AP 1120
Siemens
AP 1120
Contents
1
1.1
1.2
1.3
1.4
AP 1120. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Feature description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Indicators and connectors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
AMO usage in the HiPath 4000 V2.0. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Settings in the AP 1120 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
1.4.1
Checking the loaded AP 1120 software . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
1.4.1.1 With DHCP resp. known IP-Address . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
1.4.1.2 Without DHCP for the first installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
1.4.2
Preparation for Loading AP 1120 Software (Flashing) . . . . . . . . . . . . . . . . . 12
1.4.2.1 Loading with DHCP function . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
1.4.2.2 Loading the AP without DHCP function . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23
1.4.3
Settings of the HiPath 4000 V2.0 data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37
1.4.4
General actions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 41
EN0000DE00EN_0000
2005 Siemens AG
Siemens
AP 1120
EN0000DE00EN_0000
2005 Siemens AG
AP 1120
Siemens
AP 1120
1.1
Feature description
The AP 1120 supports the connection of Group 3 Fax devices, analog Modems and voice terminals via IP. The installation is done via the board STMI2 (Q2316-X / - X10) as HG3530 (FCTID=3) in the HiPath 4000 V2.0. It is also possible to use the AP 1120 on a HiPath 3000 with
H323v3 and SIP. In the HiPath 4000 V2.0 the Codec G.711 is supported. The AP 1120 is administered with the Tool Unit Management Network (UMN). All settings, which are necessary for the HiPath 4000 V2.0, and Software-Updates have to be done by this UMN-Tool.
1.2
Indicators and connectors
Ready
(green)
In Use
(orange)
LAN
(green)
Power
(green)
Ready: Is ON, if the AP 1120 is registered at the HG3550 (PABX-Address and Subscriber number must be set).
In Use: Is ON, if one of the two device ports are busy (Port 1 or/and Port 2).
LAN: Is ON (or blinking), if there is a connection to the IP network (Layer 1).
Power: Is ON, if the AP 1120 is supplied by the power-supply.
EN0000DE00EN_0000
2005 Siemens AG
AP 1120
Siemens
Analog connectors Default setting
(Port 1 left, Port 2 Button
right)
Computer
Network
Power
nector
con-
Analog connector: G3 Fax devices resp. analog Modems can be connected.
Default
Setting
Button
Pressed for:
Action
Comments
LEDs
Pattern
Ready
In Use
LAN
Power
Off
Off
Off
Blink
2 to 5
seconds
AP 1120
reboot
No changes are
made to the AP
1120 settings.
5 to 10
seconds
AP 1120
reboot in
Recovery
Mode
Sets the AP 1120 Blink
IP address to its
default value in the
MIB and restarts
the unit.
Blink
Blink
Blink
10 to 15
seconds
AP 1120
reboot in
Factory Reset Mode
Deletes the persis- On
tent MIB values,
creates a new configuration file with
the default factory
values, then restarts the unit.
On
On
On
EN0000DE00EN_0000
2005 Siemens AG
AP 1120
Siemens
Computer: A 10/100 BaseT Ethernet RJ-45 connector that can be connected into the network card of a computer. In this case, the HiPath AP1120 acts as a small Ethernet switch. It is possible to use either a cross-over or straight Ethernet cable to
connect in the Computer connector. The Computer connector performs automatic MDI / MDIX detection, meaning that it adapts to the type of cable connected
to it.
Network: A 10/100 BaseT Ethernet RJ-45 connector for access to a LAN, WAN or computer. It can also be used as remote power feeding and is IEEE 802.3af compliant
and Power DSine certified. It is possible to use either a cross-over or straight
Ethernet cable to connect in the Network connector. The Network connector performs automatic MDI / MDIX detection, meaning that it adapts to the type of cable
connected to it.
1.3
AMO usage in the HiPath 4000 V2.0
Check resp. add the number of HG3530- boards
DISPLAY-DIMSU:TYPE=SYSTEM;
ADD-DIMSU:TYPE=SYSTEM,STMIHFA2=10;
Add the STMIHFA2 board
ADD-BCSU:MTYPE=PER,LTU=1,SLOT=6,PARTNO=Q2316-X,FCTID=3;
Set the STMIHFA2 board data
ADD-HFAB:MTYPE=STMIHFA2,LTU=1,SLOT=6,SMODE=NORMAL,IPADDR=1.30.11.40,
NETMASK=255.255.255.0;
Add subscriber G3-Fax / Voice terminal / Modem
ADD-COSSU:NEWCOS=41,INFO="41 NON VOICE DEVICE";
CHANGE-COSSU:TYPE=COS,COS=41,
AVCE=TA&TNOTCR&CDRSTN&CDRINT&RKOABS&COSXCD&TTT;
CHANGE-COSSU:TYPE=COS,COS=41,AFAX=TA&TNOTCR&BASIC&MSN&MULTRA;
CHANGE-COSSU:TYPE=COS,COS=41,ADTE=TA&TNOTCR&BASIC&MSN&MULTRA;
ADD-SBCSU:STNO=2425,OPT=OPTI,CONN=IP2,PEN=1-1-6-10,DVCFIG=OPTIIP&ANAFAX
or ANADTE,COS1=41,COS2=41,LCOSV1=11,LCOSV2=11,LCOSD1=11,LCOSD2=11,
DPLN=0,ITR=0,SSTNO=N,SPDI=0,SECR=N,INS=Y,ALARMNO=8,CALLOG=NONE;
ANAFAX for G3 Fax device or Voice terminal
ANADTE for Modem
EN0000DE00EN_0000
2005 Siemens AG
AP 1120
Siemens
1.4
Settings in the AP 1120
1.4.1
Checking the loaded AP 1120 software
The AP 1120 must be loaded with the CorNet-IP software. If the AP 1120 is not loaded with the right software, a flash action is necessary (see Loading AP 1120 Software (Flashing)). For flashing an AP1120 the Tool UMN and a TFTP software is
necessary on the Admin-PC.
