Wireless, Wearable Physiology Monitoring S!
M O DULE S!
Full-bandwith, high-quality data NEW SIGNAL
E
for a wide range of signals MOR
Comfortable for the subject and
empowering for the researcher
All of the benefits of a wireless
solution with the signal quality &
integrity of a wired system
Wireless Physiology Solutions
BIOPAC proudly introduces the new BioNomadix series of wireless, wearable physiology
monitoring devices for life science research. BioNomadix noninvasively records high quality
data while comfortably allowing subjects to move freely in natural indoor environments.
Developed and manufactured by BIOPAC Systems Inc., a leader in life science data
acquisition and analysis, the BioNomadix line covers a wide range of physiology signals.
BioNomadix devices use digital transmission and short leads placed close to the signal
source to provide excellent signal quality. Amplifiers provide the full signal bandwidth
and are suitable for applications such as heart rate variability.
BioNomadix are typically dual-channel units, offering either two of the same signal or a
combination of signals. BioNomadix are configured for specific signal types. You dont
have to adjust settings on the hardware or software for high quality data.
ECG Dynamometry Impedance Cardiography (NICO)
EEG Respiration Electrodermal Activity
EOG Pulse Accelerometry
EMG Temperature Gyroscope (75 or 300 deg/sec)
EGG Dual Strike (Heel/Toe) Goniometry/Torsiometry
A BioNomadix device consists of two parts, a transmitter that is worn by the subject to
amplify and send the physiological data, and a receiver module. The transmitter unit uses
short leads for easy placement at any point of interest and is easily attached to the body
with soft Velcro straps that come with the system just like attaching a wrist watch
Watch the demo video at
BIOPAC.COM
to learn more about the
power & flexibility of
BioNomadix!
BioNomadix is the next generation of quality BIOPAC research systems
Excellent Signal Quality & Data Integrity 2
Use electrode leads and electrodes for biopotentialsor use BioNomadix transducers.
For accelerometry and (angular) rotation rate, just attach the BioNomadix transmitter
directly to the subjectno lead wires or electrodes required.
Multiple BioNomadix can be used to provide the optimal signal combination for a
research study requiring biopotential or transducer signals. When multiple devices are
in use, the Sync button can be used to identify the matching transmitter and receiver.
When used with a BIOPAC MP System, up to 16 channels of BioNomadix data can
be recorded for multi-subject or multi-parameter protocols. The system also works
with multiple MP150 systems or third-party data acquisition hardware via the Isolated
Power Supply module (IPS100C).
Record BioNomadix data
with one or multiple
MP Systems... or with
3rd-party hardware
BioNomadix setup is fast and efficient. Just attach the transmitter and leads, assign a
channel, turn the system on, and click Start in the AcqKnowledge software to begin
recording high quality data.
AcqKnowledge software adds the power of sophisticated automation and scoring
routines for each signal type, plus customization options. When assigning channels for
the data recording, AcqKnowledge setup wizard guides you through setup.
Increase the power and flexibility of your life science research
Comfortable for Subjects & Empowering for Researchers
Researchers can increase the complexity of experimental design and create compelling
real-world scenarios. BioNomadix is the perfect tool for applications that demand greater
degrees of subject freedom and advanced experimental design.
BioNomadix provides excellent signal quality with digital transmission
and short leads placed close to the signal source.
Eliminating the cables helps with sensitive study populations that dont
like to be tethered.
The small and unobtrusive nature of the BioNomadix helps to relax the
subject and reduce stress and anxiety.
For multi-subject applications, BioNomadix allows multiple devices to work
seamlessly inside an enclosed area.
Comfortable stretch-mesh shirt has 22 transmitter pockets, access zippers &
strap bands for flexible placement of BioNomadix transmitters.
Subjects can freely move around without cables anchoring them to recording
devices and the fear of tripping over other subjects cables.
BioNomadix is small and easy to transport for offsite and home recording.
The BioNomadix system scales extremely well, from limited-channel
applications to multi-sensor studies.
For multi-sensor protocols, the BioNomadix shirt allows participants to wear devices in
natural and well balanced positions for long-term routines.
Exercise Physiology Applications BioNomadix allows a natural, unhindered
environment, which significantly improves the quality of the data and makes it much
easier for subjects to achieve peak performance.
BioNomadix work extremely well
for protocols that demand movement,
such as exercise physiology or virtual
reality immersion studies
No matter what your application,
BioNomadix reduces signal noise
and artifact for faster analysis
Psychophysiology Applications the untethering of the subject and elimination of
major cables greatly enhances the recording experience and helps to provide a relaxed
environment for subjects.
Quality BIOPAC research systems are trusted in thousands of labs
Your Total Solution with Powerful Analysis Tools! 4
For greater freedom, use BioNomadix wireless physiology
with a BIOPAC Research System
Combine the sophistication and performance of BIOPAC data acquisition
hardware with the power and flexibility of AcqKnowledge software to
customize your acquisition and analysis system for life science research.
