CT 3306/665 3~ 631
Especificacin tcnica
[m] Altura de impulsin
36
35
34
33
32
31
30
29
28
27
26
25
24
23
22
21
20
19
18
17
16
15
14
13
12
11
10
9
8
7
6
-5
4
3
2
1
0
0
400
84,1%
631 460mm
Note: Picture might not correspond to the current configuration.
General
Bom bas con im pulsor de canal sim ple o m ulticanal con pasos de esf era grandes
Im pulsores f abricados en hierro f undido y algunos tam bien en acero inoxidable.
Impulsor
800
1200
1600
[m/h]
Curve according to: ISO 9906
Im peller m aterial
D iam . de salida
Inlet diam eter
Im peller diam eter
N um ber of blades
D im etro paso de esf era
Stainless steel
300 m m
350 m m
460 m m
3
104 m m
Installation: T - Vertical permanente, En seco
M otor
28(4X)
70
850
11.25
M20(16X)
Y -Y
650
G3/4
30
1890
24(4X)
65
1820
255*
300
Y
1025
805
330
DN
V IE W
X -X
ISO
FOR COOLING JACKET DRAIN
460
V IE W
NOT DELIVERED BY FLYGT
990
850
THRE A DE D HOLE S
X
DN
MIN
TO S UMP
C 0665.000 35-45-6AA-D 90KW
1
50 H z
400 V
6
3~
90 kW
185 A
1160 A
985 1/m in
Motor #
Variante de estator
Frecuencia
Tensin nom inal
N de polos
Fases
Potencia nom inal
C orriente nom inal
C orriente de arranque
Velocidad nom inal
Factor de potencia
1/1 Load
3/4 Load
1/2 Load
Ef iciencia
1/1 Load
3/4 Load
1/2 Load
0,76
0,70
0,57
92,0 %
92,5 %
91,5 %
Configuracin
400
650
525
P INS TO A NCHOR P E DE S TA LS
435 325
NOTE :
P UMP CA N B E ROTA TE D A B OUT ITS CE NTE RLINE
TO 4 P OS ITIONS RE LA TIV E TO THE INLE T E LB OW.
INCRE ME NTS A RE 90 .
* DIME NS ION TO INLE T E LB OW FLA NGE
160
400
Dimensional drwg
CT,NT 3306 665/675
Of f erta
ID of f erta
Creato da
Creato il
2013-09-25
Ultimo aggiornamento
CT 3306/665 3~ 631
Curv a de funcionamiento
Bomba
M otor
Diam. de salida
Inlet diameter
Impeller diameter
Number of blades
Dimetro paso de esfera
[m]
300 mm
350 mm
460 mm
3
104 mm
Motor #
Stator variant
Frecuencia
Rated voltage
N de polos
Fases
Potencia nominal
Corriente nominal
Corriente de arranque
Velocidad nominal
C0665.000 35-45-6AA-D 90KW
1
50 Hz
400 V
6
3~
90 kW
185 A
1160 A
985 1/min
Factor de potencia
1/1 Load
0,76
3/4 Load
0,70
1/2 Load
0,57
Eficiencia
1/1 Load
3/4 Load
1/2 Load
92,0 %
92,5 %
91,5 %
Altura de impulsin
34
32
30
28
26
24
22
21,3 m
20
84,1%
18
16
14
12
10
631 460mm
8
6
4
2
0
[%] Eficiencia
Eficiencia total
60
83,6 %
77,3 %
631
631 460mm
460mm
40
20
0
[kW] Potencia en el eje motor P2
Potencia absorbida P1
60
78,4 kW
631 460mm (P1)
631 460mm (P2)
72,6 kW
40
20
0
[m] Valores NPSH
631 460mm
10
8
6
4
3,78 m
1043,9 m/h
2
0
200
400
600
800
1000
1200
1400
1600
1800
[m/h]
Curve according to: ISO 9906
Design point
Flow
1043,5 m/h
Of f erta
Guarantee
Head
21,3 m
Stat. head
0m
ID of f erta
Shaft power
<74,6 kW
NPSHre
3,8 m
Creato da
Hyd eff.
83,5
ISO_9906_Grade_2
Si
Creato il
2013-09-25
Ultimo aggiornamento
CT 3306/665 3~ 631
Duty Analysis
[m]
Altura de impulsin
36,0
35,0
34,0
33,0
32,0
31,0
30,0
29,0
28,0
27,0
26,0
25,0
24,0
23,0
22,0
21,3 m
21,0
20,0
84,1%
19,0
18,0
17,0
16,0
15,0
14,0
13,0
12,0
11,0
10,0
9,0
631 460mm
8,0
7,0
6,0
5,0
4,0
3,0
2,0
1,0
1043,9 m/h
0,0
0
200
400
600
800
1000
1200
1400
1600
1800
[m/h]
Curve according to: ISO 9906
Indiv idual pump
Total
Pumps
running
/System
Flow
Head
Shaft power
Flow
Head
Shaft power
Hyd eff.
