0% found this document useful (0 votes)
2K views14 pages

Digiplex 848 Quick Programming Guide v4 1

This document provides a quick programming guide for the Digiplex DGP848 security panel. It includes the following information: - An overview of the panel's zone configuration capabilities, including 8 on-board zones, support for up to 48 total zones through the use of hardwired and wireless expanders, and 2 keypad zones. - Details on how to program the zone numbering, zone types, partitions, and options through the panel's programming mode in order to properly configure the various zones and sensors. - A sample programming sequence showing how to program the zones for a sample configuration involving the panel's on-board zones, a keypad zone, an 8-zone hardwired expander,

Uploaded by

Alex
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
2K views14 pages

Digiplex 848 Quick Programming Guide v4 1

This document provides a quick programming guide for the Digiplex DGP848 security panel. It includes the following information: - An overview of the panel's zone configuration capabilities, including 8 on-board zones, support for up to 48 total zones through the use of hardwired and wireless expanders, and 2 keypad zones. - Details on how to program the zone numbering, zone types, partitions, and options through the panel's programming mode in order to properly configure the various zones and sensors. - A sample programming sequence showing how to program the zones for a sample configuration involving the panel's on-board zones, a keypad zone, an 8-zone hardwired expander,

Uploaded by

Alex
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 14

Digiplex Quick Programming Guide DGP848 (V4.

00)
SECTION A: Product information
* Zone configuration
Model
DGP-848

On board zone
8 zones

Keypad zone
2 zones

Expander
Hardwire

APR3-ZX 4 Four (4) zone hardwire


APR3-ZX 8 Eight (8) zone hardwire
DGP2-50 Addressable PIR (Dual element)
DGP2-60 Addressable PIR (Quad element)
DGP2-70 Addressable Pet immunity PIR
Wireless

MG-RCV3 Magellan wireless receiver


MG-DCT1 Door transmitter
MG-PMD1P Pet immunity PIR (dual element)
MG-PMD75 Pet immunity PIR (Dual-Optic)
MG-PMD85 OUTDOOR Pet immunity PIR
Note: Any combination either hardwire or/and wireless
up to 48 zones

* System modules
DGP848

8 zones

Hardwire zone

APR3-ZX 4
APR3-ZX 8

4 zones
8 zones

Addressable zone

DGP2-50 Addressable PIR (Dual element)


DGP2-60 Addressable PIR (Quad element)
DGP2-70 Addressable Pet immunity PIR

1 zone
1 zone
1zone

Wireless zone

MG-RCV3 Magellan wireless receiver (up to 16 transmitters)


MG-DCT1 Door transmitter
MG-PMD1P Pet immunity PIR (dual element)
MG-PMD75 Pet immunity PIR (Dual-Optic)
MG-PMD85 OUTDOOR Pet immunity PIR

1 zone
1 zone
1 zone
1 zone

Keypad
DGP2-641 LCD (supply with panel)
DGP-648 LED 48 zones
Accessories
APR3-ADM2 In touch voice arm/disarm module
APR3-PRT1 Printer module
APR3-PGM1 One PGM expansion module
APR3-PGM4 Four PGM expansion module
DGP2-ACM1P Access control module

*System features
Features

8 zone on board, expandable to 48 zones (in any combination up to 95 number of modules)


4 partitions
96 user codes
1024 events log
Expandable to 125 PGM outputs
Access control up to 32 doors
4 wires bus for all modules supports up to 95 numbers of modules and connects modules up to 3000ft
(18AWG) / 1000ft (22AWG) from the panel.
2 on-board PGM expandable up to 125
1.1A for Aux. power
Supervise bell output
Telephone line monitoring
Hourly test transmission
Call up to 4 phones
Arm/disarm and control PGM via phone

Specifications
Maximum Aux power 700mA [DGP-641keypad is 60 mA per unit, APR3-ZX4 is 20 mA, APR3-ZX8 is 40mA,
addressable PIR is 16 mA]
Wire gauge refers to PAGE 42 of Original Programming Guide

SECTION B: Programming
To enter Programming Mode:
1.
2.
3.
4.

