4-1) Function for failure diagnosis
4-1-1. Test mode (manual operation / manual defrost function)
If Power Freeze & Fridge temperature control Key on the front of panel are pressed
simultaneously for 8 seconds , it will be changed to the test mode and all displays on the front
of panel will be off.
If any key on the front of panel is pressed within 15 seconds after the test mode, it will be
operated as below sequence :
manual operation(fresh food compartment) manual defrost of fresh food compartment(rd)
manual defrost of fresh food and freezer compartments (Fd) Cancel(Display all off).
If any key on the front of panel is not pressed within 15 seconds after the test mode, the test
mode will be canceled and it will be returned to previous mode.
1) Manual operation function
-2(-19)is Recommended
38(3)is Recommended
If Power Freeze Key + Fridge Key are pressed simultaneously for 8 seconds,
(displays are all off)
It will be changed to the test mode (manual operation) by pressing any key
1-1) If any key is pressed once in test mode, blinks "FF" on the display and it indicates the
refrigerator has entered the manual operation. At this moment, buzzer beeps as an
alarm.
1-2) If manual operation is selected, comp will run at once without 5 minutes delay in any
mode. If the refrigerator is on the defrost cycle at the moment, defrost will be finished
and manual operation will begin.
(Be careful if manual operation get started at the moment of comp off, over load could
be occurred)
1-3) If manual operation works, comp & f-fan operate continuously for 24 hours and fresh
food compartment will be controlled by the setting temperature.
1-4) When the manual operation runs, setting temperature will be selected automatically as
below: freezer compartment -14 (-25 ), fresh food compartment 33.8 (1 ).
1-5) During manual operation, Power Freeze & Power Cool function will not be worked.
If a function is selected, the power function icon of the selected function will be off
automatically after 10 seconds.
1-6) Manual operation can be canceled during manual operation by turning on the appliance
after power off(reset) or choosing the step 4) test cancel mode.
1-7) Alarm(0.25 sec ON/ 0.75 sec OFF) will beep continuously until manual operation is
completed and there is no function to make the sound stop.
40
TROUBLESHOOTING
2) Manual defrost(fresh food compartment) function
2-1) If any key is pressed one more time during manual operation(fresh food compartment),
"rd" shows in the display and then manual operation will be canceled at once and fresh
food compartment will be defrosted.
2-2) At this moment, alarm beeps for 3 seconds(0.1 sec ON/ 1 sec OFF) during manual
defrost(fresh food compartment) function.
3) Simultaneous manual defrost(fresh food and freezer compartments) function
3-1) If any key is pressed one more time during manual defrost(defrost of fresh food
compartment, "rd"), "Fd" shows on the display and then fresh food and freezer
compartments defrost will operate.
Manual defrost of Fresh food and freezer compartments are followed by manual defrost
freezer compartment.
3-2) At this moment, alarm beeps for 3 seconds (0.5 sec ON/ 0.5 sec OFF) during manual
defrost function of fresh food and freezer compartment.
4) Test cancel mode
4-1) During defrosting of fresh food and freezer compartments simultaneously, if the display
panel change to the test mode and test button is pressed one more time, defrosting of
fresh food and freezer compartments will be canceled at the same time and will return
to the normal operation.
Or, all test functions will be canceled by turning main power ON again after it OFF.
4-1-2. Display function of Communication error
1) Display function when Panel MAIN MICOM communication has error
1-1) If there is no answer for 10 seconds after the panel micom received the requirement of
communication, "Pc - Er" display on the panel PCB will be ON/OFF alternately until the
communication error is canceled. (0.5 sec ALL ON, 0.5 sec ALL OFF alternately)
(0.5 sec ALL ON, 0.5 sec ALL OFF alternately)
41
TROUBLESHOOTING
2-2) Also pantry room display will be ON/OFF alternately until the communication error is
canceled.
(0.5 sec ALL ON, 1.5 sec ALL OFF alternately)
4-1-3. Self-diagnostic function
1) Self-diagnostic function in the Initial power ON
1-1) Micom operates self-diagnostic function to check the temperature sensor condition
within 1 second when the refrigerator turned On initially.
