24-27 - AC GENERATION MONITORING AND INDICATING
** ON A/C ALL
24-27 - AC GENERATION MONITORING AND INDICATING
24-27-00 - AC GENERATION MONITORING AND INDICATING
24-27-00 PB 001 CONF 00 - AC GENERATION MONITORING
AND INDICATING - DESCRIPTION AND OPERATION
1. General
The monitoring and indicating of the Alternating Current (AC) generation and distribution are performed by
means of the Electronic Centralized Aircraft Monitoring (ECAM) system on which are displayed the electrical
parameters concerning:
the four Integrated drive Generators (IDG)s,
the Auxiliary Power Unit (APU) generator,
the Constant Speed Motor/generator (CSM/G), (emergency generator),
the static inverter,
the two electrical ground power units.
2. System Description
The following AC electrical parameters can be read on AC ELEC page of the System Display (SD):
the oil outlet temperatures, the low oil pressure indication and the disconnection status of each IDG,
the voltage, frequency and nominal load in percentage of each main generator and APU generator,
the status of the AC normal and essential busbars,
the status of the galleys and the commercial loads, furthermore, the ECAM gives a synoptic of the AC
electrical generating system enabling the flight crew to be aware of the electrical configuration,
the voltage and frequency of the two ground power units, the emergency generator and the static inverter.
3. Operation/Control and Indicating
A. Operation
The AC ELEC page on the SD can be displayed:
either automatically after a class 1 failure on the AC network (if requested by the Flight Warning System
(FWS) ),
or manually by selecting the AC ELEC page on the ECAM control panel (Ref. 31-56-00).
B. Description
(Ref. Fig. ELEC AC System Page Description - System Display (SD))
Print Date: October 31, 2016
AIRBUS S.A.S. ALL RIGHTS RESERVED. CONFIDENTIAL AND PROPRIETARY DOCUMENT.
Page 1 of 19
Customer : MHK
Manual : AMM
Type : A340
Selected applicability : ALL
Rev. Date : Jul 01, 2016
24-27 - AC GENERATION MONITORING AND INDICATING
ELEC
AC
ESS
TR
EMER GEN
116v
400 HZ
STAT INV
116v
400 HZ
6
LND RCVRY
AC ESS
SHED
24
TR1
23
22
AC1-1
AC1-2
21
GEN1
GEN2
62%
116v
400 HZ
62%
116v
400 HZ
20
IDG1
123
LO PR
19
IDG2
123
LO PR
APU
TR
TR2
APU GEN
62%
116V
400HZ
EXT B
EXT A
116v
400 HZ
116v
400 HZ
AC2-3
AC2-4
GEN3
GEN4
10
62%
116v
400 HZ
62%
116v
400 HZ
IDG3
123
DISC
11
IDG4
123
DISC
12
GALLEY PARTIALLY SHED
18
13
2WK2
SD
17
16
15
14
F_MM_242700_0_AARA_01_00
Figure 24-27-00-13550-00-D / SHEET 1/2 - ELEC AC System Page Description - System Display (SD)
** ON A/C ALL
Print Date: October 31, 2016
AIRBUS S.A.S. ALL RIGHTS RESERVED. CONFIDENTIAL AND PROPRIETARY DOCUMENT.
Page 2 of 19
Customer : MHK
Manual : AMM
Type : A340
Selected applicability : ALL
Rev. Date : Jul 01, 2016
24-27 - AC GENERATION MONITORING AND INDICATING
26
27 28
29 30
32
31
33
34
35
52
36
ELEC
AC
51
ESS
TR
EMER GEN
116v
400 HZ
50
LND RCVRY
49
STAT INV
116v
400 HZ
AC ESS
SHED
TR1
48
37
APU
TR
TR2
38
AC1-1
AC1-2
AC2-3
AC2-4
GEN1
GEN2
GEN3
GEN4
62%
116v
400 HZ
62%
116v
400 HZ
62%
116v
400 HZ
62%
116v
400 HZ
39
47
46
IDG1
123
LO PR
45
IDG2
123
LO PR
APU GEN
62%
116V
400HZ
EXT B
EXT A
116v
400 HZ
116v
400 HZ
IDG3
123
DISC
40
41
IDG4
123
DISC
42
GALLEY PARTIALLY SHED
44
43
2WK2
SD
F_MM_242700_0_AARA_02_00
Figure 24-27-00-13550-00-D / SHEET 2/2 - ELEC AC System Page Description - System Display (SD)
** ON A/C ALL
Print Date: October 31, 2016
AIRBUS S.A.S. ALL RIGHTS RESERVED. CONFIDENTIAL AND PROPRIETARY DOCUMENT.
