Introduction to PQView and PQWeb
Wieslaw Jerry Olechiw
Vice President of International Sales & System
Sales
Dranetz and Electrotek Concepts
Who Uses PQView Today?
United States/Canada
American Electric Power
Alabama Power Company
Baltimore Gas and Electric
CMS Energy
CPS Energy San Antonio
Con Edison New York
Detroit Edison Company
Dominion Virginia Power
Duke Energy Corporation
EnerNex Corporation
Entergy Services
EPRI
FirstEnergy
Georgia Power Company
Hawaiian Electric Company
Hydro One Networks
Hydro Ottawa
Maui Electric Company
NIST
Nebraska Public Power District
Northeast Utilities
Public Service Electric and Gas
Company
Public Service of New Hampshire
Salt River Project
San Diego Gas and Electric
Southern California Edison
Southern Company
Tennessee Valley Authority
United Illuminating Company
Wisconsin Public Service
Wireless from AT&T
Asia-Pacific
Ausgrid Sydney
Companhia de Electricidade
de Macau (CEM)
Guangdong Power Grid
Guangxi Power Grid Company
Hebei Electric Power Company
Henan Power Company
North China Power Grid
Orion New Zealand
Provincial Electricity Authority
Shandong Provincial Electrical Power
Corporation
Shanghai Municipal Electric Power
Company
Shanghai Jiu Long Electric Power Science
& Technology Company
Shanxi Power Company
Yunnan Power Grid Corporation
Transpower New Zealand
Latin America
Central Hidroelctrica de Caldas
Operador Nacional do Sistema Elctrico
2
Europe
Agder Energi Nett AS
BKK Nett AS
CEE Energiteknikk AS
Central Networks (E.ON)
DEM Slovenia
Elektro Slovenia
Elektrobistand
Hlogaland Kraft AS
Helgelandskraft AS
Hydro Aluminium AS
Hrvatska Elektroprivreda (HEP)
Istad Nett AS
Lyse Nett AS
Nordmre Energiverk AS
Notodden Energi AS
PSE-Operator
Rdy-Lury Kraftverk AS
SFE Nett AS
Skagerak Nett AS
SINTEF
Statnett
StatoilHydro
Sunnfjord Energi AS
Sweco Grner AS
Tafjord Kraftnett AS
Tussa Nett AS
2012 Electrotek Concepts, Inc. All rights reserved.
What data is stored in a PQView Database?
Circuit
Breaker
Operations
Data Logs
RMS Samples
Waveform
Samples
Event Causes
PQView
Database
Geospatial
Attributes
2012 Electrotek Concepts, Inc. All rights reserved.
What are the data sources
for a PQView Database?
Digital Fault
Recorders
Energy
Meters
Microprocessor
Relays
Power Quality
Monitors
SCADA Logs
PQView
Database
System
Models
2012 Electrotek Concepts, Inc. All rights reserved.
What analysis functions are offered by
PQView?
Event
Analysis
Compliance
Summaries
Reports
PQView
Database
Notifications
Indices
Fault
Analysis and
Location
2012 Electrotek Concepts, Inc. All rights reserved.
Components of PQView 3
Desktop
Applications
Web
Applications
PQView
Database
Developer
Tools
PQ Data
Manager
(PQDM)
PQWeb
Microsoft Access
Software
Developers Kit
(SDK)
PQ Data
Analyzer (PQDA)
WebPQView
Microsoft SQL
Server
PQDIF Library
(PQDCOM4.DLL)
PQView Express
GIS Fault
Visualizer
PQView ActiveX
Libraries
2012 Electrotek Concepts, Inc. All rights reserved.
Companies that Produce Power System Sensors or
Software Integrated by PQView Users Today
Advantech
Grounded Power
Arbiter Systems
HIOKI
Cooper Power Systems CYME
Landis+Gyr
Dranetz
Linbo
Edison Electric Institute
OSIsoft
EDMI
Power Monitors, Inc. (PMI)
Electro Industries
PSL Power Standards Labs
Electrotek Concepts
Qualitrol/LEM Instruments
E-MAX Instruments
SATEC
Fluke/Reliable Power Meters
Schneider Electric/Power Measurement
General Electric
Schweitzer Engineering Laboratories (SEL)
GL Industrial Group/Stoner Software
SynerGEE Electric
Siemens
Gossen Metrawatt
Unipower
GridSense
Utility Systems Inc. (USI)