MP150 Data Acquisition System
High resolution 16 bit
High speed up to 400 kHz aggregate
Variable sample rates (analog & calculation channels)
16 analog inputs and 2 independent analog outputs
Digital I/O lines (receive/send TTL triggers)
16 online calculation channels
Ethernet connectivity fast and efficient
Safety
AcqKnowledge Software
The AcqKnowledge software included with Analysis Features signal averaging,
each MP System is a highly interactive user- sophisticated pulmonary integration routines,
friendly application with intuitive controls filtering, FFT, histogram, automatic data
that lets you instantly view, measure, reduction, template analysis, peak detection
analyze, and transform data. features, find rate settings, and an equation
Perform complex data acquisition, triggering generator
and analysis using simple pull-down
menus and dialogs no need to learn a Remote Monitor view subject data on
programming language or new protocol. another machine bedside monitor display.
Simplified user interface tracks the welfare of
Acquisition Features variable sample the subject with alarms to warn when signals
rates, pause mode, and stimulation design fall out of range. The system will work on
and control. Online analysis settings, filters any device that has access to the same IP
and transformations provide real-time
based network as the MP150.
recording feedback.
Rich Display Features multiple display
modes, advanced grid system, journal
facility for note taking, textual event
markers, and measurement tools. Mouse-
over tool tips (for sample rate, channel
rate, measurement results, etc.) help guide
application use.
Automated Analysis Routines save time Multi-media Support Tools videos for
and standardize intrepretation of results analysis, automation routines, hardware
with scoring and analysis routines for setup, and scripting; real-time, searchable
ECG, HRV, EDA, EMG, EEG, ICG, BP, user guides and application notes (PDF), as
LVP, Pulmonary Function, and more! well as extensive online support, knowledge
BIOPAC Developer Customize and base, and training options. Plus, Module
automate your analysis routines with new Setup Wizard and QuickStart template files
Developer tools including BIOPAC Basic are included to make it even easier to start
Scripting, Network Data Transfer, or API. your experiment.
Download a free AcqKnowledge demo at www.biopac.com
AcqKnowledge Software
AcqKnowledge software is included with BIOPAC Research Systems and provides
comprehensive tools to simplify & standardize advanced analysis.
Standard Analysis Tools
Cycle/Rate Detector Expression Evaluator Autoregressive Modeling
Digital Filters Ensemble Averaging AR Time-Freq Analysis
FFT & PSD Template Analysis Independent Component Analysis
Histogram Wavelet Analysis Principal Component Analysis
Stim-Response Nonlinear Modeling Plotting options - 3D, overlap, X/Y
Automated Advanced Analysis
ECG Analysis ICG Analysis
RSA Analysis
EDA Analysis
ECG - Electrocardiography EDA - Electrodermal Activity
ECG Interval Extraction Derive Phasic EDA from Tonic
Heart Rate Variability Event-related EDA Analysis
Chaos Analysis Locate SCRs
Detect & Classify Heartbeats NICO - Impedance Cardiography
EEG - Electroencephalography Derive dZ/dt from Raw Z
Compute Approximate Entropy Classify dZ/dt : B, C, X, Y, and O
Delta Power Analysis Remove dZ/dt Motion Artifacts
Derive Alpha-RMS ICG Analysis
Derive EEG Frequency Bands VEPT (electrically participating tissue)
EEG Frequency Analysis PEP Pre-ejection Period
Remove Artifact - EOG/eye blink Body Surface Area & Ideal Body Weight
EMG - Electromyography RSP - Respiration
Derive Average Rectified EMG Respiratory Sinus Arrhythmia
Derive Integrated EMG EGG - Electrogastrography
Derive Root Mean Square EMG Gastric Wave Analysis
EMG Frequency & Power Analysis Gastric Wave Coupling
Locate Muscle Activation
Watch dozens of tutorial screencasts
and learn more online!
Get your free AcqKnowledge Demo at www.biopac.com
BioNomadix & Accessories 6
BioNomadix Transmitter/Receiver Pairs
BioNomadix module pairs include a wireless Transmitter
and matched Receiver plus strap and battery charger.
Each module pair emulates a wired connection from
the computer to subject, with all the benefits of a fully
wireless recording system. The module pair incorporates
internal, non-distorting, highpass and lowpass filters to
provide for high quality amplification of the complete
waveform resulting in exceptional quality data.
See specifications page 8-10
BioNomadix are designed and optimized for specific signals:
Dual Channel Biopotential Dual Channel Transducer
BN-ECG2 Electrocardiogram BN-GONIO Goniometry/Torsiometry
BN-EEG2 Electroencephalogram BN-RSP2 Respiration
BN-EGG2 Electrogastrogram BN-SKT2 Temperature
BN-EMG2 Electromyogram BN-STRIKE Heel/Toe Strike
BN-EOG2 Electrooculogram Combination
Specialty
BN-DYNEMG Dynamometry & EMG
BN-ACCL3 Tri-axial Accelerometer BN-NICO Impedance Cardiography
BN-GYRO-75 Gyroscope
75 deg/sec BN-PPGED Pulse & EDA
BN-GYRO-300 Gyroscope 300 deg/sec
BN-RSPEC Respiration & ECG
The signal is transmitted via an ultra-low power, 2.4 GHz bi-directional digital RF
transmitter. The recording transmitter is also extremely safe to use, because there is
no physical connection to supply mains. Interference with other recording modules
or systems is greatly minimized because the module transmitter is completely battery
operated and operates totally independently of any other recording grounds or power.
