Calibration For TCS-JEJC Series

To calibrate the TCS-JE/JC series scale, follow these steps: 1) Turn on the scale while holding the ENTER key and input code 357. 2) Load the standard weight and wait for stability. 3) Input the known value of the standard weight and press ENTER to confirm. 4) Calibration is complete when "Load-in" is displayed. To cancel or set the unit price and total amount windows to two decimal places, turn on the scale while holding ENTER when "CAL" is displayed and input code 307.

Uploaded by

jaredmatias
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (3 votes)
14K views1 page

Calibration For TCS-JEJC Series

To calibrate the TCS-JE/JC series scale, follow these steps: 1) Turn on the scale while holding the ENTER key and input code 357. 2) Load the standard weight and wait for stability. 3) Input the known value of the standard weight and press ENTER to confirm. 4) Calibration is complete when "Load-in" is displayed. To cancel or set the unit price and total amount windows to two decimal places, turn on the scale while holding ENTER when "CAL" is displayed and input code 307.

Uploaded by

jaredmatias
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 1

Calibration for TCS-JE/JC Series

1. Press the ENTER key and hold it, then turn on the scale. When scale shows below,
please input the code 357

2. When scale shows below, please load the standard weight on the platform

3. After stable, scale will shows Load-in, now please input the value (for example
200.00kg) for the standard weight and press ENTER key to confirm.

4. Then screen shows below, the calibration is finished

Cancel or set two decimal places for the Unit Price and Total Amount window.
Press the ENTER key and hold it, then turn on the scale. When scale shows CAL,
please input the CODE 307, and press the ENTER key. Then the two decimal places
will be canceled.
Remark:
No.1: If you want to return the two decimal places mode, please follow to operate
the step 5 one more time.