Page 3 of 19
Customer : MHK
Manual : AMM
Type : A340
Selected applicability : ALL
Rev. Date : Jul 01, 2016
24-27 - AC GENERATION MONITORING AND INDICATING
(1)
Generator 1 (item 21)
(Ref. Fig. ELEC AC System Page Description - System Display (SD))
(a)
When the generator 1 pushbutton switch is in the OFF position:
GEN indication is displayed in amber,
The number 1 of GEN 1 indication is displayed:
. in white when the engine is running or when the information is not available,
. in amber otherwise.
(b)
Digits for load, voltage and frequency are replaced by a white OFF indication.
When the GEN 1 pushbutton switch is in ON position or when the GEN pushbutton
switch position information is not available from GCU 1:
GEN is displayed:
. in amber when the GEN 1 is faulty upon detection by the GCU 1,
. in white otherwise.
The indication 1 of GEN 1 appears as specified previously.
Digits for the generator load (with 1 % accuracy) are displayed:
. in green normally,
. in amber when the generator is overloaded (GCU discrete information).
Digits for the generator voltage (with 1 V accuracy) are displayed:
. in green between 110 V and 120 V,
. in amber otherwise.
Digits for the generator frequency (with 1 Hz accuracy) are displayed:
. in green between 390 Hz and 410 Hz,
. in amber otherwise.
NOTE: The digits for the generator load, voltage and frequency are replaced by amber XX as soon
as information from GCU are unavailable.
(2)
Generator 2 (item 20)
(3)
Same principle as for generator 1.
Generator 3 (item 11)
(4)
Same principle as for generator 1.
Generator 4 (item 10)
(5)
Same principle as for generator 1.
APU generator (item 16)
(a)
When the APU is in the standby mode: the MASTER switch is in OFF position and the
APU not available as detected by the Electronic Control Box (ECB) or in an unknown
status:
(b)
APU GEN is displayed in white.
When the APU is not in standby mode and the APU GEN pushbutton switch is in OFF
position:
APU GEN is displayed in amber,
Print Date: October 31, 2016
AIRBUS S.A.S. ALL RIGHTS RESERVED. CONFIDENTIAL AND PROPRIETARY DOCUMENT.
Page 4 of 19
Customer : MHK
Manual : AMM
Type : A340
Selected applicability : ALL
Rev. Date : Jul 01, 2016
24-27 - AC GENERATION MONITORING AND INDICATING
(c)
Digits for load, voltage and frequency are replaced by a white OFF indication.
When:
. the APU is not in standby mode,
. the APU GEN pushbutton switch is in ON position or its position is unknown,
. or the APU MASTER switch position is unavailable.
APU GEN is displayed:
. in white normally,
. in amber when the APU generator is faulty upon detection of the GAPCU.
Digits for load, voltage and frequency:
. They are displayed according to the same principle as for generator 1.
(6)
CSM/G (emergency generator)
(a)
When the emergency generator line contactor (EMER GLC) is open:
EMER GEN is displayed in white if the EMER GEN is not fault, in amber otherwise,
digits for voltage and frequency are not displayed.
(b)
When the EMER GLC is closed or when its position information is not available:
EMER GEN is displayed:
. in white normally,
. in amber when the CSM/G is faulty upon detection by discrete or analog inputs
wired on the SDAC.
digits for voltage and frequency:
. Same principle as for generator 1.
Static Inverter (item 5)
(7)
(8)
Same principle as for the CSM/G, but using 3XB contactor.
External power A
The box is displayed only when the aircraft is on the ground:
(a)
when the EXT PWR A is not available nor ON as detected by the GAPCU :
(b)
EXT A is displayed in white.
when the EXT POWER A is available or ON, or the information unavailable:
EXT A is displayed in white,
Digits for voltage and frequency:
. They are displayed according to the same principle as for generator 1 using
GAPCU information.
External Power B
(9)
Same principle as for External Power A.
(10)
AC busbars
(Ref. Fig. ELEC AC System Page Description - System Display (SD))
(a)
1
AC 1-1 busbar (item 22)
In amber when:
Print Date: October 31, 2016
AIRBUS S.A.S. ALL RIGHTS RESERVED. CONFIDENTIAL AND PROPRIETARY DOCUMENT.
Page 5 of 19
Customer : MHK
Manual : AMM
Type : A340
Selected applicability : ALL
Rev. Date : Jul 01, 2016
24-27 - AC GENERATION MONITORING AND INDICATING
the Electrical Contactor Management Unit (ECMU) or FWC indicates that there is no voltage on
the busbar 1XP1.
In green when:
the ECMU indicates that the busbar 1XP1 is power supplied.
3
(b)
As there is no available data from the ECMU.