SoftSwitching Technologies
2012 Electrotek Concepts, Inc. All rights reserved.
IEEE COMTRADE Files
SEL Relays
SEL 5045 acSELerator
Team Software
PQView
PQ Data Manager
GE
EnerVista
GE Relays
Qualitrol Relays
BEN32 Master
Station Software
COMTRADE
Folders
PQView Database
Other Relays
Softstuf Wavewin
Data Collection
SUBNET Solutions
SubSTATION Server
8
2012 Electrotek Concepts, Inc. All rights reserved.
Signature System/Encore Series
InfoNode Server
HTTP or Telephone
Modem Connection
PQView PQ
Data Manager
IEEE 1159.3 PQDIF Files
PQView Database
DataNodes
2012 Electrotek Concepts, Inc. All rights reserved.
PQView Integration with ION Enterprise
or WinPM.Net Database
Requires installation of optional ION Enterprise Database Data
Handler
Telephone or
Ethernet
Connections
PQView PQ
Data Manager
ION Enterprise
ION and ACM
Meters
ION
Enterprise
Database
10
PQView
Database
2012 Electrotek Concepts, Inc. All rights reserved.
OSIsoft PI System
Requires installation of optional OSIsoft PI SDK and Electrotek
PiSlicer Library
PI SDK
PiSlicer Library
PQView PQ Data
Manager
PiSlicer
PQView
Databases
PI Server
PI Server
PI Server
11
2012 Electrotek Concepts, Inc. All rights reserved.
PQView Integration
with Dranetz Portable Monitors
Power Xplorer
PQView PQ Data
Manager
Power Guide
DDB Files
Power Visa
PQView
Database
Energy Platform EP-1
12
2012 Electrotek Concepts, Inc. All rights reserved.
More Data Sources
Cooper Power Systems CYME
Dranetz PES Databases
Electro Industries/General Electric
Communicator Log EPM Files
Fluke/Reliable Power Meters
(RPM) Omega and Scenario
Databases
GL Industrial Group/Stoner
Software SynerGEE
Gossen Metrawatt Portable
Monitors
GridSense PowerView
GroundedPower Text Files
HIOKI Text Files
Landis+Gyr Text Files
PQView Text File Formats
PQView Databases
SATEC PAS Databases
Siemens SICARO PQ Manager Text
Files
SoftSwitching Technologies I-Grid
Web Site
www.pqview.com/data-sources/
13
2012 Electrotek Concepts, Inc. All rights reserved.
Custom Data Sources
Alabama Power Company SCADA Database
Con Edison AMR Databases
Ergon Energy Australia AMR Database
Progress Energy Feeder Management System Database
Provincial Electric Authority (PEA) Thailand AMR Database
14
2012 Electrotek Concepts, Inc. All rights reserved.
Dranetz PQNode 8010
Monitors
Proprietary Dialup
PQNode
Data Files
InfoNode Servers
File Share
MMS via WAN
HTTP
via LAN
Dranetz DataNode 5530
Monitors
InfoNode Servers
PQView
HTTP via RAS
Dranetz DataNode 61000
Monitors
HTTP
via LAN
HTTP via Frame Relay
InfoNode Servers
Schneider Electric
ION Meters
HTTP
via LAN
ION Server
SEL and GE Relays
LAN
File
Share
Microsoft
SQL Server
Frame Relay
EnerVista Download Server
COMTRADE
Files
LAN
GE XA/21
PI SDK
SCADA RTU Sensors
ECC PI Server
PQView
Databases
PQView Event Analysis
Waveform Samples for Voltage Sag
Duration: 0.08333s Minimum: 50.29%
Va
Vb
Vc
Ia
Ib
Ic
In
Voltage (%)
100
50
0
-50
-100
RMS Samples for Voltage Sag
Duration: 0.08333s Minimum: 50.29%
Va
-200
0.00
Vb
Vc
Ia
Ib
Ic
In
100
0.02
0.04
0.06
0.08
0.10
Time (s)
0.12
Voltage (%)
Current (A)
200
Electrotek/EPRI
90
80
70
0.14
60
0.16
0.18
PQView
Current (A)
50
200
150
100
50
0
0.00
16
Electrotek/EPRI
0.05
0.10
0.15
0.20
0.25
0.30
Time
(s)2012 Electrotek Concepts, Inc. All rights reserved.
PQView
Derivations from Waveform
and RMS Samples
Reactance-to-Fault
Radial Fault Location
Missing Voltage and Delta Current from First
Cycle or from Ideal Waveform
Spectrum Charts
Symmetrical Components
Delta Symmetrical Components
1, 2, 3, 4, 5, 6, 10, and 12 Cycle Windows
Phasors and Harmonic Phasors
Three-Phase Diode Rectifier Output
High-Pass Filter and Low-Pass Filter
Line Frequency during Event
First Derivative , Second Derivative, Third
Derivative, and Squared ValueTime
Total Harmonic Distortion (THD)