1-2) If bad sensor is detected by the self-diagnostic function, the applicable display LED will
blink for 0.5 sec.
At this moment, there is no beep sound.(Refer to self-diagnostic CHECK LIST)
1-3) Self-diagnostic button is recognized only when the error is displayed by the bad sensor.
Display does not operate normally but temperature control will be controlled by the
emergency operation.
1-4) When the error is detected by self-diagnosis, the error can be canceled automatically if
all troubled sensors are corrected or Self-diagnostic function key (Power Freeze +
Power Cool ) are pressed simultaneously for 8 seconds.
(Return to normal display mode)
-2(-19)is Recommended
38(3)is Recommended
-2(-19)is Recommended
38(3)is Recommended
42
TROUBLESHOOTING
2-1) If Power Freeze + Power Cool Key are pressed simultaneously for 6 seconds during
normal operation, the temperature setting display will operate for 2 seconds (ON/OFF
0.5sec each).
If Power Freeze + Power Cool Key are pressed simultaneously for 8 seconds (including
above 2 seconds), self-diagnostic function will be selected.
2-2) At this moment, self-diagnostic function will be returned with buzzer sound 'ding-dong'.
If there is an error, display of error will be operated for 30 seconds and then return to
normal condition whether problem is corrected or not.
(Refer to self-diagnosis CHECK LIST)
2-3) Input by button is not accepted during self-diagnostic function.
Self-diagnosis CHECK LIST
Trouble item
Display LED
Trouble contents
NO
Ice Maker Sensor Error
R-1ICE MAKER SENSOR part error
1
R-Sensor Error
R-1FF SENSOR part error
2
R-DEF-Sensor Error
R-1FF defrost SENSOR part error
3
R-FAN Error
R-1FF inner fan motor part error
4
Ice Maker Error
R-1ICE MAKER operation error
5
R-DEF.Error
R-1FZ defrost part error
6
Ambient-Sensor Error
F-1External SENSOR part error
7
F-Sensor Error
F-1FZ SENSOR part error
8
F-DEF-Sensor Error
F-1FZ defrost SENSOR part error
9
F-FAN Error
F-1FZ inner fan motor part error
10
C-FAN Error
F-1Machine room fan motor part error
11
F-DEF. Error
F-1FZ defrost part error
12
Pantry-Damper-Heater Error
R-10Damper Heater open/wire error
13
Pantry-Sensor Error
R-10Pantry Room SENSOR part error
14
Panel Main MICOM communication error
15 Panel Main MICOM communication Error F-10L M communication Error
F-10LOAD Main MICOM communication error
16
F-10
F-1
R-10
R-1
43
TROUBLESHOOTING
Self-diagnostics check list
Item
Trouble contents
R-1-
R-1-
R-Sensor Error
R-1-
R-DEF-Sensor Error
R-1-
R-FAN Error
R-1-
LED
R-1-
R-DEF. Error
F-1-
Ambient-Sensor Error
F-1-
F-Sensor Error
F-1-
DEF-Sensor Error
F-1-
F-FAN Error
F-1-
C-FAN Error
F-1-
F-DEF. Error
R-10-
Pantry-Damper-Heater Error
R-10-
Pantry-Sensor Error
F-10-
F-10-
Diagnostic method
When checking the voltage of MAIN PCB CN90
#3 CN90#4 : shall be between 4.5V~1.0V.
When checking the voltage of MAIN PCB
CN30#6 CN75#1:shall be between 4.5V~1.0V
When checking the voltage of MAIN PCB
CN30#7 CN75#:shall be between 4.5V~1.0V
Voltage of MAIN PCB CN75 Orange
shall be between 7V~12V
Gray
Gray
Gray
Display error when open error is detected by damper After separating MAIN PCB CN91from PCB, check the resistant
heater : separation of Damper Heater housing part, value between Black brown wire shall be 145 ohm 7%.
Check 0 Ohm : heater short, Ohm : wire / bimetal Open.
contact error, disconnection, short circuit
Display error : separation of sensor housing, contact error,
disconnection, short circuit.
