MENCK MHU HYDRAULIC HAMMER DATA SHEET- Rev. I (15/05/2007)
Standard Anvil suitable for piles up to in 2062 2062 3660 36-72 60-86 48-86 3660
Max. Batter Pile Deg NA NA NA NA NA
Legend: NA= Not Available; GRLWeap = Driveability Software-Name; Ass.= Assumed; C.o.G.= Centre of Gravity.
3 of 13
MENCK MRBS STEAM HAMMER DATA SHEET- Rev. I (15/05/2007)
4 of 13
MENCK MRBS STEAM HAMMER DATA SHEET- Rev. I (15/05/2007)
5 of 13
DELMAG D DIESEL HAMMER DATA SHEET- Rev. I (15/05/2007)
6 of 13
DELMAG D DIESEL HAMMER DATA SHEET- Rev. I (15/05/2007)
DELMAG DELMAG
HAMMER TYPE: DIESEL (Only Above Water)
D150-42 D200-42
OPERATING DATA Unit
Max. Rated Energy (Setting 1) kNm 512.10 (100%) 682.80 (100%)
Partial Rated Energy (Setting 2) kNm 459.35 (~89.7%) 612.47 (~89.7%)
Partial Rated Energy (Setting 3) kNm 376.91 (~73.6%) 502.54 (~73.6%)
Min. Rated Energy (Setting 4) kNm 328.26 (~64.1%) 437.68 (~64.1%)
Blow Rate at max. Energy bl/min 36 36
Weight of Ram (Impact Weight-Piston) kN 150 200
Maximum Stroke m 3.414 3.414
Hammer Efficiency (Continuous mode) % 80 80
Hammer Efficiency (At Restart or Full Set-up) % 70 70
Company Number Az. To Rent
WEIGHT DATA
Helmet (Depend on pile OD) (GRLWeap database) kN 4.4 218.27
Offshore Guide Cage kN 16.7 519.93
Weight in Air kN 45.7 109.5
C.o.G. measured from top of Pile m 5.4 2.6
DIMENSIONAL DATA
Guide Cage Length (From Anvil up to Bottom) m 2 up to 5 1 up to 5
Min. Guide Cage overall dimension m 2 ~2.8
Hammer length incl. pile Guide Cage m 11.03 up to 14.03 12.700 up to 16.700
CUSHION DATA
Type - Aluminium / HGW
Elastic Modulus MPa 9417 9417
Area cm 3370 7238
Thickness mm 105 105
Restitution Coefficient - 0.8 0.80
HAMMER DATA vs. PILE
Pile sleeve suitable for piles O.D. up to in 60 84
Standard Anvil suitable for piles up to in 36/40/42/48/60 48/54/60/72/84
Max. Pile True Batter Deg 18.3 18.3
Legend: NA= Not Available; GRLWeap = Driveability Software-Name; Ass.= Assumed; C.o.G.= Centre of Gravity.
8 of 13
Pile vs. Hydraulic Hammer (Menck MHU)
Menck Suitable Pile Diameter [inch] vs. Menck Anvil (Inner dome)
Hammer 18 20 30 32 36 38 40 42 44 46 48 50 52 56 58 60 62 72 84 102
MHU 195 OK OK OK OK OK OK OK OK Anvil Inner Dome Diameter 345mm, Max. Allowable Wall Thickness for 18 Pile is 2.25 in.
MHU 220 OK OK OK OK OK OK OK OK Anvil Inner Dome Diameter 345mm, Max. Allowable Wall Thickness for 18 Pile is 2.25 in.
Anvil Inner Dome Diam. 750mm, Max.