DC Component, Fundamental Component,
and Harmonic Trends during Event
Mean Values and RMS Values
Load Resistance, Load Reactance, Load
Impedance, and Load Impedance Angle
Links to Map Viewer and Trend Viewer
Real Power, Reactive Power, Apparent
Power, and Energy
IEEE P1159.2 Point-in Wave Characteristics
Delta Real Power, Reactive Power, Apparent
Power, and Energy
Dranetz Event Characteristics
IEEE P1159.2 RMS Characteristics
IEEE P1159.2 Missing Voltage Characteristics
Digital Status Changes
Characteristic Voltage
Operations Summary
Waveform Transformation
17
2012 Electrotek Concepts, Inc. All rights reserved.
Examples of PQView Event Derivations
Substation Bus - 1/12/2007 14:48:08.0060
Va
Vb
Vc
Ia
Ib
Ic
Voltage (V)
20000
10000
0
-10000
Substation Bus - 1/12/2007 14:48:08.0060
-20000
Reactance to Fault
Voltage (V)
2BC
0
Electrotek/EPRI
0.05
0.10
Time (s)
Vb
Vc
Vab
Vbc
Vca
Ib
Ic
Iab
Ibc
Ica
XTF
Ia
20000
15000
3ABC
10000
0.15
6000
Current (A)
-5000
Va
25000
4000
Reactance (O)
Current (A)
5000
20
0.20
0.25
PQView
2000
0
40
1.676
2BC
0
0
0.05
3ABC
0.10
0.15
1.686
0.20
0.25
Time (s)
18
2012 Electrotek Concepts, Inc. All rights reserved.
Examples of PQView Event Derivations
Substation ION 7700 - 2/1/2003 09:30:31.5377
Va
Vb
106
Substation ION
Qb 7700 - 2/1/2003 09:02:54.1855
Qc
Qa
105
-450
104
-500
1-Cycle FFT Va from -0.01735 to -0.0008137 s
Substation ION 7700 - 2/1/2003 09:02:54.1855
Total Harmonic Distortion
4.0
Va
-550
400
-0.10 380 -0.05
Electrotek/EPRI
-0.10
-600
-650
RMS
104.9
Fund
104.4
DC
0.04575
Max
108
Min
-113.6
CF
1.532
FF
1.110
THD Fund 9.73%
0.10
0.15
THD RMS 9.68%
HRMS Time10.16
(s)
Phase Jump 2.380
-700
-750
-800
-8500.05
-900
-950
-0.05
-1000
Vc
Ia
Ib
Ic
0.05
Electrotek/EPRI
-0.1
8
3.0
6
THD (%)
Voltage (%)
420
Vb
10
3.5
42.5
22.0
00.20
1.5
25
0.10 201.0 0.15
Time (s)
15
0.5
0
10
5 0
Electrotek/EPRI
Electrotek/EPRI
0.25
THD (%)
0
Current (A)
Current (A)
Ic
Reactive Power
103
-500
Ib
Vc
Ia
Ib
Ic
Substation
ION 7700
- 2/1/2003
09:30:31.5377
Vb
Reactive Power (kvar)
500
Va
107
-100
Ia
RMS
50
Voltage (%)
Voltage (%)
100
-50
Vc
Substation ION 7700 - 2/1/2003 09:02:54.1855
0
-0.10
0.30
0.20
0.35
PQView
0.30
0.35
0.25
0.1
0.2
PQView
0.3
Time (s)
10
-0.05
Electrotek/EPRI
20
0
30
40
Frequency (60 Hz Harmonic)
0.05
0.10
0.15
Time (s)
PQView
50
60
0.20
0.25
0.30
0.35
PQView
PQView
19
2012 Electrotek Concepts, Inc. All rights reserved.
Examples of PQView Event Derivations
Substation DL-8000 - 2/1/2003 00:36:16.3698
Voltage (kV)
Vab
Vbc
Vca
Ia
Ib
Ic
10
Substation DL-8000 - 2/1/2003 00:36:16.3698
-10
Frequency
Avg(Frequency)
50.08
0
50.06
-1
-2
0.0
Electrotek/EPRI
0.2
0.4
0.6
Frequency (Hz)
Current (kA)
50.10
1
50.04
50.02
0.8
1.0
Time (s)