Replaced by amber XX when there is no refreshed data from the ECMU nor
from FWC.
AC1-2 busbar (item 23)
(c)
Same principle as for AC 1-1.
AC 2-3 busbar (item 7)
(d)
Same principle as for AC 1-1.
AC 2-4 busbar (item 9)
(e)
Same principle as for AC 1-1.
AC ESS busbar (item 2):
(11)
in green normally,
in amber when there is no voltage on busbar 901XP,
replaced by amber XX when busbar 901XP status information is not available from the System
Data Analog Concentrator (SDAC).
AC power transformers
(Ref. Fig. ELEC AC System Page Description - System Display (SD))
(a)
TR1 (item 24):
in white normally,
in amber when:
. the TR1 voltage or current are in abnormal values (voltage out of limits (25 V, 31
V) or current below 2 A),
. or the TR1 is faulty upon discrete information.
(b)
TR2 (item 6)
(c)
Same principle as for TR1.
ESS TR (item 3)
(d)
Same principle as for TR1.
APU TR (item 8)
(12)
Same principle as for TR1, except that the voltage or the current abnormal values are not considered
during the APU start.
Integrated drive generator
(Ref. Fig. ELEC AC System Page Description - System Display (SD))
(a)
1
IDG 1 (item 19)
IDG is displayed:
in white normally,
in amber in case of:
Print Date: October 31, 2016
AIRBUS S.A.S. ALL RIGHTS RESERVED. CONFIDENTIAL AND PROPRIETARY DOCUMENT.
Page 6 of 19
Customer : MHK
Manual : AMM
Type : A340
Selected applicability : ALL
Rev. Date : Jul 01, 2016
24-27 - AC GENERATION MONITORING AND INDICATING
. IDG oil outlet temperature overheat,
. or IDG oil low pressure detection
. or in case of IDG disconnection.
Number 1 of IDG 1 is displayed:
2
in white when:
. the engine is running,
. or when the information is not available.
in amber otherwise.
Digits for IDG oil outlet temperature (with 1 % accuracy) are displayed:
in green normally,
in green, pulsing, in case of advisory from GCU (151 C + or - 3 C),
in amber in case of overheat detection upon detection by the GCU (185 C + or - 5 C).
NOTE: The values dealt with above paragraph 3_ are replaced by amber XX when the data are
not available from the GCU.
(b)
DISC indication is displayed:
in amber when the IDG 1 is disconnected as detected by the GCU,
nothing otherwise.
LO PR indication is displayed:
in amber when an IDG oil low pressure detected by switch occurs as the IDG is rotating,
nothing otherwise.
IDG 2 (Item 18)
(c)
Same principle as for IDG 1.
IDG 3 (item 13)
(d)
Same principle as for IDG 1.
IDG 4 (item 12)
(13)
Same principle as for IDG 1.
Messages
(Ref. Fig. ELEC AC System Page Description - System Display (SD))
(a)
SHED message (item 4):
in amber when there is no voltage on the AC ESS SHED busbar (401XP),
nothing otherwise.
(b)
COMMERCIAL OFF or GALLEY SHED or GALLEY PARTIALLY SHED message is
displayed item 15):
in white upon discrete information from ECMU, with respect to the display priority order given
above,
nothing otherwise.
(c)
LAND RCVRY message (item 26):
(14)
in green when the land recovery discrete information is true,
nothing otherwise.
AC connections
Print Date: October 31, 2016
AIRBUS S.A.S. ALL RIGHTS RESERVED. CONFIDENTIAL AND PROPRIETARY DOCUMENT.
Page 7 of 19
Customer : MHK
Manual : AMM
Type : A340
Selected applicability : ALL
Rev. Date : Jul 01, 2016
24-27 - AC GENERATION MONITORING AND INDICATING
(a)
Item (48)
Appears in green when the contactor 3XC1 is closed, or when the BTC1 and the (BTC2 with (GLC1
or GLC2), or EPCB or APU GLC or SIC) contactors are closed. Nothing otherwise.
(b)
Item (49)
Appears in green when the BTC2 and the (BTC1 with GLC1 or GLC2), or EPCB or APU GLC or
SIC) contactors are closed.
Nothing otherwise.
(c)
Item (37)
Appears in green when the BTC3 and the (BTC4 with (GLC3 or GLC4), or EPCA or SIC) contactors
are closed.
Nothing, otherwise.
(d)
Item (36)
Appears in green when the contactor 3XC2 is closed, or when the BTC4 and the BTC3 with (GLC3
or GLC4), or EPCA or SIC) contactors are closed.
Nothing, otherwise.
(e)
Item (38)
Appears in green when the APU GLC and the (SIC with (BTC3 or BTC4) or BTC1 or BTC2)
contactors are closed.
