Upgrade from TDC and TPS to Experion
Honeywell protects your investment in existing technology by offering an easy and low-risk upgrade path to the Experion
Process Knowledge System (PKS) without having to replace your entire legacy hardware and software system. With an
enviable track record of delivering innovative solutions that integrate and add value to existing installations, we allow
customers to upgrade at their own pace and with minimum possible disruption.
Commitment to Lifecycle Support
In addition to protecting your automation investment, Honeywell
Honeywell allows you to continue to benefit from your investment
is committed to protecting your people, plant and the
in TDC 2000 , TDC 3000 and TPS while leveraging Experion
environment. Experions high security network architecture,
technology, allowing you to
integrated security features and open systems security services
expand or transition your system
help protect your systems from cyber attacks and invasions. We
to meet changing or growing
help design the optimal network architecture to ensure safe
business needs at your own pace.
connections to your business LAN when required, helping you
Honeywell provides several
optimize your entire supply chain.
options for maximizing the return
from your automation
TDC 2000, TDC 3000 and TPS customers can continue to
investments:
improve their systems by adding the Experion Server and Station
to the Local Control Network (LCN). The TPS points are
Support for existing systems
Upgrade older system
hardware while maintaining
unified system infrastructure and human machine interface
(HMI)
Replace legacy systems in phases with upgrade services
and kits
Enhance system level capabilities of older systems without
replacing controllers and process interface units
Enhance Your System
automatically discovered and become part of the unified Experion
database. This gives you the ability to unify your operations and
take advantage of many business productivity enhancements:
Improve operator effectiveness and Abnormal Situation
Management by adding the Experion Station
Improve control by adding new advanced applications
Expand your system by adding the C300 controller with
embedded Profit Loop advanced control and connectivity to
multiple types of field networks
Integrate process, security and building control to protect
employees, assets and the environment
Capture best practice operational knowledge with Experion
Procedural Operations
Experion has helped thousands of customers worldwide improve
productivity and profitability. Experion transforms process control
beyond traditional distributed control system (DCS) functionality
by unifying people with process variables, business requirements
and asset management. It is the only automation system that
focuses on plant personnel and making the most of their
knowledge.
Upgrading TDC 3000 to Experion
effective solutions are available to upgrade your hardware
and software to the latest high-performance Experion Station
hardware.
Upgrading to Experion does not require the capital investment for
replacing hardware such as controllers and I/O modules unless
there is a customer-driven business case. Experion functionality,
such as innovative alarming and trending capabilities, is available
while you continue to support your Native Window or GUS
displays in a fully integrated operator environment.
Increase Operator Effectiveness
Experion enables innovative features that improve the
effectiveness of operators, such as intuitive alarm management,
analysis tools and flexible trending. In a multi-phase upgrade, the
first step is typically to upgrade the operator stations to take
advantage of these benefits.
Upgrading TDC 3000 stations to the LCN-connected Experion
Station offers a common Experion HMI connected to the existing
LCN, reducing training and maintenance by keeping existing
graphics, network, controllers and I/O in place. It provides direct
access to the LCN with read/write data access and integrated
alarm and events. Experion establishes logical console functions
across all stations so operators can see other Experion Stations.
Multiple upgrade options exist for replacing existing
Universal Station furniture with your choice of target station
platforms.
Training
Operator and engineering training solutions also support a lowrisk transition to Experion. With hands-on training available
through Honeywells Automation College, attendees experience
reduced errors and greater productivity.
Honeywells award-winning UniSim provides innovative
simulation solutions for operations, design and optimization.
Integrated with Experion, these solutions help optimize the entire
plant lifecycle and improve overall productivity.
Customers with current Solution Enhancement Support Program
(SESP) contracts benefit from Honeywells cost-effective kits and
enhancements offerings to upgrade their systems.
Low-Risk Upgrades
With Experions ability to display the TDC 3000 Native Window,
GUS displays and Experion displays from one station, no graphic
Consistent with Honeywells investment protection philosophy,
translation is required. When the need arises, Experion provides
Experion integrates with our controllers released with TDC 2000
the opportunity to create new html-based graphics that can
and carries that same philosophy forward as new products are
strategically help improve control room safety and efficiency.
released. However, if your current controller functionality does
Experion supports building or incorporating translated graphics
not support your business strategy or is facing obsolescence,
that comply with the Abnormal Situation Management
Honeywells controllers offer a low-risk integration with most
Consortiums guidelines for ergonomic displays.
existing I/O. The Experion C200 and C300 controllers feature
patented advanced process control technology embedded in the
Multiple options are available for upgrading the TDC 3000 HMI to
controller for quick execution and tighter control.
Experion, including:
The Experion controllers integrate with existing PM I/O and Logic
Connect the Basic and Extended Controllers to Experion
with the Data Hiway Ethernet Bridge, bringing in controller
diagnostics, group and detail displays.
Connect an Experion Server to the LCN to start providing
Experion-level history for trends and reports. This enables
future upgrades and expansion, including adding Experion
Stations.
After adding an Experion Server, upgrade Universal Stations
and Global Users Stations to the Experion Station. Cost-
Manager I/O, leaving the I/O modules and field wiring untouched.
Installing Honeywells upgrade kits save time and money during
the upgrade process by minimizing the impact of the upgrade
and providing the ability to move to more powerful platforms with
the least amount of disruption. Field wiring can remain in place,
untouched, and become connected to an Experion system.
Hardware upgrades last from a few hours to a few days, instead
of the weeks required with rewiring, reducing labor costs and the
possibility for human error.
Upgrading TDC 3000 to Experion
Global Expertise and Local Service
Honeywells extensive capabilities and experience help ensure a
Honeywell partners with you to help design an overall automation
successful implementation. With collaborative evaluation,
plan to align with your specific business goals. You can take
planning and execution, we can help retain your valuable
advantage of Honeywells global expertise to determine the best
intellectual property, identify opportunities for business
way to continue delivering value to your business while planning
improvement and devise an implementation plan that minimizes
a multi-year approach to upgrading or expanding your existing
risk and maximizes system lifecycle. Our project services group
installations.
offers comprehensive expert services to implement the plan and
install equipment, designed specifically to ensure that database,
Rewiring Tasks
about 11 hours for 16
point I/O card
Using Wiring Kits
about 3 hours for 16
point I/O card
Disconnect old
terminations
Removal
Install intermediate
panels and new Series
C I/O
Install new Series C
I/O
Connect cables
Documentation
Rewire from new
terminal blocks to
Experion
Documentation
graphic and other functional upgrades are accurate and costeffective. This approach includes:
Evaluation of automation goals with an audit of the current
system and process
Recommendations for HMI and effective operator displays
Network and cyber security design and implementation
Recommendations for hardware upgrades, migration, control
room design and protecting current installation investment
Personnel training and implementation plans
Optimization and integration recommendations
More Information
For more information on Honeywell upgrades and
migration solutions, visit www.honeywell.com/ps
or contact your Honeywell account manager.
Experion, TDC 2000, TDC 3000, Abnormal
Situation Management, Profit and UniSim are
registered trademarks of Honeywell International Inc.
Automation & Control Solutions
Process Solutions
Honeywell
2500 W. Union Hills Dr.
Phoenix, AZ 85027
Tel: +1-602-313-6665 or 877-466-3993
www.honeywell.com/ps
SO-06-34-ENG
December 2006
2006 Honeywell International Inc.