5-11 (Codigos de Error Hyundai 380) PDF
5-11 (Codigos de Error Hyundai 380) PDF
1. OUTLINE
  When any abnormality occurs in the ADVANCED CAPO system caused by electric parts malfunction
  and by open or short circuit, the MCU diagnoses the problem and sends the error codes to the
  cluster and also stores them in the memory.
2. MONITORING
 1) Active fault
21093CD66
21093CD66A 21093CD66B
The active faults of the MCU or engine ECM can be checked by this menu.
2) Logged fault
21093CD66C
21093CD66D 21093CD66E
The logged faults of the MCU or engine ECM can be checked by this menu.
3) Delete fault
21093CD66F
21093CD66G 21093CD66H
The logged faults of the MCU or engine ECM can be deleted by this menu.
                                            5-14
3. MACHINE ERROR CODES TABLE
   Error code
                                                         Description
 HCESPN FMI
              3   Hydraulic oil temperature sensor circuit - Voltage above normal, or shorted to high source.
   101
              4   Hydraulic oil temperature circuit - Voltage below normal, or shorted to low source.
              0   Working pressure sensor data above normal range.
              1   Working pressure sensor data below normal range.
   105
              2   Working pressure sensor data error.
              4   Working pressure sensor circuit - Voltage below normal, or shorted to Low source.
              0   Travel oil pressure sensor data above normal range.
              1   Travel oil pressure sensor data below normal range.
   108
              2   Travel oil pressure sensor data error.
              4   Travel oil pressure sensor circuit - Voltage below normal, or shorted to low source.
              0   Main pump 1 (P1) pressure sensor data above normal range.
              1   Main pump 1 (P1) pressure sensor data below normal range.
   120        2   Main pump 1 (P1) pressure sensor data error.
                  Main pump 1 (P1) pressure sensor circuit - Voltage below normal, or shorted to low
             4
                  source.
             0    Main pump 2 (P2) pressure sensor data above normal range.
             1    Main pump 2 (P2) pressure sensor data below normal range.
   121       2    Main pump 2 (P2) pressure sensor data error.
                  Main pump 2 (P2) pressure sensor circuit - Voltage below normal, or shorted to low
             4
                  source.
             0    Overhead pressure sensor data above normal range.
             1    Overhead pressure sensor data below normal range.
   122
             2    Overhead pressure sensor data error.
             4    Overhead pressure sensor circuit - Voltage below normal, or shorted to low source.
             0    Negative 1 pressure sensor data above normal range.
             1    Negative 1 pressure sensor data below normal range.
   123
             2    Negative 1 pressure sensor data error.
             4    Negative 1 pressure sensor circuit - Voltage below normal, or shorted to low source.
             0    Negative 2 Pressure sensor data above normal range.
             1    Negative 2 Pressure sensor data below normal range.
   124
             2    Negative 2 Pressure sensor data error.
             4    Negative 2 Pressure sensor circuit - Voltage below normal, or shorted to low source.
             0    Pilot pump (P3) pressure sensor data above normal range.
             1    Pilot pump (P3) pressure sensor data below normal range.
   125
             2    Pilot pump (P3) pressure sensor data error.
             4    Pilot pump (P3) pressure sensor circuit - Voltage below normal, or shorted to low source.
             0    Boom up pilot pressure sensor data above normal range.
             1    Boom up pilot pressure sensor data below normal range.
   127
             2    Boom up pilot pressure sensor data error.
             4    Boom up pilot pressure sensor circuit - Voltage below normal, or shorted to low source.
             0    Arm in/out & bucket in pilot pressure sensor data above normal range.
             1    Arm in/out & bucket in pilot pressure sensor data below normal range.
   133       2    Arm in/out & bucket in pilot pressure sensor data error.
                  Arm in/out & bucket in pilot pressure sensor circuit - Voltage below normal, or shorted to
             4
                  low source.
 Some error codes are not applied to this machine.
