TECHNICAL DATA
PRESSURE DROP CALCULATIONS
Stream
Service
Phase (*)
Temperature (C)
Pressure (barg)
Mass Flow (kg/h)
Flowing (m3/h)
Mole Weight
Flowing Density (kg/m3)
Line Sizing
Nominal Diameter (inch)
Pipe Int. Diameter (inch)
Design Factor
Fluid velocity (m/s)
Fluid viscosity (cP)
Reynolds No
e/D
Error (%)
Calc. Fanning Factor
Pressure Drop (psi/100ft)
Pressure Drop (mmWC/m)
Length, m
Pressure Drop (mmWC)
Pressure Drop Across Bend
Friction Coeff. for Bend
Delta P per bend
No. of bends Assumed
Pressure Drop across Bends
Total Presure Drop, mm WC
Line No.
1
2
3
4
5
6
7
8
9
10
11
12
13
14
Scrubber
Outlet
Case 1
AIR
V
40
0.105
50.00
40.34
28.80
1.24
Case 2
AIR
V
40
0.105
50.00
40.34
28.80
1.24
6
5.80
1.10
0.7
0.01
13,204
0.00031
-0.00786
0.00732
0.00
0.01
100.00
0.65
4
3.80
1.10
1.7
0.01
20,154
0.00048
-0.00388
0.00671
0.00
0.05
100.00
4.96
0.60
0.02
12.00
0.23
0.60
0.11
12.00
1.27
0.89
1.32
Pressure
Assumed
Assumed Duct Drop Across
Duct lengths
bends
Duct
mtrs
mmWC
Pressure
Drop Across
Duct
mmWC
Total
Pressure
Drop mmWC
Remarks