0% found this document useful (0 votes)
231 views3 pages

TCF-142 Series PDF

TCF-142 media converters are used to extend serial transmission up to 5 km (TCF-142-M with multi-mode fiber) TCF 142 converters can be configured to convert either RS-232 signals, or RS422 / 485 signals, but not both at the same time.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
231 views3 pages

TCF-142 Series PDF

TCF-142 media converters are used to extend serial transmission up to 5 km (TCF-142-M with multi-mode fiber) TCF 142 converters can be configured to convert either RS-232 signals, or RS422 / 485 signals, but not both at the same time.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 3

Serial Media Converters

TCF-142 Series
RS-232/422/485 to fiber converters

Ring and Point- to-Point transmission


Extends RS-232/422/485 transmission up to:

40 km with single-modeTCF-142-S
5 km with multi-modeTCF-142-M
Decreases signal interference
Protects against electrical interference and chemical corrosion
Supports baudrates up to 921.6 kbps
Wide temperature models available (-40 to 75C)

Introduction
The TCF-142 media converters are equipped with a multiple interface
circuit that can handle RS-232 or RS-422/485 serial interfaces and
multi-mode or single-mode fiber. TCF-142 converters are used to
extend serial transmission up to 5 km (TCF-142-M with multi-mode

fiber) or up to 40 km (TCF-142-S with single-mode fiber). The TCF-142


converters can be configured to convert either RS-232 signals, or RS422/485 signals, but not both at the same time.

Automatic Baudrate Detection


The TCF-142 converters can automatically detect the serial baudrate.
This is an extremely convenient feature. Even if a devices baudrate

is changed, the signal will still be transmitted through the media


converter without any data loss.

Ring Operation
RS-422/485

V-

V+

T+

R-/D-

R+/D+

T-

GND

Rx

RS-232

Tx

12-48V

RS-232

RS-232/422/485
Serial to Fiber Converter

TCF-142-S

5210

Fiber Rx

TCF-142

Fiber Tx
PWR
Rx

Tx
Rx

Rx
PWR
Fiber Tx

Fiber Rx

Fiber Rx

5210

TCF-142-S
RS-232/422/485
Serial to Fiber Converter

R+/D+

V-

V+

RS-485

Tx

Rx

RS-422/485

T-

TCF-142

12-48V

GND

Rx

Tx

R-/D-

RS-232

T+

5210

TCF-142-S
RS-232/422/485
Serial to Fiber Converter

RS-422/485

R+/D+

TCF-142

T-

V-

V+

12-48V

GND

Rx

Tx

R-/D-

R+/D+

T-

T+

RS-422

RS-232

T+

5210

TCF-142-S
RS-232/422/485
Serial to Fiber Converter

RS-422/485

Tx

sw

Tx

Fiber Tx

RS-232

TCF-142

12-48V

V-

Tx

sw

PWR

V+

Rx

Tx

Fiber Rx

GND

Rx

Fiber Tx

Rx

Tx

sw

PWR

Tx

Rx

Rx

R-/D-

Tx

sw

The TCF-142 converters can be used to connect serial devices to a


fiber ring. To form the ring, connect the Tx port of one TCF-142 to the
Rx port of a neighboring converter. Once the ring is set up, simply use
the DIP switches to configure the TCF-142 converters for ring mode.
When one node transmits a signal, the signal travels around the ring
until it returns back to the transmitting unit, which then blocks the
signal. With the TCF-142, you can set up fiber rings that have a total
circumference of up to 100 km.

RS-485

Automatic Data Direction Control (ADDC)


ADDC is a patented hardware data flow solution developed by Moxa
to handle RS-485 data direction control. ADDC senses and controls

RS-485 data direction automatically, making it unnecessary to use the


hand shaking signal.

w w w. m o x a . c o m

Serial Media Converters

Specifications
Optical Fiber Side

Environmental Limits

Fiber Connector: SC or ST
Cable Requirements:
Single-mode: 8.3/125, 8.7/125, 9/125, or 10/125 m
Multi-mode: 50/125, 62.5/125, or 100/140 m
Transmission Distance:
Single-mode: 40 km
Multi-mode: 5 km
Wavelength:
Single-mode: 1310 nm
Multi-mode: 850 nm
Tx Output:
Single-mode: > -5 dBm
Multi-mode: > -5 dBm
Rx Sensitivity:
Single-mode: -25 dBm
Multi-mode: -20 dBm
Ring Transmission: Half-duplex
Point-to-Point Transmission: Half-duplex or full-duplex

Operating Temperature:
Standard Models: 0 to 60C (32 to 140F)
Wide Temp. Models: -40 to 75C (-40 to 167F)
Storage Temperature: -40 to 75C (-40 to 167F)
Ambient Relative Humidity: 5 to 95% (non-condensing)

