IPN
Current Transducer LA 55-P
50 A
For the electronic measurement of currents: DC, AC, pulsed...,
with a galvanic isolation between the primary circuit (high power)
and the secondary circuit (electronic circuit).
16019
Electrical data
IPN
IPM
RM
Primary nominal current rms
Primary current, measuring range
Measuring resistance @
with 12 V
with 15 V
ISN
KN
VC
IC
Vd
50
0 .. 70
TA = 70C
TA = 85C
RM min RM max RM min RM max
@ 50 A max
@ 70 A max
@ 50 A max
@ 70 A max
10
10
50
50
100
50
160
90
Secondary nominal current rms
Conversion ratio
Supply voltage ( 5 %)
Current consumption
Rms voltage for AC isolation test, 50 Hz, 1 min
A
A
Accuracy @ IPN , TA = 25C
@ 15 V ( 5 %)
@ 12 .. 15 V ( 5 %)
Linearity error
60 95
60 1) 601)
135 155
135 2) 135 2)
50
mA
1 : 1000
12 .. 15
V
10 (@ 15 V) + IS m A
2.5
kV
0.65
0.90
< 0.15
Typ
IO
IOM
IOT
tra
tr
di/dt
BW
%
%
%
Max
0.2
mA
0.3
0.5
0.6
mA
mA
mA
Offset current @ IP = 0, TA = 25C
Magnetic offset current 3) @ IP = 0 and specified RM
after an overload of 3 x I PN
Temperature variation of IO
0C .. + 70C
- 25C .. + 85C
0.1
0.1
Reaction time @ 10 % of IPN
Response time to 90 % of IPN step
di/dt accurately followed
Frequency bandwidth (- 1 dB)
< 500
<1
> 200
DC .. 200
Closed loop (compensated) current
transducer using the Hall effect
Accuracy - Dynamic performance data
X
Features
ns
s
A/s
kHz
Printed circuit board mounting
Isolated plastic case recognized
according to UL 94-V0.
Advantages
Excellent accuracy
Very good linearity
Low temperature drift
Optimized response time
Wide frequency bandwidth
No insertion losses
High immunity to external
interference
Current overload capability.
Applications
AC variable speed drives and servo
motor drives
Static converters for DC motor drives
Battery supplied applications
Uninterruptible Power Supplies
(UPS)
Switched Mode Power Supplies
(SMPS)
Power supplies for welding
General data
applications.
TA
TS
RS
Ambient operating temperature
Ambient storage temperature
Secondary coil resistance @
Mass
Standards
Notes:
1)
2)
3)
TA = 70C
TA = 85C
- 25 .. + 85
- 40 .. + 90
80
85
18
EN 50178: 1997
C
C
Application Domain
Industrial.
Measuring range limited to 60 A max
Measuring range limited to 55 A max
Result of the coercive field of the magnetic circuit.
page 1/2
080114/13
LEM reserves the right to carry out modifications on its transducers, in order to improve them, without prior notice.
w w w .lem.com
Dimensions LA 55-P
(in mm. 1 mm = 0.0394 inch)
Front view
Bottom view
Left view
Connection
Mechanical characteristics
General tolerance
Primary through-hole
Fastening & connection of secondary
Recommended PCB hole
Safety
0.2 mm
12.7 x 7 mm
3 pins
0.63 x 0.56mm
0.9 mm
This transducer must be used in electric/electronic
equipment with respect to applicable standards and
safety requirements in accordance with the
manufacturer's operating instructions.
Remarks
IS is positive when IP flows in the direction of the arrow.
Temperature of the primary conductor should not exceed
90C.
Dynamic performances (di/dt and response time) are best
with a single bar completely filling the primary hole.
In order to achieve the best magnetic coupling, the primary
windings have to be wound over the top edge of the device.
This is a standard model. For different versions (supply
voltages, turns ratios, unidirectional measurements...),
please contact us.
Caution, risk of electrical shock
When operating the transducer, certain parts of the module
can carry hazardous voltage (eg. primary busbar, power
supply).
Ignoring this warning can lead to injury and/or cause
serious damage.
This transducer is a built-in device, whose conducting
parts must be inaccessible after installation.
A protective housing or additional shield could be used.
Main supply must be able to be disconnected.
page 2/2