Display error by detecting temperature of sensor: more
than 149 (+65C) or less than -58 (-50C)
44
TROUBLESHOOTING
4-1-4. Display function of Load condition
-2(-19)is Recommended
38(3)is Recommended
If Power Freeze Key + Power Cool Key are pressed simultaneously for 6
seconds, ALL ON/OFF will blink with 0.5interval for 2 seconds.
If take the finger off from above keys and press Fridge Key, load condition mode
will be started.
1) If Power Freeze Key + Power Cool Key are pressed simultaneously for 6 seconds during normal operation, the
temperature setting display of fresh food and freezer compartments will blink ALL ON/OFF with 0.5 for 2
seconds.
2) At this moment, If Fridge Key after Power Freeze Key + Power Cool Key is pressed, load condition display
mode will be returned with alarm.
3) Load condition display mode shows the load that micom signal is outputting.
However, It means that micom signal is outputting, it does not mean whether load is operating or not. That is to
say that though load operation is displayed, load could not be operated by actual load error or PCB relay error
etc.
4) Load condition display function will maintain for 30 seconds and then normal condition will be returned
automatically.
5) Load condition display is as below.
F-1
R-1
F-10
R-10
Display contents
Operation contents
R-FAN High
R-FAN Low
R-DEF Heater
Start Mode
Overload condition
Low temperature condition
Normal Condition
Exhibition Mode
COMP.
F-FAN High
F-FAN Low
F-DEF Heater
C-FAN High
C-FAN Low
French Heater
Pantry Room Damper Open
45
TROUBLESHOOTING
4-1-5. Exhibition mode setting function
-2(-19)is Recommended
38(3)is Recommended
If Power Freeze Key + Freezer Key are pressed for 3 seconds, show room mode will
be started.
1) If Power Freeze Key + Freezer Key are pressed simultaneously for 3 seconds during normal
operation, show room mode will be started with buzzer sound(ding-dong).
2) If above Power Freeze & Freezer Key are pressed one more time, show room mode will be
canceled.
3) If show room mode is selected, blinks "OF-OF" on the temperature setting display of the panel
and it indicates the refrigerator has entered the show room mode.
4) During show room mode, if fresh food and freezer compartments sensors are higher than 65
show room mode will be canceled automatically and freezing operation will be returned.
(There is no buzzer sound when the show room mode is canceled by the temperature)
5) Operation contents of show room mode
- Display, Fan motor and etc operate normally, not to operate compressor only.
- Defrost is not operated. (including french heater)
- Display function of the initial real temperature is finished.
- Under the condition of show room mode, show room mode will be operated when Power On
after Power OFF.
4-1-6. Option setting function
If Freezer Key + Fridge Key are pressed simultaneously for 12 seconds during normal
operation, fresh food and freezer compartments temperature display will be changed to option
setting mode.
KEY operation method for changing to option mode
-2(-19)is Recommended
38(3)is Recommended
If Freeze Key + Fridge Key are pressed simultaneously for 12 seconds, option
setting mode will be started.
46
TROUBLESHOOTING
Reference
Value Down
-2(-19)is Recommended
Code
Up
38(3)is Recommended
Code
Reference
Value
Reference
Value Up
If the display changes to option setting mode, all displays will be off except freezer and
fridge compartments temperature display as below.
(Fresh food and freezer compartments case will be explained only because all options
are operated with the same method according to the option table.)
Code
Reference Value
1) For example, if you want to change freezer compartment standard temperature to 28.4 (2C) by operating option, do as below.
This function is for changing the standard temperature.
In -2 (-19C) of current temperature of freezer compartment, if you make the temperature
lower to 28.4 (-2C) by the option, the standard temperature would be controlled -6 (-21C)
Therefore, if you change the setting of temperature option to -2 (-19C) on the panel, the
appliance will be operated with -6 (-21C).
It means that standard temperature is controlled 28.4 (-2C) less than setting temperature in
the display.
NOTE
TROUBLESHOOTING
2) After changing to the option mode, fresh food compartment "0" , freezer compartment
"0" will be displayed. ( Basically fresh food compartment "0", freezer "0" would be set at
shipping process, but setting value could be changed for the purpose of improving
product at mass producing process.)
- If fresh food compartment "0" shows only, temperature reference value of freezer
compartment will be set and current freezer compartment temperature code will be
displayed on the freezer temperature display.