                                                  5-15
   Error code
                                                         Description
 HCESPN FMI
              0   Swing pilot pressure sensor data above normal range.
              1   Swing pilot pressure sensor data below normal range.
   135
              2   Swing pilot pressure sensor data error.
              4   Swing pilot pressure sensor circuit - Voltage below normal, or shorted to low source.
              0   Attachment pilot pressure sensor data above normal range.
              1   Attachment pilot pressure sensor data below normal range.
   138
              2   Attachment pilot pressure sensor data error.
              4   Attachment pilot pressure sensor circuit - Voltage below normal, or shorted to low source.
              5   Pump EPPR valve circuit - Current below normal, or open circuit.
   140
              6   Pump EPPR valve circuit - Current above normal.
              5   Boom priority EPPR valve circuit - Current below normal, or open circuit.
   141
              6   Boom priority EPPR valve circuit - Current above normal.
              5   Travel EPPR valve circuit - Current below normal, or open circuit.
   143
              6   Travel EPPR valve circuit - Current above normal.
              5   Attachment flow EPPR valve circuit - Current below normal, or open circuit.
   144
              6   Attachment flow EPPR valve circuit - Current above normal.
              5   Remote cooling fan EPPR valve circuit - Current below normal, or open circuit.
   145
              6   Remote cooling fan EPPR valve circuit - Current above normal.
              5   Left rotate EPPR valve circuit - Current below normal, or open circuit.
   150
              6   Left rotate EPPR valve circuit - Current above normal.
              5   Right rotate EPPR valve circuit - Current below normal, or open circuit.
   151
              6   Right rotate EPPR valve circuit - Current above normal.
              5   Left tilt EPPR valve circuit - Current below normal, or open circuit.
   152
              6   Left tilt EPPR valve circuit - Current above normal.
              5   Right tilt EPPR valve circuit - Current below normal, or open circuit.
   153
              6   Right tilt EPPR valve circuit - Current above normal.
              5   Power max solenoid circuit - Current below normal, or open circuit.
   166
              6   Power max solenoid circuit - Current above normal.
              5   Travel speed solenoid circuit - Current below normal, or open circuit.
   167
              6   Travel speed solenoid circuit - Current above normal.
              5   Attachment pressure solenoid circuit - Current below normal, or open circuit.
   168
              6   Attachment pressure solenoid circuit - Current above normal.
              5   Attachment conflux solenoid circuit - Current below normal, or open circuit.
   169
              6   Attachment conflux solenoid circuit - Current above normal.
              5   Arm regeneration solenoid circuit - Current below normal, or open circuit.
   170
              6   Arm regeneration solenoid circuit - Current above normal.
              5   Attachment safety solenoid circuit - Current below normal, or open circuit.
   171
              6   Attachment safety solenoid circuit - Current above normal.
              5   Remote cooling fan reverse solenoid circuit - Current below normal, or open circuit.
   181
              6   Remote cooling fan reverse solenoid circuit - Current above normal.
              5   Fuel level sensor circuit - Voltage above normal, or shorted to high source.
   301
              6   Fuel level sensor circuit - Voltage below normal, or shorted to low source.
                  Engine coolant temperature sensor circuit - Voltage above normal, or shorted to high
             3
                  source.
   304
                  Engine coolant temperature sensor circuit - Voltage below normal, or shorted to low
             4
                  source.
   310       8    Engine speed signal error - Abnormal frequency or pulse width.
             3    Engine preheat relay circuit - Voltage above normal, or shorted to high source.
   322
             4    Engine preheat relay circuit - Voltage below normal, or shorted to low source.
             3    Fuel warmer relay circuit - Voltage above normal, or shorted to high source.
   325
             4    Fuel warmer relay circuit - Voltage below normal, or shorted to low source.
 Some error codes are not applied to this machine.