Press and hold the[0] key


Enter [000000], you are in the programming mode
Enter 3 digits SECTION number
Enter required DATA (Either enter 2 digits, 3 digits or ON / OFF relevant key)
Press [ENTER] to confirm or [CLEAR] to ignore

For value [0] to [9], choose key [0] to [9]. For value [A] is [STAY] key, value [B] is [FORCE] key,
value [C] is [ARM] key, value [D] is [DISARM] key, value [E] is [BYP] key & value [F] is [MEM] key.
Remember: After keyed in a required DATA, always press ENTER and CLEAR, in order to let the ENTER key
flashing before proceed with entering the next 3 digits SECTION number.

Example: The main board is 8 zones, one keypad zone, one 8 zone expander (ZX8) & 2 pcs
of PIR.
Note: All zones can be assigned to any desired zone number.

MUST do step 1 ,2 & 3, or else zone is DISABLE

Step 1 Zone Numbering


Press & hold [0], then enter [000000], you are in the programming mode
Main board:
Press section [001], enter [8 digit S/N, then 3 digit input], means 8 digits is the main board s/n, and key in 001.
Press section [002], enter [8 digit S/N, then 3 digit input], means 8 digits is the main board s/n, and key in 002.
Press section [003], enter [8 digit S/N, then 3 digit input], means 8 digits is the main board s/n, and key in 003.
Press section [004], enter [8 digit S/N, then 3 digit input], means 8 digits is the main board s/n, and key in 004.
Press section [005], enter [8 digit S/N, then 3 digit input], means 8 digits is the main board s/n, and key in 005.
Press section [006], enter [8 digit S/N, then 3 digit input], means 8 digits is the main board s/n, and key in 006.
Press section [007], enter [8 digit S/N, then 3 digit input], means 8 digits is the main board s/n, and key in 007.
Press section [008], enter [8 digit S/N, then 3 digit input], means 8 digits is the main board s/n, and key in 008.
Keypad:
Press section [009], enter [8 digit S/N], means 8 digits is the keypad s/n, and key in 009.
8 zones Expander board:
Press section [010], enter [8 digit S/N, then 3 digit input], means 8 digits is the expander board s/n, and key in 001.
Press section [011], enter [8 digit S/N, then 3 digit input], means 8 digits is the expander board s/n, and key in 002.
Press section [012], enter [8 digit S/N, then 3 digit input], means 8 digits is the expander board s/n, and key in 003.
Press section [013], enter [8 digit S/N, then 3 digit input], means 8 digits is the expander board s/n, and key in 004.
Press section [014], enter [8 digit S/N, then 3 digit input], means 8 digits is the expander board s/n, and key in 005.
Press section [015], enter [8 digit S/N, then 3 digit input], means 8 digits is the expander board s/n, and key in 006.
Press section [016], enter [8 digit S/N, then 3 digit input], means 8 digits is the expander board s/n, and key in 007.
Press section [017], enter [8 digit S/N, then 3 digit input], means 8 digits is the expander board s/n, and key in 008.
PIR:
Press section [018], enter [8 digit S/N], means 8 digits is the PIR s/n.
Press section [019], enter [8 digit S/N], means 8 digits is the PIR s/n.
8 zones Expander board:
Press section [020], enter [8 digit S/N, then 3 digit input], means 8 digits is the expander board s/n, and key in 001.
Press section [021], enter [8 digit S/N, then 3 digit input], means 8 digits is the expander board s/n, and key in 002.
Press section [022], enter [8 digit S/N, then 3 digit input], means 8 digits is the expander board s/n, and key in 003.
Press section [023], enter [8 digit S/N, then 3 digit input], means 8 digits is the expander board s/n, and key in 004.
Press section [024], enter [8 digit S/N, then 3 digit input], means 8 digits is the expander board s/n, and key in 005.
Press section [025], enter [8 digit S/N, then 3 digit input], means 8 digits is the expander board s/n, and key in 006.
Press section [026], enter [8 digit S/N, then 3 digit input], means 8 digits is the expander board s/n, and key in 007.
Press section [027], enter [8 digit S/N, then 3 digit input], means 8 digits is the expander board s/n, and key in 008.
16 zones Wireless Receiver:
Press section [028], enter [8 digit S/N, then 3 digit input], means 8 digits is the Receiver S/N, and key in 001.
Press section [029], enter [8 digit S/N, then 3 digit input], means 8 digits is the Receiver S/N, and key in 002.
Press section [030], enter [8 digit S/N, then 3 digit input], means 8 digits is the Receiver S/N, and key in 003.
Press section [031], enter [8 digit S/N, then 3 digit input], means 8 digits is the Receiver S/N, and key in 004.
Press section [032], enter [8 digit S/N, then 3 digit input], means 8 digits is the Receiver S/N, and key in 005.
Press section [033], enter [8 digit S/N, then 3 digit input], means 8 digits is the Receiver S/N, and key in 006.
Press section [034], enter [8 digit S/N, then 3 digit input], means 8 digits is the Receiver S/N, and key in 007.
Press section [035], enter [8 digit S/N, then 3 digit input], means 8 digits is the Receiver S/N, and key in 008.
Press section [036], enter [8 digit S/N, then 3 digit input], means 8 digits is the Receiver S/N, and key in 009.
Press section [037], enter [8 digit S/N, then 3 digit input], means 8 digits is the Receiver S/N, and key in 010.
Press section [038], enter [8 digit S/N, then 3 digit input], means 8 digits is the Receiver S/N, and key in 011.
Press section [039], enter [8 digit S/N, then 3 digit input], means 8 digits is the Receiver S/N, and key in 012.
Press section [040], enter [8 digit S/N, then 3 digit input], means 8 digits is the Receiver S/N, and key in 013.
Press section [041], enter [8 digit S/N, then 3 digit input], means 8 digits is the Receiver S/N, and key in 014.
3

