ULTIMA
JOB NO & ADDRESS RF0871
PILE GROUP NAME ALL PILES
ULTIMATE LOAD N* 540
DIA OF PILE 0.45
NOS OF PILES IN GROUP 1
STRATA SOCKET DEPTH
DW SILTSTONE 7.50
7.50
GEOTECHNICAL STRENGTH _
REDUCTION FACTOR(AS2159-2009)
_(,)
CAPACITY PER PILE
CAPACITY OF PILE GROUP
ALL LOADS ARE IN KN, AND DIMENTION ARE IN METERS
WOR
JOB NO & ADDRESS RF0871
PILE GROUP NAME ALL PILES
WORKING LOAD N 400
DIA OF PILE 0.45
NOS OF PILES IN GROUP 1
STRATA SOCKET DEPTH
DW SILTSTONE 7.50
0 0.00
7.50
GEOTECHNICAL STRENGTH _
REDUCTION FACTOR(AS2159-2009)
_(,)
_(,)
CAPACITY PER PILE
CAPACITY OF PILE GROUP
ALL LOADS ARE IN KN, AND DIMENTION ARE IN METERS
ULTIMATE LIMIT STATE CAPACITY CHECK
219 NAPIER STREET, FITZROY
ULTIMATE SKIN FRICTION(KPa)
100
TOTAL
ULTIMATE END BEARING(KPa)
1500
0.6
_ _(,)
WORKING STRESS CAPACITY CHECK
219 NAPIER STREET, FITZROY
ALLOWABLE SKIN FRICTION(KPa)
50
0
TOTAL
ALLOWABLE END BEARING(KPa)
750
1
_
_ _(,)
_(,)
T STATE CAPACITY CHECK
19 NAPIER STREET, FITZROY
ULTIMATE SKIN FRICTION CAPACITY
0
1060
0
0
1060
ULTIMATE END BEARING CAPACITY
239
779
779
RESS CAPACITY CHECK
19 NAPIER STREET, FITZROY
SKIN FRICTION CAPACITY
530
0
530
ALLOWABLE END BEARING CAPACITY
119
649
649
DESIGN WORKING LOAD
SWL 0
G (WORKING DEAD LOAD) 300
Q (WORKING LIVE LOAD) 100
W (WIND ULTIMATE) 0
P (EQ ULTIMATE)
LOAD COMBINATION
1.35*SWL 540
G+Q 400
1.2*G+1.5*Q 510
1.2*G+0.4*Q+W 400
1.2*G+0.4*Q-W 400
0.9*G+W 270
0.9*G-W 270
G+0.4*Q+EQ 340
G+0.4*Q-EQ 340
MAXIMUM ECC 0.075
MAXIMUM ECC MOMENT 40.5
DESIGN WORKING LOAD
SWL 0
G (WORKING DEAD LOAD) 300
Q (WORKING LIVE LOAD) 100
FOS 2
LOAD COMBINATION
SWL 400
G+Q 400
MAXIMUM ECC 0.075
MAXIMUM ECC MOMENT 30.0
250
50
750
U
JOB NO & ADDRESS RF0
PILE GROUP NAME
ULTIMATE LOAD N* 4050
DIA OF PILE 0.75
NOS OF PILES IN GROUP 1
STRATA SOCKET DEPTH
Siltstone SW 9.0
GEOTECHNICAL STRENGTH _
REDUCTION FACTOR(AS2159-2009)
CAPACITY PER PILE _(,)
CAPACITY OF PILE GROUP
ALL LOADS ARE IN KN, AND DIMENTION ARE IN METERS
JOB NO & ADDRESS RF0
PILE GROUP NAME 0
WORKING LOAD N 3000
DIA OF PILE 0.75
NOS OF PILES IN GROUP 1
STRATA SOCKET DEPTH
Siltstone SW 9.0
0 0.0
GEOTECHNICAL STRENGTH _
REDUCTION FACTOR(AS2159-2009)
_(,)
CAPACITY PER PILE
CAPACITY OF PILE GROUP
ALL LOADS ARE IN KN, AND DIMENTION ARE IN METERS
JOB NO & ADDRESS RF0
PILE GROUP NAME 0
ULTIMATE LOAD T* 5250
