67% found this document useful (3 votes)
3K views39 pages

Alcatel OmniPCX Enterprise Hardware Overview

This document describes the hardware components and board configurations for Alcatel OmniPCX Enterprise systems. It outlines the different processing units including the Call Server (CS), Media Gateway Driver (GD), Media Gateway Applicative (GA), and "In-the-skin" IP Server. It provides details on board locations, daughter boards, and front panel connections for each processing unit type. The document also includes diagrams illustrating the board layouts and components.

Uploaded by

Ioryogi Kun
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
67% found this document useful (3 votes)
3K views39 pages

Alcatel OmniPCX Enterprise Hardware Overview

This document describes the hardware components and board configurations for Alcatel OmniPCX Enterprise systems. It outlines the different processing units including the Call Server (CS), Media Gateway Driver (GD), Media Gateway Applicative (GA), and "In-the-skin" IP Server. It provides details on board locations, daughter boards, and front panel connections for each processing unit type. The document also includes diagrams illustrating the board layouts and components.

Uploaded by

Ioryogi Kun
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
  • Overview and Hardware Description
  • System Capacity and Configuration
  • Rack Configurations
  • Processing Units and Boards
  • Interface and Extension Boards
  • Auxiliary Boards and Restrictions
  • Crystal Hardware Platforms
  • Common Platform Hardware

Alcatel OmniPCX Enterprise

Hardware description
Overview
OmniPCX Enterprise

Stand Alone

 5000 legacy users / 4000 IP-Phones


 90 Crystal IP-MG/IP-MG

Network

 50000 Users
 100 Nodes
 R4.2/R4.2.1, R5.0 Ux/Lx and R5.1 will be fully compatible in Network
 The network link possibilities depend on the hardware configuration used

Alcatel-Lucent Internal
Proprietary Use pursuant to Company instruction.
OmniPCX Enterprise
Board positioning in racks

Rack 1U (Small)

CS, GD or MEX

CPU

position 1 position 2

Alcatel-Lucent Internal
Proprietary Use pursuant to Company instruction.
OmniPCX Enterprise
Board positioning in racks

Rack 3U (Large) GD or MEX

CPU

position 1 position 2
position 3 position 4 position 5
position 6 position 7 position 8

Alcatel-Lucent Internal
Proprietary Use pursuant to Company instruction.
OmniPCX Enterprise Processing units

Processing units and daughter boards with their location


Name Function Location
CS Call Server IP MG
GD Media Gateway Driver IP MG
GA Media Gateway Applicative IP MG
16 Mbits/s link for expansion
MEX IP MG
rack
INTIP B ACT-MG over IP link ACT-MG
Xmem IDE controller for hard disk CS
Multi Channel Vocoder
MCV8 or MCV24 VoIP compression resources GD,GA
7 or 21 compressors
High Speed Link
HSL1, HSL2 GD, MEX
Expansion cabinet connection
Ethernet LAN switch
Slanx CS,GA
3 ports +1 up-link
AFU Auxiliary Function Unit GD

Alcatel-Lucent Internal
Proprietary Use pursuant to Company instruction.
OmniPCX Enterprise
Processing units - "In-the-skin" IP Server (IP RS)

CS

 Can be plugged in slot 8 (3U rack) or in a slot 0 (dedicated rack for e-CS)
 Connected to the back panel only to get the power supply

 Main characteristics

 Processor : ASPEN 133MHz


 Memory : S-DRAM 128 MBytes + basic NAND flash 32 MBytes
 Hard disk
 Connectors on front panel
 1 Ethernet 10/100 Base-T
 1 V24 access
 ON/OFF switch button

Alcatel-Lucent Internal
Proprietary Use pursuant to Company instruction.
OmniPCX Enterprise
Processing units - "In-the-skin" IP Server (IP RS)

CS front panel

LAN connection
or directly to GD
Not used

SlanX accesses (4 ports) V24 port


ON/OFF switch
(system console)

Alcatel-Lucent Internal
Proprietary Use pursuant to Company instruction.
OmniPCX Enterprise
Processing units - "In-the-skin" IP Server (IP RS)

CS daughter boards

 Xmem
 IDE controller for hard disk (where is located the e-CS software)

 SlanX
 10/100 Mbits/s base-T ethernet LAN switch
 3 crossed ports and 1 straight port (uplink)
 Auto-negotiation (full/half duplex)
 Flow control

Alcatel-Lucent Internal
Proprietary Use pursuant to Company instruction.
OmniPCX Enterprise
Processing units - "In-the-skin" IP Server (IP RS)