3) If freezer compartment "4" is set as below freezer compartment code after fresh food
compartment "0 is set, standard temperature of freezer compartment will be lower than
28.4 (-2.0C).
(Refer to the picture "changing the freezer compartment temperature")
Code
Reference Value
: If you wait for 20 seconds after completing the setting, MICOM will save the setting
value to the EEPROM and normal display will be returned and the option setting mode
will be canceled.
4) Option changing method as above is the same as all RF266/265** model.
5) By the same method as above, it is possible to control the fresh food compartment
temperature, water supply, ice-maker harvest temperature/time, defrost return time,
hysteresis by temperature, notch gap by temperature etc.
6) Option function is set in the EEPROM at shipping process in the factory.
You would better not to change the option of your own.
Completing the setting is that option function return to normal display after 20 seconds.
Do not turn off the appliance before returning to the normal display mode.
NOTE
48
TROUBLESHOOTING
4-1-7. Option TABLE
1) Temperature changing table of freezer compartment
Set item
MODEL
RF265/266/RF26NB
Reference
Value
Setting value
Temp.
FZ
compartment compensation
Code
32 (0.0C)
0
1
31.1 (-0.5C)
30.2 (-1.0C)
29.3 (-1.5C)
28.4 (-2.0C)
27.5 (-2.5C)
26.6 (-3.0C)
25.7 (-3.5C)
32.9 (+0.5C)
33.8 (+1.0C)
10
34.7 (+1.5C)
11
35.6 (+2.0C)
12
36.5 (+2.5C)
13
37.4 (+3.0C)
14
38.3 (+3.5C)
15
39.2 (+4.0C)
Code
Reference Value
ex) If you want to change the freezer standard temperature to 28.4 (-2C)
MODEL
RF265/266/RF26NB
Reference
Value
Setting value
Temp.
FZ
compartment compensation
Code
32 (0.0C)
31.1 (-0.5C)
30.2 (-1.0C)
29.3 (-1.5C)
28.4 (-2.0C)
27.5 (-2.5C)
26.6 (-3.0C)
25.7 (-3.5C)
32.9 (+0.5C)
33.8 (+1.0C)
10
34.7 (+1.5C)
11
35.6 (+2.0C)
12
36.5 (+2.5C)
13
37.4 (+3.0C)
14
38.3 (+3.5C)
15
39.2 (+4.0C)
Code
49
Reference Value
TROUBLESHOOTING
Below options are applied to the applicable model with ice maker.
Do not set below options to the model without Ice Maker.
3) To change the ice maker harvest waiting time
This option controls the harvest waiting time for ice dispensing from Ice maker
Set item
Reference
Value
Setting value
FZ
compartment
Code
Temp.
compensation
(mins)
58
57
56
55
54
53
52
51
50
49
10
48
11
47
12
46
13
45
14
59
15
60
Code
Reference Value
1.4 (-17C)
3.2 (-16C)
5.0 (-15C)
6.8 (-14C)
8.6 (-13C)
10.4 (-12C)
-0.4 (-18C)
2.2 (-19C)
Code
Reference Value
50
TROUBLESHOOTING
4-2) Diagnostic method according to the trouble symptom(Flow Chart)
DATA1.Temperature table
Resistance value and MICOM port voltage of sensor according to the temperature
SENSOR CHIP : based on PX41C
-50
-49
-48
-47
-46
-45
-44
-43
-42
-41
-40
-39
-38
-37
-36
-35
-34
-33
-32
-31
-30
-29
-28
-27
-26
-25
-24
-23
-22
-21
-20
-19
-18
-17
-16
-15
-14
-13
-12
-11
-10
-9
-8
-7
-6
-58
-56.2
-54.4
-52.6
-50.8
-49
-47.2
-45.4
-43.6
-41.8
-40
-38.2
-36.4
-34.6
-32.8
-31
-29.2
-27.4
-25.6
-23.8
-22
-20.2
-18.4
-16.6
-14.8
-13
-11.2
-9.4
-7.6
-5.8
-4
-2.2
-0.4
1.4
3.2
5
6.8
8.6
10.4
12.2
14
15.8
17.6
19.4
21.2
Voltage Resistance
4.694