MHU 600T All. Wall Thick. for 36 Pile is 3.25 in. OK OK OK OK OK OK OK OK OK OK OK OK - - - -
MHU 800S Anvil Inner Dome Diam. 1038mm, Max. Allowable Wall Thickness for 48 Pile is 3.5 in. OK OK OK OK OK OK OK OK OK -
Anvil Inner Dome Diam. 1066mm, Max. Allowable Wall Thickness for 48 Pile is 3 in. OK OK OK OK OK OK OK OK OK -
MHU 1000
Anvil Inner Dome Diameter 1300mm, Max. Allowable Wall Thickness for 56 Pile is 2.375 in. OK OK OK OK OK OK OK
MHU 1700 Anvil Inner Dome Diam. 1046mm, Max. Allowable Wall Thickness for 48 Pile is 3.375 in. OK OK OK OK OK OK OK OK OK OK
MHU 3000 Anvil Inner Dome Diameter 1360mm, Max. Allowable Wall Thickness for 60 Pile is 3.325 in. OK OK OK OK OK
MHU 270T - OK OK OK OK OK OK OK OK OK OK OK OK OK OK OK OK Inner Dome Diam. 420m
MHU 400T Anvil Inner Dome Diam. 812mm OK OK OK OK OK OK OK OK OK OK OK OK - - - -
MHU 500T Anvil Inner Dome Diam. 812mm OK OK OK OK OK OK OK OK OK OK OK OK OK OK Up to 86 Pile OD
Legend: OK= Suitable
9 of 13
Pile vs. Diesel Hammer (Delmag D)
Delmag Suitable Pile Diameter [inch] vs. Delmag Anvil
Hammer 20 30 32 36 38 40 42 44 46 48 50 52 54 58 60 72 84
D46-32 OK OK OK OK - - - - - - - - - - - - -
D55 OK OK OK OK OK OK OK OK OK OK OK OK OK OK OK - -
D62-12/22 OK OK OK OK OK OK OK OK OK OK OK - - - - - -
OK OK OK OK OK OK OK OK OK OK (Sleeve 2048)
D80-12
(Sleeve 4884) OK OK OK OK OK OK OK OK
OK OK OK OK OK OK OK OK OK OK (Sleeve 2048)
D80-23
(Sleeve 4884) OK OK OK OK OK OK OK OK
OK OK OK OK OK OK OK OK OK OK (Sleeve 2048)
D100-13
(Sleeve 4884) OK OK OK OK OK OK OK OK
D200-42 NA NA NA NA NA NA NA NA NA OK NA NA OK NA OK OK OK
Legend: NA = Not Available; OK= Suitable.
10 of 13
Pile vs. Steam Hammer Anvil (Menck MRBS)
Menck Suitable Pile Diameter vs. Max. Allowable Pile Wall Thickness [inch x inch]
Hammer 20 30 32 36 40 42 44 46 48 50 52 54 58 60 72 84
MRBS 1800 - 1 1.625 - 2.625 3.625 - 1.75 1 2 3 4 - - - -
MRBS 2500/S - 1.875 2.875 1.875 1.5 2.5 - 5 2.5 1 2 2 - - - -
- 1.25 2.25 1 1.375 - 1.625 - 1.75 - Sleeve 3048
MRBS 3000 Sleeve
- 1.75 2.75 1.75 1.25 2.25 3.25 1 2 3 - 1.9 - 1.625 2.5
3062
- Sleeve 4272 2.875 3.875 - 1.875 - 1.875 2.8 1.875 2.875 5 -
MRBS 4600
- Sleeve 4284 1.125 2.125 3.125 4 - 1.625 2.625 1.75 2.875 2.875 2. 875
- - - - - 1.75 - 1.375 2.375 - 1.75 2.75 4.75 5 2.375 3. 25
MRBS 5000/S
- - - - - 3 4 5 5 - 5 5 1.625 2.625 2.375 2.875
MRBS 8000 - - - - - 2.5 1.75 1 2 - 1.75 2.75 1.75 2.625 5 3. 125
11 of 13
Typical O.D. Pile vs. Typical Heavy Plate (Pile) Wall Thickness
O.D. Pile Min. WT W.T. [mm]
18 - 25.4 30 35 38.1 40 45 50 50.8 55 60 63.5 65 70 75 80 90 100 110
20 - 25.4 30 35 38.1 40 45 50 50.8 55 60 63.5 65 70 75 80 90 100 110
24 13 25.4 30 35 38.1 40 45 50 50.8 55 60 63.5 65 70 75 80 90 100 110
28 - 25.4 30 35 38.1 40 45 50 50.8 55 60 63.5 65 70 75 80 90 100 110
