Zigbee Smart Meter System

The document describes a smart meter reading system that uses Zigbee wireless technology. An electronic energy meter connected to an opto-coupler counts pulses from energy consumption and sends the reading to a microcontroller. The microcontroller displays the reading on an LCD and sends it wirelessly to a PC using an XBee module. A step-down transformer, rectifier, and voltage regulator provide power for the system's operation.

Uploaded by

vivek
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as DOCX, PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
26 views2 pages

Zigbee Smart Meter System

The document describes a smart meter reading system that uses Zigbee wireless technology. An electronic energy meter connected to an opto-coupler counts pulses from energy consumption and sends the reading to a microcontroller. The microcontroller displays the reading on an LCD and sends it wirelessly to a PC using an XBee module. A step-down transformer, rectifier, and voltage regulator provide power for the system's operation.

Uploaded by

vivek
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as DOCX, PDF, TXT or read online on Scribd
You are on page 1/ 2

Smart Meter reading system using Zigbee

The main objective of the project is to develop an energy meter to communicate exact
billing that each load is going to consume with wireless technology.
An electronic energy meter that delivers unit based pulses is connected to an Opto-coupler
that counts the pulses every time the led glows. Depending upon the consumption it gives
required interrupt signal to a programmable micro controller of the 8051 family.
The microcontroller takes the reading from the energy meter via an Opto-isolator and
displays the reading on the LCD duly interfaced to the microcontroller. The reading of the
energy meter is sent wirelessly to the PC user by a serial data transfer through an 2.4 GHz
XBee module connected to the microcontroller.
The power supply consists of a step-down transformer 230/12V, which steps down the mains
voltage to 12V AC. This is converted to DC using a bridge rectifier and it is then regulated to
+5V using a voltage regulator 7805, which is required for the operation of the microcontroller
and other components.

[ Electromech Engineering Services , Nashik