CS board description

Xmem daughter board IP LAN


SLANX
+ hard disk Daughter board
Back panel connector

0-11PCM
X
DSP0
P
ASL X
XCHANGE
X
DSP1
METRIC

SDRAM (128 Mbytes)

Alcatel-Lucent Internal
Proprietary Use pursuant to Company instruction.
OmniPCX Enterprise
Processing units - Media Gateway Driver

GD

 All the intelligence of the IP Media Gateway is concentrated in the GD (no


firmware in other boards)

 Always in slot 0
1 Available position
 Main characteristics
 Processor : ASPEN 133MHz
 Memory : S-DRAM 64 MBytes + basic NAND flash 32 MBytes
 Connectors on front panel
 1 Ethernet 10/100 Base-T
 1 V24 access
 Switch ON/OFF button

Alcatel-Lucent Internal
Proprietary Use pursuant to Company instruction.
OmniPCX Enterprise
Processing units - Media Gateway Driver

GD front panel
V24 port
LAN connection or
(config., maintenance)
directly to CS

expansion expansion AFU ON/OFF switch for the


rack 1 rack 2 features power supply of the module

Alcatel-Lucent Internal
Proprietary Use pursuant to Company instruction.
OmniPCX Enterprise
Processing units - Media Gateway Driver

GD daughter boards

 MADA 1 or 3
 DSPs for voice compression in Voice over IP applications.
 G.711, G.723.1, G.729,
 DTMF generation and detection, group 3 fax relay.

 AFU
 Connection of external tuner, tape recorder,...
 Connection of external Loudspeaker.

 HSL
 Two HSL connectors allow connection of up to 2 expansion racks,
 One HSL consists in 254 Time Slots.
Alcatel-Lucent Internal
Proprietary Use pursuant to Company instruction.
OmniPCX Enterprise
Processing units - Media Gateway Driver

GD board description

MADA1 or 3 AFU
IP LAN
daughter board Daughter board
2 * HSL
(VoIP compressors)
HSL
Back panel connector

Daughter board
0-11PCM
DSP0

ASL
XCHANGE P
DSP1
METRIC

SDRAM (64 Mytes)

Alcatel-Lucent Internal
Proprietary Use pursuant to Company instruction.
OmniPCX Enterprise
Processing units - GA

GA

 Applicative processing unit plugged in a coupler position of the IP MG


 Used to provide additional resources
 VoIP compressors
Number of channels depends on the daughter board used
MADA1 or 3

 Voice guides broadcast (4 languages max), 3 x "3 parties conference"


thanks to the GA DSP0

 Communication with GD only (using 2 PCM)

 Other boards are not seen


 Must be plugged in a coupler position with 2 PCM

Alcatel-Lucent Internal
Proprietary Use pursuant to Company instruction.
OmniPCX Enterprise
Processing units - GA

GA board description

MADA1 or 3 IP LAN
daughter board SLANX
(VoIP compressors) Daughter board
Back panel connector

0-11PCM
DSP0

ASL
XCHANGE P
DSP1
METRIC

SDRAM

Alcatel-Lucent Internal
Proprietary Use pursuant to Company instruction.
OmniPCX Enterprise
Processing units - MEX

Plugged into slot 0 of an expansion rack

 Insures the control of its remote rack


 Up to 2 expansion racks can be connected on a main rack

Connected to the main rack (GD) through a HSL link

 16 Mbits/s link (5 meter shield cable maximum)


 Using HSL daughter boards

The MEX board DSP0 receives from the DSP0 of the GD the switching
information

A virtual GPA is also associated to each MEX board

Alcatel-Lucent Internal
Proprietary Use pursuant to Company instruction.
OmniPCX Enterprise
Interface boards : extension interfaces

Interface boards

N am e F u n ctio n Lo ca tio n
U A I 4 ,8 ,1 6 4 ,8 o r 1 6 d ig ita l e q u ip m e n ts IP M G
S LI 4 ,8 ,1 6 4 ,8 o r 1 6 a n a lo g e q u ip m e n ts IP M G
In te rfa ce s fo r 8 R a d io B a se
D EC T8 A C T -M G
S ta tio n s

Alcatel-Lucent Internal
Proprietary Use pursuant to Company instruction.
OmniPCX Enterprise
Interface boards : extension interfaces

UAI (Universal Alcatel Interface)

 Digital equipment connection

 4, 8 or 16 UA equipments
 UAG2
 UAG3
 Attendants
 IBS
 TSC and terminal adapters

 Restrictions
 No UAI board in 8th slot of rack Large when MCV24 plugged on the GD (the PCM of the
position 8 is reserved for the MCV24)
 No UAI16 in slot 5 to 8 of rack Large (because only one PCM available)