1.2
1.4
1.6
PQView
50.00
49.98
49.96
49.94
0.0
0.2
0.4
20
0.6
0.8
Time
1.0
1.2
1.4
1.6
2012 Electrotek Concepts, Inc. All rights reserved.
Analysis of Data Logs
Substation - V RMS A, V RMS B, V RMS C
from 2/1/2003 to 3/1/2003
Substation
RMS
RMS
B,
Max[V RMS A] (kV)- VMin[V
RMS B] A,
(kV) V Avg[V
RMS B]
(kV) V RMS C
Min[V RMS A] (kV)
Avg[V RMS A] (kV)
Max[V RMS B] (kV)
Min[V RMS C] (kV)
Avg[V RMS C] (kV)
from
Max[V2/1/2003
RMS C] (kV)to 3/1/2003
Relative Frequency
30%
7.0
5.5
24183
6.785
7.105
7.299
0.5141
0.08452
6.826
6.931
7.068
7.121
7.162
7.215
7.244
0.04703
25%
Relative Frequency
6.0
Count
Min
Avg
Max
Range
St Dev
CP01
CP05
CP25
CP50
CP75
CP95
CP99
SI Range
80%
20%
60%
15%
40%
10%
20%
5%
1 Sat
Feb 2003
EPRI/Electrotek
8 Sat
100%
15 Sat
0%Time
22 Sat
Cumulative Frequency
6.5
Cumulative Frequency
1 Sat
0%
PQView 7.2
6.8
6.9
7.0
7.1
Avg[V RMS A] (kV), Avg[V RMS B] (kV), Avg[V RMS C] (kV)
EPRI/Electrotek
PQView
21
2012 Electrotek Concepts, Inc. All rights reserved.
Analysis of Data Logs
Voltage THD versus Real Power
From 1/1/2008 to 2/1/2008
V THD A (%)
P A (MW)
3.5
3.0
2.5
Voltage THD versus Real Power
2.0
From 1/1/2008 to 2/1/2008
12.0
1.5
12
11.5
11.0
10
10.5
10.0
8
7
8 Tue
15 Tue
Time
P A (MW)
MW
11
1 Tue
Jan 2008
Electrotek/EPRI
R=0.4343
9.5
9.0
22 Tue
8.5
1 Fri
PQView
8.0
7.5
7.0
6.5
1.5
2.0
Electrotek/EPRI
2.5
V THD A (%)
3.0
3.5
PQView
22
2012 Electrotek Concepts, Inc. All rights reserved.
Phasor and Harmonic Analysis
Sample Site 2
05/01/1995 04:03:57
0
-120
Vc
Ia
+120
120
Va
Vb
Ib
CP Ic95 Values
90
Service Entrance 5530, From 2/1/2003 to 3/1/2003
60
Waveform Measured at Arc Furnace
Va
Vb
150
12-Cycle DFT for Va from0 toVc
0.1998 s
30
4.0
0.025
3.5
3.0
0.5
RMS:
Fund:
Max:
Min:
CF:
FF:
THD Fund:
THD RMS:
TID Fund:
270
TID RMS:
HRMS:
Phase Jump:
2.5
2.0210
1.5
240
1.0
EPRI/Electrotek
0.5
1.0
1.429
1.429
1.404
-1.403
330
1.389
1.113
2.18%
300
2.18%
1.12%
1.12%
0.03117
0
0.0
THD
Voltage (%)
Voltage (%)
180
Electrotek/EPRI
0.020
0.015
0.010
PQView
0.005
11
13
23
17
PQView
0.000
Electrotek/EPRI
15
100
200
300
Frequency(Hz)
400
500
600
PQView
2012 Electrotek Concepts, Inc. All rights
reserved.
RMS Voltage Variation Analysis
RMS Variation Magnitude-Duration Scatter Plot
Single Site, From 1/1/1996 To 1/1/2003
SARFI-90
SARFI-85
SARFI-70
50
1.4
1.2
1.0
0.8
0.6
0.4
40
30
20
10
0.2
0.0
10-3
10-2
10 -1
100
101
Duration (s)
10 2
1997
103
1998
1999
2000
Month
2001
SARFI Rates by Year
Selected Sites, From 2/1/2003 To 3/1/2003
Selected Sites, From 1/1/1996 To 1/1/2003
0.4
0.2
0.0
yc
< 11cccyyccc
23 cyyc
4 c cyc c
5 cy c
10 cy
6 toto 2 0 0 cycyc
10 0 to 3 60 c sec
2 0 to 2
c
3 1 to 5 se ec
o
2 t 10 s se c
o
5 t o 30 sec
t
0
c
Du
10 to 6
se
ra
0
c
30
tio
12
se
0
to
n
12
60
>
85
7850 toto 90
6750t toto78805
0 too 705
56
5
5 t 6
4 0t o6 5
)
4 5 t o 55 0
3 0 to o 5 0
(%
30 5 to 4 45
e
d
25 to 3 0
tu
5
2 0 to
ni
1 5 to 3 0
ag
M
10 to 2 25
0
to
5
ge
1
to
lta
0
10 5
to
Vo
5
SARFI-ITIC - Events per 365 Days
0.6
2003
PQView
Sag and Interruption Rate Magnitude-Duration Column Chart
Events per Site per 30 Days
2002
PQView Electrotek/EPRI
Electrotek/EPRI
10
0
1996
Electrotek/EPRI
SARFI-50
60
Events per 30 Days
Voltage Magnitude (pu)