                                                  5-16
   Error code
                                                         Description
 HCESPN FMI
              3   Potentiometer (G/A) circuit - Voltage above normal, or shorted to high source.
   340
              4   Potentiometer (G/A) circuit - Voltage below normal, or shorted to low source.
              5   Governor actuator circuit - Current below normal, or open circuit.
   341
              6   Governor actuator circuit - Current above normal.
              0   Transmission oil pressure sensor data above normal range.
              1   Transmission oil pressure sensor data below normal range.
   501
              2   Transmission oil pressure sensor data error.
              4   Transmission oil pressure sensor circuit - Voltage below normal, or shorted to low source.
              0   Brake pressure sensor data above normal range.
              1   Brake pressure sensor data below normal range.
   503
              2   Brake pressure sensor data error.
              4   Brake pressure sensor circuit - Voltage below normal, or shorted to low source.
              0   Working brake pressure sensor data above normal range.
              1   Working brake pressure sensor data below normal range.
   505
              2   Working brake pressure sensor data error.
              4   Working brake pressure sensor circuit - Voltage below normal, or shorted to low source.
              3   Working brake lamp circuit - Voltage above normal, or shorted to high source.
   506
              4   Working brake lamp circuit - Voltage below normal, or shorted to low source.
              3   Ram lock lamp circuit - Voltage above normal, or shorted to high source.
   520
              4   Ram lock lamp circuit - Voltage below normal, or shorted to low source.
              5   Ram lock solenoid circuit - Current below normal, or open circuit.
   525
              6   Ram lock solenoid circuit - Current above normal.
              0   Travel F pilot pressure sensor data above normal range.
              1   Travel F pilot pressure sensor data below normal range.
   530
              2   Travel F pilot pressure sensor data error.
              4   Travel F pilot pressure sensor circuit - Voltage below normal, or shorted to low source.
              0   Travel R pilot pressure sensor data above normal range.
              1   Travel R pilot pressure sensor data below normal range.
   531
              2   Travel R pilot pressure sensor data error.
              4   Travel R pilot pressure sensor circuit - Voltage below normal, or shorted to low source.
              3   Hourmeter circuit - Voltage above normal, or shorted to high source.
   701
              4   Hourmeter circuit - Voltage below normal, or shorted to low source.
              0   MCU input voltage high.
   705
              1   MCU input voltage low.
   707        1   Alternator node I voltage low.
              3   Acc. dial circuit - Voltage above normal, or shorted to high source.
   714
              4   Acc. dial circuit - Voltage below normal, or shorted to low source.
              3   Rotate signal input circuit - Voltage above normal, or shorted to high source.
   715
              4   Rotate signal input circuit - Voltage below normal, or shorted to low source.
              3   Tilt signal input circuit - Voltage above normal, or shorted to high source.
   716
              4   Tilt signal input circuit - Voltage below normal, or shorted to low source.
              3   Travel alarm (buzzer) circuit - Voltage above normal, or shorted to high source.
   722
              4   Travel alarm (buzzer) circuit - Voltage below normal, or shorted to low source.
   830       12   MCU internal memory error.
   840        2   Cluster communication data error.
   841        2   ECM communication data error.
   843        2   Option #1 (CAN 2) communication data error.
   850        2   RCM communication data error.
 Some error codes are not applied to this machine.
                                                  5-17
4. ENGINE FAULT CODE
  Fault code
  J1939 SPN                         Reason                                 Effect (only when fault code is active)
  J1939 FMI
               Engine control module critical internal failure -      Possible no noticeable performance effects,
     111
               Bad intelligent device or component. Error             engine dying, or hard starting.
     629
               internal to the ECM related to memory hardware
      12
               failures or internal ECM voltage supply circuits.
               Engine magnetic crankshaft speed/position lost         Fueling to injectors is disabled and the engine
     115       both of two signals - Data erratic, intermittent, or   can not be started.
     612       incorrect. The ECM has detected that the primary
      2        engine speed sensor and the backup engine
               speed sensor signals are reversed.
               Intake manifold 1 pressure sensor circuit -            Engine power derate.
     122
               Voltage above normal, or shorted to high source.
     102
               High signal voltage detected at the intake
      3
               manifold pressure circuit.
               Intake manifold 1 pressure sensor circuit -            Engine power derate.
     123
               Voltage below normal, or shorted to low Source.
     102
               Low signal voltage or open circuit detected at the
      4
               intake manifold pressure circuit.
