SmartPTT Basic Configuration Guide
SmartPTT Basic Configuration Guide
SmartPTT Basic
Installation & Configuration Guide
December 2016
Table of Contents
Table of Contents
1.1 Introduction 2
1.2 Installation of the SmartPTT software 2
1.3 General SmartPTT Radioserver Configuration 6
1.4 SmartPTT Dispatcher Configuration 10
1.5 Control Stations 15
1.5.1 MOTOTRBO Equipment Programming 16
MOTOTRBO Control Station Programming 18
MOTOTRBO Repeater Programming 23
MOTOTRBO Radio Programming 25
1.5.2 SmartPTT Radioserver Configuration 28
The system configuration depends on the network used and the devices available. In this document, you will learn
how to install and configure the system on the basis of MOTOTRBO control station.
Adding the programs and applications which were omitted during the previous installation.
Note. If you wish to upgrade the SmartPTT software by means of the product or version, you should uninstall the
You have Microsoft .NET Framework installed (not earlier than 4.6):
o NO: you should agree to install Microsoft .NET Framework when InstallShield Wizard will ask you.
YES: select This feature will not be available for Microsoft SQL Express during the installation
NO: you should upgrade to at least Microsoft SQL Server 2008 before the installation of the
SmartPTT software and select This feature will not be available during the installation of the
SmartPTT software.
o NO: you should select This feature will be installed on local hard drive during the installation of the
SmartPTT software.
1. Run autorun.exe file from the folder where you copied SmartPTT installation package.
2. Choose between SmartPTT Radioserver and SmartPTT Dispatcher to install on the current PC. If you install
both of them on the same PC, we would recommend you to start with Radioserver.
3. Follow the instructions of InstallShield Wizard. You should perform the following additional actions during the
installation:
a. Install Microsoft .NET Framework if InstallShield Wizard asks you. It is needed for the work of the
SmartPTT software.
b. Restart the PC after Microsoft .NET Framework installation if InstallShield Wizard asks you.
Note. In rare cases InstallShield Wizard will not ask you to restart the PC. However, the problem may occur in the
work of the freshly installed SmartPTT software. If you notice them, please, start the installation and select
if you have Microsoft SQL Server not earlier than 2008 version, in the Custom Setup window click the
Microsoft SQL Express icon and select This feature will not be available.
if you have Microsoft SQL Server earlier than 2008 version, in the Custom Setup window click the
Microsoft SQL Express icon and select This feature will not be available. Then you should upgrade
if you do not have Microsoft SQL Server, you should select in the Custom Setup window. For this in the
Custom Setup window click the Microsoft SQL Express icon and select This feature will be installed
on local hard drive or This feature, and all subfeatures, will be installed on local hard drive.
In the Name field specify the radioserver name. This name is used only in SmartPTT Radioserver
Configurator;
In the Interface field and the Port field specify the IP address and port of the PC where the radioserver is
installed.
2. Enable radio network services, e.g., ARS, GPS and TMS support.
To enable ARS support, select the Active check box under ARS:
To enable GPS support, select the Active check box under GPS:
To enable text messaging service, select the Active check box under TMS:
The general configuration of the SmartPTT Dispatcher console includes the following steps:
1. License installation
2. Database creation
3. Radioserver configuration
1. Expand the Settings menu in the Main Menu bar of the SmartPTT Dispatcher window and click Licenses.
Install the required license. After uploading the license, click Finish to apply.
2. Expand the Settings menu in the Main Menu bar of the SmartPTT Dispatcher window and click Database.
In the opened window create the new database and then connect to it.
To create a new database, fill in the Database Server Name and click Create New Database. For a database
server installed together with the SmartPTT dispatcher application enter the name using the format: Name of PC
In the window that opened enter the name of the new database and click Save.
If creation was successful, a message about successful database creation is displayed. If the database is not
Authorization Mode allows you to select authorization mode with the database.
SQL Server Authorization you must have the login and password of the account which has access to the
SQL server.
Windows NT Authorization the user who has logged into the Windows system, must be listed in the SQL
After you have finished, click Finish to save the changes. You will need to restart SmartPTT Dispatcher to apply
the changes.
3. In the Settings menu click Radioservers to add the radioserver and configure it properly.
Click Add to open the window for adding radioservers to the list.
Enter the name of the radioserver in the Name field. The name will be displayed in the SmartPTT Dispatcher
console.
In the Address and Port fields enter the radioserver IP address and port number to connect with the dispatcher.
To find out the radioserver IP run the ipconfig command on the PC where the radioserver is installed. The
For more information about the radioserver settings see Help in the SmartPTT Dispatcher application.
4. Audio setting configuration is required to give the operator the ability to communicate with the radio
subscribers. Expand the Settings menu in the Main Menu bar of the SmartPTT Dispatcher window and
click Sound.
5. Register radio subscribers. Unregistered radio subscribers are displayed in italics in the Radio Fleet window
To register the radio subscriber, right-click on the radio subscriber, enter the name and click Save.
There are many ways how to configure the system. It depends on the devices available and the network used:
Direct data transmission between a control station and radios without the use of a repeater.