DIA OF PILE 0.75
NOS OF PILES IN GROUP 1
STRATA SOCKET DEPTH
Siltstone SW 9.0
0 0.0
GEOTECHNICAL STRENGTH _
REDUCTION FACTOR(AS2159-2009)
CYCLIC _
REDUCTION FACTOR
_(,)
CAPACITY PER PILE
CAPACITY OF PILE GROUP
ALL LOADS ARE IN KN, AND DIMENTION ARE IN METERS
ULTIMATE LIMIT STATE CAPACITY CHECK
ULTIMATE SKIN FRICTION(KPa)
1000
TOTAL
ULTIMATE END BEARING(KPa)
15000
0.65
_ _(,)
WORKING STRESS CAPACITY CHECK
0
ALLOWABLE SKIN FRICTION(KPa)
500
0
TOTAL
ALLOWABLE END BEARING(KPa)
7500
1
_ _(,)
TENSILE LIMIT STATE CAPACITY CHECK
ULTIMATE SKIN FRICTION(KPa)
1000
0
TOTAL
0.65
0.80
_ _(,)
MIT STATE CAPACITY CHECK
ULTIMATE SKIN FRICTION CAPACITY
0
21206
0
0
21206
ULTIMATE END BEARING CAPACITY
6627
18091
18091
STRESS CAPACITY CHECK
0
SKIN FRICTION CAPACITY
10603
0
10603
ALLOWABLE END BEARING CAPACITY
3313
13916
13916
MIT STATE CAPACITY CHECK
ULTIMATE SKIN FRICTION CAPACITY
0
21206
0
0
21206
11027
11027
DESIGN WORKING LOAD
SWL 3000
G (WORKING DEAD LOAD) 0
Q (WORKING LIVE LOAD) 0
W (WIND ULTIMATE) 0
P (EQ ULTIMATE) 0
LOAD COMBINATION
1.35*SWL 4050
G+Q 3000
1.2*G+1.5*Q 0
1.2*G+0.4*Q+W 0
1.2*G+0.4*Q-W 0
0.9*G+W 0
0.9*G-W 0
G+0.4*Q+EQ 0
G+0.4*Q-EQ 0
MAXIMUM ECC 0.075
MAXIMUM ECC MOMENT 303.8
DESIGN WORKING LOAD
SWL 3000
G (WORKING DEAD LOAD) 0
Q (WORKING LIVE LOAD) 0
FOS 2
LOAD COMBINATION
SWL 3000
G+Q 0
MAXIMUM ECC 0.075
MAXIMUM ECC MOMENT 225.0
DESIGN WORKING LOAD
T (SWL) 3500
LOAD COMBINATION
1.50 * T 5250
MAXIMUM ECC 0.075
MAXIMUM ECC MOMENT 506.3
ULTIMA
JOB NO & ADDRESS RF0871
PILE GROUP NAME ALL PILES
ULTIMATE LOAD N* 1424
DIA OF PILE 0.6
NOS OF PILES IN GROUP 1
STRATA SOCKET DEPTH
DW SILTSTONE 3.00
3.00
GEOTECHNICAL STRENGTH _
REDUCTION FACTOR(AS2159-2009)
_(,)
CAPACITY PER PILE
CAPACITY OF PILE GROUP
ALL LOADS ARE IN KN, AND DIMENTION ARE IN METERS
WOR
JOB NO & ADDRESS RF0871
PILE GROUP NAME ALL PILES
WORKING LOAD N 1055
DIA OF PILE 0.6
NOS OF PILES IN GROUP 1
STRATA SOCKET DEPTH
DW SILTSTONE 3.00
0 0.00
3.00
GEOTECHNICAL STRENGTH _
REDUCTION FACTOR(AS2159-2009)
_(,)
_(,)
CAPACITY PER PILE
CAPACITY OF PILE GROUP
ALL LOADS ARE IN KN, AND DIMENTION ARE IN METERS
ULTIMATE LIMIT STATE CAPACITY CHECK
219 NAPIER STREET, FITZROY
ULTIMATE SKIN FRICTION(KPa)
300
TOTAL
ULTIMATE END BEARING(KPa)
5000
0.6
_ _(,)
WORKING STRESS CAPACITY CHECK
219 NAPIER STREET, FITZROY