Nothing otherwise.
(f)
Item (28)
Appears in green when the EMER GLC contactor is closed.
Nothing, otherwise.
(g)
Item (30)
Appears in green when the contactor 3XB is closed.
Nothing, otherwise.
(h)
Item (42)
Appears in green when the EPCA and the (SIC with (BTC1 or BTC2) or BTC3 or BTC4) contactors
are closed.
Nothing, otherwise.
(i)
Item (45)
Appears in green when the EPCB and the (SIC with (BTC3 or BTC4) or BTC1 or BTC2) contactors
are closed.
Nothing, otherwise.
(j)
Item (52)
Appears in green when the contactor 3XC1 is closed.
Nothing, otherwise.
(k)
Item (34)
Appears in green when the contactor 3XC2 is closed.
Nothing, otherwise.
(l)
Item (29)
Appears in green when the EMER GLC or 3XB or 3XC1 or 3XC2 contactor is closed. Nothing,
otherwise.
Print Date: October 31, 2016
AIRBUS S.A.S. ALL RIGHTS RESERVED. CONFIDENTIAL AND PROPRIETARY DOCUMENT.
Page 8 of 19
Customer : MHK
Manual : AMM
Type : A340
Selected applicability : ALL
Rev. Date : Jul 01, 2016
24-27 - AC GENERATION MONITORING AND INDICATING
(m)
Item (50)
Appears in green when the BTC1 and the (BTC2 with (GLC1 or GLC2), or EPCB or APU GLC or
SIC) contactors are closed.
Nothing, otherwise.
(n)
Item (51)
Appears in green when the (BTC1 or BTC2) and the (EPCB or APU GLC or SIC) contactors are
closed.
Nothing, otherwise.
(o)
Item (26)
Appears in green when the (BTC1 or BTC2) and the ( APU GLC or SIC), or the (EPCB and SIC with
BTC3 or BTC4) contactors are closed.
Nothing otherwise.
(p)
Item (32)
Does not appears when the SIC is open or when it is closed with the (EPCA neither BTC1, nor
BTC2) contactors closed, or with the (APU GLC or EPCB), and neither BTC3, nor BTC4) contactors
closed.
In green, otherwise.
(q)
Item (33)
Appears in green when the (BTC3 or BTC4 ) and the (SIC or EPCA) contactors are closed.
Nothing, otherwise.
(r)
Item (35)
Appears in green when the BTC4 and the (BTC3 with (GLC3 or GLC4), or EPCA or SIC) contactors
are closed.
Nothing, otherwise.
(s)
Item (47)
Appears in green when the GLC1 is closed.
Nothing otherwise.
(t)
Item (46)
Appears in green when the GLC2 is closed.
Nothing, otherwise.
(u)
Item (40)
Appears in green when the GLC3 is closed.
Nothing, otherwise.
(v)
Item (39)
Appears in green when the GLC4 is closed.
Nothing otherwise.
(w)
Item (41)
Appears in green when the APU GLC and (SIC and (BTC3 or BTC4) or BTC1 or BTC2) contactors
are closed. In white otherwise.
(x)
Item (27)
Appears in green when the EMER GLC is closed.
Appears in white when the EMER GLC is open or in an unknown position.
Print Date: October 31, 2016
AIRBUS S.A.S. ALL RIGHTS RESERVED. CONFIDENTIAL AND PROPRIETARY DOCUMENT.
Page 9 of 19
Customer : MHK
Manual : AMM
Type : A340
Selected applicability : ALL
Rev. Date : Jul 01, 2016
24-27 - AC GENERATION MONITORING AND INDICATING
(y)
Item (31)
Appears in green when the contactor 3XB is closed.
Appears in white when the contactor 3XB is open or in an unknown position.
(z)
Item (43)
Appears in green when the EPCA and (SIC and (BTC1 or BTC2) or BTC3 or BTC4) contactors are
closed.
In white, otherwise.
(aa)
Item (44)
appears in green when the EPCB and (SIC and (BTC3 or BTC4) or BTC1 or BTC2) contactors are
closed.
In white, otherwise.
All the connection lines described in this section are not displayed when the contactor status
information are not available from ECMU or SDAC.
Figure 24-27-00-13550-00-D / SHEET 1/2 - ELEC AC System Page Description - System Display (SD)
Figure 24-27-00-13550-00-D / SHEET 2/2 - ELEC AC System Page Description - System Display (SD)
24-27-00 PB 401 CONF 00 - AC GENERATION MONITORING
AND INDICATING - DEACTIVATION/REACTIVATION
TASK 24-27-00-040-801-A
Check of AC Loads Indications and Automatic Galley Shedding
Task Summary
MMEL or CDL Ref
MMEL 24-01-01-11A
Access
YES
Test
NO
1.