Start Unit Management Network (UMN) and connect with the Unit Manager.
Password:
8749H323
1.4.1.1
With DHCP resp. known IP-Address
Device scanning
EN0000DE00EN_0000
2005 Siemens AG
AP 1120
Siemens
Enter IP-Address range and start the scan
operation.
Select AP 1120
EN0000DE00EN_0000
2005 Siemens AG
AP 1120
Siemens
Select the AP 1120 and check the loaded software.
1.4.1.2
Without DHCP for the first installation
The Default IP-Address of the AP 1120 is 192.168.0.1.
Connect the AP 1120 with the Admin-PC
Connect the AP 1120, Port COMPUTER, with the Admin-PC directly (straight or crossed
over cable can be used). Change the IP-Address of your PC, e.g. to 192.168.0.20 with Subnet-Maske 255.255.255.0.
EN0000DE00EN_0000
2005 Siemens AG
AP 1120
Siemens
Set the AP 1120 IP-Address to Default
Start a Reboot in Recovery Mode . To do this, press and hold the Default Setting
Button between 5 and 10 seconds, until all LEDs start blinking.
Device scanning
EN0000DE00EN_0000
2005 Siemens AG
AP 1120
Siemens
Enter
IP-Address
192.168.0.1 and start
scan operation.
Select AP 1120
10
EN0000DE00EN_0000
2005 Siemens AG
AP 1120
Siemens
Select AP 1120 and check the loaded Software.
EN0000DE00EN_0000
2005 Siemens AG
11
AP 1120
Siemens
1.4.2
Preparation for Loading AP 1120 Software (Flashing)
The Tool Unit Management Network (UMN) must be installed on the Admin-PC.
The directory-/file-structure of the TFTP-Server (PC):
If an AP 1120 is changed from H323 resp. SIP to CorNet-IP the loaded software
(H323 / SIP) is downloaded again before the CorNet-IP-Software can be transfered.
If it is an Upgrade of a CorNet-IP version to a newer one the download of the same
software is not necessary. After a Software change from H323/SIP to CorNet-IP a
Factory Reset must be executed !!!
Only an AP 1120 with Software H323 v4 can be migrated to CorNet-IP v1 !!!
12
EN0000DE00EN_0000
2005 Siemens AG
AP 1120
1.4.2.1
Siemens
Loading with DHCP function
Start Unit Management Network (UMN) and connect with the Unit Manager.
Password:
8749H323
Device scanning
EN0000DE00EN_0000
2005 Siemens AG
13
AP 1120
Siemens
Enter IP-Address range and start the scan
operation.
Control the scanning
time for the single IPAddresses.
Select AP 1120
14
EN0000DE00EN_0000
2005 Siemens AG
AP 1120
Siemens
Configure the Software Download Server
Right mouse key
EN0000DE00EN_0000
2005 Siemens AG
15
Siemens
AP 1120
The IP-Address of the
TFTP-Servers (PC):
1.30.21.2
Enter the directory of
the new Software.
16
EN0000DE00EN_0000
2005 Siemens AG
AP 1120
Siemens
Start the TFTP-Server (in this example: 3cDaemon)
Configure the TFTPServer
EN0000DE00EN_0000
2005 Siemens AG
17
AP 1120
Siemens
Start Software Download
Process: Click with the right mouse key on the AP and select Download Software
(Abrupt);
Select AP
18
EN0000DE00EN_0000
2005 Siemens AG
AP 1120
Siemens
The Software is transfered to the AP 1120
EN0000DE00EN_0000
2005 Siemens AG
19
Siemens
AP 1120
Display the status of the Download-process
Right mouse key;
selectEdit SNMP;
If there was a Software change from H323/SIP to CorNet-IP, a Factory Reset has
to be started (see Indicators and connectors) !!!
20
EN0000DE00EN_0000
2005 Siemens AG
AP 1120
Siemens
Delete the AP 1120 from the Unit Manager
Scan the AP 1120 again
Start device scanning
Enter IP address range and start the scan
operation.
