0% found this document useful (0 votes)
193 views2 pages

SIP Easy For The Schneider PowerLogic ION6200

MFMs

Uploaded by

sahil4IND
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
193 views2 pages

SIP Easy For The Schneider PowerLogic ION6200

MFMs

Uploaded by

sahil4IND
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 2

sip

easy for the Schneider Electric ION6200

INTRODUCTION
The SIP Easy service provides a central location to download backup files
for a range of protocol specific devices, including ModBus meters, air
handling units, generators, chillers, etc. Individual slave specific backup files
have been developed to help reduce engineering time and cost, and to meet
the demand for more information and better energy control.
The SIP products, used in conjunction with a Trend BeMS (Building energy
Management System), can help ensure a building complies with latest Part
L2 Building regulations.

APPLICATION
This service provides files for automatically populating the SIP Modbus/vIQ with a Schneider Electric ION6200 slave
configuration. Each backup file automatically configures up to 32 slaves (from slave address 1) according to the SIP
product license and up to 50 ModBus registers from each slave address. The pre-defined Modbus registers at the
configured slave addresses are mapped to Trend modules (i.e. Sensors, Digital Inputs, Knobs or Switches) in the
equivalent number of virtual out-stations (vIQ). Each vIQ provides the interface to the Trend BeMS and includes an
associated set of energy usage calculations that are used to determine the total amount of energy used over each 30
minute period.
This Backup file is only applicable when the meter is configured to operate as a slave.

Note

FEATURES

Hardware that is ready to install and use

Pre-defined communications protocol

Pre-defined slaves and addresses

Pre-defined range of points

Pre-defined vIQs and Trend Modules

Preconfigured 30 minute energy usage


calculations

OVERVIEW

Restore downloaded
SIP Easy file to
SIPe IF-Logger &
SIP ModBus/vIQ

Supervisor

Ethernet

BENEFITS
Compatible with SIPe IF-Logger/M-Logger

Compatible with MID approved meters

No configuration required, simply restore


the required backup file

Reduced engineering costs

Simplifies interface configuration, no


specialist tools or knowledge required

No additional hardware is required for


storing values

SIP Easy applications will be available for


many third party devices

OS11

OS42

vIQs present each ModBus slave


as a Trend controller.
Values are transferred as Trend Sensor
Digital Input, Knob and Switch Modules

RS485

sip

easy for the Schneider Electric ION6200

MANAGE MODBUS SLAVE ADDRESSES

DOWNLOAD A BACKUP FILE


1.

Connect to the Synapsys Solutions website,


www.synapsys-solutions.com
and login to the SIP Integrator page. Follow the on screen
instructions about downloading the slave specific Backup file.

2.

3.

Enter the required IP address (default - 192.168.1.227)


in the Navigation toolbar and login (Username Admin, Password - password) to the Main menu.
Press the
button on the Backup and
restore web page to download the slave specific file and
wait until the reboot is complete.

1.

2.

Note
1.

changing the Local IP settings (to suit local company IT policy)

managing the slave addresses

managing the vIQs


Tip!
Any further configuration should only be
performed by competent personnel.
Refer to the documentation for full details.

CHANGE THE LOCAL IP SETTINGS


1.
2.

3.

Slaves must be connected to P1 according to the ModBus


RS485 standard and addressed sequentially (i.e. 1, 2, , 32).
A 2.5m Cat 5e cable is supplied.

FROM PIN
Pin1

RS485 SIGNAL

COLOUR

METER PORT

Data+ (A)

Orange

GND

Green/White

SH

Data- (B)

Blue

5 to 8

N/A

N/A

2
3

Slaves must also be setup to use the default ModBus


communications parameter configuration.

Note

Press to remove or

Note
2.

to duplicate a selected OS.

Typically, 1 (one) product per LAN.

Use the and scrollbar buttons to find and select


the required OS.
Then select
,
,

to show the Trend Modules, as follows.

TREND
MODULES

MOD
NO.

1
2-4
5-7
8 - 10
11
12
13
14
15
16
17
18 - 20
21 - 23
24 - 26
Digital Inputs 1
Note

This shows the flat side of RJ45 plug.

Access the VIQ Pages and press to expand the OS


(out-station) management area. Change the LAN
number and press
to confirm changes.

Sensors

Repeat Login.
Press
, edit the IP configuration as
necessary and press
.
Wait until the reboot is complete and reconnect.

ESTABLISH COMMS SETTINGS

Interface firmware is available with SIP


ModBus/vIQ and SIPe IF-Logger.

Typically, any configuration should be limited to;

Press to remove the selected slave configuration


or to copy it to the next available slave address.

MANAGE VIQS

CONFIGURATION

Note

Press
to show pre-configured slave
addresses, registers and vIQ mapping.
Use and buttons to find the required slave.

or

MEASURED POINT

UNIT

kWh
Voltage A-N, B-N and C-N
Voltage A-B, B-C and C-A
Current A, B and C
Current peak demand
Current N
Frequency
Power Factor Total
kW total
kVAR total
kVA total
kW a, b and c
kVAR a, b and c
kVA a, b and c
Comms Failure

kWh
V
V
A
A
A
Hz
PF
kW
kVAr
kVA
kW
kVAr
kVA

Three energy usage calculations are


included at Sensor 51 (Energy at start of
period), Sensor 52 (Energy at end of period)
and Sensor 53 (Energy used in this period).

Baudrate 9600
Data bits 8
Parity None
Stop bits 1
Protocol ModBus
These correspond to the slave specific SIP
Easy file, but can be edited if necessary.

For further information and customisation options, please contact us as stated below.

Issue 2, Jun. 2012


Copyright Synapsys Solutions 2012

No.1 Woodlands Court, Albert Drive, Burgess Hill, West Sussex, RH15 9TN
Tel: 0845 680 0303 - Fax: 0845 680 0304
International - Tel: +44(0)1444 246128 - Fax: +44(0)1444 239527
Sales: [email protected] Orders: [email protected]
Web: http://www.synapsys-solutions.com

We reserve the right to change or amend any design or specification in accordance with our policy of continuing development and improvement. No warranty is given, implied or otherwise.

You might also like