Site Name
Service Entrance 3100
Service Entrance 5530
Service Entrance 5540
Service Entrance 5571
Service Entrance 7100
Service Entrance 7700
Substation 3720
Substation 5530
Substation 7700
Substation 8010
Substation DFR
SARFI Rates by Month
Selected Sites, From 2/1/2003 To 3/1/2003
2.0
Total Events: 47
1.8
Events Violating ITIC Lower Curve: 14
Events Violating ITIC Upper Curve: 0
1.6
PQView Electrotek/EPRI
24
1997
1998
1999
Year
2000
2001
2002
PQView
2012 Electrotek Concepts, Inc. All rights reserved.
Transformed waveforms
6 6k V M ea su re d - 5 /0 9/2 010 04 :3 1:2 9.5006
Vab
V bc
Vca
70 0 00
65 0 00
Voltage (V)
60 0 00
55 0 00
50 0 00
45 0 00
40 0 00
0
0 .5
1 .0
1. 5
2. 0
2. 5
Tim e ( s)
P o we r Q u a lity S o lu tio n s
P Q Vie w
25
2012 Electrotek Concepts, Inc. All rights reserved.
Transformed waveforms
6 6k V M ea su re d - 5 /0 9/2 010 04 :3 1:2 9.5006
Vab
V bc
Vca
70 0 00
65 0 00
Voltage (V)
60 0 00
55 0 00
50 0 00
45 0 00
40 0 00
0
0 .5
1 .0
1. 5
2. 0
2. 5
Tim e ( s)
22kV Transformed L-L Load - 5/09/2010 04:31:29.5006
P o we r Q u a lity S o lu tio n s
Vab
Vbc
Vca
21000
1 delta-star
1 delta-star
L-L
L-L
20000
Voltage (V)
P Q Vie w
19000
18000
17000
16000
15000
0.0
0.2
0.4
0.6
0.8
1.0
Time (s)
Event Description:
Power Quality Solutions
PQView
26
2012 Electrotek Concepts, Inc. All rights reserved.
Transformed waveforms
6 6k V M ea su re d - 5 /0 9/2 010 04 :3 1:2 9.5006
Vab
V bc
Vca
70 0 00
65 0 00
Voltage (V)
60 0 00
55 0 00
50 0 00
45 0 00
40 0 00
0
0 .5
1 .0
1. 5
2. 0
2. 5
Tim e ( s)
3.3kV Transformed 2Tx L-L Load - 5/09/2010 04:31:29.5006 P Q Vie w
P o we r Q u a lity S o lu tio n s
Vab
Vbc
Vca
3200
3100
2 delta-star
3000
Voltage (V)
2900
2800
L-L
2700
2600
2500
2400
2300
2200
2100
0.0
0.2
0.4
Time (s)
Event Description:
Power Quality Solutions
0.6
0.8
1.0
27
PQView
2012 Electrotek Concepts, Inc. All rights reserved.
Transformed waveforms
6 6k V M ea su re d - 5 /0 9/2 010 04 :3 1:2 9.5006
Vab
V bc
Vca
70 0 00
65 0 00
Voltage (V)
60 0 00
55 0 00
50 0 00
45 0 00
40 0 00
0
0 .5
1 .0
1. 5
2. 0
2. 5
Tim e ( s)
P o we r Q u a lity S o lu tio n s
P Q Vie w
415V Transformed 2Tx L-N Load - 5/09/2010 04:31:29.5006
Va
Vb
Vc
230
22 delta-star
delta-star
220
L-N
L-N
Voltage (V)
210
200
190
180
170
-0.1
0.0
0.1
Power Quality Solutions
0.2
0.3
0.4
0.5
0.6
Time (s)
Event Description:
0.7
0.8
0.9
1.0
28
PQView
2012 Electrotek Concepts, Inc. All rights reserved.
Transformed waveforms
2 delta-star
3.3kV Transformed 2Tx L-L Load - 5/09/2010 04:31:29.5006
6 6k V M ea su re d - 5 /0 9/2 010 04 :3 1:2 9.5006
Vab
V bc
Vca
Vab
Vbc
Vca
L-L
3200
70 0 00
3100
3000
65 0 00
2900
Voltage (V)
Voltage (V)
60 0 00
55 0 00
2800
2700
2600
2500
2400
50 0 00
2300
2200
45 0 00
2100
40 0 00
0.0
0
0 .5
1 .0
1. 5
2. 0
0.2
0.4
2. 5
22kV Transformed L-L Load - 5/09/2010 04:31:29.5006
P o we r Q u a lity S o lu tio n s
Vab
Vbc
1.0
415V Transformed 2Tx L-N Load - 5/09/2010 04:31:29.5006
Vb
PQView
Vc
230
2 delta-star
220
L-N
210
Voltage (V)
19000
0.8
Power Quality Solutions
Va
1 delta-star
1 delta-star
L-L
L-L
20000
Voltage (V)
P Q Vie w
Vca
21000
0.6
Time (s)
Event Description:
Tim e ( s)
18000
200
190
17000
180
16000
170
15000
0.0
0.2
0.4
0.6
0.8
1.0
-0.1
Time (s)
Event Description:
Power Quality Solutions
PQView
0.0
0.1
29Power Quality Solutions
0.2
0.3
0.4
0.5
0.6
0.7
0.8
0.9
1.0
Time (s)
Event Description:
