Node, Loop, and Pipes
Pipe
Node
Loop
6/29/2012
Pipe Networks
The equations to solve Pipe network must
satisfy the following condition:
The net flow into any junction must be zero
Q = 0
The net head loss a round any closed loop must
be zero. The HGL at each junction must have one
and only one elevation
All head losses must satisfy the Moody and
minor-loss friction correlation
6/29/2012
Hydraulic Analysis
After completing all preliminary studies and
layout drawing of the network, one of the
methods of hydraulic analysis is used to
Size the pipes and
Assign the pressures and velocities
required.
6/29/2012
Hydraulic Analysis of Water Networks
The solution to the problem is based on the same
basic hydraulic principles that govern simple and
compound pipes that were discussed previously.
The following are the most common methods used
to analyze the Grid-system networks:
1.
2.
3.
4.
6/29/2012
Hardy Cross method.
Sections method.
Circle method.
Computer programs (Epanet,Loop, Alied...)
5
Hardy Cross Method
This method is applicable to closed-loop pipe
networks (a complex set of pipes in parallel).
It depends on the idea of head balance method
Was originally devised by professor Hardy Cross.
6/29/2012
Assumptions / Steps of this method:
1.
2.
3.
4.
5.
Assume that the water is withdrawn from nodes only; not
directly from pipes.
The discharge, Q , entering the system will have (+) value,
and the discharge, Q , leaving the system will have (-) value.
Usually neglect minor losses since these will be small with
respect to those in long pipes, i.e.; Or could be included as
equivalent lengths in each pipe.
Assume flows for each individual pipe in the network.
At any junction (node), as done for pipes in parallel,
Qin = Qout
6/29/2012
or
Q = 0
7
6.
Around any loop in the grid, the sum of head losses must
equal to zero:
hf = 0
loop
Conventionally, clockwise flows in a loop are considered (+) and
produce positive head losses; counterclockwise flows are then (-) and
produce negative head losses.
This fact is called the head balance of each loop, and this can be valid
only if the assumed Q for each pipe, within the loop, is correct.
The probability of initially guessing all flow rates correctly is
virtually null.
Therefore, to balance the head around each loop, a flow rate
correction () for each loop in the network should be
computed, and hence some iteration scheme is needed.
6/29/2012
7.
After finding the discharge correction, (one for each
loop) , the assumed discharges Q0 are adjusted and another
iteration is carried out until all corrections (values of )
become zero or negligible. At this point the condition of :
h f 0.0
loop
is satisfied.
Notes:
The flows in pipes common to two loops are positive in one
loop and negative in the other.
When calculated corrections are applied, with careful
attention to sign, pipes common to two loops receive both
corrections.
6/29/2012
How to find the correction value ( )
hF = kQ n
(1)
Q = Qo +
(2)
n = 2 Darcy, Manning
n = 1.85 Hazen William
from 1 & 2
hf = kQ = k (Qo + )
n
n(n 1) n 2 2
n
n 1
= k Qo + nQo +
Qo + ....
2
Neglect terms contains 2
hf = kQ n = k Qon + nQon 1
For each loop
n
h
kQ
=
F =0
loop
loop
kQ n = kQon + nkQ (n 1) = 0
6/29/2012
10
kQ on
nkQ o(n 1 )
h
h
n
Q
F
o
Note that if Hazen Williams (which is generally used in this method) is
used to find the head losses, then
h f = k Q1.85
(n = 1.85) , then
hf
185
.
