Orion-Tr DC-DC converters isolated: 100 Watt series
www.victronenergy.com
Remote on-off
The remote on-off eliminates the need for a high current switch in the input wiring. The
remote on-off can be operated with a low power switch or by for example the engine
run/stop switch (see manual).
Adjustable output voltage: can also be used as a battery charger
For example to charge a 12 Volt starter or accessory battery in an otherwise 24 V system.
Orion-Tr 12/24-5 (120W)
All models are short circuit proof and can be paralleled to increase output current
An unlimited number of units can be connected in parallel.
IP43 protection
When installed with the screw terminals oriented downwards
Screw terminals
No special tools needed for installation
Orion-Tr 12/24-5 (120W)
Input fuse
On 12V and 24V input models only
Isolated converters
Input voltage range
Under voltage shut down
Orion-Tr
12/12-9
(110 W)
8-17V
Orion-Tr
12/24-5
(120 W)
8-17 V
Orion-Tr
24/12-9
(110 W)
16-35 V
Orion-Tr
24/24-5
(120 W)
16-35 V
14 V
Orion-Tr
24/48-2,5
(120 W)
16-35 V
14 V
Orion-Tr
48/12-9
(110 W)
32-70 V
28 V
Orion-Tr
48/24-5
(120 W)
32-70 V
28 V
Orion-Tr
48/48-2,5
(120 W)
32-70 V
28 V
7V
7V
14 V
Under voltage restart
7,5 V
7,5 V
15 V
15 V
15 V
30 V
30 V
30 V
Nominal output voltage
12,2 V
24,2 V
12,2 V
24,2 V
48,2 V
30-60 V
12,2 V
10-15 V
24,2 V
20-30 V
48,2 V
30-60 V
Output voltage adjust range
10-15 V
20-30 V
10-15 V
20-30 V
Output voltage tolerance
+/- 0,2 V
+/- 0,2 V
+/- 0,2 V
+/- 0,2 V
+/- 0,2 V
+/- 0,2 V
+/- 0,2 V
+/- 0,2 V
Output noise
Cont. output current at nominal
output voltage and 25C
Maximum output current (10 s)
at nominal output voltage
Short circuit output current
2 mV rms
2 mV rms
2 mV rms
2 mV rms
2 mV rms
2 mV rms
2 mV rms
2 mV rms
9A
5A
9A
5A
2,5 A
9A
5A
2,5 A
12,5 A
6,3 A
12,5 A
6,3 A
3,0 A
12,5 A
6,3 A
3,0 A
30 A
19 A
27 A
25 A
17 A
110 W
120 W
120 W
32 A
23 A
39 A
Cont. output power at 25C
110 W
120 W
110 W
120 W
120 W
Cont. output power at 40C
85 W
110 W
85 W
115 W
115 W
85 W
100 W
85 W
Efficiency
Galvanic isolation
Operating temperature range
Humidity
DC connection
Maximum cable cross-section
87%
88%
85%
87%
88%
87%
86%
89%
Weight
Dimensions hxwxd
Standards: Safety
Emission
Immunity
Automotive Directive
Victron Energy B.V. | De Paal 35 | 1351 JG Almere | The Netherlands
General phone: +31 (0)36 535 97 00 | Fax: +31 (0)36 535 97 40
E-mail:
[email protected] | www.victronenergy.com
200 V dc between input, output and case
-20 to +55C (derate 3% per C above 40C)
Max. 95% non condensing
Screw terminals
6 mm AWG10
0,42 kg
100 x 113 x 47 mm
EN 60950
EN 61000-6-3, EN 55014-1
EN 61000-6-2, EN 61000-6-1, EN 55014-2
EN 50498
Orion-Tr DC-DC converters
www.victronenergy.com
Non-isolated
High efficiency
Using synchronous rectification, full load efficiency exceeds 95%.
IP43 protection
When installed with the screw terminals oriented downwards
Screw terminals
No special tools needed for installation
Orion-Tr 24/12-5 (60W)
Orion-Tr 24/12-10 (120W)
Non isolated
converters
Orion-Tr
24/12-5
Orion-Tr
24/12-10
Orion-Tr
24/12-15
Orion-Tr
24/12-20
Input voltage range
18-35 V
18-35 V
18-35 V
18-35 V
12.7 V
12.5 V
12.5 V
12.5 V
Efficiency
95%
97%
97%
97%
Continuous output current
5A
10 A
15 A
20 A
Max. Output current
7A
12 A
20 A
25 A
Galvanic isolation
no
no
no
no
< 20 mA
< 45 mA
< 35 mA
< 35 mA
Output voltage
Off load current
Operating temperature range
(derate 3% per C above 40C)
-20 to +55C
DC connection
Maximum cable cross-section
Weight kg
(lbs)
Dimensions hxwxd in mm
(hxwxd in inches)
Standards: Safety
Emission
Immunity
Automotive Directive
Victron Energy B.V. | De Paal 35 | 1351 JG Almere | The Netherlands
General phone: +31 (0)36 535 97 00 | Fax: +31 (0)36 535 97 40
E-mail:
[email protected] | www.victronenergy.com
Screw terminals
3,3 mm
AWG12
6 mm
AWG10
6 mm
AWG10
6 mm
AWG10
0,09
(0.20)
0,2
(0.44)
0,25
(0.55)
0,25
(0.55)
53x51x27
(2.1x2x1.1)
73x94x37
(2.9x3.7x1.5)
73x94x45
(2.9x3.7x1.8)
73x94x45
(2.9x3.7x1.8)
EN 60950
EN 61000-6-3, EN 55014-1
EN 61000-6-2, EN 61000-6-1, EN 55014-2
EN 50498