4.677
4.659
4.641
4.622
4.602
4.581
4.560
4.537
4.514
4.490
4.465
4.439
4.412
4.385
4.356
4.326
4.296
4.264
4.232
4.199
4.165
4.129
4.093
4.056
4.018
3.980
3.940
3.899
3.858
3.816
3.773
3.729
3.685
3.640
3.594
3.548
3.501
3.453
3.405
3.356
3.307
3.258
3.208
3.158
153319
144794
136798
129294
122248
115631
109413
103569
98073
92903
88037
83456
79142
75077
71246
67634
64227
61012
57977
55112
52406
49848
47431
45146
42984
40938
39002
37169
35433
33788
32230
30752
29350
28021
26760
25562
24425
23345
22320
21345
20418
19537
18698
17901
17142
-5
-4
-3
-2
-1
0
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
23
24.8
26.6
28.4
30.2
32
33.8
35.6
37.4
39.2
41
42.8
44.6
46.4
48.2
50
51.8
53.6
55.4
57.2
59
60.8
62.6
64.4
66.2
68
69.8
71.6
73.4
75.2
77
78.8
80.6
82.4
84.2
86
87.8
89.6
91.4
93.2
95
96.8
98.6
100.4
102.2
Voltage Resistance
3.107
3.057
3.006
2.955
2.904
2.853
2.802
2.751
2.700
2.649
2.599
2.548
2.498
2.449
2.399
2.350
2.301
2.253
2.205
2.158
2.111
2.064
2.019
1.974
1.929
1.885
1.842
1.799
1.757
1.716
1.675
1.636
1.596
1.558
1.520
1.483
1.447
1.412
1.377
1.343
1.309
1.277
1.253
1.213
1.183
51
16419
15731
15076
14452
13857
13290
12749
12233
11741
11271
10823
10395
9986
9596
9223
8867
8526
8200
7888
7590
7305
7032
6771
6521
6281
6052
5832
5621
5419
5225
5039
4861
4690
4526
4369
4218
4072
3933
3799
3670
3547
3428
3344
3204
3098
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
104
105.8
107.6
109.4
111.2
113
114.8
116.6
118.4
120.2
122
123.8
125.6
127.4
129.2
131
132.8
134.6
136.4
138.2
140
141.8
143.6
145.4
147.2
149
150.8
152.6
154.4
156.2
158
159.8
161.6
163.4
165.2
167
168.8
170.6
172.4
174.2
176
177.8
179.6
181.4
183.2
Voltage Resistance
1.153
1.124
1.095
1.068
1.040
1.014
0.988
0.963
0.938
0.914
0.891
0.868
0.846
0.824
0.803
0.783
0.762
0.743
0.724
0.706
0.688
0.670
0.653
0.636
0.620
0.604
0.589
0.574
0.560
0.546
0.532
0.519
0.506
0.493
0.481
0.469
0.457
0.446
0.435
0.424
0.414
0.404
0.394
0.384
0.375
2997
2899
2805
2714
2627
2543
2462
2384
2309
2237
2167
2100
2036
1973
1913
1855
1799
1745
1693
1642
1594
1547
1502
1458
1416
1375
1335
1297
1260
1225
1190
1157
1125
1093
1063
1034
1006
978
952
926
902
877
854
832
810
TROUBLESHOOTING
4-2-1. If the trouble is detected by self-diagnosis
- The error of sensor will be displayed on the front of display.
when the error of sensor is detected at initial power ON, the appliance will not operated and display
of abnormal sensor part will blink.
- The appliance will not stop operating when the error of sensor is detected during operation of the
appliance.
But normal freezing might be not operated if the appliance is operated by the emergency operation
mode. You would better to check the appliance according to the self-diagnosis of the manual.
Start
DATA1.
Temperature table
** Measuring point of resistance value according to
Sensor **
ICE MAKER : CN90#3 #1 measuring resistance value
** 0 : Short trouble /
: Open trouble
NO
YES
Is the voltage between
MAIN PCB Connector CN90#"4"(White) and
CN1#"3"(Black) normal?
YES
Measuring voltage of IC02 MICOM #30,
CN90#4(White) and CN1#3(Black) from
PCB typical Ground part are similar.