Specific
energy
NPSHre
1040 m/h
21,3 m
72,6 kW
1040 m/h
21,3 m
72,6 kW
83,6 %
7,52E-5 kWh/l
3,77 m
Of f erta
ID of f erta
Creato da
Creato il
2013-09-25
Ultimo aggiornamento
CT 3306/665 3~ 631
VFD Curv e
[m] Altura de impulsin
36
35
34
33
32
31
30
29
28
27
26
25
24
23
22
21
20
19
18
17
16
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
0
[%]
Eficiencia
80 Eficiencia total
70
60
50
40
30
20
10
0
[kW]
Potencia en el eje motor P2
80
Potencia absorbida P1
70
60
50
40
30
20
10
0
Valores NPSH
[m]
84,1%
84,1%
84,1%
84,1%
631 460mm
45 Hz
84,1%
40 Hz
35 Hz
30 Hz
30 Hz
35 Hz
40 Hz
45 Hz
631 460mm
631Hz
45
40
35
30
460mm
631 460mm (P1)
631 460mm (P2)
45 Hz
45 Hz
40
40 Hz
Hz
35
35 Hz
Hz
30 Hz
631 460mm
45 Hz
10
40 Hz
8
35 Hz
6
30 Hz
4
2
0
200
400
600
800
1000
1200
1400
1600
1800
[m/h]
Curve according to: ISO 9906
Of f erta
ID of f erta
Creato da
Creato il
2013-09-25
Ultimo aggiornamento
CT 3306/665 3~ 631
VFD Analysis
[m]
Altura de impulsin
36,0
35,0
34,0
33,0
32,0
31,0
30,0
29,0
28,0
27,0
26,0
25,0
24,0
23,0
22,0
21,3 m
21,0
20,0
84,1%
19,0
18,0
17,0
16,0
84,1%
15,0
14,0
13,0
84,1%
12,0
11,0
10,0
84,1%
9,0
631 460mm
8,0
7,0
45 Hz
84,1%
6,0
40 Hz
5,0
35 Hz
4,0
30 Hz
3,0
2,0
1,0
1043,9 m/h
0,0
0
200
400
600
800
1000
1200
1400
1600
1800
[m/h]
Curve according to: ISO 9906
Indiv idual pump
Total
Pumps
running
/System
Frequency
Flow
Head
Shaft power Flow
Head
Shaft power Hyd eff.
Specific
energy
NPSHre
1
1
1
1
1
50 Hz
45 Hz
40 Hz
35 Hz
30 Hz
1040 m/h
936 m/h
832 m/h
728 m/h
624 m/h
21,3 m
17,1 m
13,5 m
10,4 m
7,61 m
72,6 kW
52,3 kW
36,7 kW
24,6 kW
15,5 kW
21,3 m
17,1 m
13,5 m
10,4 m
7,61 m
72,6 kW
52,3 kW
36,7 kW
24,6 kW
15,5 kW
7,52E-5 kWh/l
6,05E-5 kWh/l
4,84E-5 kWh/l
3,81E-5 kWh/l
2,96E-5 kWh/l
3,77 m
3,17 m
2,62 m
2,12 m
1,66 m
Of f erta
ID of f erta
1040 m/h
936 m/h
832 m/h
728 m/h
624 m/h
Creato da
83,6 %
83,6 %
83,6 %
83,6 %
83,6 %
Creato il
2013-09-25
Ultimo aggiornamento
CT 3306/665 3~ 631
Dimensional drawing
28(4X)
70
850
11.25
M20(16X)
460
Y-Y
650
G3/4
30
1890
24(4X)
65
1820
255*
300
Y
1025
805
330
DN
VIEW
X- X
ISO
FOR COOLING JACKET DRAIN
VIEW
NOT DELIVERED BY FLYGT
990
850
THREADED HOLES
X
DN
MIN
TO SUMP
400
650
525
PINS TO ANCHOR PEDESTALS
435 325
NOTE:
PUMP CAN BE ROTATED ABOUT ITS CENTERLINE
TO 4 POSITIONS RELATIVE TO THE INLET ELBOW.
INCREMENTS ARE 90.
* DIMENSION TO INLET ELBOWFLANGE
160
400
Dimensional drwg
CT,NT 3306 665/675
Of f erta
ID of f erta
Creato da
Creato il
2013-09-25
Ultimo aggiornamento