Entegris Quick Connect System 3560-2438-0113

The document discusses the Sentry QCIII Quick Connect System from Entegris which provides a clean, safe and easy connection system for high-purity bulk chemical dispensing. The system uses a key-coded dispense head and drum insert that self-aligns and seals without o-rings for minimal maintenance. It allows for both dispensing and recirculation from a single connection and includes features for traceability and higher flow rates.

Uploaded by

TB
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
663 views8 pages

Entegris Quick Connect System 3560-2438-0113

The document discusses the Sentry QCIII Quick Connect System from Entegris which provides a clean, safe and easy connection system for high-purity bulk chemical dispensing. The system uses a key-coded dispense head and drum insert that self-aligns and seals without o-rings for minimal maintenance. It allows for both dispensing and recirculation from a single connection and includes features for traceability and higher flow rates.

Uploaded by

TB
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 8

Contamination Control Solutions

Sentry QCIII Quick Connect System


The cleanest, safest, most user-friendly connection system
available for high-purity bulk chemical dispense

Sentry QCIII Quick Connect System

safe, easy-to-use
dispense system
Materials Integrity
Management
For nearly 40 years, Entegristhe industry experts
for materials integrity management solutions
has been committed to purifying, protecting and
transporting the critical materials that enable the
worlds leading technologies. Materials integrity
management starts with the chemicals that come
into direct contact with every wafer and IC produced. To help you safely handle these high-purity,
microelectronic-grade chemicals, Entegris offers
the Sentry QCIII quick connect systema reliable
means for filling containers or connecting a bulk
chemical source to the chemical dispense unit.

Sentry QCIII Quick


Connect Systems
Entegris introduced our first patented Quick
Connect System over 20 years ago and our system
remains the industry standard for high-purity
chemical dispense. Expanding on the proven performance and functionality of this quick connect

system, the Sentry QCIII quick connect system is


todays safest and easiest method of connecting
chemical containers with typical bulk chemical
delivery systems. This patented connection system
comprises a key coded dispense head (DH) and
drum insert (DI) that self align. Simply rotating the
retaining ring pulls the DH and DI together so no
visual line of site is required to make the connectionsimplifying the assembly process significantly.
The Sentry QCIII quick connect system is designed
for use with FluoroPure chemical containers
including HDPE transport drums, PFA composite
drums, pressure vessels and intermediate bulk
containers.
O-ring Free Main Dispense Seal
The main chemical dispense line utilizes Entegris
industry leading Flaretek sealing technology,
which provides a leak-free, secure connection
without o-rings. This sealing technology decreases
your cost of ownership by eliminating the need
for o-ring replacement and maintenance while
minimizing downtime.

By utilizing Flaretek sealing technology in the main dispense


line, Entegris has eliminated o-rings, reducing maintenance
and decreasing cost of ownership.

The Sentry QCIII quick connect system is available with a


3-port or 4-port dispense head and a drum insert of either
PFA or polyethylene material.

Entegris, Inc.

Sentry QCIII Quick Connect System

Recirculation and Dispense in One


Designing four ports into the system enables recirculation and dispense operations in one connection.
This eliminates the need for an independent recirculation dispense head and drum insert. The single
DI connection assembles faster, requires less labor,
reduces maintenance and thus lowers your costs.

Assembly
Dispense
head
Shipping
plug

1. 3 4" fill and dispense port allows higher flow in


either filling or dispense applications
2. 1 2" vent port allows proper ventilation during
chemical dispense operations
3. 1 4" connection verification port ensures proper
DH/DI engagement prior to initial dispense
operations if OEM equipment is equipped with
this feature

Drum
insert

Dispense Head Assembly Cross Sectional View

4. Optional 3 4" recirculation port allows chemical


recirculation; an optional diffuser, which reduces
chemical agitation and foaming typical with
chemicals containing surfactants
Higher Flow Rates
Entegris innovative dispense head optimizes the
flow path to allow chemical dispense at 1.5x the
flow rate of standard quick connect systems. This
larger flow volume increases the overall capacity
of your bulk chemical dispense system, reducing
recirculation time and increasing process efficiency.

Dispense
head
Check
valves

Retaining
ring

Drum insert
PFA or PE
material

Easy Product Traceability


NOTES:

The 1 4" Flaretek verification port is not shown


due to cutaway view
Due to the large quantity of key coded options,
drum inserts are key coded per customer order
Port Options
Optional
Flaretek
recirculation
port
34

12

Permanent serialized laser marking on the dispense head,


drum insert and ID tag allow for easy product identification
and traceability.

Both the dispense head and drum insert are laser


marked, allowing quick, visual identification.
Permanent serialized laser marking is nonintrusive
and noncontaminating. Laser marking allows for
100% traceability to a production date and production
inspection record.
Entegris, Inc.

Flaretek
vent port

34

Flaretek
fill and
dispense port
14

Flaretek
connection
verification
port

Sentry QCIII Quick Connect System

Performance Data
Dispense Port Water Flow vs. Pressure Drop
0

GPM
10

15

137.9

20

103.4

15
Pressure drop
flow in (DI3T)

68.9

10

Pressure drop
flow out (DI3T)

34.5

Differential Pressure (psig)

The Sentry quick connect system is the industry


standard for interfacing FluoroPure containers
with bulk chemical delivery systems safely and
con- veniently. Entegris patented quick connect
system is key coded to assure against unsafe chemical mixing while guaranteeing dedicated clean
service. One connection provides dispensing,
recirculation, venting and connection verification.