               Intake manifold 1 pressure - Data valid but above      Engine power derate.
     124
               normal operational range - Moderately severe
     102
               level. Intake manifold pressure has exceeded the
      16
               maximum limit for the given engine rating.
               Accelerator pedal or lever position sensor 1           Severe derate in power output of the engine.
     131
               circuit - Voltage above normal, or shorted to high     Limp home power only.
      91
               source. High voltage detected at accelerator
       3
               pedal position circuit.
               Accelerator pedal or lever position sensor 1           Severe derate in power output of the engine.
     132
               circuit - Voltage below normal, or shorted to low      Limp home power only.
      91
               source. Low voltage detected at accelerator
       4
               pedal position signal circuit.
               Remote accelerator pedal or lever position             Remote accelerator will not operate. Remote
     133
               sensor 1 circuit - Voltage above normal, or            accelerator position will be set to zero percent.
     974
               shorted to high source. High voltage detected at
      3
               remote accelerator pedal position circuit.
               Remote accelerator pedal or lever position             Remote accelerator will not operate. Remote
     134
               sensor 1 circuit - Voltage below normal, or            accelerator position will be set to zero percent.
     974
               shorted to low source. Low voltage detected at
      4
               remote accelerator pedal position signal circuit.
               Engine oil rifle pressure 1 sensor circuit - Voltage   None on performance. No engine protection for
     135
               above normal, or shorted to high source. High          oil pressure.
     100
               signal voltage detected at the engine oil pressure
      3
               circuit.
               Engine oil rifle pressure 1 sensor circuit - Voltage   None on performance. No engine protection for
     141
               below normal, or shorted to low source. Low            oil pressure.
     100
               signal voltage detected at engine oil pressure
      4
               circuit.
     143       Engine oil rifle pressure - Data valid but below       None on performance.
     100       normal operational range - Moderately severe
      18       level.
               Engine coolant temperature 1 sensor circuit - Possible white smoke. Fan will stay ON if
     144
               Voltage above normal, or shorted to high source. controlled by ECM. No engine protection for
     110
               High signal voltage or open circuit detected at engine coolant temperature.
      3
               engine coolant temperature circuit.
 Some fault codes are not applied to this machine.
                                                       5-18
  Fault code
  J1939 SPN                        Reason                               Effect (only when fault code is active)
  J1939 FMI
               Engine Coolant Temperature 1 Sensor Circuit -       Possible white smoke. Fan will stay ON if
     145       Voltage Below Normal, or Shorted to Low             controlled by ECM. No engine protection for
     110
               Source. Low signal voltage detected at engine       engine coolant temperature.
      4
               coolant temperature circuit.
               Engine Coolant Temperature - Data Valid but         Progressive power derate increasing in severity
     146       Above Normal Operational Range - Moderately         from time of alert.
     110       Severe Level. Engine coolant temperature signal
      16       indicates engine coolant temperature is above
               engine protection warning limit.
               Accelerator Pedal or Lever Position 1 Sensor        Severe derate in power output of the engine.
     147       Circuit Frequency - Data Valid but Below Normal     Limp home power only.
      91       Operational Range - Most Severe Level. A
       1       frequency of less than 100 Hz has been detected
               at the frequency throttle input to the ECM.
               Accelerator Pedal or Lever Position Sensor 1 -      Severe derate in power output of the engine.
     148       Data Valid but Above Normal Operational Range       Limp home power only.
      91       - Most Severe Level. A frequency of more than
      0        1500 Hz has been detected at the frequency
               throttle input to the ECM.
               Engine Coolant Temperature - Data Valid but         Progressive power derate increasing in severity
     151       Above Normal Operational Range - Most Severe        from time of aler t. If Engine Protection
     110       Level. Engine coolant temperature signal            Shutdown feature is enabled, engine will shut
      0        indicates engine coolant temperature above          down 30 seconds after Red Stop Lamp starts
               engine protection critical limit.                   flashing.