2012 Electrotek Concepts, Inc. All rights reserved.
PQView
PQWeb Analysis via Internet
30
2012 Electrotek Concepts, Inc. All rights reserved.
PQWeb Analysis via Internet
31
2012 Electrotek Concepts, Inc. All rights reserved.
PQWeb Analysis via Internet
32
2012 Electrotek Concepts, Inc. All rights reserved.
PQView Application Study
Guangdong Power, Guangzhou, China
Provides transmission service for
38GW of load to Guangdong
Province in Southeast China
Monitors network with DranetzBMI DataNodes and Power
Measurement ION meters
Measurements available on
intranet with Chinese user
interface
Measurements record DC
transmission line performance
during monopole ground return
mode
33
2012 Electrotek Concepts, Inc. All rights reserved.
PQView Application Examples
Fault Location
System Performance
Integration of Power System Measurements with GIS
Standards Compliance
34
2012 Electrotek Concepts, Inc. All rights reserved.
Fault Location Systems with PQView
Hydro-Qubec
Detroit Edison
San Diego
Gas & Electric
Wisconsin
Public Service
United
Illuminating
American Electric Power
Con Edison
Georgia Power
Company
35
2012 Electrotek Concepts, Inc. All rights reserved.
Fault Locating Process at Con Edison
PQ Meter
Captures
Waveforms
Feeder Trips
due to Fault
PQView
Calculates
Reactance
Match Reactance
To Feeder Model
Single-Phase Fault Evolves
Single-Phase
into Two-Phase
Fault Evolves into Two-Phase
Vb
Voltage (kV)
20
0
Va Ia
Vb
Ib
Vc
Ic Ia
Ib
Ic
15.0
Visual
Fault
Locator
12.5
-5
0.00
0.05
Current (kA)
-20
XTF
17.5
10.0
5
Current (kA)
Vc
Reactance (ohms)
Voltage (kV)
Va
10.0
2
1
7.5
Dispatch
Crews
5.0
2.5
1B
0.10
Time (s)
2.195
2AB
2.216
0.15
0.05
EPRI/Electrotek
36
0.10
Time
PQView
(s)
0.15
2012 Electrotek Concepts, Inc. All rights reserved.
RTF Performance
On average, use of the Reactance-to-Fault for fault location
saves one hour per feeder restoration job because it saves use
of capacitive discharge thumpers and DC hi-pot
Recent Results for Manhattan:
Year
0-1 MH
1-3 MH
3-5 MH
5-10 MH
> 10 MH
2009
64%
24%
5%
2%
6%
2010
67%
14%
5%
3%
11%
2011
64%
20%
8%
3%
5%
Summer 2012
76%
14%
4%
4%
1%
37
2012 Electrotek Concepts, Inc. All rights reserved.
Example Correlation of Feeder Fault Event
with PI Event from SCADA Operation
50THST - 2/25/2010 08:56:10.0650
Va
Vb
Vc
Ia
Ib
Ic
Voltage (kV)
20
0
-10
50BX13E.DX
2/25/2010 08:56:12.0233
W50ST BKR 13E 39M54
CLOSE-TRIP
5000
Current (A)
Operation
Point Name
Time Stamp
Value
Description
10
-5000
1C
0
Electrotek/EPRI
Reference Cycle = 131
38
6
Time (c)
10
PQView
2012 Electrotek Concepts, Inc. All rights reserved.
Example Correlation of Feeder Reclose
Event with PI Event from SCADA Operation
50THST - 12/24/2010 22:25:48.3130
Va
Vb
Vc
Ia
Ib
Ic
Voltage (kV)
10
50BX41W.DX
12/24/2010 22:25:52.0059
W50ST BKR 41W5M90
TRIP-CLOSE
0
-5
-10
2000
Current (A)
Operation
Point Name
Time Stamp
Value
Description
-2000
0
Electrotek/EPRI
Reference Cycle = 4669
39
6
Time (c)