Data transmission between a control station and radios with the use of a repeater.
In case of data transmission with the use of a repeater the system setup includes an additional step
To program MOTOTRBO equipment, you need MOTOTRBO Customer Programming Software (CPS).
1. Connect your device to the PC via a programming cable and launch MOTOTRBO CPS.
2. Switch on the device and check its settings by clicking the Read button on the menu bar.
3. In the View menu select Expert to gain access to all the settings parameters.
4. In the Device Information tab make sure that firmware version is no older than:
Note: It is recommended to use the same firmware version for all MOTOTRBO equipment on the same network.
5. Click Write (next to the Read button on the menu bar) to apply the changes in the settings.
1. In the General Settings tab set the Radio ID. This ID number must be unique for each control station in the
communication system. Make sure that GPS is disabled. Enable Private Calls to allow a radio subscriber
2. In the Accessories tab specify Rear PC & Audio value in the Cable Type field.
4. In the Contacts tab right-click the Digital item and add the All Call contact.
This contact will be used by the dispatcher to call all subscribers covered by the network. A user can change
the All Call alias. The All Call ID value is 16777215 by default and can not be changed.
Add to the contact list subscriber groups, which are planned to be created in the system and must be
5. In the RX Group Lists tab switch to an Available list. Add created groups from the Available section to
To do that, add Digital Channel and configure it in the following way. Set required RX and TX frequencies for
this channel. Assign a list of groups (created in step 9) in the Group List field.
This section may be omitted if the configured system is not supposed a repeater usage.
1. In the General Settings tab set Radio ID = 125. The Radio ID must be unique.
3. In the Channels tab add Digital Channel. Set Color Code = 1, IP Site Connect = None. Please
remember to check that the Color Code in the repeater settings is equal to the Color Code settings in the
radio and control station settings. Set required RX and TX frequencies for the channel. Repeater RX
frequency must match control station TX frequency. Repeater TX frequency must match control station RX
frequency.
1. In the General Settings tab set the Radio ID. This ID number must be unique for each radio in the
communication system. Enable GPS to track the subscriber location, if the radio supports this functionality.
Enable Private Calls to allow a radio subscriber to receive and respond to private calls.
2. In the Network tab specify ARS Radio ID and TMS Radio ID in accordance with the control station Radio
ID.
3. In the Contacts tab right-click the Digital item. Add Group Call for each group which was created in the
corresponding section of control station settings. Set appropriate group ID in the Call ID field.
4. In the RX Group Lists tab switch to an available list. Add created groups from the Available section to the
Members list.
5. In the Channels tab create necessary number of channels. For that add Digital channel and configure it in
the following way. Enable ARS and set required RX and TX frequencies for this channel. Configuring the
system without a repeater, RX and TX frequencies must be equal to each other and to the corresponding
frequencies of the control station. Setting up the system with a repeater, RX and TX frequencies must be
Assign a list of groups (created in step 8) in the Group List field. Set Contact Name to one of previously
To make the system work, you need to configure the radioserver settings using SmartPTT Radioserver
Configurator.
1. Run SmartPTT Radioserver Configurator, which you have already downloaded and installed, as described in
2. In the setting tree on the left right-click on the Licenses section. In the opened window click the Change
License button the browse window is displayed. Specify the location of the license file and click Open.
The license is installed and the window displays information on the license type.
3. In the setting tree on the left right-click on Control Stations, click Add and then click Control Station
MOTOTRBO.
Control station is a base radio connected to the radioserver PC by means of USB + Audio cable.
IP local IP address of the control station. The following address format and range are used: (001-223).(000-
255).(000-255).(001-253). Users can use any address except 127.x.x.x in the range from 1.x.x.x to
223.x.x.x. We recommend to use the address 192.168.10.1 by default, and in case of conflicts with other
Note: If two or more control stations are connected to the computer, one of the first three octets of the IP address
Radio ID unique control station identifier used during communication with it. ID is to be set in the range from 1
Note: IP and ID settings must correspond to Radio IP and Radio ID programmed for the control station in CPS.
Select Active to activate the radioserver work with the control station.
4. After adding a control station, configure its channels. To set up and edit control station channels, click
Channels in the settings tree of SmartPTTSmartPTT Radioserver Configurator. To add a channel click the
Add button. At that, a record of the added channel appear in the table. Add all channels which were set up
You can change the alias of any channel for your convenience. Assign for each channel assign appropriate
5. To set up and edit control station talkgroups, click Talkgroups in the settings tree of SmartPTT Radioserver
Configurator. To add a group, click the Add button. Add all contacts that were added for the control station in
CPS settings.
6. To select audio devices and set up VoIP parameters, click Audio in the settings tree of SmartPTT
Radioserver Configurator.
The Active check box allows disabling calls for a control station if it is used to transmit data only.
Audio Input an audio device to which the control station audio output is connected.
Input Line audio mixer line used for connections. The control station audio output can be connected to the
Audio Output an audio device to which the control station audio input is connected.
7. Click the Save button to save configuration and restart service by clicking the Restart button.