Differential Pressure (kPa)

Key Codes

0
0

18.9

37.8
56.8
Flow Rate (L/min)

75.7

Dispense Port Water Flow vs. Pressure Drop

Entegris patented quick connect system is key-coded to


assure against unsafe chemical mixing.
Dispense Head Rotating
Code Ring Notches

Drum Insert Key Code Tabs


J

15

137.9

20

103.4

15
Pressure drop
flow in (DI3P)

68.9

10
Pressure drop
flow out (DI3P)

34.5

GPM
10

Differential Pressure (psig)

Differential Pressure (kPa)

0
0

18.9

37.8
56.8
Flow Rate (L/min)

75.7

G
A

B
E

F
B

A series of seven tabs/slots are used to make up each


chemical code.

Specifications
Materials of
construction:

Dispense head

Wetted parts include PFA, FEP and Kalrez 4001 materials/Kalrez 6221 for
Life Sciences applications
Nonwetted parts are PFA and polyethylene

Drum insert

Wetted parts are PFA or polyethylene with FEP encapsulated o-rings


Nonwetted parts are polyethylene. Nut materials are PFA, PVDF and CPFA

Operating
conditions:

Maximum pressure

Regulatory:

All internal wetted surfaces are made from resins that comply with FDA regulation 21 CFR 177.1550
or 21 CFR 177.2600 for use as articles or components of articles intended to contact food. Representative samples of these resins have been tested for biocompatibility in accordance with USP
protocol and all meet the requirements of a USP Class VI (121 C) plastic. These resins also do not
use any animal derived materials as intentional components.

207 kPa (30 psig) @ 77F (25C)

Entegris, Inc.

Sentry QCIII Quick Connect System

Ordering Information
FluoroPure Drum Inserts
Part Number

DI3

Special Instructions
00 = Standard angle cut
on DIP tube
01 = No angle cut
on DIP tube

DI Tracking Tag
0 = Standard serial number tag
1 = No tag
2 = RF enabled
3 = Special instructions

O-ring Material
(Shipping Cap)
0 = FEP encapsulated silicone
1 = FEP encapsulated Viton
2 = FEP encapsulated EPDM

Shipping Cap
0 = Standard
3 = Manual relief
6 = Vented (H2O2 )

Chemical Key Code


Reference the Fluid Handling Systems
catalog for chemical codes.

Drum Insert Length


01 = 55 gallon FluoroPure PFA composite drum
02 = 30 gallon FluoroPure PFA composite drum
03 = 15 gallon FluoroPure PFA composite drum
07 = 100 liter FluoroPure pressure vessel
08 = 20 liter FluoroPure pressure vessel
1J = 1000 liter FluoroPure PE IBC
28 = 5 gallon FluoroPure PFA lined pail
29 = 55 gallon FluoroPure HDPE drum
49 = 500 liter FluoroPure PE or PFA IBC
50 = 800 liter FluoroPure PE or PFA IBC
51 = 1200 liter FluoroPure PE or PFA IBC
53 = 175 liter FluoroPure PE/PE or PE/PFA composite drum
66 = 500 liter FluoroPure PE high-pressure IBC
67 = 800 liter FluoroPure PE high-pressure IBC
68 = 1200 liter FluoroPure PE high-pressure IBC
XX = Contact the factory for additional assignments

Number of Ports
3 = Standard
4 = Includes recirculation diffuser

Material of Construction
P = Polyethylene
T = PFA

Model
DI3 = QCIII drum insert

Entegris, Inc.

Sentry QCIII Quick Connect System

Ordering Information
FluoroPure Dispense Heads
Part Number

DH3

Special Instructions
Nut Material
1 = PVDF
3 = PFA
6 = CPFA

Length of Tubing (Feet)


to be Attached to Head

00 = Standard
01 = Dispense port without
check valve
02 = Recirculation port without
check valve
03 = No check valve in
either dispense port
or recirculation port

00 = No tubing to be supplied

O-ring Material
0 = FEP encapsulated silicone
1 = FEP encapsulated Viton
2 = FEP encapsulated EPDM

Chemical Key Code


Reference the Fluid Handling Systems
catalog for chemical codes.

Number of Ports
3 = Standard
4 = Includes recirculation

Model
DH3 = QCIII drum insert
Note: Part number DH3X XX X 00 XXX would be a dispense head with no tubing supplied.
When this is requested, the dispense head will be shipped with the splashguard assembly.

FluoroPure Dispense HeadsLife Science


Part Number

0 1 - 1 0 1 9 8 9 4 - Chemical Key Code


Number of Ports

Reference the Fluid Handling Systems


catalog for chemical codes.

3 = Standard
4 = Includes recirculation
Note:
Standard options include:
- FEP encapsulated silicon o-ring
- PFA nut material
- No tubing
Please contact Entegris if other options are necessary.

Entegris, Inc.

For More Information


Please call your Regional Customer Service
Center today to learn what Entegris can do
for you. Visit www.entegris.com and select the
Customer Service link for the center nearest you.

Terms and Conditions of Sale


All purchases are subject to Entegris Terms
and Conditions of Sale. To view and print
this information, visit www.entegris.com and
select the Legal Notices link from the footer.

Entegris, the Entegris Rings Design, Flaretek, FluoroPure and Sentry are registered trademarks of Entegris, Inc.
Viton and Kalrez are registered trademarks of DuPont Dow Elastomers, L.L.C.

ENTEGRIS, INC.
Corporate Headquarters | 129 Concord Road | Billerica, MA 01821 USA
Customer Service Tel. +1 952 556 4181 | Customer Service Fax +1 952 556 8022
In North America 800 394 4083 | www.entegris.com

20062013 Entegris, Inc.

All rights reserved

Printed in USA

3560-2438ENT-0113

You might also like