30 14 25.4 30 35 38.1 40 45 50 50.8 55 60 63.5 65 70 75 80 90 100 110
32 14 25.4 30 35 38.1 40 45 50 50.8 55 60 63.5 65 70 75 80 90 100 110
36 16 25.4 30 35 38.1 40 45 50 50.8 55 60 63.5 65 70 75 80 90 100 110
38 - 25.4 30 35 38.1 40 45 50 50.8 55 60 63.5 65 70 75 80 90 100 110
40 - 25.4 30 35 38.1 40 45 50 50.8 55 60 63.5 65 70 75 80 90 100 110
42 17 25.4 30 35 38.1 40 45 50 50.8 55 60 63.5 65 70 75 80 90 100 110
44 - 25.4 30 35 38.1 40 45 50 50.8 55 60 63.5 65 70 75 80 90 100 110
46 - 25.4 30 35 38.1 40 45 50 50.8 55 60 63.5 65 70 75 80 90 100 110
48 19 25.4 30 35 38.1 40 45 50 50.8 55 60 63.5 65 70 75 80 90 100 110
50 - 25.4 30 35 38.1 40 45 50 50.8 55 60 63.5 65 70 75 80 90 100 110
52 - 25.4 30 35 38.1 40 45 50 50.8 55 60 63.5 65 70 75 80 90 100 110
54 - 25.4 30 35 38.1 40 45 50 50.8 55 60 63.5 65 70 75 80 90 100 110
56 - 25.4 30 35 38.1 40 45 50 50.8 55 60 63.5 65 70 75 80 90 100 110
60 22 25.4 30 35 38.1 40 45 50 50.8 55 60 63.5 65 70 75 80 90 100 110
72 25 25.4 30 35 38.1 40 45 50 50.8 55 60 63.5 65 70 75 80 90 100 110
84 28 - 30 35 38.1 40 45 50 50.8 55 60 63.5 65 70 75 80 90 100 110
96 31 - - 35 38.1 40 45 50 50.8 55 60 63.5 65 70 75 80 90 100 110
102 - - - 35 38.1 40 45 50 50.8 55 60 63.5 65 70 75 80 90 100 110
108 34 - - 35 38.1 40 45 50 50.8 55 60 63.5 65 70 75 80 90 100 110
120 37 - - 35 38.1 40 45 50 50.8 55 60 63.5 65 70 75 80 90 100 110
Note: Typical Plate Length 3m (10ft); Typical Plate width up to 2.7m. Plate-Pile Typical Fabrication: welded (SAW). Typical Steel Grade: X52
(355MPa), A36 (235MPa) & A40 (275MPa).
12 of 13
Typical Plate-Pile Wall Thickness (AISC)
W.T. [in (mm)]
1 (25.4) 1.125 (28.575) 1.25 (31.75) 1.375 (34.925) 1.5 (38.1) 1.625 (41.275) 1.75 (44.45) 1.875 (47.625)
2 (50.8) 2.125 (53.125) 2.25 (57.15) 2.375 (60.325) 2.5 (63.5) 2.625 (66.675) 2.75 (69.85) 2.875 (73.025)
3 (76.2) 3.125 (79.375) 3.25 (82.55) 3.375 (85.725) 3.5 (88.9) 3.625 (92.075) 3.75 (95.25) 3.875 (98.425)
4 (101.6) 4.25 (107.95) 4.5 (114.3) 4.75 (120.65) Over 5 - - -
Note: Typical Plate Length 3m (10ft); Typical Plate width up to 2.7m. Plate-Pile Typical Fabrication: welded (SAW). Typical Steel Grade: X52
(355MPa), A36 (235MPa) & A40 (275MPa).
Max.
Min. 4.76 5.19 5.71 7.13 6.71 8.13 9.46 9.93 10.30* 11.31 12.52 18.43
18120 14.04
1* (1:12) (1:11.5) (1:10) (1:8) (1:8.5) (1:7) (1:6) (1.4:8) (1:5.5) (1:5) (1:4.5) (1:3)
(1:4)
Note * :
- Skirt and Conductor pile are generally installed in vertical position and the batter is conservatively assumed equals to 1 (included
tolerances)
- For large pile inclinations (over 10) particular measures on the hammer (Menck, Delmag) might be necessary to avoid hammer efficiency
reducing (e.g. hammer stroke) and pile driveability cost increasing.
Legend: True Batter X:12 [e.g. arctg (3:12) =14.04 deg ]. True Batter 1:Y [e.g. arctg (1:1) =45deg)]
13 of 13