6
Specifications
HPB Series
Photoelectric Control with
Self-contained General-use Amplifier
FEATURES
General-use Photoelectric Control Ideal for Distribution Equipment
CLICK
Retroreflective types are provided with a polarized switch as standard.
Sealability IP67. Integrated formed structure
Long scanning distance
- Thru-scan model: 10m
- Polarized retroreflective model: 2.5m
Acceptable world wide (EN compatible product) (PNP and NPN versions
available)
ORDER GUIDE
Shape
Scanning
method
Scanning
distance
Light ON/dark
ON selectable
Sensitivity
adjustment
Thru-scan
Thru-scan
(with light quantity
adjustment potentionmeter)
Supply
voltage
~
10m
Polarized
retroreflective
2.5m
(when reflector
Polarized retroreflective FE-RR8 is used)
(with light quantity
adjustment potentionmeter)
10 to
30V dc
Diffuse
scan type
0.5m
Diffuse scan type
(wide beam area)
Output mode
Catalog listing
NPN open collector
HPB-T1
PNP open collector
HPB-T2
NPN open collector
HPB-T3
PNP open collector
HPB-T4
NPN open collector
HPB-P1
PNP open collector
HPB-P2
NPN open collector
HPB-P3
PNP open collector
HPB-P4
NPN open collector
HPB-A1
PNP open collector
HPB-A2
NPN open collector
HPB-D1
PNP open collector
HPB-D2
No. CP-PC-2181E
ATTACHMENTS (ordered separately)
Product name
Shape
Description
Reflector for polarized
retroreflective model
Reflecting surface 30.8
Reflector for polarized
retroreflective model
Catalog listing
Applicable
models
FE-RR15
HPB-P
Scanning distance 2.5m
Reflecting surface 47 47mm
FE-RR8
HPB-P
Reflector for polarized
retroreflective model
Reflecting surface 8.4
32.8mm
FE-RR16
HPB-P
Reflector for polarized
retroreflective model
Reflecting surface 47
47mm
FE-RR17
HPB-P
Reflector for polarized
retroreflective model
Reflecting surface 30.9
FE-RR18
HPB-P
Reflector for polarized
retroreflective model
Reflecing surface 8.6
GP-RR20
HPB-P
30.8mm
30.9mm
29.5mm
Bottom face mounting
L-shaped bracket (material: SUS)
HPB-B01
All models
Standard bracket
Rear face mounting
L-shaped bracket (material: SUS)
HPB-B04
Cover bracket
Vertical model attachment bracket
(material: SUS)
HPB-B02
All models
Cover bracket
Horizontal model attachment bracket
(material: SUS)
HPB-B03
All models
SPECIFICATIONS
Scanning method
Catalog listing
Thru-scan
Thru-scan
(with light quantity
adjustment
potentionmeter)
Polarized
retroreflective
Polarized
retroreflective
(with light quantity
adjustment
potentionmeter)
Direct reflecting
type
Diffuse scan type
(with beam area)
HPB-T1
HPB-T2
HPB-T3
HPB-T4
HPB-P1
HPB-P2
HPB-P3
HPB-P4
HPB-A1
HPB-A2
HPB-D1
HPB-D2
10 to 30V dc
Supply voltage
Current consumption
Scanning distance
Detection object
Standard target object
Scanning angle
Differential travel
Operation mode
55mA max. Emitter: 30mA
Receiver: 25mA
30mA max.
10m
2.5m (when reflector FE-RR8 is used)
Opaque object 9mm dia. min.
Opaque object 80mm dia. min.
(when reflector FE-RR8 is used)
30mA max.
0.5m
20 20cm white paper 10 10cm white paper
2 to 20
Body: 1 to 10, reflector: 40 min.
20% max.
(within rated sensing distance)
Set operation mode selection line.
Operation mode selection line open or 0V connection: light ON/Vcc connection: dark ON
Output mode
HPB- 1, HPB- 3: NPN transistor output, open collector
HPB- 2, HPB- 4: PNP transistor output, open collector
Control output
Switching current: 100mA max. (resistive load)
Output dielectric strength: 30V
Voltage drop: 2V max. (at 100mA switching circuit)
1ms max. (for operation and recovery)
Response time
Light emitter
Indicator lamps
Ambient light immunity
(at light receiving surface)
Operating temperature range
Operating humidity range
Storage humidity range
50mm
Infrared LED
Red LED
Infrared LED
Other than thru-scan emitter: output ON indicator (orange), stability indicator (green),
Thru-scan emitter: power indicator (orange)
Incandescent lamp 5,000lx max., sunlight 20,000lx max.
