trip Duration
Range = 2.000 to 8000.000 5.000
ER
Condition(s) for Triggering Event Reports
Valid range = The legal
operators: AND OR NOT
R_TRIG F_TRIG
50SQ1 OR 50TQ1
FAULT
Condition(s) for Asserting Fault Bit
Valid range = The legal
operators: AND OR NOT
R_TRIG F_TRIG
50SQ1 OR 50TQ1
CFD
Close Failure Delay
Range = 2.000 to
99999.000, OFF
4.000
24VSRC
Voltage Source for V/Hz Calculation
Select: V, Z
24D1P
Level 1 Volts/Hertz Pickup (%)
Range = 100 to 200
110
24D1D
Level 1 Time Delay
Range = 0.04 to 6000.00
10.00
24TC
Torque Control for Volts/Hertz Element
Valid range = The legal
operators: AND OR NOT
R_TRIG F_TRIG
24CCS
Select Level 2 Composite Curve
Select: OFF, DD, U1, U2
U1
24U1TC
Torque Control for Curve 1
Valid range = The legal
operators: AND OR NOT
R_TRIG F_TRIG
24U1NP
Select the Number of Points for Curve 1
Range = 3 to 20
24U1CR
Curve 1 Reset Time (seconds)
Range = 0.01 to 400.00
400.00
24U111
Curve 1, Point 01
Range = 100 to 200
110
24U121
Curve 1, Point 01
Range = 0.04 to 6000.00
6000.00
24U112
Curve 1, Point 02
Range = 100 to 200
115
24U122
Curve 1, Point 02
Range = 0.04 to 6000.00
240.00
24U113
Curve 1, Point 03
Range = 100 to 200
120
24U123
Curve 1, Point 03
Range = 0.04 to 6000.00
60.00
24U114
Curve 1, Point 04
Range = 100 to 200
125
24U124
Curve 1, Point 04
Range = 0.04 to 6000.00
30.00
24U115
Curve 1, Point 05
Range = 100 to 200
130
24U125
Curve 1, Point 05
Range = 0.04 to 6000.00
19.00
24U116
Curve 1, Point 06
Range = 100 to 200
135
24U126
Curve 1, Point 06
Range = 0.04 to 6000.00
13.00
24U117
Curve 1, Point 07
Range = 100 to 200
140
24U127
Curve 1, Point 07
Range = 0.04 to 6000.00
10.00