Alcatel-Lucent Internal
Proprietary Use pursuant to Company instruction.
OmniPCX Enterprise
Interface boards : extension interfaces

SLI (Single Line Interface)

 Analogue equipments connection


 Sets
 Modem
 Fax

 4, 8 or 16 equipments

 Supports Q23 and decadic dialling mode

 No MF Q23 detectors (use of DSP0 detectors)

 Restrictions
 No SLI16 in rack Small
 No SLI board in 8th slot of rack L when MCV24 plugged on GD

Alcatel-Lucent Internal
Proprietary Use pursuant to Company instruction.
OmniPCX Enterprise
Interface boards : external access interfaces

Digital access boards (private or public network)


Name Function Location
BRA 2,4,8 2,4 or 8 ISDN Basic accesses IP MG
PRA T2 1 x 2Mbit/s access IP MG
PRA T1 1 x 1,544Mbit/s access IP MG
2Mbit/s Pulse Code
PCM2 ACT-MG
Modulation interface

Alcatel-Lucent Internal
Proprietary Use pursuant to Company instruction.
OmniPCX Enterprise
Interface boards : external access interfaces

Digital interfaces

 BRA (Basic Rate Interface)


 T0 interfaces (2B+D)
S0 FV leased line
public ISDN access
 2, 4 or 8 accesses
 S0 mode not available
 PRA T1 (Primary Rate Access T1)
 1 x 1,544 Mbits T1 interface
public ISDN access
ABC-F Network links
 Available in CCS mode (23B+D) or CAS mode (24B)
 PRA T2
 1 x 2 Mbits E1 (T2) access
public ISDN access, ABC-F Network links

Alcatel-Lucent Internal
Proprietary Use pursuant to Company instruction.
OmniPCX Enterprise
Interface boards : mixed interfaces

Mixed boards (extension and external accesses interfaces)

 Offers BRA, UA and Z functions


Nam e N u m b e r o f T0 Num ber of UA Num ber of Z Lo c a tio n

M IX 4 8 4 4 8 4 IP M G
M IX 4 4 8 4 4 8 IP M G
M IX 2 4 4 2 4 4 IP M G
M IX 0 4 8 0 4 8 IP M G
M IX 0 8 4 0 8 4 IP M G
M IX 0 4 4 0 4 4 IP M G

 2 PCMs are required for a MIX board

 No MIX boards in slot 5 to 8 of rack Large (because only one PCM available)

Alcatel-Lucent Internal
Proprietary Use pursuant to Company instruction.
OmniPCX Enterprise
Interface boards : external access interfaces

Analogue access boards (public operator, inter PABX)


Name Function Location
APA 4,8 4 or 8 analog interfaces IP MG
6 analog trunks for private tie
EMTL ACT-MG
line
4 analog trunks for private tie
ACEM ACT-MG
line

 APA

 4 or 8 analogue equipment for public/PSTN trunk

Alcatel-Lucent Internal
Proprietary Use pursuant to Company instruction.
IP Rack Server
Auxiliary boards

Auxiliary boards

 LANX8, LANX16
 Switch 10/100 Base T (autodetection)
 8 or 16 ports ( 1 is crossed ( Uplink ))

 RMA
 Secured remote access
for maintenance

 MODB
 Board supporting 1 external modem

 To manage the power supply


of the rack dedicated to RMA
Alcatel-Lucent Internal
Proprietary Use pursuant to Company instruction.
OmniPCX Enterprise
Restrictions / limits

Maximum number of PRA T1/T2


 1 in rack S and 3 in rack L

If MCV24 is used in rack L


 Slot 8 is useless (except for CS)

ISDN accesses

 12 accesses (T2, T1 and/or T0) maximum per IP MG

 No S0 on BRA or MIX interfaces

 Synchronization not transmitted from expansion rack to main rack

 Only accesses of the main rack can synchronize the whole IP MG


Alcatel-Lucent Internal
Proprietary Use pursuant to Company instruction.
OmniPCX Enterprise
Boards unplug

Warning :

 To unplug a CPU CS you have first to switch it off

 The couplers boards are hot pluggable

Alcatel-Lucent Internal
Proprietary Use pursuant to Company instruction.
Crystal hardware

CPU6 Step2

 Integration of the CPU id

 Memory capacity increase (from 64 to128 Mo)

NPRAE (New Primary Rate Access on E1 interface)

 2 E1 accesses E1

 Various signaling protocols available:

 T2, ABC-F, QSIG, QSIG_GF & ISDN

Alcatel-Lucent Internal
Proprietary Use pursuant to Company instruction.
Crystal hardware

GPA2-2 (General Purpose Auxiliary)