YES
52
TROUBLESHOOTING
2) If R Sensor has trouble
ERROR Code
Start
DATA1.
Temperature table
Is MAIN PCB
Connector CN30 to CN75 inserted
correctly?
YES
Is R Sensor
unit normal?
NO
YES
Is the voltage between
MAIN PCB Connector CN30#6(White) to
CN1#3(Black) normal?
YES
Measuring voltage IC01 MICOM #54,
CN30#6(White) and CN1#3(Black)
from PCB typical Ground part are similar.
YES
53
TROUBLESHOOTING
3) If R DEF Sensor has trouble
ERROR Code
Start
DATA1.
Temperature table
Is MAIN PCB
Connector CN30 to CN75 inserted
correctly?
YES
Is R DEF Sensor
unit normal?
NO
YES
Is the input voltage between
MAIN PCB Connector CN30#7(Skyblue)
to CN1#3(Black) normal?
YES
Measuring voltage of IC01 MICOM #57,
CN30#7(Sky-blue) and CN1#3(Black) from
PCB typical Ground part are similar.
YES
54
TROUBLESHOOTING
4) If Ambient Sensor has trouble
ERROR Code
Start
DATA1.
Temperature table
** Measuring point of resistance value according to
Sensor **
Ambient : CN32#1 #4 measuring resistance value
** Placed in the right top table of upper hinge.
** 0 : Short trouble /
: Open trouble
Is MAIN PCB
Connector CN32 inserted
correctly?
YES
Is Ambient Sensor
unit normal?
NO
YES
Is the voltage between
MAIN PCB Connector CN32#1(White)
to CN1#3(Black) normal?
YES
Measuring voltage of IC01 MICOM #59,
CN32#1(White) and CN1#3(Black) from
PCB typical Ground part are similar.
YES
55
TROUBLESHOOTING
5) If F Sensor has trouble
ERROR Code
Start
DATA1.
Temperature table
Is F Sensor
unit normal?
NO
YES
Is the voltage between
MAIN PCB Connector CN30#3(Red) to
CN1#3(Black) normal?
YES
Measuring voltage of IC01 MICOM #52,
CN30#3(Red) and CN1#3(Black) from
PCB typical Ground part are similar.
YES
56
TROUBLESHOOTING
6) If F DEF Sensor has trouble
ERROR Code
Start
DATA1.
Temperature table
Is F DEF Sensor
unit normal?
NO
YES
Is the voltage between
MAIN PCB Connector CN30#4(Orange)
to CN1#3(Black) normal?
YES
Measuring voltage of IC01 MICOM #53,
CN30#4(Orange) and CN1#3(Black) from
PCB typical Ground part are similar.
YES
57
TROUBLESHOOTING
7) If Pantry Sensor has trouble
ERROR Code
Start
DATA1.
Temperature table
Is MAIN PCB
Connector CN30 insert
correctly?
YES
Is Pantry Sensor
normal?
NO
YES
Is the voltage between
MAIN PCB Connector CN30#8(Whiteblack)
to CN1#3(Black) normal?
YES
Measuring voltage of IC01 MICOM #58,
CN30#8(White-black) and CN1#3(Black)
from PCB typical Ground part are similar.
YES
58
TROUBLESHOOTING
8) If Pantry Room Damper Heater has trouble
ERROR Code
Start
Measure the resistance
between - after
CN90 connector open 145ohm
7%
Is Damper Heater
normal?(about145ohm)
NO
YES
Is MAIN PCB connector
(CN91) inserted correctly?
Replace Damper
NO
YES
Initial
Damper Damper
MICOM power On heater off heater On
#37
4.0V ~
condition 4.0V ~
0V
4.5V
4.5V
Normal(recheck)
59
NO
TROUBLESHOOTING
4-2-2. If FAN does not operate
- The refrigerator of this model has BLDC FAN motor. BLDC motor is driven by DC 7~12V.
- On the normal condition of COMP ON, it operates together with F-FAN motor.
If door is opened and closed once at a high ambient temperature, it will be operated after 1 minute
delay.
Therefore, you are advised not to taken it for an error.