Press section [042], enter [8 digit S/N, then 3 digit input], means 8 digits is the Receiver S/N, and key in 015.
Press section [043], enter [8 digit S/N, then 3 digit input], means 8 digits is the Receiver S/N, and key in 016.
Note: Transmitter S/N program in Step 7 D

Step 2 Zone Type , Partition & Options


Press & hold [0], then enter [000000], you are in the programming mode
Press section [101], [6,1, ENTER], means ZONE 1 Instant, Partition 1.
Press section [102], [6,1, ENTER], means ZONE 2 Instant, Partition 1.
Press section [103], [6,1, ENTER], means ZONE 3 Instant, Partition 1.
Press section [104], [6,1, ENTER], means ZONE 4 Instant, Partition 1.
Press section [105], [6,1, ENTER], means ZONE 5 Instant, Partition 1.
Press section [106], [6,1, ENTER], means ZONE 6 Instant, Partition 1.
Press section [107], [6,1, ENTER], means ZONE 7 Instant, Partition 1.
Press section [108], [6,1, ENTER], means ZONE 8 Instant, Partition 1.
Press section [109], [1,1, ENTER], means ZONE 9 Delay, Partition 1.
Press section [110], [6,1, ENTER], means ZONE 10 Instant, Partition 1.
Press section [111], [6,1, ENTER], means ZONE 11 Instant, Partition 1.
Press section [112], [6,1, ENTER], means ZONE 12 Instant, Partition 1.
Press section [113], [6,1, ENTER], means ZONE 13 Instant, Partition 1.
Press section [114], [6,1, ENTER], means ZONE 14 Instant, Partition 1.
Press section [115], [6,1, ENTER], means ZONE 15 Instant, Partition 1.
And [116] for zone 16, [117] for zone 17, and so on .

Key in section
101 for zone 1
102 for zone 2
103 for zone 3
up to .
148 for zone 48

Zone type
0 for zone disable
1 for entry delay 1
5 for follow
6 for Instant
8 for 24 hour [panic]
A for fire[24 hour]

Partition
1 for partition 1
2 for partition 2
3 for partition 3
4 for partition 4

Zone options
1 for auto zone shutdown [default: OFF]
2 for Bypassable zone [default: ON]
3 for stay zone [default: OFF]
4 for force zone [default: OFF]
5 & 6 are OFF for audible zone [default]
5 ON & 6 OFF for silent zone
7 for intellizone [default: OFF]

Note 1:
The 1st digit represents by: 1 for Delay zone, 5 for Follow zone, 6 for Instant zone, 8 for 24 hour alarm.
Dont program keypad zones if not used.
Note 2:
If the zone wants to become a STAY zone, instead of [6,1,ENTER, CLEAR], replace it with
[6,1 and ON key 3, ENTER, CLEAR], means this zone will be bypassed when stay armed.
If the zone want to become a FORCE zone, instead of [6,1,ENTER, CLEAR]. Replace it with
[6,1,and ON key 4, ENTER, CLEAR], means this zone will be allowed open during arming.
Note 3:
By default, all zones are Bypassable.