Reason for the Job
MMEL 24-01-01-11A
GALLEY FAULT
(OLD Reference: MMEL242701Ea)
Job Set-up Information
A.
Mhr
00.8
E/T
00.5
Nb Men
1
Fixtures, Tools, Test and Support Equipment
REFERENCE
No specific
B.
Specific Tools
NO
QTY DESIGNATION
AR ACCESS PLATFORM 3M (10 FT)- ADJUSTABLE
Work Zones and Access Panels
ZONE/ACCESS
811
ZONE DESCRIPTION
C. Referenced Information
REFERENCE
(Ref. 31-60-00-860-801-A).
DESIGNATION
EIS Start Procedure
Print Date: October 31, 2016
AIRBUS S.A.S. ALL RIGHTS RESERVED. CONFIDENTIAL AND PROPRIETARY DOCUMENT.
Page 10 of 19
Customer : MHK
Manual : AMM
Type : A340
Selected applicability : ALL
Rev. Date : Jul 01, 2016
24-27 - AC GENERATION MONITORING AND INDICATING
REFERENCE
(Ref. 31-60-00-860-802-A).
(Ref. 49-00-00-860-805-A).
(Ref. 49-00-00-860-805-A-01).
(Ref. 49-00-00-860-806-A).
DESIGNATION
EIS Stop Procedure
Start of the APU with Power Supply from the APU Battery (331-600(A))
Start of the APU with External Power (331-600(A))
Shutdown of the APU with Power Supply from the APU Battery
(331-600(A))
(Ref. 49-00-00-860-806-A-01).
Shutdown of the APU with External Power (331-600(A))
(Ref. 71-00-00-860-845-A).
The Procedure to Start the Engine - Automatic Start
(Ref. 71-00-00-860-846-A).
The Procedure to Start the Engine - Manual (Alternative) Start
(Ref. 71-00-00-860-847-A).
The Procedure to Shutdown the Engine
Location of the AC/DC CNTOR Box 715VU, the Ground/Flight AC C/B and RCCB Center Panel 725VU
and the Left(Right) AC CNTOR and RCCB Lateral Box 717VU(718VU) SHEET 1
Print Date: October 31, 2016
AIRBUS S.A.S. ALL RIGHTS RESERVED. CONFIDENTIAL AND PROPRIETARY DOCUMENT.
Page 11 of 19
Customer : MHK
Manual : AMM
Type : A340
Selected applicability : ALL
Rev. Date : Jul 01, 2016
24-27 - AC GENERATION MONITORING AND INDICATING
FR18
FR16
A
710VU
718VU
717VU
715VU
725VU
F_MM_242700_4_KAM0_01_00
Figure 24-27-00-991-00100-00-B / SHEET 1/1 - Location of the AC/DC
CNTOR Box 715VU, the Ground/Flight AC C/B and RCCB Center Panel
725VU and the Left(Right) AC CNTOR and RCCB Lateral Box 717VU(718VU)
** ON A/C ALL
Print Date: October 31, 2016
AIRBUS S.A.S. ALL RIGHTS RESERVED. CONFIDENTIAL AND PROPRIETARY DOCUMENT.
Page 12 of 19
Customer : MHK
Manual : AMM
Type : A340
Selected applicability : ALL
Rev. Date : Jul 01, 2016
24-27 - AC GENERATION MONITORING AND INDICATING
3.
Job Set-up
Subtask 24-27-00-860-050-C
A.
Aircraft Maintenance Configuration
(1) On the overhead panel, on the ELEC control panel 235VU:
make sure that the ELMU pushbutton switch is pushed (the OFF legend is off),
make sure that the ELEC/GALLEY pushbutton switch is pushed (the OFF legend is off),
make sure that the ELEC/COMMERCIAL pushbutton switch is pushed (the OFF legend is off),
make sure that the ELEC/BAT 1(2) pushbutton switch is pushed (the OFF legend is off),
make sure that the ELEC/GEN 1(2,3,4) and ELEC/APU GEN pushbutton switch is pushed (the
OFF legend is off).
(2) Start the APU (Ref. AMM TASK 49-00-00-860-805) .
(3) Do the EIS start procedure (only EWD and SD)
(Ref. AMM TASK 31-60-00-860-801) .
Subtask 24-27-00-010-050-A
B.
Get Access to the Avionics Compartment
(1) Put an ACCESS PLATFORM 3M (10 FT)- ADJUSTABLE in position at the access door 811.
(2) Open the access door 811.
4.