-. If there is a trouble, you should select the self-diagnostic function to check the trouble before power off.
Start
Is COMP ON ?
Execute manual
operation
Is the voltage between MAIN
PCB CN1#3 (Black) and CN75#4(Sky
-blue) around DC7~12V?
0V(Low)
5V(High)
Reference
CN75-5(F),6(R),7(C)will generate the pulse signal when motor rotates.
These signals will be inputted into MICOM.
Unless signals are not inputted during motor operating, will be ON 10
seconds after fan Off. But if signals are not still entered, the above operation
will restart four times more.
If signals are not entered continuously, the motor will be restarted after 10
seconds.
This function is effective when the normal operation of motor would be
restrained by foreign matters such as ice.
F FAN ERROR
Expected causes
Check that if FAN-MOTOR has failure
itself.
Check that if wiring connection has bad
contact.
Check the input of the fan motor rotation
pulse when motor fan operates.
1) R-FAN
C FAN ERROR
60
2) F-FAN
3) C-FAN
TROUBLESHOOTING
4-2-3. If ICE MAKER does not operate
1. Water is automatically supplied to the Ice maker by temperature & time and ice maker dispenses
cubed or crushed ice.
2. Power is applied to one of its wires. So, refer to its exploded diagram when disassembling.
3. The operation of the Ice maker shall be checked after pressing the Ice maker test switch.
(Freezer compartment Ice Maker) It is not possible to check when the power is disengaged.
Function ERROR Code
Start
Does the self-diagnostic
function for detecting position of Ice maker at the
initial Power ON?
1) Check the wiring connection
2) Replace the ICE MAKER KIT
Micom(IC02) Condition
#29
(Test Switch)
Ready
Operation
5V
0V
Micom(IC02) Condition
Reverse- ReturnRotation Rotation Rotation
Ready
#27
5V
0V
5V
0V
Ready
5V
61
TROUBLESHOOTING
4-2-4. If defrost does not operate (F,R DEF Heater)
- If defrost has trouble, select the self-diagnostic function to detect the error of defrost heater before
Power Off. (Check the function with refer to the self-diagnostic function)
R DEF ERROR
F DEF ERROR
Start
86
68
50
32
14
-4
-22
(30
(20
(10
(0
(-10
(-20
(-30
)
)
)
)
)
)
)
4.22
6.05
8.87
13.29
20.42
32.23
52.41
Refer to self-diagnostic
function in the manual
Is defrost sensor by
self-diagnostic normal?
Replace the
applicable sensor
Is the temperature of
defrost sensor lower
than 53.6 (12C)?
Is power applied to
each defrost heaters?
1) F DEF Heater
2) R DEF Heater
Normal
Is connection terminal of
MAIN PCB part normal?
Repair connection terminal
Check bimetal, heater itself,
disconnection etc.
62
TROUBLESHOOTING
4-2-5. If Power is not supplied
Caution
At the power of main PCB, the
AC115(220)V power and a highvoltage over DC 170(325)V are
occurred. Please take care of
yourself on repair and measurement.
Start
Is DC5.8V
applied between TOP
switch 246Y C to S?
1) Replace U4 (D10LC20U)
2) Replace PCB ASS'Y
Is 5V applied both
terminals of C19?
Checking method of SMPS 2nd output
voltage CN2 input ; CN2#5(Yellow)
#3(Black) same as C16 terminals.
DC 12V
0.6V
1) Solder again
2) Replace PCB MAIN
Normal(Recheck)
63
TROUBLESHOOTING
4-2-6. If compressor does not operate
Start
Is freezer sensor
normal?
Is IC02 MICOM #8
High?(5V)
1) Replace MICOM
2) Replace PCB
Is COMP ASS'Y
normal?
Replace COMP ASS'Y
Normal (recheck)
64
TROUBLESHOOTING
4-2-7. When alarm sound continuous without stop(related with buzzer sound)
Is door closed
completely?
Door is ajar
Is water penetrated
into the door switch?
Replace Door S/W
5V(High)
0V(Low)
Is the input
voltage of main #50 and #3
changed at door-open,
door-close?
0V(Low)
5V(High)
Start
Is manual operation
/defrost selected?