               Intake Manifold 1 Temperature Sensor Circuit -      Possible white smoke. Fan will stay ON if
     153
               Voltage Above Normal, or Shorted to High            controlled by ECM. No engine protection for
     105
      3        Source. High signal voltage detected at intake      intake manifold air temperature.
               manifold air temperature circuit.
               Intake Manifold 1 Temperature Sensor Circuit -      Possible white smoke. Fan will stay ON if
     154
               Voltage Below Normal, or Shorted to Low             controlled by ECM. No engine protection for
     105
      4        Source. Low signal voltage detected at intake       intake manifold air temperature.
               manifold air temperature circuit.
               Intake Manifold 1 Temperature - Data Valid but      Progressive power derate increasing in severity
     155       Above Normal Operational Range - Most Severe        from time of aler t. If Engine Protection
     105       Level. Intake manifold air temperature signal       Shutdown feature is enabled, engine will shut
      0        indicates intake manifold air temperature above     down 30 seconds after Red Stop Lamp starts
               engine protection critical limit.                   flashing.
     187       Sensor Supply 2 Circuit - Voltage Below Normal,     Engine power derate.
   520195      or Shorted to Low Source. Low voltage detected
      4        at the sensor supply number 2 circuit.
     195       Coolant Level Sensor 1 Circuit - Voltage Above      None on performance.
     111       Normal, or Shorted to High Source. High signal
      3        voltage detected at engine coolant level circuit.
     196       Coolant Level Sensor 1 Circuit - Voltage Below      None on performance.
     111       Normal, or Shorted to Low Source. Low signal
      4        voltage detected at engine coolant level circuit.
     197       Coolant Level - Data Valid but Below Normal         None on performance.
     111       Operational Range - Moderately Severe Level.
      18       Low coolant level has been detected.
               Barometric Pressure Sensor Circuit - Voltage        Engine power derate.
     221       Above Normal, or Shorted to High Source. High
     108
               signal voltage detected at barometric pressure
      3
               circuit.
 Some fault codes are not applied to this machine.
                                                    5-19
  Fault code
  J1939 SPN                         Reason                                Effect (only when fault code is active)
  J1939 FMI
               Barometric Pressure Sensor Circuit - Voltage Engine power derate.
     222
               Below Normal, or Shorted to Low Source. Low
     108
               signal voltage detected at barometric pressure
      4
               circuit.
     227       Sensor Supply 2 Circuit - Voltage Above Normal, Engine power derate.
   520195      or Shorted to High Source. High voltage detected
      3        at sensor supply number 2 circuit.
               Engine Crankshaft Speed/Position - Data Valid         Fuel injection disabled until engine speed falls
     234
               but Above Normal Operational Range - Most             below the overspeed limit.
     190
               Severe Level. Engine speed signal indicates
      0
               engine speed above engine protection limit.
               Coolant Level - Data Valid but Below Normal           Progressive power derate increasing in severity
     235       Operational Range - Most Severe Level. Low            from time of aler t. If Engine Protection
     111       engine coolant level detected.                        Shutdown feature is enabled, engine will shut
      1                                                              down 30 seconds after Red Stop Lamp starts
                                                                     flashing.
               External Speed Command Input (Multiple Unit
     237
               Synchronization) - Data Erratic, Intermittent, or
     644
               Incorrect. Communication between multiple
      2
               engines may be intermittent.
               Sensor Supply 3 Circuit - Voltage Below Normal,       Possible hard starting and rough running.
     238
               or Shorted to Low Source. Low voltage detected
   520196
               on the +5 volt sensor supply circuit to the engine
      4
               speed sensor.
               Wheel-based vehicle speed - Data erratic,             Engine speed limited to ,maximum engine
     241
               intermittent, or incorrect. The ECM lost the          speed without VSS parameter value. Cruise
      84
               vehicle speed signal.                                 control, gear-down protection, and road speed
       2
                                                                     governor will not work.
               Wheel-based vehicle speed sensor circuit              Engine speed limited to maximum engine
     242
               tampering has been detected - Abnormal rate of        speed without VSS parameter value. Cruise
      84
               change. Signal indicates an intermittent              control, gear-down protection, and road speed
      10
               connection or VSS tampering.                          g+H53overnor will not work.