hf
Q
If Darcy-Wiesbach is used to find the head losses, then
h f = k Q2
(n = 2) , then
=
6/29/2012
h f
2
hf
Q
11
Example
Solve the following pipe network using Hazen William Method CHW =100
63 L/s
1
24
.6
11.4
12
39
4
2
37.8 L/s
pipe
305m 150mm
25.2
305m 150mm
610m 200mm
457m 150mm
6/29/2012
153m
200mm
25.2 L/s
12
hf =
10.7 L
1.852
Q
C HW = 100, Q = in L/s
1.852
4.87
C HW
D
1.852
10.7 L
Q
hf =
1.852
4.87
1000
C HW
D
h f = 6.02 10 9 4.87 Q1.852
D
h f = {K }Q1.852
hF
0.28
1 =
=
= 0.24
hF 1.85(0.64)
n
Qo
6/29/2012
hF
0.45
2 =
=
= 0.57
hF 1.85(0.43)
n
Qo
for pipe 2 in loop 1
= 1 2
for pipe 2 in loop 2
13
= 2 1
1 =
hF
0.18
=
= 0.15
hF 1.85(0.64)
n
Qo
6/29/2012
1 =
hF
(0.07 )
=
= 0.09
hF 1.85(0.42)
n
Qo
for pipe 2 in loop 1
= 1 2
for pipe 2 in loop 2
= 2 1 14
General Notes
Occasionally the assumed direction of flow will be incorrect. In such
cases the method will produce corrections larger than the original
flow and in subsequent calculations the direction will be reversed.
Even when the initial flow assumptions are poor, the convergence
will usually be rapid. Only in unusual cases will more than three
iterations be necessary.
The method is applicable to the design of new system or to
evaluation of proposed changes in an existing system.
The pressure calculation in the above example assumes points are at
equal elevations. If they are not, the elevation difference must be
includes in the calculation.
The balanced network must then be reviewed to assure that the
velocity and pressure criteria are satisfied. If some lines do not meet
the
suggested criteria, it would be necessary to increase the
6/29/2012
15
diameters of these pipes and repeat the calculations.
Summary
Assigning clockwise flows and their associated head
losses are positive, the procedure is as follows:
Assume values of Q to satisfy Q = 0.
Calculate HL from Q using hf = K1Q2 .
If hf = 0, then the solution is correct.
If hf 0, then apply a correction factor, Q, to all
Q and repeat from step (2).
For practical purposes, the calculation is usually
terminated when hf < 0.01 m or Q < 1 L/s.
A reasonably efficient value of Q for rapid
convergence is given by;
Q =
H
H
2
L
L
L
L
6/29/2012
Q
16
Example
The following example contains nodes with different
elevations and pressure heads.
Neglecting minor loses in the pipes, determine:
The flows in the pipes.
The pressure heads at the nodes.
6/29/2012
17
Assume T= 150C
6/29/2012
18
Assume flows magnitude and direction
6/29/2012
19
First Iteration
Loop (1)
Pipe
L
(m)
D
(m)
Q
(m3/s)
hf
(m)
hf/Q
(m/m3/s)
AB
600
0.25
0.12
0.0157
11.48
95.64
BE
200
0.10
0.01
0.0205
3.38
338.06
EF
600
0.15
-0.06
0.0171
-40.25
670.77
FA
200
0.20
-0.10
0.0162
-8.34
83.42
-33.73
1187.89
6/29/2012
33.73
=
= 0.01419 m 3 /s = 14.20 L/s
2(1187.89)
20
First Iteration
Loop (2)
Pipe
L
(m)
D
(m)
Q
(m3/s)
hf
(m)
hf/Q
(m/m3/s)
BC
600
0.15
0.05
0.0173
28.29
565.81
CD
200
0.10
0.01
0.0205
3.38
338.05
DE
600
0.15
-0.02
0.0189
-4.94
246.78
EB
200
0.10
-0.01
0.0205
-3.38
338.05
23.35