ALLOWABLE SKIN FRICTION(KPa)
150
0
TOTAL
ALLOWABLE END BEARING(KPa)
2500
1
_
_ _(,)
_(,)
T STATE CAPACITY CHECK
19 NAPIER STREET, FITZROY
ULTIMATE SKIN FRICTION CAPACITY
0
1696
0
0
1696
ULTIMATE END BEARING CAPACITY
1414
1866
1866
RESS CAPACITY CHECK
19 NAPIER STREET, FITZROY
SKIN FRICTION CAPACITY
848
0
848
ALLOWABLE END BEARING CAPACITY
707
1555
1555
DESIGN WORKING LOAD
SWL 1055
G (WORKING DEAD LOAD) 0
Q (WORKING LIVE LOAD) 0
W (WIND ULTIMATE) 0
P (EQ ULTIMATE) 0
LOAD COMBINATION
1.35*SWL 1424.25
G+Q 1055
1.2*G+1.5*Q 0
1.2*G+0.4*Q+W 0
1.2*G+0.4*Q-W 0
0.9*G+W 0
0.9*G-W 0
G+0.4*Q+EQ 0
G+0.4*Q-EQ 0
MAXIMUM ECC 0.075
MAXIMUM ECC MOMENT 106.8
DESIGN WORKING LOAD
SWL 1055
G (WORKING DEAD LOAD) 0
Q (WORKING LIVE LOAD) 0
FOS 2
LOAD COMBINATION
SWL 1055
G+Q 0
MAXIMUM ECC 0.075
MAXIMUM ECC MOMENT 79.1
ULTIMA
JOB NO & ADDRESS LA715
PILE GROUP NAME BP1
ULTIMATE LOAD N* 1654
DIA OF PILE 0.9
NOS OF PILES IN GROUP 1
STRATA SOCKET DEPTH
0.5
MD SAND 6.50
5.00
12.00
GEOTECHNICAL STRENGTH _
REDUCTION FACTOR(AS2159-2009)
_(,)
CAPACITY PER PILE
CAPACITY OF PILE GROUP
ALL LOADS ARE IN KN, AND DIMENTION ARE IN METERS
WOR
JOB NO & ADDRESS LA715
PILE GROUP NAME BP1
WORKING LOAD N 4900
DIA OF PILE 0.9
NOS OF PILES IN GROUP 1
STRATA SOCKET DEPTH
MD SAND 6.50
0 5.00
11.50
GEOTECHNICAL STRENGTH _
REDUCTION FACTOR(AS2159-2009)
_(,)
_(,)
CAPACITY PER PILE
CAPACITY OF PILE GROUP
ALL LOADS ARE IN KN, AND DIMENTION ARE IN METERS
ULTIMATE LIMIT STATE CAPACITY CHECK
219 NAPIER STREET, FITZROY
ULTIMATE SKIN FRICTION(KPa)
50
50
TOTAL
ULTIMATE END BEARING(KPa)
2000
0.6
_ _(,)
WORKING STRESS CAPACITY CHECK
219 NAPIER STREET, FITZROY
ALLOWABLE SKIN FRICTION(KPa)
25
25
TOTAL
ALLOWABLE END BEARING(KPa)
1000
1
_
_ _(,)
_(,)
T STATE CAPACITY CHECK
19 NAPIER STREET, FITZROY
ULTIMATE SKIN FRICTION CAPACITY
0
919
707
0
1626
ULTIMATE END BEARING CAPACITY
1272
1739
1739
RESS CAPACITY CHECK
19 NAPIER STREET, FITZROY
SKIN FRICTION CAPACITY
459
353
813
ALLOWABLE END BEARING CAPACITY
636
1449
1449
DESIGN WORKING LOAD
SWL
G (WORKING DEAD LOAD) 3513
Q (WORKING LIVE LOAD) 1387
W (WIND ULTIMATE) 83
P (EQ ULTIMATE) 610.2
LOAD COMBINATION
1.35*SWL 6615
G+Q 4900
1.2*G+1.5*Q 6296
1.2*G+0.4*Q+W 4853
1.2*G+0.4*Q-W 4687
0.9*G+W 3245
0.9*G-W 3079
G+0.4*Q+EQ 4678
G+0.4*Q-EQ 3458
MAXIMUM ECC 0.075