Select the AP 1120
EN0000DE00EN_0000
2005 Siemens AG
21
AP 1120
Siemens
Check the Software version
Select the AP 1120 and check the loaded Software.
22
EN0000DE00EN_0000
2005 Siemens AG
AP 1120
Siemens
0.0.0.1
Loading the AP without DHCP function
The default IP-Address of the AP 1120 is 192.168.0.1.
Connect the AP 1120 with the Admin-PC
Connect the AP1120 with the Admin-PC directly (straight or crossed over cable is possible). Change the IP-Address of the Admin-PC, e.g. to 192.168.0.20 with Subnet mask
255.255.255.0.
Set the AP 1120 IP-Address to Default
Start a Reboot in Recovery Mode. To do this, press the Default Setting Button
between 5 to10 seconds, until all LEDs start to blink.
Start the Unit Management Network (UMN) and connect to the Unit Manager.
Password:
8749H323
Device scanning
EN0000DE00EN_0000
2005 Siemens AG
23
AP 1120
Siemens
Enter
IP-Adresse
192.168.0.1 and start
scanning operation.
Select AP 1120
24
EN0000DE00EN_0000
2005 Siemens AG
AP 1120
Siemens
Select AP 1120 and check the loaded Software.
EN0000DE00EN_0000
2005 Siemens AG
25
Siemens
AP 1120
Change the AP 1120 settings
IP-Address of the
TFTP-Server (PC) is:
1.30.21.2
Enter the directory of
the new Software.
26
EN0000DE00EN_0000
2005 Siemens AG
AP 1120
Siemens
AP 1120 Restart
Process: Click with the right mouse key on the AP, which you want to restart, and select
Restart (Abrupt) or Restart (Graceful);
Select AP
EN0000DE00EN_0000
2005 Siemens AG
27
Siemens
AP 1120
Connect the AP 1120 to the customer LAN (Port NETWORK) and change the IPAddress of the Admin-PC Network card !!!
28
Delete the AP 1120
EN0000DE00EN_0000
2005 Siemens AG
AP 1120
Siemens
Device scanning
Enter IP-Address range and start the scan
operation.
Control the scanning
time of the single IPAddresses.
EN0000DE00EN_0000
2005 Siemens AG
29
AP 1120
Siemens
Select AP 1120
30
EN0000DE00EN_0000
2005 Siemens AG
AP 1120
Siemens
Start the TFTP-Server (in this example: 3cDaemon)
Configure the TFTPServer
EN0000DE00EN_0000
2005 Siemens AG
31
AP 1120
Siemens
Start the Software Download
Process: Click with the right mouse key on the AP and select Download Software
(Abrupt);;
Select AP
32
EN0000DE00EN_0000
2005 Siemens AG
Siemens
Software is transfered to the AP 1120
EN0000DE00EN_0000
2005 Siemens AG
33
Siemens
AP 1120
Display the Status of the Download operation
Right mouse key;
select Edit SNMP;
If there was a Software change from H323/SIP to CorNet-IP, a Factory Reset has
to be started (see Indicators and connectors) !!!
34
EN0000DE00EN_0000
2005 Siemens AG
AP 1120
Siemens
Delete the AP 1120
Scan the devices again
Start the device scanning
Enter the IP-Address
range and start the
scan operation.
Select the AP 1120
EN0000DE00EN_0000
2005 Siemens AG
35
AP 1120
Siemens
Check the Software version
Select the AP 1120 and check the loaded Software.
36
EN0000DE00EN_0000
2005 Siemens AG
AP 1120
0.0.1
Siemens
Settings of the HiPath 4000 V2.0 data
Set Host-IP (STMI2 address)
Enter IP addresse of the
STMI2 board (HG3530)
Enter subscriber number
EN0000DE00EN_0000
2005 Siemens AG
37
Siemens
38
AP 1120
EN0000DE00EN_0000
2005 Siemens AG
AP 1120
Siemens
Set Port data
Europe: a-Law
USA: u_Law
EN0000DE00EN_0000
2005 Siemens AG
39
Siemens
AP 1120
Restart the AP 1120
Process: Click with the right mouse key on the AP, which you want to restart, and select
Restart (Abrupt);
40
EN0000DE00EN_0000
2005 Siemens AG
AP 1120
0.0.2
Siemens
General actions
AP 1120 Restart
Process: Click with the right mouse key on the AP, which you want to restart, and select
Restart (Abrupt) or Restart (Graceful);
EN0000DE00EN_0000
2005 Siemens AG
41
Siemens
AP 1120
Backup the AP 1120 data
To backup the AP 1120 data, a file with the name MacXXXXXX.cfg is created on the
Admin-PC (Upload). This file can be restored during trouble shooting or AP 1120
change (Download). So the AP 1120 has not be configured again in case of error.
42
EN0000DE00EN_0000
2005 Siemens AG
AP 1120
EN0000DE00EN_0000
2005 Siemens AG
Siemens
43
Siemens
44
AP 1120
Restore AP 1120 data
EN0000DE00EN_0000
2005 Siemens AG