BioNomadix Accessories
Shirt BN-SHIRT-size (XS, S, M, L, XL)
When multiple transmitters are used, this custom stretch-mesh
shirt provides a greater degree of comfort and mounting flexibility.
Select size for compression fit to hold the BioNomadix transmitter
and sensors in place; wear as is or under clothing.
22 transmitter pockets: chest, back, neck front/back, hip front/back, left/right arm
4 access zippers: right front from arm to hip, left back from shoulder to hip,
right and left under arm from neck front to neck back
4 strap bands: 4 rows of bands for respiration strap (2 loops front, 2 loops back)
Straps BN-STRAP-size (20, 30, 76, 137 cm)
Each system includes a strap for common signal type applications. Additional straps are
available to fit wrist, head, leg, chest, etc. (sized in cm: BN-STRAP-20 is 20 cm).
Charger BN-BAT-CHRG
Battery life for most modules is 70-90 hours. Full charge in approximately one hour.
Charger provides a lifespan of about 500 charge cyclesor 35,000 hours!
BioNomadix with AcqKnowledge is an incredible research tool!
BioNomadix Transducers & Accessories
Transducers
Respiration BN-RESP-XDCR Measure changes in thoracic
or abdominal circumference as subject breathes.
Pulse BN-PULSE-XDCR, BN-PULSEEAR-XDR Infrared
emitter and photo-diode transmit changes in infrared
reflectance from varying blood flow; finger or ear.
Temperature BN-TEMP-A-XDCR Skin tempresponse time 1.1 sec.
Stainless steel banjo design; tape to body.
BN-TEMP-B-XDCR Rapid temperature change (i.e., temp
changes of inspired/expired breath). Response time 0.6 sec.
Dynamometry BN-CLENCH-XDCR Clench bulb dynamometer measures
proportionality of clench force to pressure on the bulb.
EEG Cap System BN-EEGCAP-SYS Cap system (19 electrodes, 10/20
montage) with accessories. Requires BN-ADAPT-TP2/TP3.
BN-CAP-SIZE Small 50-54 cm, Medium 54-58 cm,
Large 58-62 cm
Strike BN-STRIKE-XDCR Record heel/toe strike activity as
subject walks.
Goniometery BN-GON-110-XDCR, BN-GON-150-XDCR Twin-axis
goniometers, 110 mm or 150 mm, measure angular
movement of limb.
Torsiometry BN-GON-F-XDCR Finger goniometer, 35 mm, measures
polycentric joint movement.
BN-TOR-110-XDCR, BN-TOR-150-XDCR Torsiometers, 110 mm
or 150 mm, measure axial rotation about a single plane.
Electrodes & Electrode Leads
Mini-pinch two-lead or three-lead in 15 cm, 30 cm, or 45 cm
BN-EL15-LEAD2 BN-EL15-LEAD3
BN-EL30-LEAD2 BN-EL30-LEAD3
BN-EL45-LEAD2 BN-EL45-LEAD3
Touchproof adapters: 15 cm, sockets accept TP leads
BN-ADAPT-TP2 BN-ADAPT-TP3
EDA lead: use with disposable EDA electrodes
BN-EDA-LEAD2
NICO leads: 50 cm clip leads - 2 x alligator or 4 x mini-pinch
BN-EL50-LEAD2 BN-EL50-LEAD4
Disposable electrodes: vinyl or cloth, pre-gelled or dry
EL500 series
www.biopac.com
BioNomadix Module Specs
Dual Channel Biopotential Table 1
Dual Channel Transducer & Combination Table 2, page 9-10
Specialty Table 3, page 9-10
Common Specs - all modules Table 4, page 9-10
Table 1: Dual Channel Biopotential
watch demo videos at WWW.BIOPAC.COM
BioNomadix Module SpecsBiopotential
Specifications subject to change without notice. 11/13
8
BioNomadix Module Specs
BioNomadix Module Specs
Dual Channel Biopotential
Dual Channel Transducer & Combination
Specialty
Common Specs - all modules
Table 2: Dual Channel Transducer & Combination
Table 3: Specialty
watch demo videos at WWW.BIOPAC.COM
Transducer, Combination & Specialty 10
Table 1, page 8
Table 2
Table 3
Table 4
Table 4: Common Specs - All Modules
, , ,
Specifications subject to change without notice. 11/13
WWW.BIOPAC.COM
Wireless, Wearable Physiology
Life Science Monitoring Devices 42 Aero Camino
Two-Channel Sets Goleta, CA 93117
Dual ECG Dual EEG
Dual EOG Dual EMG
Dual EGG Dual Temperature
Dual Respiration
Respiration with ECG
Electrodermal Activity with Pulse
Impedance Cardiography
Heel/Toe Strike
Dynamometry with EMG
Goniometry & Torsiometry
Accelerometry
Gyroscope
[email protected]