MAXIMUM ECC MOMENT 496.1
DESIGN WORKING LOAD
SWL 0
G (WORKING DEAD LOAD) 3513
Q (WORKING LIVE LOAD) 1387
FOS 2
LOAD COMBINATION
SWL 4900
G+Q 4900
MAXIMUM ECC 0.075
MAXIMUM ECC MOMENT 367.5
AXIAL LOADS
ULT AXIAL LOAD
DEAD LIVE SDL EQ
LD1 380 75 55 225 726 690
LD2 144 25 20 95 270 269
LD3 720 140 75 385 1338 1236
LD4 1142 200 100 310 2073 1632
LD5 225 60 30 165 445.5 444
LD6 365 100 50 145 727.5 600
LD7 460 110 70 250 906 824
SHEAR LOADS
DEAD LIVE SDL EQ ULT SHEAR LOAD
LD1 45 15 10 85 97.5 146
LD2 19 5 5 85 40.5 111
LD3 166 35 20 290 315 490
LD4 155 30 20 65 292.5 252
LD5 125 35 20 130 253.5 289
LD6 45 10 5 165 85.5 219
LD7 45 10 10 50 91.5 109
MOMENT
ULT
DEAD LIVE SDL EQ MOMNET
LD1 75 20 10 296 148.5 389
LD2 35 10 5 219.5 70.5 264
LD3 210 45 30 415 405 673
LD4 615 150 75 722.5 1192.5 1473
LD5 208 60 35 272 426 539
LD6 80 20 10 402.5 156 501
LD7 80 20 10 200 156 298
SHEAR CORE
BP1
Axial load 6615
Moment
Length of
the panel
726 3.50 207 368
270 3.10 87 207
1338 3.50 382 500
2073 3.00 691
446 3.70 120 301.0135
728 4.00 182 218.25
906 3.80 238 286.1053
Length of
the panel
146 3.50 42 74
111 3.10 36 85
490 3.50 140 183
293 3.00 98
289 3.70 78 175.7432
219 4.00 55 65.7
109 3.80 29 64.53947
Length of
the panel Ecc moment/m
389 3.50 111 67 313 2.59 0.74
264 3.10 85 28 199 2.294 0.74
673 3.50 192 86 269 2.59 0.74
1473 2.60 566 225 791 1.924 0.74
539 3.70 146 39 416 2.738 0.74
501 4.00 125 59 183 2.96 0.74
298 3.80 78 77 390 2.812 0.74
Length of the panel Ecc moment/m
3.5 111 67 423
3.1 85 28 269
3.5 192 86 364
2.6 566 225 791
3.7 146 39 416
4 125 59
3.8 78 77 390
WALLAP
MOMENT
including Shear Excavatio Anchor
Ecc load n Pile depth Diameter spacing
RW1 35.1 53.1 3.5 7.5 450 0.9
RW2 369.6 195.6 3.5 7.5 600 0.2
RW2 A 393.6 262.8 5.5 10 600 1.2
RW3 393.6 262.8 5.5 10 600 1.2
RW4 76 45 2.5 6 450 0
RW5 68.4 43.2 2.5 6 600 0
Grid 2 BP1A 850 320 0 8 750
Grid D BP1B 850 308 0 8 750
GRID 1 BP1C (LD1) 464 177 8 600
GRID 1 BP1D (LD2) 322 125 0 8 600
GRID 1 BP1E (LD3) 520 197 8 600
CORE PILE BP1F 12 900
Pile No of
spacing piles
0.9 10 10 8N20 N12-300
1.2 12 6 8N32 N12-300
1.2 5 5 8N32 N12-300
0.6 3 1 8N32 N12-300
0.9 9 0 8N20 N12-300
0.9 7 0 8N20 N12-300
No of piles
11 12N32 N12-300
10 12N32 N12-300
6 8N36 N12-300
4 8N28 N12-300
13 8N36 N12-300
9 12N36
0.104267