Procedure
(Ref. Fig. Location of the AC/DC CNTOR Box 715VU, the Ground/Flight AC C/B and RCCB Center Panel
725VU and the Left(Right) AC CNTOR and RCCB Lateral Box 717VU(718VU) SHEET 1)
Subtask 24-27-00-710-050-K
A.
Check of AC Load Indications and Automatic Galley Shedding
ACTION
1.Start the engine 1(2,3,4)
(Ref. AMM TASK 71-00-00-860-845) or
(Ref. AMM TASK 71-00-00-860-846) .
2.On the ECAM control panel:
push the EL/AC key to get the ELEC AC page.
RESULT
On the SD, the ELEC AC page comes into view.
Make sure that the load parameters are different from
0%.
3.On the overhead panel, on the ELEC control pan- On the overhead panel, on the ELEC control panel
el 235VU:
235VU:
release the ELEC/APU GEN pushbutton switch. the OFF legend of the ELEC/APU GEN pushbutton
switch comes on.
On the SD, on the ELEC AC page:
the GALLEY SHED indication comes into view.
On the left AC contactor and RCCB lateral box
717VU:
on the front face of the RCCBs 1, 2, 9 and 11
(11MC, 111MC, 15MC and 117MC), the visual
state indication shows OPEN.
On the AC/DC contactor box 715VU:
on the front face of the RCCBs 3, 4, 7, 8 and 12
(12MC, 23MC, 112MC, 223MC and 116MC), the
visual state indication shows OPEN.
On the right AC contactor and RCCB lateral box
718VU:
Print Date: October 31, 2016
AIRBUS S.A.S. ALL RIGHTS RESERVED. CONFIDENTIAL AND PROPRIETARY DOCUMENT.
Page 13 of 19
Customer : MHK
Manual : AMM
Type : A340
Selected applicability : ALL
Rev. Date : Jul 01, 2016
24-27 - AC GENERATION MONITORING AND INDICATING
ACTION
RESULT
on the front face of the RCCBs 5 and 6 (24MC and
224MC), the visual state indication shows OPEN.
On the ground/flight AC C/B and RCCB center panel
725VU:
on the front face of the RCCB 10 (115MC), the
visual state indication shows OPEN.
4.On the overhead panel, on the ELEC control pan- On the overhead panel, on the ELEC control panel
el 235VU:
235VU:
push the ELEC/APU GEN pushbutton switch.
the OFF legend of the ELEC/APU GEN pushbutton
switch goes off.
On the SD, on the ELEC AC page:
the GALLEY SHED indication goes out of view.
On the left AC contactor and RCCB lateral box
717VU:
on the front face of the RCCBs 1, 2, 9 and 11
(11MC, 111MC, 15MC and 117MC), the visual
state indication shows CLOSED.
On the AC/DC contactor box 715VU:
on the front face of the RCCBs 3, 4, 7, 8 and 12
(12MC, 23MC, 112MC, 223MC and 116MC), the
visual state indication shows CLOSED.
On the right AC contactor and RCCB lateral box
718VU:
on the front face of the RCCBs 5 and 6 (24MC
and 224MC), the visual state indication shows
CLOSED.
On the ground/flight AC C/B and RCCB center panel
725VU:
on the front face of the RCCB 10 (115MC), the
visual state indication shows CLOSED.
5.Stop the engine 1(2,3,4)
(Ref. AMM TASK 71-00-00-860-847) .
5.
Close-up
Subtask 24-27-00-410-050-A
A.
Close Access
(1) Close the access door 811.
(2) Remove the access platform(s).
Subtask 24-27-00-860-051-B
B.
Put the Aircraft back to its Initial Configuration
(1) Do the EIS stop procedure
(Ref. AMM TASK 31-60-00-860-802) .
(2) On the overhead panel, on the ELEC control panel 235VU:
release the ELMU pushbutton switch (the OFF legend comes on).
(3) Stop the APU (Ref. AMM TASK 49-00-00-860-806) .
(4) Make an entry in the log book.
TASK 24-27-00-040-802-A
Print Date: October 31, 2016
AIRBUS S.A.S. ALL RIGHTS RESERVED. CONFIDENTIAL AND PROPRIETARY DOCUMENT.
Page 14 of 19
Customer : MHK
Manual : AMM
Type : A340
Selected applicability : ALL
Rev. Date : Jul 01, 2016
24-27 - AC GENERATION MONITORING AND INDICATING
Check of AC Generation Indications and Automatic Galley Shedding
Task Summary
MMEL or CDL Ref
MMEL 24-07-01-01A
Access
YES
Test
NO
1.
Reason for the Job
MMEL 24-07-01-01A
AC Generation Indications on the ELEC AC
(OLD Reference: MMEL242701Jb)
Job Set-up Information
A.
