pressure instrumentation
1.1.2.
Badotherm model industrial BDT1 series are available as
100/160 mm dia. Suitable for all gaseous and liquid media that will not
obstruct the pressure system or attack copper alloy parts.
Slim bayonet casing black painted.
industrial heavy duty pressure gauge
mounting variations
type A bottom connection, direct mounting
type B panel mounting, clamp fixing, back connection
BDT1 type C surface mounting, bottom connection
type D back connection, direct mounting
type E panel mounting, back connection
type F panel mounting, bottom connection
technical specification model BDT1
diameter connection window ranges
100/160 1/2 BSP/NPT glass from -1/1600 bar
casing tube movement dial
steel bayonet copper alloy brass aluminium
bezel socket pointer accuracy
steel bayonet brass fixed 1.0% FSD
options and special executions at extra cost
casing AISI304 type BDT1-08
bezel AISI304 type BDT1-08
window plastic
dials customized i.e., non standard ranges or logos
certificates calibration -; conformity -; material
manuals installation and maintenance
pointer adjustable slotted
connection METRIC; BSPT; acc JIS in various sizes
restrictor brass
connection position top or side
receiver gauge 3-15 psi; 0.2-1 bar; 0-100% lin; 0-10 sq.rt.
drag-pointer system for dia 100/160 mm
red pointer only 100 mm
with contact devices BDT31-01 series
special version black painted case and chromed bezel BDT1-02
(only 100mm)
52 For technical data sheets and dimensional drawings please refer to our website www.badotherm.com
12/06/2007 rev 2-B
BDT1 - technical data sheet
pressure details
working pressure
Steady /4 x full scale value
3
Fluctuating /3 x full scale value
2
Short time see over-pressure table
pressure element over-pressure
<100 bar 100 bar max. scale in bar over-pressure at 20 C
BDT1 Copper alloy AISI316 -1 to 100 1,25 x full scale value
Note : <100 bar c-tube, 100 bar helical 101 to 600 1,15 x full scale value
601 to 1600 1,10 x full scale value
Note : only withstand for a short period of time
temperature details
temperature limitations
ambient process The variation of indication caused by the effects of tem-
perature shall not exceed :
standard -40 C to 60 C 65 C
0,04 x (ambient temperature-reference temperature)%
for hard soldering -40 C to 60 C 200 C
of the span
design information
ingress protection design
IP 54 per EN 60 529 / IEC 529 EN 837-1
drawings
type A type D
dimensions
ns d d1 L H h weight
100 101,5 99 50 140 83 0,60 kg
160 161 159 50 205 83 0,90 kg
Note : dimensions are in mm