PIEZO
MODEL:
ULTRASONIC
SENSOR
SPECIFICATIONS
T/R40-14.4A0-01
ELECTRICAL
SPECIFICATION:
Center frequency(KHz)
401.0KHz
Echo Sensitivity
Decay Time
200mV
(FIG1 SIMULATION TEST CIRCUIT)
1.2ms
(FIG1 SIMULATION TEST CIRCUIT)
Directivity (deg)
7015
Capacitance (pF)
Allowable Maximum Input
Voltage(Vp-p)
Mean Time To Failure
Operating Temperature()
Storage temperature()
180015%
4
5
6
7
8
9
APPEARANCE
140(40KHz) Pulse width 0.5ms, interval 20ms
50000h
-40+80
-40+85
AND DIMENSIONS
9.00.3
2-0.60.05
D R A W I N G N O . T C 0 8 2 0 9
5.00.5
12.50.3
14.40.3
2.00.2
11.01.0
8.01.0
R E V . A 1
AUDIOWELL ELECTRONICSGUANGZHOUCO.LTD
http://www.audiowell.com
P A G E 2/6
SIMULATION TEST CIRCUIT
FIG.1
DIRECTIVITY TEST
FIG. 2
D R A W I N G N O . T C 0 8 2 0 9
R E V . A 1
AUDIOWELL ELECTRONICSGUANGZHOUCO.LTD
http://www.audiowell.com
P A G E 3/6
ENVIRONMENT CHARACTERISTICS
CONDITIONS
STANDARDS
High and low temperature
(from-40 to +80 at a relative humidity of 30%)
Sensitivity shall not change by more than
30% all of the conditions.
Humidity of 10% to 90%
at the temperature of 25
Storage at +85 for 96 hours and at -40 for 96hours
followed by a normalization period at 25. As shown in
FIG.3.
Operation at 95% relative humidity and 40 for 100
hours, followed by a normalization period of 24hours at 30%
and 25.As shown in FIG.4.
All sensitivity shall be within 30% of the
specified values after the device is subjected to
any or all of the conditions.
Vibration at 10Hz to 55Hz ,1.5mm amplitude. 1 minute
sweep.
X,Y,Z,3 each axis for 3 hours. As shown in FIG.5
D R A W I N G N O . T C 0 8 2 0 9
R E V . A 1
AUDIOWELL ELECTRONICSGUANGZHOUCO.LTD
http://www.audiowell.com
P A G E 4/6
TESTING INSTRUMENT AND CONDITION LIST
No.
Testing item
Testing
Equipment/Methods
Testing conditions
Resonant
Frequency
Piezoelectric Transducer
Resistance Testing System
II
Testing temperature :252C
Echo Sensitivity
According to Fig. 1 Test
Circuit
Distance to obstacle: 1 meter ,
Obstacle: organic glass board with
20CM*20CM*1.0CM
1.The inductance :8mH, Q m Value: 60-80,
Pulse 20
2.The Minimum detect distance35cm
3.The acoustic system without coupling
Ring Time
According to Fig. 1 Test
Circuit
The sensor surface is covered by 100mm
thickness of sponge
1.The inductance :8mH,Qm Value: 60-80, Max
Pulse 20
2.The Minimum detect distance35cm
3.The acoustic system without coupling
Directivity
According to Fig.1 & Fig.
2 Test Circuit
In normal room temperature,
the distance to the ground: 55cm
the distance to the obstacle: 50cm
the obstacle: diameter of 50mm PVC pipe,
the obstacle height: 1 meter
Note: there is no other obstacle in a circumference
of 1 meter.
Capacitance
Digital LC ZL5
Testing temperature :252C
Maximum Input
VoltageV p-p)
According to Fig.1 Test
Circuit Oscillograph
Pulse Width: 0.5mS, Interval :20mS
Tektronix TDS1002
Mean Time to
Failure
Aging Equipment
AWHY001
Testing temperature :252C
Operating
Temperature(C)
High-Low alternating
temperature Cabinet
In normal room temperature, according to the Fig.
4 test circuit
Storage
Temperature(C)
High-Low alternating
temperature Cabinet
In normal room temperature, according to the Fig.
4 test circuit
D R A W I N G N O . T C 0 8 2 0 9
R E V . A 1
AUDIOWELL ELECTRONICSGUANGZHOUCO.LTD
http://www.audiowell.com
P A G E 5/6
NOTE:
1. DESIGN RESTRICTION/PRECAUTIONS
This sensor is designed for use in air environment. Do not use it in liquid.
In the case where secondary accidents due to operation failure or malfunctions can be anticipated,
add a fail safe function to the design.
In the case where this sensor is to be hold in housing, use soft buffer between sensor and housing.
The front convex part of this sensor vibrates in large extension. If this part is hold, its
characteristics will vary. The top must be free to vibrate.
THE
SOFT
BUFFER
1.0m m
FRONT
PART
1.0m m
HOUSE
HOUSE
2. USAGE RESTRICTION/PRECAUTIONS:
To prevent sensor malfunctions, operational failure or any deterioration of its characteristics, do
not use this sensor in the following, or similar conditions.
a) In strong shock or vibration.
b) In high temperature and humidity for a long time.
c) In corrosive gases or sea breeze.
d) In an atmosphere of organic solvents.
e) In dirty and dusty environments that may contaminate the sensor front.
f) Over specified allowable input voltage(Vp-p)
Do not solder adding stress on outer lead, also do not apply stress like spin or pressure just after
soldering.
In case you form the leads, support the root firmly.
3. WARRANTY:
Period
Warranty period is three years after delivery.
Scope
Defective sensors attributable to manufacturer responsibility shall be replaced for free during the
warranty period.
However, following cases are out of the scope.
a) Unsuitable handling or misuse by user.
b) Modification or repair by user.
c) Any other cases not due to manufacturerresponsibility such as natural calamity, accident .etc.
This scope covers only replacement.
Any loss derived from failure or malfunction of the sensor, or cost on replacing is excluded from
this warranty scope.
D R A W I N G N O . T C 0 8 2 0 9
R E V . A 1
AUDIOWELL ELECTRONICSGUANGZHOUCO.LTD
http://www.audiowell.com
P A G E 6/6