               Fan control circuit - Voltage below normal, or        The fan may stay on continuously or not run at
     245
               shorted to low source. Low signal voltage             all.
     647
               detected at the fan control circuit when
      4
               commanded on.
     268       Injector metering rail 1 pressure - data erratic, The ECM will estimate fuel pressure, and power
      94       intermittent, or incorrect. The ECM has detected is reduced.
      2        that the fuel pressure signal is not changing.
               Fuel pump pressurizing assembly 1 circuit -           Engine will run poorly at idle. Engine will have
     271
               Voltage below normal, or shorted to low source.       low power. Fuel pressure will be higher than
    1347
               Low signal voltage detected at the fuel pump          commanded.
      4
               actuator circuit.
               Fuel pump pressurizing assembly 1 circuit -           Engine will not run or engine will run poorly.
     272
               Voltage above normal, or shorted to high source.
    1347
               High signal voltage or open circuit detected at the
      3
               fuel pump actuator circuit.
     275       Fuel pumping element number 1 (front) -               Engine will not run or possible low power.
    1347       Mechanical system not responding properly or
      7        out of adjustment.
     281       Fuel pump pressurizing assembly 1 - Mechanical Engine will not run or possible low power.
    1347       system not responding properly or out of
      7        adjustment.
               SAE J1939 multiplexing PGN timeout error - At least one multiplexed device will not operate
     285
               Abnormal update rate. The ECM expected properly.
     639
               information from a multiplexed device but did not
      9
               receive it soon enough or did not receive it at all.
 Some fault codes are not applied to this machine.
                                                      5-20
  Fault code
  J1939 SPN                         Reason                                Effect (only when fault code is active)
  J1939 FMI
               SAE J1939 multiplexing configuration error -          At least one multiplexed device will not operate
     286
               Out of calibration. The ECM expected                  properly.
     639
               information from a multiplexed device but only
     13
               received a portion of the necessary information.
               SAE J1939 multiplexed accelerator pedal or lever      Engine may only idle or engine will not
     287
               sensor system - received network data In error.       accelerate to full speed.
      91
               The OEM vehicle electronic control unit (VECM)
      19
               detected a fault with its accelerator pedal.
               SAE J1939 Multiplexing Remote Accelerator             The engine will not respond to the remote
     288       Pedal or Lever Position Sensor Circuit - Received     throttle. Engine may only idle. The primary or
     974       Network Data In Error. The OEM vehicle                cab accelerator may be able to be used.
      19       electronic control unit (VECU) detected a fault
               with the remote accelerator.
     292       Auxiliary temperature Sensor Input 1 - Special        Possible engine power derate.
     441       instructions.
      14
               Auxiliary temperature sensor input 1 circuit - None on performance.
     293
               Voltage above normal, or shorted to high source.
     441
               High signal voltage or open circuit detected at
      3
               the OEM auxiliary temperature circuit.
               Auxiliary temperature sensor input 1 circuit - None on performance.
     294
               Voltage below normal, or shorted to low source.
     441
               Low signal voltage detected at the OEM auxiliary
      4
               temperature circuit.
     296       Auxiliary pressure sensor input 1 - Special Possible engine power derate.
    1388       instructions.
      14
               Auxiliary pressure sensor input 1 circuit - Voltage   None on performance.
     297
               above normal, or shorted to high source. High
    1388
               signal voltage detected at the OEM pressure
      3
               circuit.
               Auxiliary pressure sensor input 1 circuit - Voltage   None on performance.
     298
               below normal, or shorted to low source. Low
    1388
               signal voltage or open circuit detected at the
      4
               OEM pressure circuit.
     319       Real time clock power interrupt - Data erratic,       None on performance. Data in the ECM will not
     251       intermittent, or incorrect. Real time clock lost      have accurate time and date information.
      2        power.
               Injector solenoid driver cylinder 1 circuit - Current Engine can possibly misfire or run rough.
               below normal, or open circuit. High resistance
     322
               detected on injector number 1 circuit or no
     651
               current detected at number 1 injector driver or
      5
               return pin when the voltage supply at the
               harness is on.