1488.7
=
6/29/2012
23.35
= 0.00784 m 3 /s = 7.842 L/s
2(1488.7)
21
14.20
Second Iteration
14.20
14.20
7.84
Loop (1)
14.20
hf
(m)
hf/Q
(m/m3/s)
0.1342
0.0156
14.27
106.08
0.10
0.03204
0.0186
31.48
982.60
600
0.15
-0.0458
0.0174
-23.89
521.61
200
0.20
-0.0858
0.0163
-6.21
72.33
15.65
1682.62
Pipe
L
(m)
D
(m)
Q
(m3/s)
AB
600
0.25
BE
200
EF
FA
6/29/2012
15.65
=
= 0.00465 m 3 /s = 4.65 L/s
2(1682.62)
22
7.84
Second Iteration
14.20
7.84
7.84
Loop (2)
7.84
Pipe
L
(m)
D
(m)
Q
(m3/s)
hf
(m)
hf/Q
(m/m3/s)
BC
600
0.15
0.04216
0.0176
20.37
483.24
CD
200
0.10
0.00216
0.0261
0.20
93.23
DE
600
0.15
-0.02784
0.0182
-9.22
331.23
EB
200
0.10
-0.03204
0.0186
-31.48
982.60
-20.13
1890.60
=
6/29/2012
20.13
= 0.00532 m 3 /s = 5.32 L/s
2(1890.3)
23
Third Iteration
Loop (1)
Pipe
L
(m)
D
(m)
Q
(m3/s)
hf
(m)
hf/Q
(m/m3/s)
AB
600
0.25
0.1296
0.0156
13.30
102.67
BE
200
0.10
0.02207
0.0190
15.30
693.08
EF
600
0.15
-0.05045
0.0173
-28.78
570.54
FA
200
0.20
-0.09045
0.0163
-6.87
75.97
-7.05
1442.26
6/29/2012
7.05
=
= 0.00244 m 3 /s = 2.44 L/s
2(1442.26)
24
Third Iteration
Loop (2)
Pipe
L
(m)
D
(m)
Q
(m3/s)
hf
(m)
hf/Q
(m/m3/s)
BC
600
0.15
0.04748
0.0174
25.61
539.30
CD
200
0.10
0.00748
0.0212
1.96
262.11
DE
600
0.15
-0.02252
0.0186
-6.17
274.07
EB
200
0.10
-0.02207
0.0190
-15.30
693.08
6.1
1768.56
=
6/29/2012
6 .1
= 0.00172 m 3 /s = 1.72 L/s
2(1768.56)
25
After applying Third correction
6/29/2012
26
Velocity and Pressure Heads:
pipe
Q
(l/s)
V
(m/s)
hf
(m)
13.79
AB
131.99
2.689
13.79
BE
26.23
3.340
21.35
FE
48.01
2.717
26.16
AF
88.01
2.801
6.52
BC
45.76
2.589
23.85
CD
5.76
0.733
1.21
ED
24.24
1.372
7.09
6/29/2012
6.52
23.85
1.21
21.35
26.16
7.09
27
Velocity and Pressure Heads:
Node
p/+Z
(m)
Z
(m)
P/
(m)
13.79
70
30
40
56.21
25
31.21
32.36
20
12.36
21.35
6.52
31.15
20
11.15
37.32
22
15.32
63.48
25
38.48
6/29/2012
23.85
26.16
1.21
7.09
28
Example
For the square loop shown, find the discharge in all the pipes.
All pipes are 1 km long and 300 mm in diameter, with a friction
factor of 0.0163. Assume that minor losses can be neglected.
6/29/2012
29
Solution:
Assume values of Q to satisfy continuity equations all
at nodes.
The head loss is calculated using; HL = K1Q2
HL = hf + hLm
But minor losses can be neglected: hLm = 0
Thus
HL = hf
Head loss can be calculated using the Darcy-Weisbach
equation
L V2
hf =
D 2g
6/29/2012
30
L V2
HL = hf =
D 2g
1000
V2
H L = 0.0163 x
x
0.3 2 x 9.81
H L = 2.77
Q2
A
= 2.77 x
Q2
2
x 0.3
4
H L = 554Q 2
H L = K' Q 2
K ' = 554
First trial
Pipe
Q (L/s)
HL (m)
HL/Q
AB
60
2.0
0.033
BC
40
0.886
0.0222
CD
AD
-40
-0.886
0.0222
2.00
0.0774
Since HL > 0.01 m, then correction has to be applied.
6/29/2012
31
Q =
2
HL
=
= 12.92 L / s
HL
2
x
0
.
0774
2
Q
Second trial
Pipe
Q (L/s)
HL (m)
HL/Q
AB
47.08
1.23
0.0261
BC
27.08
0.407
0.015
CD
-12.92
-0.092
0.007
AD
-52.92
-1.555
0.0294
-0.0107
0.07775
Since HL 0.01 m, then it is OK.
Thus, the discharge in each pipe is as follows (to the nearest integer).
6/29/2012
Pipe
Discharge
(L/s)
AB
47
BC
27
CD
-13
AD
-53
32