Mhr
00.8
E/T
00.5
Nb Men
1
Fixtures, Tools, Test and Support Equipment
REFERENCE
No specific
B.
Specific Tools
NO
QTY DESIGNATION
AR ACCESS PLATFORM 3M (10 FT)- ADJUSTABLE
Work Zones and Access Panels
ZONE/ACCESS
811
ZONE DESCRIPTION
C. Referenced Information
REFERENCE
(Ref. 31-60-00-860-801-A).
(Ref. 31-60-00-860-802-A).
(Ref. 49-00-00-860-805-A).
(Ref. 49-00-00-860-805-A-01).
(Ref. 49-00-00-860-806-A).
DESIGNATION
EIS Start Procedure
EIS Stop Procedure
Start of the APU with Power Supply from the APU Battery (331-600(A))
Start of the APU with External Power (331-600(A))
Shutdown of the APU with Power Supply from the APU Battery
(331-600(A))
(Ref. 49-00-00-860-806-A-01).
Shutdown of the APU with External Power (331-600(A))
(Ref. 71-00-00-860-845-A).
The Procedure to Start the Engine - Automatic Start
(Ref. 71-00-00-860-846-A).
The Procedure to Start the Engine - Manual (Alternative) Start
(Ref. 71-00-00-860-847-A).
The Procedure to Shutdown the Engine
Location of the AC/DC CNTOR Box 715VU, the Ground/Flight AC C/B and RCCB Center Panel 725VU
and the Left(Right) AC CNTOR and RCCB Lateral Box 717VU(718VU) SHEET 1
Print Date: October 31, 2016
AIRBUS S.A.S. ALL RIGHTS RESERVED. CONFIDENTIAL AND PROPRIETARY DOCUMENT.
Page 15 of 19
Customer : MHK
Manual : AMM
Type : A340
Selected applicability : ALL
Rev. Date : Jul 01, 2016
24-27 - AC GENERATION MONITORING AND INDICATING
FR18
FR16
A
710VU
718VU
717VU
715VU
725VU
F_MM_242700_4_KAM1_01_00
Figure 24-27-00-991-00200-00-B / SHEET 1/1 - Location of the AC/DC
CNTOR Box 715VU, the Ground/Flight AC C/B and RCCB Center Panel
725VU and the Left(Right) AC CNTOR and RCCB Lateral Box 717VU(718VU)
** ON A/C ALL
Print Date: October 31, 2016
AIRBUS S.A.S. ALL RIGHTS RESERVED. CONFIDENTIAL AND PROPRIETARY DOCUMENT.
Page 16 of 19
Customer : MHK
Manual : AMM
Type : A340
Selected applicability : ALL
Rev. Date : Jul 01, 2016
24-27 - AC GENERATION MONITORING AND INDICATING
3.
Job Set-up
Subtask 24-27-00-860-052-C
A.
Aircraft Maintenance Configuration
(1) On the overhead panel, on the ELEC control panel 235VU:
make sure that the ELMU pushbutton switch is pushed (the OFF legend is off),
make sure that the ELEC/GALLEY pushbutton switch is pushed (the OFF legend is off),
make sure that the ELEC/COMMERCIAL pushbutton switch is pushed (the OFF legend is off),
make sure that the ELEC/BAT 1(2) pushbutton switch is pushed (the OFF legend is off),
make sure that the ELEC/GEN 1(2,3,4) pushbutton switch is released (the OFF legend is on),
make sure that the ELEC/APU GEN pushbutton switch is pushed (the OFF legend is off).
(2) Start the APU (Ref. AMM TASK 49-00-00-860-805) .
(3) Do the EIS start procedure (only EWD and SD)
(Ref. AMM TASK 31-60-00-860-801) .
Subtask 24-27-00-010-051-A
B.
Get Access to the Avionics Compartment
(1) Put an ACCESS PLATFORM 3M (10 FT)- ADJUSTABLE in position at the access door 811.
(2) Open the access door 811.
4.
Procedure
(Ref. Fig. Location of the AC/DC CNTOR Box 715VU, the Ground/Flight AC C/B and RCCB Center Panel
725VU and the Left(Right) AC CNTOR and RCCB Lateral Box 717VU(718VU) SHEET 1)
Subtask 24-27-00-710-051-K
A.
Check of AC Generation Indications and Automatic Galley Shedding
ACTION
RESULT
1.On the overhead panel, on the ELEC control pan- On the overhead panel, on the ELEC control panel
el 235VU:
235VU:
push the ELEC/GEN 1(2,3,4) pushbutton switch. the FAULT legend of the ELEC/GEN 1(2,3,4)
pushbutton switch comes on.
