ZR48K3E-PFJ

HFC, R-407C, Dew Point, 50 Hz, 1 - Phase, 220/240 V


Air Conditioning
Production Status: Available for sale to all U.S. customers. Please check with your local Emerson Climate Technologies representative
for international availability.

Performance

Mechanical

Evap(F)/Cond(F)
RG(F)/Liq(F)

45/130
65/115

45/100
65/85

Capacity (Btu/hr):
Power (Watts):
Current (Amps):
EER (Btu/Wh):
Mass Flow (lbs/hr):

38900
3710
17.9
10.5
565.0

47100
2490
12.7
18.9
585.0

Sound Power(dBA):
Vibration (mils(peak-peak)):
Record Date:

Number of Cylinders:
Bore Size (in):
Stroke (in):

0
0.0
0.0

Overall Length (in): 9.567


Overall Width (in): 9.567
Overall Height (in): 16.95

Displ (in^3/Rev):
Displ (ft^3/hr):

3.997
402.4739

Mounting Length (in): 7.5


Mounting Width(in):
7.5
Mounting Height (in): 17.18*

Suction Size (in):


7/8 Stub
Discharge Size (in):
1/2 Stub
Initial Oil Charge (oz):
42
Oil Recharge (oz):
38
Net Weight (lbs):
69.0
Internal Free Volume (in^3):
205.0
HorsePower
4.0
Overall
compressor
height
on
Copeland
Brand Product's specified
*
mounting grommets.

68 Ave 73 Max
2.0 Ave 3.0 Max
2005-04-15

Electrical
LRA-High*:
114.0
MCC (Amps):
27.0
UL File No.:
LRA-Half Winding:
RPM:
2900
UL File Date:
LRA-Low*:
105.0
Max Operating Current: 23.5
CSA File No.:
RLA(=MCC/1.4; use for contactor selection): 19.3
RLA (=MCC/1.56; use for breaker & wire size selection): 17.3
*Low and High refer to the low and high nominal voltage ranges for which the motor is approved.

Alternate Applications
Refrigerant
R-134a HFC
R-407C HFC
R-134a HFC

Frequency(Hz)
60
60
50

Thai Nair Equipment, Tel 02-282-3822, 281-6295.


5/18/2009

Phase

Voltage

Application

1
1
1

265
265
220/240

Air Conditioning
Air Conditioning
Air Conditioning

Page 1 of 1

Copyright 2008 Emerson Climate Technologies, Inc. All rights reserved.