Power Requirements

Input Voltage: 12 to 48 VDC


Power Consumption: 140 mA @ 12 V
Power Line Protection:
2 kV Burst (EFT), EN61000-4-4
2 kV Surge, EN61000-4-5
Voltage Reversal Protection: Protects against V+/V- reversal
Over Current Protection: 1.1 A (protects against two signals shorted
together)

Standards and Certifications

Safety: UL 60950-1
EMC: CE, FCC
EMI: FCC Part 15 Subpart B Class B, EN 55022 Class B
EMS:
EN 61000-4-2 (ESD) Level 3,
EN 61000-4-3 (RS) Level 2,
EN 61000-4-4 (EFT) Level 2,
EN 61000-4-5 (Surge) Level 2,
EN 61000-4-6 (CS) Level 2,
EN 61000-4-8 (SFMF) Level 1
Green Product: RoHS, CRoHS, WEEE

RS-232/422/485 Side

Connector: Terminal Block


RS-232 Signals: Tx, Rx, GND
RS-422 Signals: TxD+, TxD-, RxD+, RxD-, GND
RS-485-4w Signals: TxD+, TxD-, RxD+, RxD-, GND
RS-485-2w Signals: Data+, Data-, GND
Baudrate: 50 bps to 921.6 kbps
ESD Protection: 15 kV for all signals

Physical Characteristics

MTBF (mean time between failures)

Housing: Metal
Dimensions:
Without ears: 67 x 100 x 22 mm (2.64 x 3.94 x 0.87 in)
With ears: 90 x 100 x 22 mm (3.54 x 3.94 x 0.87 in)
Weight: 320 g

Time: 780,480 hrs


Database: Telcordia (Bellcore), GB

Warranty

Warranty Period: 5 years


Details: See www.moxa.com/warranty

DIP Switch Settings


Serial Connection

SW1

SW2

Built-in 120-ohm Terminator

SW3

Fiber Mode

RS-232

ON

OFF

Enable

ON

Ring mode

SW4
ON

RS-422

ON

ON

Disable

OFF

Point-to-Point mode

OFF

RS-485-4w

OFF

OFF

RS-485-2w

OFF

ON

Dimensions
Unit: mm (inch)

TCF-142-M/S-ST
22.0 (0.87)

6 (0.24)

67 (2.64)
78 (3.07)

22.0 (0.87)

7 (0.28)

21.3 (0.8)

42.3 (1.67)

25 (0.98)

12.5 (0.49)

100.4 (3.95)

4 (0.16)

67 (2.64)
90.2 (3.55)

w w w. m o x a . c o m

Serial Media Converters

Dimensions
Unit: mm (inch)

TCF-142-M/S-SC
22.0 (0.87)

6 (0.24)

25 (0.98)

12.5 (0.49)

100.4 (3.95)

4 (0.16)

7 (0.28)

22.0 (0.87)

21.3 (0.8)

42.3 (1.67)
67 (2.64)

67 (2.64)

78 (3.07)
90.2 (3.55)

Ordering Information
Available Models

TCF-142-M-SC: RS-232/422/485 to multi-mode optical fiber media converter with fiber ring support and SC
connector, 0 to 60C operating temperature
TCF-142-M-ST: RS-232/422/485 to multi-mode optical fiber media converter with fiber ring support and ST
connector, 0 to 60C operating temperature
TCF-142-S-SC: RS-232/422/485 to single-mode optical fiber media converter with fiber ring support and SC
connector, 0 to 60C operating temperature
TCF-142-S-ST: RS-232/422/485 to single-mode optical fiber media converter with fiber ring support and ST
connector, 0 to 60C operating temperature
TCF-142-M-SC-T: RS-232/422/485 to multi-mode optical fiber media converter with fiber ring support and
SC connector, -40 to 75C operating temperature
TCF-142-M-ST-T: RS-232/422/485 to multi-mode optical fiber media converter with fiber ring support and
ST connector, -40 to 75C operating temperature
TCF-142-S-SC-T: RS-232/422/485 to single-mode optical fiber media converter with fiber ring support and
SC connector, -40 to 75C operating temperature
TCF-142-S-ST-T: RS-232/422/485 to single-mode optical fiber media converter with fiber ring support and
ST connector, -40 to 75C operating temperature

Package Checklist
1 TCF-142 media converter
Power jack to 3-pin terminal
block adaptor
Stick-on pads
Quick installation guide (printed)
Warranty card

Moxa Inc. All rights reserved. Updated Apr. 9, 2015. Specifications subject to change without notice. Please visit our website for the most up-to-date product information.