0% found this document useful (0 votes)
207 views1 page

Concrete Mix Design RC5001

This document provides a concrete mix design code RC5001 that meets British standards for strength class C40/50 concrete exposed to chlorides. The mix uses 420 kg/m3 of cement, 811 kg/m3 of sand, 992 kg/m3 of 20mm crushed granite coarse aggregate, and 5040 ml/m3 of superplasticizer admixture. The target mean strength is 58 MPa with a water-cement ratio of 0.37 and fine aggregate to total aggregate ratio of 0.45. The concrete density is specified to be 2383 kg/m3.

Uploaded by

shahrilzainul77
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as XLS, PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
207 views1 page

Concrete Mix Design RC5001

This document provides a concrete mix design code RC5001 that meets British standards for strength class C40/50 concrete exposed to chlorides. The mix uses 420 kg/m3 of cement, 811 kg/m3 of sand, 992 kg/m3 of 20mm crushed granite coarse aggregate, and 5040 ml/m3 of superplasticizer admixture. The target mean strength is 58 MPa with a water-cement ratio of 0.37 and fine aggregate to total aggregate ratio of 0.45. The concrete density is specified to be 2383 kg/m3.

Uploaded by

shahrilzainul77
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as XLS, PDF, TXT or read online on Scribd
You are on page 1/ 1

CONCRETE MIX DESIGN

Date: 1st March 2017


Revision No. 0
Mix Code : RC5001

ITEM REMARKS DESCRIPTION / QUANTITY


A Strength Class BS EN 206-1 / BS 8500 C 40 / 50
Exposure Class (DC - Class) BS EN 206-1 / BS 8500 DC-4z
Chloride Class BS EN 206-1 / BS 8500 CI- 0.10
Characteristic Strength at 28 days BS EN 206-1 / BS 8500 50 N/mm2
Standard Deviation 5 %
Margin BS EN 206-1 8 N/mm2
Target Mean Strength BS EN 206-1 58 N/mm2
B Consistence Class:
(a) Slump (Target Values) BS EN 206-1 125 30 mm

C CEM Content Specified max. 550 kg/m3


min. 360 kg/m3 420 kg/m3
Water Content Specified SAJ (Potable Water) 155 kg/m3
Fine Aggregate Content 1. Sand Type Zone C, Natural 811 kg/m3 (SSD)
2. Granite Fine Type - - kg/m3 (SSD)
Coarse Aggregate Content 1. 20 mm Type Crushed Granite 992 kg/m3 (SSD)
2. Type - . kg/m3 (SSD)
Admixture Content 1. Type Superplasticiser 1200 5040 ml/m3
2. Type - ml/100kg - ml/m3

D Water/Cement ratio Specified max. 0.45 0.37


Fine Aggregate/Total Aggreggate ratio Specified max. 0.50 0.45
Total Aggregate/Cement ratio Specified max. - -
Air Content Specified/Estimated 2 %

E CEM type BS EN 197 / MS EN 197 OPC/Other CEM II - PFA Low Heat


100 ~ 150
Bulk/Bag Bulk
S.G. 3.12 Known /Assumed
Fine Aggregate type 1. Sand BS EN 12620 / BS 882 Crushed/Uncrushed
S.G.(SSD) 2.61 Known /Assumed
Grading Zone C
Maximum Fine Aggegates Size (Dmax) 4 mm
Coarse Aggregate type 1. 20 mm BS EN 12620 / BS 882 Crushed/Uncrushed
S.G.(SSD) 2.63 Known /Assumed
Maximum Coarse Aggregate Size (Dmax) 20 mm
Admixture type 1. Superplasticizer BS EN 934 / BS 5075 Name: Various
Dosage rate: Refer to manufacturer's
recommendation
F Density of Concrete Specified - max./min. 2383 kg/m3

G Others

Note: (1) "Designed Concrete" Conforming to BS EN 206-1, BS 8500 Parts 1 and 2.