0% found this document useful (0 votes)
322 views1 page

6SL3244 0BB12 1PA1 Datasheet en

The document provides technical specifications for the SINAMICS Control Unit CU240E-2 DP, including: - Electrical data such as an operating voltage of DC 24V, power consumption of 0.50A, and power loss of 5.50W. - Inputs and outputs including 6 standard digital inputs, 1 fail-safe digital input, and 2 digital outputs as relay changeover contacts. - Communication capabilities including PROFIBUS DP and support for closed-loop control techniques like V/f linear control. - Compliance with standards like UL, cUL, CE, and C-Tick and a protection class of IP20.

Uploaded by

JULIAN
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
322 views1 page

6SL3244 0BB12 1PA1 Datasheet en

The document provides technical specifications for the SINAMICS Control Unit CU240E-2 DP, including: - Electrical data such as an operating voltage of DC 24V, power consumption of 0.50A, and power loss of 5.50W. - Inputs and outputs including 6 standard digital inputs, 1 fail-safe digital input, and 2 digital outputs as relay changeover contacts. - Communication capabilities including PROFIBUS DP and support for closed-loop control techniques like V/f linear control. - Compliance with standards like UL, cUL, CE, and C-Tick and a protection class of IP20.

Uploaded by

JULIAN
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 1

Data sheet for SINAMICS Control Unit CU240E-2 DP

MLFB-Ordering data
6SL3244-0BB12-1PA1

Figure similar

Client order no. : Item no. :


Order no. : Consignment no. :
Offer no. : Project :
Remarks :

Electrical data Ambient conditions

Operating voltage via Ambient temperature

The Power Module DC 24 V Operation -10 ... 55 C (14 ... 131 F)

External power supply DC 20 ... 29 V Storage -40 ... 70 C (-40 ... 158 F)

Max. power consumption 0.50 A Relative humidity

Power loss 5.50 W Max. operation 95 %

Inputs / outputs Communication

Standard digital inputs Communication PROFIBUS DP

Number 6 Closed-loop control techniques


Switching level: 01 11 V V/f linear / square-law / parameterizable Yes

Switching level: 10 5V V/f with flux current control (FCC) Yes

Fail-safe digital inputs V/f ECO linear / square-law Yes

Number 1 (Use of 2 DI Standard) Sensorless vector control Yes

Vector control, with sensor No


Digital outputs
Encoderless torque control Yes
Number as relay changeover contact 2
Torque control, with encoder No

Standards

Compliance with standards UL, cUL, CE, C-Tick (RCM)

CE marking Low-voltage directive 2006/95/EC


Analog / digital inputs

Number 2 (Differential input) Mechanical data


Analog outputs Degree of protection IP20

Net weight 0.49 kg


Number 2 (Non-isolated output)
Width 73.0 mm
Connections
Height 199.0 mm
Signal cable
Depth 46.0 mm
Conductor cross-section 0.05 ... 1.50 mm (30 ... 16 AWG)