This document provides specifications for a boiler and deaerator water tank. The boiler is rated at 220 tons per hour and has a feedwater capacity of 249.485 tons per hour at a density of 909 kilograms per cubic meter. The deaerator minimum volume is 249.485 tons per hour and operates at a pressure of 0.588 megapascals. The deaerator water tank capacity is 50 cubic meters per hour, meeting the requirement of 10 minutes of boiler feedwater capacity according to the detailed specification.
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0 ratings0% found this document useful (0 votes)
1K views
Deaerator Volume Calculation Report
This document provides specifications for a boiler and deaerator water tank. The boiler is rated at 220 tons per hour and has a feedwater capacity of 249.485 tons per hour at a density of 909 kilograms per cubic meter. The deaerator minimum volume is 249.485 tons per hour and operates at a pressure of 0.588 megapascals. The deaerator water tank capacity is 50 cubic meters per hour, meeting the requirement of 10 minutes of boiler feedwater capacity according to the detailed specification.
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 1
Boiler rated t/h 220
Boiler feedwater capacity t/h 249.485
3 Boiler feedwater density kg/m 909 3 Boiler feedwater capacity m /h 274.460
Deaerator minimum volume t/h 249.485
Deaerator pressure MPa 0.588
Deaerator water tank capacity of
11min Boiler feedwater capacity the present project Deaerator water tank capacity m3/h 50 Capacity required by detailed 10min Boiler feedwater capacity specification Meeting the requirement