               Injector solenoid driver cylinder 5 circuit - Current Engine can possibly misfire or run rough.
               below normal, or open circuit. High resistance
     323
               detected on injector number 5 circuit or no
     655
               current detected at number 5 injector driver or
      5
               return pin when the voltage supply at the
               harness is on.
               Injector solenoid driver cylinder 3 circuit - Current Engine can possibly misfire or run rough.
               below normal, or open circuit. High resistance
     324
               detected on injector number 3 circuit or no
     653
               current detected at number 3 injector driver or
      5
               return pin when the voltage supply at the
               harness is on.
 Some fault codes are not applied to this machine.
                                                      5-21
  Fault code
  J1939 SPN                          Reason                                 Effect (only when fault code is active)
  J1939 FMI
               Injector solenoid driver cylinder 6 circuit - Current   Engine can possibly misfire or run rough.
               below normal, or open circuit. High resistance
     325
               detected on injector number 6 circuit or no
     656
               current detected at number 6 injector driver or
      5
               return pin when the voltage supply at the
               harness is on.
               Injector solenoid driver cylinder 2 circuit - Current   Engine can possibly misfire or run rough.
               below normal, or open circuit. High resistance
     331
               detected on injector number 2 circuit or no
     652
               current detected at number 2 injector driver or
      5
               return pin when the voltage supply at the
               harness is on.
               Injector solenoid driver cylinder 4 circuit - Current   Engine can possibly misfire or run rough.
               below normal, or open circuit. High resistance
     332
               detected on injector number 4 circuit or no
     654
               current detected at number 4 injector driver or
      5
               return pin when the voltage supply at the
               harness is on.
               Engine coolant temperature - Data erratic,              The ECM will estimate engine coolant
     334
               intermittent, or incorrect. The engine coolant          temperature.
     110
               temperature reading is not changing with engine
      2
               operating conditions.
     342       Electronic calibration code incompatibility - Out of    Possible no noticeable performance effects,
     630       calibration. An incompatible calibration has been       engine dying, or hard starting.
      13       detected in the ECM.
     343       Engine control module warning internal hardware No performance effects or possible severe
     629       failure - Bad intelligent device or component. power derate.
      12       Internal ECM failure.
     351       Injector power supply - Bad intelligent device or Possible smoke, low power, engine misfire,
     627       component. The ECM measured injector boost and/or engine will not start.
      12       voltage is low.
      352      Sensor supply 1 circuit - Voltage below normal, Engine power derate.
     1079      or shorted to low source. Low voltage detected at
       4       sensor supply number 1 circuit.
      386      Sensor supply 1 circuit - Voltage above normal, Engine power derate.
     1079      or shorted to high source. High voltage detected
       3       at sensor supply number 1 circuit.
               Engine oil rifle pressure - Data valid but below
                                                              Progressive power derate increasing in severity
     415       normal operational range - Most severe level. Oil
                                                              from time of aler t. If engine protection
     100       pressure signal indicates oil pressure below the
                                                              shutdown feature is enabled, engine will shut
      1        engine protection critical limit.              down 30 seconds after red stop lamp starts
                                                              flashing.
     418       Water in fuel indicator - Data valid but above Possible white smoke, loss of power, or hard
      97       normal operational range - Least severe level. starting.
      15       water has been detected in the fuel filter.
     428       Water in fuel indicator sensor circuit - Voltage None on performance. No water in fuel warning
      97       above normal, or shorted to high source. High available.
      3        voltage detected at the water in fuel circuit.
     429       Water in fuel indicator sensor circuit - Voltage None on performance. No water in fuel warning
      97       below normal, or shorted to low source. Low available.
       4       voltage detected at the water in fuel circuit.
               Accelerator pedal or lever idle validation switch - Engine will only idle.
     431
               Data erratic, intermittent, or incorrect. Voltage
     558
               detected simultaneously on both idle validation
      2
               and off-idle validation switches.
 Some fault codes are not applied to this machine.
