Rev A
3G Concepts Slot & Frame Synchronization
New
10 ms Frame
10 ms Frame
For Slot Synchronization
Primary SCH
For Frame Synchronization
Secondary SCH
Slot & Frame Synchronization plays a VERY important role in 3G-WHY
Used to Search for Cells ( Cell Search )
1. During UE switch on to Obtain the Serving Cell
2. During Idle mode to find better cells to camp on
3. During Active Mode to find soft/softer handover candidates
SCH
BCH
256 Chips
2304 Chips
P-SCH
Broadcast Data (18 bits)
S-SCH
10
11
12
13
14
15
1 Frame = 15 slots = 10 mSec
Pg 1
5-Dec-03
Vijitor Managey
Rev A
New
3G Concepts Slot & Frame Synchronization
The P-SCH is sent on a predefined code and once the UE finds this code, it
has achieved SLOT SYNCHRONOZATION
(the UE now knows when is the start of each time slot!!)
- Since the UE knows when Each timeslot starts, it can extract the S-SCH code
- IF a combination of 15 of these S-SCH group is one of the 64 code groups, The UE
is said to have achieved Frame Synchronization
( remember! there are 64 code groups, each with 8 Primary Scrambling Codes!!)
- With the the known code group, the UE can will only need to try 8 Primary Scrambling
codes onto the CPICH channel to Find the MATCH
(the UE Now knows the Primary Scrambling code of this Cell!!)
During power on, the UE will do the above the identify the best cell to camp onto.
During the Idle mode, the UE will do the above to look for good candidates for cell reselection
During Dedicated mode, the UE will do the above to look for good candidates for handover
Pg 2
5-Dec-03
Vijitor Managey
Slot Synchronization
Rev A
New
10 mSec Frame (15 slots)
PSCh
[1]
BCH
Data
PSCh
[2]
BCH
Data
PSCh
[3]
BCH
Data
PSCh
[4]
BCH
Data
PSCh
[15]
BCH
Data
P-CCPCH
(P-SCH)
Matched Filter
(Matched to P-SCH)
Matched
Filter
Output
time
Pg 3
5-Dec-03
Vijitor Managey
Frame Synchronization
Rev A
New
10 mSec Frame (15 slots)
S-SCH
[1]
S-SCH
[1]
BCH
Data
S-SCH
[2]
S-SCH
[2]
S-SCH
[3]
S-SCH
[4]
BCH
Data
S-SCH
[5]
S-SCH
[3]
S-SCH
[6]
BCH
Data
S-SCH
[7]
S-SCH
[8]
S-SCH
[4]
S-SCH
[9]
BCH
Data
S-SCH
[10]
S-SCH
[15]
S-SCH
[11]
S-SCH
[12]
S-SCH
[13]
S-SCH
[14]
BCH
Data
S-SCH
[15]
P-CCPCH
(S-SCH)
Matched Filter
Matched
Filter
Output
Matched to S-SCH
group pattern
time
Pg 4
5-Dec-03
Vijitor Managey
Rev A
New
3G Concepts Slot & Frame Synchronization
1. What if there are 2 or more cells whose P-SCH/S-SCH arrives at the UE at the same time??
We will look at the issue later but WHAT DO YOU THINK?
2. Primary Scrambling Code planning has derived some techniques due the way the
UE does the CELL SEARCH- Any Ideas?
Pg 5
5-Dec-03
Vijitor Managey
Rev A new
Handover problem due to same P-SCH/S-SCH timing
We discussed about Slot/Frame Synchronization and how the UE does this
inorder to search for cell for it to handover to.
Cell c
SCH
+-4
Cell a
1. UE is on dedicate mode with Cella
SCH
time
Cell b
Soft ho region
With Cells a,b,c
2. The P-SCH/S-SCH of Cellc and Cellb arrives in the mobile at
a. +-4chips difference
b. Approx. similar Ec/No
3. UE tries to Frame Synchronize to Cell b & Cell c BUT cannot
Since cell a and cell b have about the same Ec/No, it would be
difficult to identify the code group of each cell
4. Therefore the UE cannot detect the Cell b & Cell c and hence does not send a Measurement Report
to add any of these cells into the Active Set
these cells will now act as interferers!!
if we are driving, then there is not much of a problem as we can move out of the
problem area fast as
a. Cell as Ec/No and Cell bs Ec/No will be much higher or much
lower
b. one chip difference corresponds to about 70m. Therefore, the UE has
to move at most 4 chips or 280m away from cell a or b
Pg 6
5-Dec-03
Vijitor Managey
Handover problem due to same P-SCH/S-SCH timing
Rev A new
5. This is not really a problem for different sites as
both sites have different timing(not SYNC!!) I.e. the SCH starts
transmitting at different times from the RBS
unless you can find a location where the signal is
about the same AND the SCH reached with +-4 chipsCell a
very remote chance for this actually!!
Cell c
SCH
+-4
SCH
time
Cell b
Soft ho region
With Cells a,b,c
6. This issue is mainly for sectors with one site as all these sectors
are synchronized i.e. the SCH is send at the same time for all 3
sectors within the same site!!
For this, we can use the parameter TCELL to offset
the timing. Say sector 1:Tcell = 1, Sector2:Tcell=2,
Sector3:Tcell = 3
each unit of TCELL = 256chips
7.
Pg 7
It is not easy to detect this kind of problems unless you are
stationary/moving slowly and
the interference level in high coming from these
cells(higher traffic) or there is already a severe pilot
pollution here
(I.e. without the soft handover gain, the UE is more
susceptible interference!!)
5-Dec-03
Vijitor Managey
Rev A new
Detecting Cell with same SCH timing
TIW scanner has the feature SCH timeslot scanner Window
We can do a drive test with this window on and observe any timing issues!!
These 2 cells are not a problem as
a. chip difference In > 4chips
b. Different Ec/No values
-2
-3
Time diff 1-2 = chip diff between strongest
SCH and 2nd Strongest
Time diff 2-3 = chip diff 2nd strongest
SCH and 3rd Strongest
Pg 8
5-Dec-03
Vijitor Managey