Ecg Machine Contec Type 1200g
Ecg Machine Contec Type 1200g
Basic Info.
Model NO.:ECG 1200G
Classification:Biological Diagnostics
Type:Digital EEG/ECG/EKG/EMG/VCG
Package:Carton
Specification:CE
Trademark:CONTEC
Origin:China
Screen Size:8 Inches
Leads:12 Leads
Product Description
Features:
1. 8"TFT Color LCD shows the working status and ECG waveform. Check the waveform before
printing to save record paper.
2. 12 Leads ECG simultaneous acquisition, digital signal processor, to get higher quality ECG
waveforms through the AC filter, baseline filter and EMG filter of the ECG signals.
3. Simultaneous display of 3/6/12 leads ECG waveform, and the state of printing mode, sensitivity,
speed, filter etc, to be easy for interpretation.
4. Include multiform printing modes and formats, such as 12\6+1(rhythm)\6\rhythm 12\rhythm
10\rhythm 8\rhythm 6\Manual\Freeze etc; The length of wave printing can be adjusted and the
function of periodic printing is included to satisfy different applications.
5. The instrument has the function of regular auto-analysis and auto-interpretation of ECG waveform
parameter, provide measurement parameters such as HR, P-R interval, P Duration, QRS
Duration, T Duration, Q-T interval, Q-Tc, P Axis, QRS Axis, T Axis, R(V5), S(V1), R(V5)+S(V1),
etc and auto-interpretation conclusion to help reducing doctor's abundance and improve working
efficiency.
6. The power supply includes both AC/DC. This device includes built-in lithium polymer
rechargeable battery. It can standby for 4 hours, print 150 pieces of ECG waveform and print 90
minutes continually under the best DC state to satisfy the need of visiting patients and physical
examination.
7. It has build-in storage with large capacity, and can memory more than 1000 cases, which is easy
for doctor review and statistic.
8. Support Chinese, English, Spanish and Turkish Operating interface, can print out Multi-language
report formats.
9. Include multiform printing speeds such as 5mm/s, 6.25mm/s, 10mm/s, 12.5mm/s, 25mm/s,
50mm/s. Provide graphic result format for visual diagnostic.
Environment conditions
Operation
A) Environment temperature
B) Relative humidity
C) Power supply
D) Atmospheric pressure
Transportation and Storage
A) Environment temperature: -10~55 centigrade degree
B) Relative humidity: 95%
C) Atmospheric pressure: 50kPa~106kPa
Screen size
8 inches
Leads
12 leads
Input way
Lead
Standard 12 leads(model:BIP0057)
<10A
Input impedance
50M
Frequency response
0.05Hz~150Hz(-3dB)
Time constant
Time constant>3.2s
CMRR
35Hz(-3dB)
Recording way
Specification of recording
paper
Paper speed
Sensitivity selections
Auto record
Rhythm record
Manual record
Measurement parameters
Noise level
15Vp-p
Fuse specification
Size
340mm(L)*320mm(W)*85mm(H)
Net Weight
3.2Kg