Step 3 Enable EOL (end of line resistor)


Press & hold [0], then enter [000000], you are in the programming mode
Press section [504], [ON key 7], means used of EOL resistor on hardwire zone

Step 4 - Others essential basic features to be programmed


Press & hold [0], then enter [000000], you are in the programming mode

Fast zone for zones

Section 201, enter [002] for 40 ms for vibration sensor on zone 1


Section 202, enter [002] for 40 ms for vibration sensor on zone 2
Section 203, enter [002] for 40 ms for vibration sensor on zone 3
Section 204, enter [002] for 40 ms for vibration sensor on zone 4
Section 205, enter [002] for 40 ms for vibration sensor on zone 5
Section 206, enter [002] for 40 ms for vibration sensor on zone 6
Section 207, enter [002] for 40 ms for vibration sensor on zone 7
Section 208, enter [002] for 40 ms for vibration sensor on zone 8
And section 209 for zone 9 and so on

Section 226 for exit delay partition 1 (e.g.: enter [226], then key in [030] for 30 seconds). Default is 60 seconds

Section 230 for entry delay partition 1 (e.g.: enter [230], then key in [030] for 30 seconds). Default is 30
seconds

Section 234 for bell timer partiton 1 (e.g.: enter [234], then key in [010] for 10 minutes). Default is 4 minutes

Section 506, key for keypad Panic option wanted. (e.g:[ ON 1,2,3,4,5,6][ENTER][CLEAR] for audible panic
[1]&[3], [4]&[6], [7]&[9] )

Section 508, ON key for option wanted. For one-touch functions. (e.g: ON 1 for regular arming, ON 2 for stay
arming, ON 3 for instant arming & ON 4 for force arming) Note: Stay & force arming need to be programmed
in Step 2 for each individual zone.

* Choose either Step 5A or 5B

Step 5 A To call Handphone / Phone


Press & hold [0], then enter [000000], you are in the programming mode
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
11.
12.
13.
14.
15.

Section 521, ON key [3], (key 4 5 & 6 remain ON). To enable Dialer.
Section 524, ON key [1,2,3 & 4], for alarm reporting to telephone 1,2,3 & 4. Note: for partition 1
Section 550, enter [7777] for pager reporting format to dial tel. 1,2,3 & 4.
Section 551, enter [8888]. For account no. 1
Section 552, enter [8888]. For account no. 2
Section 553, enter [8888]. For account no. 3
Section 554, enter [8888]. For account no. 4
Section 561, enter phone no. 1 follow with codes (e.g.: 0121234567 BYP 88 BYP 88 BYP 88 BYP 88 BYP 88
BYP 88 BYP 888).
Section 562, enter phone no. 2 follow with codes (e.g.: 0121234567 BYP 88 BYP 88 BYP 88 BYP 88 BYP 88
BYP 88 BYP 888).
Section 563, enter phone no. 3 follow with codes (e.g.: 0121234567 BYP 88 BYP 88 BYP 88 BYP 88 BYP 88
BYP 88 BYP 888).
Section 564, enter phone no. 4 follow with codes (e.g.: 0121234567 BYP 88 BYP 88 BYP 88 BYP 88 BYP 88
BYP 88 BYP 888).
Section 655, enter 33333333. For alarm reporting codes zone 1 to 4.
Section 656, enter 33333333. For alarm reporting codes zone 5 to 8.
Section 657, enter 33333333. For alarm reporting codes zone 9 to 12.
Section 658, enter 33333333. For alarm reporting codes zone 13 to 16.

Call sequence: Tel 1, 2,3 and 4 each ONE time only

Step 5B - Link to Centre Monitoring Station (CMS)


Press & hold [0], then enter [000000], you are in the programming mode
Section
550
521
522
551
561
562
261
270
790

Contact I.D
[55]
ON key [3], (key 4, 5 & 6 remain ON)
ON key [6], alternative dial
Enter 4 digit account no 1
(Note: account with digit [0 = STAY] key
Enter phone no. 1 (e.g.: 12345678 [ENTER][CLEAR] )
Enter phone no. 2 (e.g.: 12345679 [ENTER][CLEAR] )
Enter [001] for daily auto test
Enter [HH:MM] for test time
Press [ENTER], for all reporting codes from section 600 to 718.

