Stirred Liquid Baths
Hydra 798
-80 to 300C
Four Models, -80C to 300C
Stability 0.01C
Excellent Uniformity
Precision calibration of thermometers calls for the use of
stirred liquid calibration baths. The Hydra models set new
standards in terms of price to performance ratio. Now
Calibration Engineers and Metrologists can choose from
a range of baths that offer good immersion depth, parallel
tube action, giving the best uniformity and smallest
calibration uncertainties, and wide temperature ranges.
Hydra offers these features in a new price class, dont
settle for a bath with shallow immersion or simple stirred
action when with these Isotech baths provide good depth
of immersion and good temperature uniformity along with
the other benefits Isotech baths offer.
The immersion depth of 300mm allows the requirements
of Supplementary Information to the ITS-90 to be met.
This publication from BIPM recommends immersion
depths of 15 to 20cm from -50C to 50C, and from 20 to
27cm at 200C. Many baths in this price range are simply
not deep enough to meet this requirement. Rather than
simply stirring a square tank of liquid the Hydra uses
parallel tube action for superior temperature uniformity.
Like other Isotech liquid baths the calibration volume is
cylindrical to suit thermometers, not a large square tank.
The bath is filled with just 5 litres of liquid reducing filling
and ongoing cost of ownership as liquids are replenished.
The 798H and 798EHT feature a cooling coil which can
be attached to an external source of either cold water or
gas to further reduce cool down times.
Hydra benefits from Isotechs experience, it drains faster,
is easier to use, is safer, and is more convenient.
Accessories allow a wide range of thermometers, for
example, to be readily clamped by the Sensor Support
and ITS-90 fixed points cells are accommodated with the
adjustable cell holder.
g Parallel
g Cooling...
g Commercial
Liquid flows up the rear volume of the
bath and down the working volume.
This action creates very small vertical
and axial gradients. This gives the
smallest overall uncertainties.
The cooling is built-in and also
surrounds the calibration volume
creating a low temperature ambient in
which the heater can function
efficiently.
The chillers are one third horse power
commercial grade units, not cheaper
domestic grade as used by some
manufacturers.
g Heating...
g Wider
All heating is outside the container. By
using a large area nickel foil heater the
complete bath wall is heated uniformly.
A unique cooling system cools the
unit as well as enabling the bath to
heat up to 125C (121C is a key
sterilization temperature).
Double the depth of some baths. The
Hydra Range has up to 300mm depth
of immersion.
g Fast
Tube Action...
Cool Down...
The Hydra cools from ambient to
-80C in just 180 minutes.
68
SOLUTIONS FOR PRIMARY & SECONDARY LABORATORIES
Temperature Range...
g Calibration
g Circular
Grade Chillers...
Depth...
Design...
The circular design eliminates cold
corners found in tank shaped
calibration baths.
SET / RESET
POWER
CONTROLLER
OVER-TEMPERATURE
SET / RESET
POWER
CONTROLLER
OVER-TEMPERATURE
Over
Temperature
Controller
Temperature
Controller
Power
Set / Reset
Calibration
Volume
Overflow
Drain
Cooling
(798H and
798EHT only)
Model
Temp Range
798L
798M
-80C 125C
-40C 125C
Volume
798H
798EHT
30C 200C
30C 300C
150mm Diameter, 300mm Deep (5 litres)
Absolute Stability
0.030C
(Methanol, -80C)
Vertical Uniformity
0.002C
(Oil, 50C)
0.017C
(Methanol, -40C)
0.015C
(Oil, 125C)
0.015C
(Oil, 250C)
0.002C
(Oil, 50C)
0.002C
(Oil, 125C)
0.005C
(Oil, 200C)
Heating time
25C to 200C < 60 minutes (C10 Oil)
Cooling time
Ambient to -80C < 130minutes (Methanol)
Communications
Dimensions
Weight
Includes Serial Interface, PC Cable and Software
405mm Wide, 610mm Deep, 940mm High (870mm to Top Panel)
59kg
Safety
Power
How to Order
46kg
33kg
33kg
Compliant to CE Regulations
2.5kW
110V 50/60Hz or
230V 50/60Hz
798L
1.5kW
800W
110V 50/60Hz or 110V 50/60Hz or
230V 50/60Hz 230V 50/60Hz
798M
798H
800W
110V 50/60Hz or
230V 50/60Hz
798EHT
Refer to Evaluation Report for Full Details
SOLUTIONS FOR PRIMARY & SECONDARY LABORATORIES
69
Heat Up Graph
125C
100C
100C
75C
75C
50C
50C
TEMPERATURE (C)
TEMPERATURE (C)
Cool Down Graph
125C
25C
0C
-25C
25C
0C
-25C
-50C
-50C
-75C
-75C
-100C
-100C
0
30
60
90
120
TIME (minutes)
150
180
Calibration
Area
20
40
60
80
TIME (minutes)
100
120
100mm
150mm
Accesories - Refer to Liquid Selection Guide on page 73 for information on liquids and important Health and Safety Information
Lid
Equalizing Block
798-05-01
798-05-02A
798-05-02B
798-05-02C
798-05-02D
Dual Cell Holder
70
798-05-03
Liquid Volume Lid
Included
Sensor Holder
Aluminium Equalizing
Block, 4 pockets,
8mm diameter,
160mm deep
Copper Equalizing
Block, 4 pockets,
8mm diameter,
160mm deep
Special Aluminium
Equalizing Block
To suit customer
requirements.
Special Copper
Equalizing Block
To suit customer
requirements.
Fixed Point Cells
Standard Dual
Cell Holder
Includes
interchangeable
Cell adaptors
SOLUTIONS FOR PRIMARY & SECONDARY LABORATORIES
798-05-04
Thermometer
Support Kit
Holds up to 12 sensors
between 3mm diameter
and 8mm diameter
17724
Mercury
Triple Point Cell
-38.8344C
B12
Water
Triple Point Cell
0.01C
17401
Gallium
Melt Point Cell
29.7646C
17401M
Slim Gallium
Melt Point Cell
29.7646C
17668ML
Indium
Freeze Point Cell
156.5985C