10
PQView
2012 Electrotek Concepts, Inc. All rights reserved.
Example Correlations of Capacitor Energizing
Event with PI Event from SCADA Operation
50THST - 12/22/2010 06:20:11.3130
Va
15
Vb
Vc
Ia
Ib
Ic
Voltage (kV)
10
0
-5
-10
50BXC2.DX
12/22/201006:20:14.0116
W50ST BKR C2 CAP_2
TRIP-CLOSE
50THST - 12/22/2010 06:35:17.1250
2000
Va
1000
-1000
-2000
-3000
2
Reference Cycle = 36880
6
Time (c)
Operation
10
Point Name
Time Stamp
Value
Description
50BXC1.DX
12/22/201006:35:20.0112
PQView
W50ST BKRC1 CAP_1
TRIP-CLOSE
Vc
Ia
Ib
Ic
5
0
-5
-10
2000
Current (A)
0
Electrotek/EPRI
Vb
10
0
Voltage (kV)
Current (A)
Operation
Point Name
Time Stamp
Value
Description
1000
0
-1000
-2000
0
Electrotek/EPRI
40
6
Time (c)
Reference Cycle = 25663
10
PQView
2012 Electrotek Concepts, Inc. All rights reserved.
One-Line Diagram of Estimated and Actual
Location in PQView and WebPQView
5/16/2007 17:15:33.0843
Line 3542
41.276
41.275
41.274
41.273
Sout h/North
41.272
41.271
41.270
41.269
Actual Fault Location
UG_PRI_14975
41.268
Trap Falls
41.267
41.266
41.265
-73.135
-73.130
-73.125
-73.120
West/East
Electrotek/EPRI
PQView
41
2012 Electrotek Concepts, Inc. All rights reserved.
One-Line Diagram with Aerial Map
of Estimated and Actual Location
Distance between estimated and actual location:200 meters
42
2012 Electrotek Concepts, Inc. All rights reserved.
PQView Application Examples
Fault Location
System Performance
Integration of Power System Measurements with GIS
Standards Compliance
43
2012 Electrotek Concepts, Inc. All rights reserved.
PQView Application Study
SARFI Performance for UI Company
UI Substations Average SARFI performance trends for 12 month periods
UI Average Number of Occurences when
Voltage at Substation's Bus fell below
specified % of Nom inal in previous 365 days
SARFI90
SARFI85
SARFI70
SARFI50
SARFI10
40
35
30
25
20
15
10
5
0
1/1/96 to
1/1/97
1/1/97 to
1/1/98
1/1/98 to
1/1/99
01/1/99 to
01/01/00
44
1/1/00 to
1/1/01
1/1/01 to
1/1/02
1/1/02 to
1/1/03
7/1/02 to
6/30/03
2012 Electrotek Concepts, Inc. All rights reserved.
How are some electric utilities using these
system-wide monitoring databases?
Distribution Fault Location
System Performance
Integration of Power System Measurements with GIS
Standards Compliance
45
2012 Electrotek Concepts, Inc. All rights reserved.
Web-Based Power Quality Monitoring
System Management Software
Map Navigation
Executive-Level Reports
Transient Event Alarms
Transient Event Analysis
Steady-State Trends Analysis
Statistics Reports
Power Quality Event Categorization
Load Analysis
Steady-State Power Quality
Assessment
Background Harmonic Analysis
Data Integrity Reports
Power Quality Report Generation
46
2012 Electrotek Concepts, Inc. All rights reserved.
Web
47
2012 Electrotek Concepts, Inc. All rights reserved.
48
2012 Electrotek Concepts, Inc. All rights reserved.
Web-Based Power Quality Monitoring
System Management Software
Software
Interface
49
2012 Electrotek Concepts, Inc. All rights reserved.
PQView Application Examples
Distribution Fault Location
System Performance
Integration of Power System Measurements with GIS
Standards Compliance
50
2012 Electrotek Concepts, Inc. All rights reserved.
EN 50160 Compliance
Typical Weekly Report by PQView in Croatia, Slovenia, &Poland
EN50160 Compliance
Week 46 - From 11/12/2006 to 11/19/2006
110 kV Substation 1
110 kV Substation 2
110 kV Substation 3
110 kV Substation 4
110 kV Substation 5
Compliance (%)
40
50
60
110 kV Substation 6
10
20
30
70
80
90
100
Freq 95%
Parameter
Freq 100%
Vrms
Vthd
Plt
Electrotek/EPRI
PQView
51
2012 Electrotek Concepts, Inc. All rights reserved.
EN 50160 Compliance
Typical Annual Report by PQView in Croatia, Slovenia, & Poland
Report on Compliance with EN 50160 - EN50160
1/1/2006 - 1/7/2007
Compliant
Noncompliant
Missing
50
Count of Weeks
40
30
20
10
0
110 kV Substation 1
110 kV Substation 3
110 kV Substation 5
110 kV Substation 2
110 kV Substation 4
110 kV Substation 6
Site Name
Compliant
49
2
1
49
43
38
Noncompliant
2
46
50
2
8
2
Missing
2
5
2
2
2
13
Electrotek/EPRI
PQView
52
2012 Electrotek Concepts, Inc. All rights reserved.
Area Substation Voltage Control
The amount of MW load determines what the voltage should be
at the area substation following a set of rules called the voltage
schedule.