600 to 718

Do nothing

Step 6 PGM 1 (Programmable output)


Press & hold [0], then enter [000000], you are in the programming mode
Option 1

Section 400, enter 11 & ON key 1


Section 401, enter 11 & ON key 1

Arming in regular mode


(including stay, force, instant & keyswitch arming)

Option 2

Section 400, enter 11 & ON key 5


Section 401, enter 11 & ON key 5

Strobe

Option 3

Section 400, enter 44 & ON key 2


Section 401, enter 44 & ON key 2
Section 400, enter 21 & ON key 1
Section 401, enter 21 & ON key 1

Fail to communication on tel. 1

Option 4

Ready status

For more options, refer to System Programming Outputs Guide.


Wiring connection: POSITIVE leg of LED to AUX + and NEGATIVE leg of LED (with 1k resistor) to PGM. Note:
PGM only support 50mA, a Relay is needed if more than 50mA.

Step 7: Modules Programming Guide For expansion modules


To enter Programming Mode (it is advisable to use LCD to do this programming):
1.
2.
3.

Press and hold the [0] key


Enter [000000] (SECTION will be displayed on LCD keypad), you are in the programming mode
Enter SECTION [953] (NOTE: this 953 is common section applicable for all the expansion modules)

Then, choose one of the following expansion modules serial numbers


4.
5.
6.

Enter 8-digit [Serial number] of the Expansion module


Enter 3-digit [SECTION] you wish to program
Enter required [DATA]

Press [ENTER] to confirm or [CLEAR] to ignore

A: LCD keypad (DGP2-641)


Section [003], ON key [2,3 & 8], to display exit delay, entry delay and time on keypad

B: 48 zone (DGP-648) LED keypads

C: Addressable PIR (DGP2-50 / DGP2 60 / DGP2 70)


Section [001], On key 1, for less sensitive
Section [002], enter [003], meaning 000 is for very sensitive, 002 normal and 003 less sensitive. (default is 002)

D: Omnia Wireless Receiver Module (OMN-RCV3)


Section [001], On key [1], for low battery supervision
st

Press section [101], enter [6 digit S/N], means 8 digits is the transmitter S/N. (becomes 1 input of the receiver)
nd
Press section [102], enter [6 digit S/N], means 8 digits is the transmitter S/N. (becomes 2 input of the receiver)
Press section [103], enter [6 digit S/N], means 8 digits is the transmitter S/N. (becomes 3rd input of the receiver)
th
Press section [104], enter [6 digit S/N], means 8 digits is the transmitter S/N. (becomes 4 input of the receiver)
Press section [105], enter [6 digit S/N], means 8 digits is the transmitter S/N. (becomes 5th input of the receiver)
th
Press section [106], enter [6 digit S/N], means 8 digits is the transmitter S/N. (becomes 6 input of the receiver)
th
Press section [107], enter [6 digit S/N], means 8 digits is the transmitter S/N. (becomes 7 input of the receiver)
th
Press section [108], enter [6 digit S/N], means 8 digits is the transmitter S/N. (becomes 8 input of the receiver)
Press section [109], enter [6 digit S/N], means 8 digits is the transmitter S/N. (becomes 9th input of the receiver)
th
Press section [110], enter [6 digit S/N], means 8 digits is the transmitter S/N. (becomes 10 input of the receiver)
Press section [111], enter [6 digit S/N], means 8 digits is the transmitter S/N. (becomes 11th input of the receiver)
th
Press section [112], enter [6 digit S/N], means 8 digits is the transmitter S/N. (becomes 12 input of the receiver)
th
Press section [113], enter [6 digit S/N], means 8 digits is the transmitter S/N. (becomes 13 input of the receiver)
th
Press section [114], enter [6 digit S/N], means 8 digits is the transmitter S/N. (becomes 14 input of the receiver)
Press section [115], enter [6 digit S/N], means 8 digits is the transmitter S/N. (becomes 15th input of the receiver)
th
Press section [116], enter [6 digit S/N], means 8 digits is the transmitter S/N. (becomes 16 input of the receiver)
For MG Remote Control

Assign Remote to follow panels user number


Press section [301], enter [3 digit user no.], for remote control 1.
Press section [302], enter [3 digit user no.], for remote control 2.
up to [316] for remote control 16.