2.Start the engine 1(2,3,4)
the FAULT legend of the ELEC/GEN 1(2,3,4)
(Ref. AMM TASK 71-00-00-860-845) or
pushbutton switch goes off.
(Ref. AMM TASK 71-00-00-860-846) .
3.On the ECAM control panel:
On the SD, the ELEC AC page comes into view.
push the EL/AC key to get the ELEC AC page.
On the SD, on the ELEC AC page, make sure that a
minimum of one IDG operates (The load, voltage and
frequency indications are shown).
4.On the overhead panel, on the ELEC control pan- On the overhead panel, on the ELEC control panel
el 235VU:
235VU:
release the ELEC/APU GEN pushbutton switch. the OFF legend of the ELEC/APU GEN pushbutton
switch comes on.
On the SD, on the ELEC AC page:
the GALLEY SHED indication comes into view.
On the left AC contactor and RCCB lateral box
717VU:
on the front face of the RCCBs 1, 2, 9 and 11
(11MC, 111MC, 15MC and 117MC), the visual
state indication shows OPEN.
On the AC/DC contactor box 715VU:
Print Date: October 31, 2016
AIRBUS S.A.S. ALL RIGHTS RESERVED. CONFIDENTIAL AND PROPRIETARY DOCUMENT.
Page 17 of 19
Customer : MHK
Manual : AMM
Type : A340
Selected applicability : ALL
Rev. Date : Jul 01, 2016
24-27 - AC GENERATION MONITORING AND INDICATING
ACTION
RESULT
on the front face of the RCCBs 3, 4, 7, 8 and 12
(12MC, 23MC, 112MC, 223MC and 116MC), the
visual state indication shows OPEN.
On the right AC contactor and RCCB lateral box
718VU:
on the front face of the RCCBs 5 and 6 (24MC and
224MC), the visual state indication shows OPEN.
On the ground/flight AC C/B and RCCB center panel
725VU:
on the front face of the RCCB 10 (115MC), the
visual state indication shows OPEN.
5.On the overhead panel, on the ELEC control pan- On the overhead panel, on the ELEC control panel
el 235VU:
235VU:
push the ELEC/APU GEN pushbutton switch.
the OFF legend of the ELEC/APU GEN pushbutton
switch goes off.
On the SD, on the ELEC AC page:
the GALLEY SHED indication goes out of view.
On the left AC contactor and RCCB lateral box
717VU:
on the front face of the RCCBs 1, 2, 9 and 11
(11MC, 111MC, 15MC and 117MC), the visual
state indication shows CLOSED.
On the AC/DC contactor box 715VU:
on the front face of the RCCBs 3, 4, 7, 8 and 12
(12MC, 23MC, 112MC, 223MC and 116MC), the
visual state indication shows CLOSED.
On the right AC contactor and RCCB lateral box
718VU:
on the front face of the RCCBs 5 and 6 (24MC
and 224MC), the visual state indication shows
CLOSED.
On the ground/flight AC C/B and RCCB center panel
725VU:
on the front face of the RCCB 10 (115MC), the
visual state indication shows CLOSED.
6.Stop the engine 1(2,3,4)
(Ref. AMM TASK 71-00-00-860-847) .
5.
Close-up
Subtask 24-27-00-410-051-A
A.
Close Access
(1) Close the access door 811.
(2) Remove the access platform(s).
Subtask 24-27-00-860-053-B
B.
Put the Aircraft back to its Initial Configuration
(1) Do the EIS stop procedure
(Ref. AMM TASK 31-60-00-860-802) .
(2) On the overhead panel, on the ELEC control panel 235VU:
release the ELMU pushbutton switch (the OFF legend comes on).
Print Date: October 31, 2016
AIRBUS S.A.S. ALL RIGHTS RESERVED. CONFIDENTIAL AND PROPRIETARY DOCUMENT.
Page 18 of 19
Customer : MHK
Manual : AMM
Type : A340
Selected applicability : ALL
Rev. Date : Jul 01, 2016
24-27 - AC GENERATION MONITORING AND INDICATING
(3) Stop the APU (Ref. AMM TASK 49-00-00-860-806) .
(4) Make an entry in the log book.
Figure 24-27-00-991-00100-00-B / SHEET 1/1 - Location of the AC/DC CNTOR Box 715VU, the Ground/Flight AC
C/B and RCCB Center Panel 725VU and the Left(Right) AC CNTOR and RCCB Lateral Box 717VU(718VU)
Figure 24-27-00-991-00200-00-B / SHEET 1/1 - Location of the AC/DC CNTOR Box 715VU, the Ground/Flight AC
C/B and RCCB Center Panel 725VU and the Left(Right) AC CNTOR and RCCB Lateral Box 717VU(718VU)
End of document