~25 to +60C (icing, condensation not allowed)
35 to 85%RH (icing, condensation not allowed)
~40 to +70C (icing, condensation not allowed)
20M min. (by 500V dc megger)
Insulation resistance
Dielectric strength
1,000V ac, 50/60Hz for 1 minute between case and electrically live metals
Vibration resistance
10 to 55Hz, 1.5mm peak-to peak amplitude, 2hrs in X, Y and Z directions
Shock resistance
500m/s2 10 times in X, Y and Z directions
IP67 (IEC standard)
Protection
Pre-leaded
Wiring method
Weight
Circuit protection
Approx. 60g (body only, with 2m cord)
Reverse connection protection circuit, output short-circuit protection circuit,
power ON malfunction prevention circuit (approx. 50ms)
CHARACTERISTICS DIAGRAMS
Thru-scan model (HPB-T
Diffuse scan type (HPB-A
Parallel motion characteristics
Diffuse scan (wide beam area) (HPB-D
Detection area characteristics
Polarized retroreflective (HPB-P
Detection area characteristics
Parallel motion characteristics
Combined with FE-RR8 or FE-RR17
Combined with FE-RR15 or FE-RR18
Combined with FE-RR16
EXTERNAL DIMENSIONS
Thru-scan (HPB-T
Polarized retroreflective (HPB-P
- HPB-T1 and HPB-T2 emitters,
all receivers
- HPB-P1, HPB-P2 :
- HPB-T3 and HPB-T4 emitters
- HPB-P3, HPB-P4 :
Diffuse scan type (HPB-A
, HPB-D )
(unit: mm)
Bracket (sold separately)
Standard bracket (HPB-B01)
Cover bracket (HPB-B02)
Cover bracket (HPB-B03)
Standrad bracket (HPB-B04)
Reflector (sold separately)
FE-RR8
FE-RR16
FE-RR15
FE-RR17
FE-RR18
(unit: mm)
(unit: mm)
FE-RR20
OUTPUT STAGE CIRCUIT DIAGRAMS
Thru-scan model emitter
(NPN
output type) polarized retroreflective model,
thru-scan model receiver, diffuse scan type
(PNP output type) polarized retroreflective model, thruscan model receiver, diffuse scan type
BASIC PRECAUTIONS
Wiring Precautions
Wire the power supply and load for the photoelectric control
correctly.
This photoelectric control is influenced by current surge or
electrical noise when high-voltage leads or power leads are
placed near the photoelectric control cable. To prevent this,
wire the cable separately from these leads, or provide a
separate wiring duct for the cable.
Reliably connect the ends of the cable using a crimped terminal, for example.
When extending cords, use 0.3mm2 min. cable. Keep the cable length to within 100m. Pay attention to the influence of
noise when cables are extended beyond this length.
When a switching power supply is used, ground the frame
ground (FG) terminal on the power supply before use.
When connecting to a capacitive load, insert a current limiting
resistor to keep rush current within 100mA.
Handling precautions
Do not swing the photoelectric control by its cord.
Do not tug the cable of the photoelectric control using excessive force. The pull-out strength of the cable is 49N.
Prevent objects from bumping against or scratching the
scanning head.
Do not use this control at locations where it may be splashed
with water or oil, outdoors or in chemical (organic solvents,
acid or alkali) atmospheres.
Firmly tighten the connectors by hand.
Do not bend the cord with a minimum radius of 30mm.
Polarized retroreflective model
The polarized retroreflective model uses a light-polarizing filter,
and employs a detection method intended to prevent reflection
from mirror surfaces or shiny detection objects. For this reason,
malfunction may occur when the characteristics of the detection
body are such that the body itself polarizes light. Check this
before use.
Example
: Detection objects covered in transparent film
: Mirror surfaces with slight surface unevenness or shiny
detection objects
CAUTION
The product is designed, developed and manufactured for general-purpose application in machinery and equipment. The
product shall be handled with extra caution to provide fail-safe and/or redundant design in the applications listed below that
required strict safety.
-
applications
applications
applications
applications
applications
for
for
for
for
for
physically protecting people
directly controlling transportation equipment and machinery
aircraft
spacecraft
nuclear reactors
Do not use any of this product for applications where product functions directly influence peoples safety.
lssued Apr., 2002