Enforce the cancelation the
manual operation/ defrost function
or power On after power Off
65
TROUBLESHOOTING
Start
Does it sound
'dingdong' if press a button
on the front panel?
MAIN PCB normal,
BUZZER normal
Does it make a
sound of 'dooropen' alarm when
you are opening the door of freezer or
fridge more than 2 minutes?
66
TROUBLESHOOTING
4-2-8. If Panel PCB does not work normally
When lighting of Panel PCB is disabled or only some LED Lamp are disabled
Be careful to repair because display of this model is installed in the MICOM of internal PCB.
It is recommend to replace PCB MAIN after checking except specified solder touch.
Start
Is the connector of
upper hinge cover
inserted correctly?
Reinsert connector,
Repair bad contact
Is MAIN PCB
connector (CN50)
inserted correctly?
Reinsert connector,
Repair bad contact
Is lighting operate
normally when replace
Panel-PCB?
Check the wire of Top Table Panel - disconnection, short between wires
Check the wires between fresh food compartment upper cabinet - MAIN PCB - disconnection, short between wires
Check the wires of Top Table Panel - disconnection, short between wires.
Check the wires of fresh food compartment upper cabinet - disconnection, short between wires.
Check the short/open of the panel communication and power supply circuit in MAIN PCB.
67
TROUBLESHOOTING
4-2-9. If Pantry Panel PCB is not working normally
You should check the display after door opening because the display of this model operates only when
the fresh food compartment door is opened.
Start
2) normal(about5.0V 0.5V)
Is a key pressed
continuously?
68
TROUBLESHOOTING
4-2-10. When refrigerator ROOM Lamp does not light up
1. When you replace the lamp of freezer, please power OFF to avoid an electric shock.
2. Please keep in mind you could get burnt by the excessive heating of an incandescent light bulb.
3. Bimetal is installed in the refrigerator LAMP. Check that if LAMP may be OFF by bimetal.
The case of fresh food compartment(room) lamp will be explained only.
Because it is possible to repair the other room lamps with the same method.
Start
Is Lamp OFF by
bimetal operating?
Wait for returning time
of bimetal
F
MICOM
(#50)
R MICOM(#3)
5V(High)
0V(Low)
0V(Low)
5V(High)
Reference
* The interior lamp relay operates lighting/lightout
according to door open / close.
* If interior lamp does not light, check the noise of relay
operation.
* Noise of relay operation sounds every Door Open /
Close.
* F-LAMP Relay -- RY75
* R-LAMP Relay -- RY76
Is the connection
point of R-door switch
normal?
Repair door switch
Reference
If the door is opened, the contact of door switch will be opened and MICOM will get applied 5V to finally sense Open.
If 5V has been sensed over two minutes afterwards, Door-Open alarm will sound Ding-Dong for 10 seconds in a oneminute cycle. For
that reason, if the door switch has failure, the refrigerator can make a Ding-Dong sound per a oneminute cycle. Please note the step
for its service.
When measure lamp resistance to the Wire
Resistance can be changed by Lamp input voltage.
(Actual measurement is below, it can be changed by
performance)
Fresh food
compartment lamp
CN70#1(Red)
CN71#1 (Blue) ;
10(33)Ohm 3 Ohm
Lamp ; 60W + 60W
Freezer
compartment lamp
CN70#1(Red)
CN71#3 (Purple) ;
15(66)Ohm 5 Ohm
Lamp ; 60W
69
TROUBLESHOOTING
4-2-11. If ICE Water is not supplied
Start
Normal(Check Ice
water valve hose)
20%)
Check soldering
short/Replace PCB
Check soldering
short/Replace PCB
Check soldering
short/Replace PCB
70
TROUBLESHOOTING
4-2-12. If Water is not supplied
Start
Checking method of Valve resistance (Must
power off for checking)
Resistance can be changed by input voltage.
CN70#1 (Red)
CN73#5 (White-black)
- resistance value ; 388Ohm
7%)
** 0 : Short trouble /
: Open trouble
Normal(Check Ice
water valve hose)
Replace Valve
Check soldering
short/Replace PCB
Check soldering
short/Replace PCB
Check soldering
short/Replace PCB
20%)
71