The Dynacalibrator Model 190 is a calibration gas generator that can produce precise gas concentrations from ppb to high ppm levels for calibrating analytical instruments. It uses permeation devices to generate calibration standards for a wide range of compounds. Key advantages over bottled gas standards include lower overall costs, the ability to easily generate multi-component mixtures, and the avoidance of degradation issues associated with bottled standards. The Dynacalibrator features include temperature control from 5C above ambient to 110C, digital readout and control of the permeation chamber temperature, and fittings for gas inlet and outlet tubing.

Uploaded by

l0k0tus
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
175 views2 pages

Dyna 190

The Dynacalibrator Model 190 is a calibration gas generator that can produce precise gas concentrations from ppb to high ppm levels for calibrating analytical instruments. It uses permeation devices to generate calibration standards for a wide range of compounds. Key advantages over bottled gas standards include lower overall costs, the ability to easily generate multi-component mixtures, and the avoidance of degradation issues associated with bottled standards. The Dynacalibrator features include temperature control from 5C above ambient to 110C, digital readout and control of the permeation chamber temperature, and fittings for gas inlet and outlet tubing.

Uploaded by

l0k0tus
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 2

Analytical

Index
Next

Components
Systems

VICI Metronics Inc.

&

Back
Calibrators

Dynacalibrator Model 190


Calibration Gas Generator
PPB to high PPM range
Precise temperature control to 110C
Economical, flexible alternative to
bulky bottled mixtures

Description

Advantages Over Bottled Standards

Metronics Dynacalibrators enable calibrations traceable


to NIST standards for almost any gas analyzer, in the lab
or in the field. They are ideal for verifying the accuracy of
analytical data from air pollution monitoring, industrial
hygiene surveys, odor survey programs, and other
instruments measuring gas concentration.

Calibration devices from VICI


Metronics offer several
key advantages over
cylinder-supplied gas
calibration standards.

The design takes full advantage of all the conveniences


inherent in our Dynacal permeation devices to generate
and deliver precise concentrations ranging from ppb to
high ppm for hundreds of different compounds. Standard
features include front panel permeation chamber access,
a solid state proportional temperature controller, digital
readout for set point and chamber temperature, stainless
steel inlet and Teflon outlet, (1/8" tube fittings), and a
cooling fan.

OUTLET

INLET

DIGITAL
TEMPERATURE
CONTROLLER
PANEL

055

PERMEATION
CHAMBER

Economy is always a
major consideration;
customers who have
done the arithmetic, factoring in the cost of cylinder
purchase, shipment, and
disposal, typically discover that the purchase of a
Dynacalibrator and a supply of permeation devices will
start to save them money in the second year of use.
Multicomponent mixtures can be easily generated with a
Dynacalibrator and the appropriate combination of
permeation devices. This technique also allows the removal
of a single component from a gas mixture by simply
removing the appropriate permeation device. Alternative
methods require expensive custom mixtures or a large
number of gas cylinders, which consume valuable lab
space as well.
Bottled standards can also have problems arising from
degradation of the standard within the cylinder, from
changes in the concentration levels as the cylinder pressure
changes, and from interaction of calibration components
and surfaces.

Specifications
Index
Next
Back

Permeation chamber

Calibrators

Permeation device
Maximum total length
Maximum diameter

Pyrex (standard)
.85" ID x 9.4" (2.1 cm x 24 cm)
Teflon (Option P)
.69" ID x 9.4" (1.8 cm x 24 cm)
Stainless steel (Option H)
.875" ID x 9.25" (2.2 cm x 23.5 cm)
23.5 cm (9.25")
1.6 cm (0.62")

Temperature controller

Controls chamber temperature at a set point with


an accuracy of 0.1C (30C - 50C) or 0.2C
(50C - 110C)

Temperature control range

5C above ambient to 110C

Output pressure

0 - 5 psi standard; 50 psi optional (Option H)

Flow capacity

Recommended range of 200 - 1200 ml/min


for carrier flow

Dimensions

10.6" wide x 14.5" deep x 9" high


(26.9 cm x 36.8 cm x 22.9 cm)

Weight

21.4 lbs. (9.7 kg)

Accessories

Power cord for 110 VAC power source


(220 VAC w/option C)
Forceps for removing and inserting permeation devices

Options

Option C
220 VAC
Option H
High pressure stainless steel chamber
Option O
Overflow option with activated charcoal
scrubber and 5 psi poppit valve
Option V
Flow control option with
micrometering needle valve

Metronics Inc.

VICI AG International

tel: 360 697-9199


fax: 360 697-6682
[email protected]

tel: Int + 41 41 925-6200


fax: Int + 41 41 925-6201
[email protected]

Teflon is a registered trademark of E.I. duPont de Nemours. Pyrex is a registered trademark of Corning Glass.
VICI is a registered trademark of Valco Instruments Co. Inc. and VICI AG. Dynacalibrator and Dynacal are registered trademarks of VICI Metronics, Inc.

US customers
call toll-free
(877) 737-1887
8/00