The document summarizes the history of turbine controls from Mark I in 1966 to Mark VIe in 2004. Key developments include the introduction of solid-state components in Mark II, microprocessors in Mark IV, distributed control processors in Mark V, and upgradable CPUs and network connectivity in later models. Operator interfaces transitioned from analog meters and switches to digital monitors and PCs running Windows and Cimplicity GUI software.

Uploaded by

Khalid Ejaz
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
109 views

Turbine Controls History

The document summarizes the history of turbine controls from Mark I in 1966 to Mark VIe in 2004. Key developments include the introduction of solid-state components in Mark II, microprocessors in Mark IV, distributed control processors in Mark V, and upgradable CPUs and network connectivity in later models. Operator interfaces transitioned from analog meters and switches to digital monitors and PCs running Windows and Cimplicity GUI software.

Uploaded by

Khalid Ejaz
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 1

Turbine Controls History

Mark I Mark II Mark IV Mark V Mark VI Mark VI e


Introduced 1966 1973 1982 1991 1997 2004
Shipments 850 2181 1080 3411 915
Application Gas Turbine Gas Turbine Gas Turbine Gas / Steam Turbine / BOP Governor / BOP
Relays for Discrete Solid-state Complete Upgradable CPUs. Upgradable CPUs.
Sequencing & for Sequencing. IC's Microprocessor Distributed VME Backplane. cPCI Backplane.
Discrete Solid-state & Microprocessor for Based. 8086/80286. Processors 186/196. Distributed Networked I/O.
Technology for Control Control Proprietary Backplane Proprietary Backplane Controllers Local/Remote
Redundancy Single Single Single / Triple Single / Triple Single / Triple Single / Dual / Triple
Meters, PBs, Meters, PBs, Black & White PC. Initially
Operator Switches, Relay Switches, Solid-state Monitor with Proprietary. Later Windows PC with Windows PC with
Interface Annuniciator Annuniciator Membrane PBs Windows, Cimplicity Cimplicity GUI Cimplicity GUI

Third Party Modbus & Ethernet


Modbus, Ethernet Modbus, Ethernet
Interface Hardwired Hardwired Serial & Proprietary TCP-IP GSM GSM, OPC, DNP 3.0 GSM, OPC, DNP 3.0
10MB Ethernet, Peer- 100MB Ethernet,
to-Peer Peer-to-Peer
Networks NA NA NA Arcnet Communications Communications
Maintenance Analog Cablibration, Analog Cablibration, Software Calibration, Software Calibration,
Interface Pots, Timers Pots, Timers Software Calibration Software Calibration Windows Based Windows Based