Button assignment (for button A, B, C, D)


Press section [401], enter [1,5,7,7], for remote control 1.
Press section [402], enter [1,5,7,7], for remote control 2.
up to [416] for remote 16
For Button C activates (ON for 2 seconds) PGM on OMNIA RCV3 Receiver [for example to trigger autogate]
Press section [401], enter [1,5,0,7], for remote control 1s Button C to trigger PGM 3 on RCV3 for 2 seconds

Note:
Meaning Button A (TOP) assigned for Regular Arming, Button B (BOTTOM) assigned for Disarm and Button C
(LEFT) & D (RIGHT) are assign for Panic (same as keypad panic 1& MUST program in section [506][ON key 1 &
4], or else, it will not function).

Program Remote to recognise the panel


Press section [201][Press Button A slowly and firmly on remote control no.1 TWO times](you will hear a
confirmation beep).
Press section [202][Press Button A slowly and firmly on remote control no.2 TWO times](you will hear a
confirmation beep).
.up to [216] for remote control 16

E: 4-PGM output module (APR3-PGM4)

F: 8 zone hardwire module (APR3-ZX8)

Section 003, enter [003], input 1 on board for 45 ms for vibration sensor
Section 005, enter [003], input 2 on board for 45 ms for vibration sensor
Section 007, enter [003], input 3 on board for 45 ms for vibration sensor
Section 009, enter [003], input 4 on board for 45 ms for vibration sensor
Section 011, enter [003], input 5 on board for 45 ms for vibration sensor
Section 013, enter [003], input 6 on board for 45 ms for vibration sensor
Section 015, enter [003], input 7 on board for 45 ms for vibration sensor
Section 017, enter [003], input 8 on board for 45 ms for vibration sensor

Note: 001 for 15 ms, 002 for 30ms, 003 for 45ms, 004 for 60 ms..default is 600ms
G: 4 zone hardwire module (APR3-ZX4)

Section 003, enter [003], input 1 on board for 45 ms for vibration sensor
Section 005, enter [003], input 2 on board for 45 ms for vibration sensor
Section 007, enter [003], input 3 on board for 45 ms for vibration sensor
Section 009, enter [003], input 4 on board for 45 ms for vibration sensor

Note: 001 for 15 ms, 002 for 30ms, 003 for 45ms, 004 for 60 ms..default is 600ms
H: 1 zone hardwire module (DGP2-ZX1)

Section 003, enter [003], input 1 on board for 45 ms for vibration sensor
Note: 001 for 15 ms, 002 for 30ms, 003 for 45ms, 004 for 60 ms..default is 600ms
I: InTouch voice arm / disarm module (APR3-ADM2)

Section 001, enter [015], 15 ring count (default: 8 rings)

Misc. 1 - Utility

Walk test where Siren will squawk to indicate opened zones


To active
To De-active

: Press & hold [0], then enter [000000], press [MEM] [ENTER] [CLEAR]
: Press & hold [0], then enter [000000], press [MEM] [ENTER] [CLEAR]

Note: MUST de-active or else system cannot be armed even though keypad shows Ready.

Clear TBL 8 Timer loss


Press [TRBL] key, then [8] key, enter [HH:MM] then [YYYYMMDD],[CLEAR]
E.g.: Press [TRBL] key, then [8] key, enter [15:30] then [2000830],[CLEAR]

Answer Winload software / pickup the line


Press & hold [0], then enter [000000], press [ARM]


Cancel dialer
Press & hold [0], then enter [000000], press [DISARM]

Start module scan


Press & hold [0], then enter [000000], press [TRBL]
The keypad will display the serial number of each module on the bus

Read voltage at keypad bus


Press & hold [0], then enter [000000], press [ACC]
A reading of 12.3V or lower that indicates voltage is too low

Misc. 2 Default setting

Display serial number of control panel and all modules


Keypad will display the 8-digit serial number of control panel and all modules
Press & hold [0], then enter [000000], you are in the programming mode
Then, key in [900], use [^] and [V] to scroll.

Module reset
Reset a modules programming contents to default by entering its serial number
Press & hold [0], then enter [000000], you are in the programming mode
Then, key in [951], then enter [8-digits serial number], the module will be defaulted.

Remove modules
Control panel will scan all modules connected to the bus and remove those modules already disconnected.
Press & hold [0], then enter [000000], you are in the programming mode
Then, key in [955], wait for few minutes and it will exit programming mode by itself.