 MFR1/MFR2 Frequencies sending

 MLVP function (Multi Language Voice Prompt) (2)

 Conference function (up to 30 participants)

 Usual frequencies detection

 VAD detection (Voice Activity Detection)


 At least one detection function whatever the board configuration is (in opposite to the
GPA board)

Alcatel-Lucent Internal
Proprietary Use pursuant to Company instruction.
Crystal hardware

INTIP2 (INTerconnecting on IP network)

 Main processor update

 V24 port connection modification


 Use of the same cable than the one used for CS, GD & GA boards

 Addition of the V36 interface


 WAN access

10 Mb/s max on X24/V11

1920 Kb/s max on V36

Alcatel-Lucent Internal
Proprietary Use pursuant to Company instruction.
Crystal hardware

eUA32 & eZ32 (Legerity)

 Cost reduction for the customer

 Specific dedicated licenses are mandatory for UA and Z extensions (check of


the UA & Z extensions management)

 Impossibility to declare an UA32/Z32 board while using an eUA32/eZ32 board

Alcatel-Lucent Internal
Proprietary Use pursuant to Company instruction.
Crystal Platform
Crystal hardware - CPU7

CPU7

 Replaces the CPU5

 Processing unit
 INTEL PENTIUM III LP processor 700MHz

 System memory
 SDRAM technology
256 Mb

 The embedded Ethernet link can be disabled by software, even if the


corresponding on board jumper is present

 Force the Ethernet output bandwidth to 10 or 100 Mb, Half or Full duplex mode
(auto-sense is the default mode)
Alcatel-Lucent Internal
Proprietary Use pursuant to Company instruction.
Crystal hardware - CPU7

CPU7 functionalities

 IO1
 CPU signaling

 Clock and frame synchronization signals

 Tones generation

 Q23 signaling detection


Q23
Q23x

 DECT Timing Module (DTM) function


Synchronization of the IBS and RBS

 External Music function

Alcatel-Lucent Internal
Proprietary Use pursuant to Company instruction.
Crystal hardware - CPU7

CPU7 restrictions

 This Board does not support any daughter boards

 No VMU
 No OBCA (use of IO2N(1) if required)

 Only one DSP (used for the DTM function) instead two for the CPU6

 With CPU6, the second DSP was used for the VPU function (voice Processing Unit)

Alcatel-Lucent Internal
Proprietary Use pursuant to Company instruction.
Crystal hardware
GIP4-1/GIP4-4 compression daughter board

Compression daughter board which replaces GIP6 daughter boards on


INTIP/INTIP2 boards

Whatever the algorithm (G711, G723 or G729) and depth of echo cancellation are
used, a DSP provides 8 compressors

64ms echo cancellation(1) compatibility

Two type of GIP4

 GIP4-4 has 4 DSP and can provide up to 32 compressors

 GIP4-1 has 1 DSP and can provide up to 8 compressors

Alcatel-Lucent Internal
Proprietary Use pursuant to Company instruction.
Crystal hardware
GIP4-1/GIP4-4 compression daughter board

When two compression daughter boards on an INTIP2, both must be the same
type

 2 GIP4-4 or 2 GIP4-1

In case of two GIP4-4, there is only a maximum of 60 (2*30) compressors


available on the INTIP/INTIP2 board (because of internal board PCMs)

Configuration of the compression daughter board is done at the (INTIP) board


level (mgr/Shelf / Board Review/Modify)

Alcatel-Lucent Internal
Proprietary Use pursuant to Company instruction.
Common Platform
Common hardware
MADA-1/MADA-3 compression daughter board

Compression daughter board which replaces MCV8 and MCV24 daughter boards
on GD/GA boards

Two types of MADA (configurable at the board level) (1)

 MADA3 has 3 DSP and can provide(2) up to 24 compressors


 MADA1 has one DSP and can provide up to 8 compressors

Whatever the algorithm (G711, G723 or G729) and depth of echo cancellation are
used, a DSP provides 8 compressors

There is only one MADAx daughter board on a GD/GA

64ms echo cancellation(3) compatibility

Alcatel-Lucent Internal
Proprietary Use pursuant to Company instruction.
Common hardware
New Racks

Powered by 110V or 220V With/without Battery (R5.1.2)

 Offers a low cost alternative to UPS solution

 Up to 8 hours autonomy

 Reference for the 1U Rack


110V / 220V (1) : 3EH 76020 AEAB

 Reference for the 3U Rack


110V: 3EH 76027 BEAB
220V: 3EH 76027 AEAB

Alcatel-Lucent Internal
Proprietary Use pursuant to Company instruction.

You might also like