Whether the voltage can be above or below the scheduled
voltage depends upong the time of day and the day of week
Methods of Controlling Area Substation Voltage
Voltage Var Control (VVC Mode)
Local Tap Changer Control System (CMVM Mode)
Manual Adjustment of Transformer Taps
53
2012 Electrotek Concepts, Inc. All rights reserved.
Area Substation Voltage Control
Voltage Control and Optimization
Process Control Tool Development
Control Variables
Voltage Deviation from Schedule
Range of Tap positions on Parallel Transformers
Range of Mvar Load on Parallel Transformers
Apply control chart methods to develop upper and lower
control limits
54
2012 Electrotek Concepts, Inc. All rights reserved.
Voltage Deviation Control Chart
Substation A
St ation PI.LE1VOLT
Scheduled Voltage
Max Volt age
M in Voltage
SCADA Voltage Deviation
Volt age Deviation LCL
Voltage Deviation UCL
L E1LODWX
14.0
kV
13.8
13.6
13.4
200
- 200
Process Control
Violation
5.01% UCL-LCL
5 Sun
Jun 2011
Con Edison
6 Mon
7 Tue
8 Wed
9 Thu
MAN- CMVM
CMVM-VVC
VVC-MAN
100
VVC-MAN
MAN-VVC
VVC-MAN
MAN-VVC
VVC-MAN
MAN- CMVM
CMVM-MAN
MAN-VVC
VVC-CMVM
CMVM-MAN
150
VVC
MW
200
10 Fri
11 Sat
12 Sun
Time
55
PQView
2012 Electrotek Concepts,
Inc. All rights reserved.
Voltage Regulation Control Weekly Report
Each cell is interactive. When you double-click on a cell, you see the
five-minute samples for that week in an interactive window.
56
2012 Electrotek Concepts, Inc. All rights reserved.
Automatic Capacitor Analysis Procedure
Record voltage and current waveforms at substation
transformers using a power quality monitor
Correlate each transient event with the SCADA operation events
stored in OSIsoft PI System
Calculate change in voltage total harmonic distortion (THD),
power factor, and reactive power (kvar) by phase for each
transient
Calculate peak voltage and parallel resonant frequency for each
transient
Analyze each transient for synchronous closing performance
Analyze each transient for restrike characteristics
Determine if the transient is upline or downline using an
algorithm based on wavelet analysis
57
2012 Electrotek Concepts, Inc. All rights reserved.
Trend Charts Possible
Maximum Peak Voltage
Delta Voltage THD
Max Delta Voltage THD
Delta Reactive Power
Delta Power Factor
Delta Reactive Power Range
Delta Power Factor Range
Parallel Resonant Frequency
58
2012 Electrotek Concepts, Inc. All rights reserved.
Synchronous Closing Methods
Grounded-wye connected capacitor banks are controlled by
closing the three phases at three successive phase-to-ground
voltage zeros, giving 60 separation between transients.
Ungrounded-wye capacitor banks are controlled by closing the
first two phases at a phase-to-phase voltage zero and then
delaying the third phase 90 degrees, which is at the phase-toground voltage zero.
PQViews new module is able to analyze how closely the closing
was to these ideal closing times.
Closing Time
Closing Angle
Synchronous Status: Early, Synchronous, Delayed,
59
2012 Electrotek Concepts, Inc. All rights reserved.
Synchronous Closing Assessment Methods
Millwood West TR1 - 8/24/2011 06:01:06.6980
Va
Vb
Vc
Vres
Ia
Ib
Ic
Ires
100
Voltage (%)
New module in testing to analyze how
measured closing time was to the ideal closing
time
50
0
-50
-100
Early, Synchronous, Delayed
2000
Current (A)
A special version of the module was
developed using Con Edison measurements to
analyze switching method employed by Joslyn
1000
0
-1000
0.01
0.02
0.03
0.04
0.05
Time (s)
0.06
0.07
0.08
Electrotek/EPRI
Manhattan
Station
Joslyn
Banks
Avenue A
C3
Parkview
Staten Island
Station
Woodrow
Joslyn
Banks
C1
PQView
Bronx/Westchester
Station
Joslyn
Banks
Cedar Street
C1
C1
East 179th Street
C1
Astor
C1A, C2, C3
Millwood
C1
Murray Hill
C3
Ossining
C1
Seaport No. 1
C1, C2, C3
Pleasantville
C1
Trade Center No. 1
C1, C2, C3
White Plains
60
C1, C2, C3
2012 Electrotek Concepts, Inc. All rights reserved.