GigaLine outdoor cable, central
loose tube 2500N
Fibre optic outdoor cable, single tube, longitudinally watertight,
with corrugated steel tape armour
Type
KL-A-DQ(ZN)2Y(SR)2Y 1 x m G/E..
Construction:
1) Fibre:
single mode fibre E9..10/125 m
multi mode fibre G50/125 m
multi mode fibre G62.5/125m
Colour code:
fibres 1-12: red, green, blue, yellow, white, grey, brown, violet,
turquoise, black, orange, pink Fibres 13-24 with black ring sign:
red, green, blue, yellow, white, grey, brown, violet, turquoise,
nature, orange, pink
2) Core:
gel-filled loose tube up to 12 fibres 2.9mm, up to 24 fibres
3.5mm
3) Strain-relief
aramid yarns/glass rovings
4) Sheath:
PE
5) Armour:
sheath with corrugated steel tape
6) Sheath:
PE, sunlight resistant
Colour outer sheath:
Jet black RAL-9005
Longitudinal watertightness:
IEC 60794-1-2 F5
Halogen acid gas emission:
IEC 60754-1
INDUSTRY
Fibre quality:
0,36F3,5/0,22H18; E9..10 low OH, OS2
3.0B250/0.7F800-GBE500/1000; G62.5/125 OM1e
2,5B600/0,7F1200-GBE750/2000; G50/125 OM2e
2.5B1500/0.7F500-10GBE300; G50/125 OM3 bendable
Impact:
IEC 60794-1-2 E4
Bending:
IEC 60794-1-2 E11
Chemical continuance:
Printing Inkjet:
LEONI GigaLine A-DQ(ZN)2Y(SR)2Y n x m $fibre type$ $~~$
$reel no.$ $ $meter mark$
Free of hazardous substances acc. to RoHS 2002/95/EG
Temperature test:
IEC 60794-1-2, method F1
Strain-relief elements:
Temperature range
Transport and storage -25C to +70C
During installation -5C to +50C
After installation -25C to +60C
IEC 60794-1-2, method E1
Crush:
IEC 60794-1-2, method E3
Bending radius
After installation: 15 x outer diameter
During installation: 20 x outer diameter
LEONI Kerpen GmbH Zweifaller Str. 275-287 D-52224 Stolberg, Tel. +49(0)2402-17-1, Fax +49(0)2402-75154,
Email [email protected], www.leoni-infrastructure-datacom.com
Valid except for misprints and errors. Technical values subject to change (without notice).
The original document is in German language. In case of doubt or conflict, the German language version will prevail.
GigaLine KL-A-DQ(ZN)2Y(SR)2Y
Fibre optic outdoor cable, single tube, longitudinally watertight,
with corrugated steel tape armour
Type
KL-A-DQ(ZN)2Y(SR)2Y 1 x m G/E..
Application:
Outdoor cable for laying directly in the ground or in conduits and in case of high risk of damage by rodents, for MAN (city
networks) and LAN ( campus/backbone). For installation in generic cabling acc. to ISO/IEC 11801, ISO/IEC 24702, EN
50173-1 and EN 50173-3.
Ideal for all applications of Classes OF 300 to OF 10000 (depending on the fiber).
Suitable for splicing
Installation:
Outdoor, in conduits or on covered cable trays. For automated cable pulling via cable winches the use of tensile-forcerecording equipment is obligatory.
Dimensions:
INDUSTRY
Outer-:
Weight:
Strain-rel
ief elements:
mm (ca.)
kg/km (approx.)
N (max.)
Long term
N / dm (max.)
Short term
N / dm (max.)
MJ / m
(approx.)
kWh / m
(approx.)
1x2
12,5
160
2500
2500
3500
1,80
0,50
1x4
12,5
160
2500
2500
3500
1,80
0,50
1x6
12,5
160
2500
2500
3500
1,80
0,50
1x8
12,5
160
2500
2500
3500
1,80
0,50
1x10
12,5
160
2500
2500
3500
1,80
0,50
1x12
12,5
160
2500
2500
3500
1,80
0,50
1x24
12,5
160
2500
2500
3500
1,80
0,50
* on request
Crush resistance:
Calorific value:
Dimensions:
Low OH OS2
E9...10/125
GBE 750/2000 OM2e
G50/125
10GBE300 OM3 bendable
G50/125
1x2
LKD8AC700K10000
1x4
LKD8AC700K20000
1x6
LKD8AC700K30000
LKD8AA200K30000
1x8
LKD8AC700K40000
1x10
LKD8AC700K50000
1x12
LKD8AC700K60000
LKD8AA200K60000
LKD8AA500K60000
1x24
LKD8AC700K90000
LKD8AA500K90000