Default master code to 1234 (user code 02 onward remains)


To reset missing master code back to default:1234
Put the RESET jumper on the control panel to ON (shorting)
Press & hold [0], then enter [000000], you are in the programming mode
Then, key in [950]. Remember to remove the RESET jumper to OFF (not shorting)

10

SECTION C: User Functions


Normal function:
Regular Arming
Stay Arming
Instant Arming
Force Arming
Bypass
Disarm

Key in [4 digit user code], then press [ARM]


Key in [4 digit user code], then press [STAY], meaning bypass PIR zone
Key in [4 digit user code], then press [INSTANT = Key5]
Key in [4 digit user code], then press [FORCE]
Key in [4 digit user code], then press [BYP], ENTER [2 digit zone] &[ENTER]
Key in [4 digit user code]

Note: Regular arming will be same as Stay arming if the Delay zone is NOT open during exit delay time.
One-Touch Button:
Arm
Stay
Force
Instant

Press [ARM]
Press [STAY]
Press [FORCE]
Press [INSTANT=Key 5]

Panic function:
Press [1] & [3] at the same time, for Emergency panic alarm.
Press [4] & [6] at the same time, for Auxiliary panic alarm.
Press [7] & [9] at the same time, for Fire panic alarm.

Activating a chime zone:


Enter [4 digit user code], then press [9], [1][2digit zone number], [CLEAR] to exit

Change Master / create new user code


Enter [master code], Press & hold [0], press [ACC] [ 2 digit user, 01 for master, 02 for user 2] [4 digits new code][
ON key for user options], press [], then on key [1]
E.g.:
[1234] [Press & hold [0] [ACC][01] [5678][ON key 6,7][ ENTER], where 01 is master user and 5678 is the new
master code.
[1234] [Press & hold [0] [ACC][02] [7878][ON key 6,7][ ENTER], where 02 is user 2 and 7878 is the user 2 code.
[1234] [Press & hold [0] [ACC][09] [5354][ON key 3,6,7][ ENTER], where 09 is duress code.

11

Partitioning (2-partition)
STEP 1: Zone programming
Press & hold [0], then enter [000000], you are in the programming mode
Press section [101], [6,1, ENTER, CLEAR], means ZONE 1 Instant, Partition 1.
Press section [102], [6,1, ENTER, CLEAR], means ZONE 2 Instant, Partition 1.
Press section [103], [6,2, ENTER, CLEAR], means ZONE 3 Instant, Partition 2.
Press section [104], [6,2, ENTER, CLEAR], means ZONE 4 Instant, Partition 2.
Press section [105], [1,1, ENTER, CLEAR], means ZONE 5 Delay, Partition 1.
STEP 2: Enable features
Section 500, ON key [2 & 6], 1 and 5 remain ON
Section 510, ON key [1,2,3,4,5 & 6]
STEP 3: User authority (NOT in Installation programming, BUT in master programming) [LCD keypad User
manual page 30]
Enter [master code - 1234], press [[PRG], [ACC], then key in [02], key in [new user 2 code- 2222], press [^], user
options [ON 4 & 8], press [^], assign area [ON 2], then press [ENTER][CLEAR]
STEP 4: User operation (Master code:1234)
To arm: [1234][ARM][0][1 and 2], arm partition 1 and 2
To disarm partition 2: [2222][DISARM]
To disarm both partitions: [1234][DISARM][0]

V4.00 26092005

12

FAQ How to wire a smoke detector on Digiplex 848

Diagram for additional RELAY board (12V DC coil and AC/DC contact) to reset smoke detector, you also need to
program PGM output, as follows:

Press & hold [0], then enter [000000], you are in the programming mode
Step 1:
Section [400], enter [41] then [ON key 5][ENTER][CLEAR]
To reset smoke detector once trigger: Press and hold [ENTER] & [CLEAR] for 2 seconds.
Step 2:
Program zone type to Fire zone, value is [A]
Example:
Press section [108], [A,1, ENTER], means ZONE 8 is FIRE zone, Partition 1.
Step 3: Wiring
Digiplex 848
PGM1 PGM2

Aux
+

To
zone
Smoke

detector
Relay

NO
COM
NC
+

13

Programming Planning Sheet

Module type

Main board DGP-848

8-digits serial
number

Assigned zone
number

Located at

1 to 8

Keypad 1

14