                                                        5-22
  Fault code
  J1939 SPN                          Reason                                  Effect (only when fault code is active)
  J1939 FMI
               Accelerator pedal or lever idle validation circuit -     Engine will only idle.
     432       Out of calibration. Voltage at idle validation
     558
               on-idle and off-idle circuit does not match
      13
               accelerator pedal position.
     435       Engine oil rifle pressure - Data erratic,                None on performance. No engine protection for
     100       intermittent, or incorrect. An error in the engine oil   oil pressure.
      2        pressure switch signal was detected by the ECM.
               Battery 1 voltage - Data valid but below normal          Engine may stop running or be difficult to start.
     441       operational range - Moderately severe level.
     168
               ECM supply voltage is below the minimum
      18
               system voltage level.
               Battery 1 Voltage - Data valid but above normal          Possible electrical damage to all electrical
     442       operational range - Moderately severe level.             components.
     168
               ECM supply voltage is above the maximum
      16
               system voltage level.
     449       Injector metering rail 1 pressure - Data valid but       None or possible engine noise associated with
     157       above normal operational range - Most severe             higher injection pressures (especially at idle or
      0        level.                                                   light load). Engine power is reduced.
               Injector metering rail 1 pressure sensor circuit -       Power and or speed derate.
     451       Voltage above normal, or shorted to high source.
     157
               High signal voltage detected at the rail fuel
      3
               pressure sensor circuit.
               Injector metering rail 1 pressure sensor circuit -       Power and or speed derate.
     452
               Voltage below normal, or shorted to low source.
     157
               Low signal voltage detected at the rail fuel
      4
               pressure sensor circuit.
               Intake manifold 1 temperature - Data valid but           Progressive power derate increasing in severity
     488       above normal operational range - Moderately              from time of alert.
     105       severe level. Intake manifold air temperature
      16       signal indicates intake manifold air temperature
               is above the engine protection warning limit.
      497      Multiple unit synchronization switch - Data              None on performance.
     1377      erratic, intermittent, or incorrect.
       2
     523       Auxiliary intermediate (PTO) speed switch None on performance.
     611       validation - Data erratic, intermittent, or
      2        incorrect.
               Auxiliary input/output 2 circuit - Voltage above None on performance.
     527
               normal, or shorted to high source. High signal
     702
               voltage or open circuit has been detected at the
      3
               auxiliary input/output 2 circuit.
     528       Auxiliary alternate torque validation switch - None on performance.
      93       Data erratic, intermittent, or incorrect.
       2
               Auxiliary input/output 3 circuit - Voltage above Engine will only idle.
     529       normal, or shorted to high source. Low signal
     703
               voltage has been detected at the auxiliary input/
      3
               output 2 circuit.
               Injector metering rail 1 pressure - Data valid but Possibly hard to start, low power, or engine
     553       above normal operational range - Moderately smoke.
     157
               severe level. The ECM has detected that fuel
      16
               pressure is higher than commanded pressure.
 Some fault codes are not applied to this machine.
                                                        5-23
  Fault code
  J1939 SPN                        Reason                                Effect (only when fault code is active)
  J1939 FMI
     554       Injector metering rail 1 pressure - Data erratic,    Either the engine will not start or the engine will
     157       Intermittent, or incorrect. The ECM has detected     not have starter lockout protection.
      2        that the fuel pressure signal is not changing.
               Injector metering rail 1 pressure - Data Valid but   The engine will not have starter lockout
     559       Below Normal Operational Range - Moderately          protection.
     157
               Severe Level. The ECM has detected that fuel
      18
               pressure is lower than commanded pressure.
               Starter relay driver circuit - Voltage above         Engine power derate. The ECM uses an
     584       normal, or shorted to high source. Open circuit      estimated turbocharger speed.
     677
               or high voltage detected at starter lockout
      3
               circuit.
     585       Starter relay driver circuit - Voltage below         Amber lamp will light until high battery voltage
     677       normal, or shorted to low source. Low voltage        condition is corrected.
      4        detected at starter lockout circuit.
               Turbocharger 1 speed - Data valid but above          Amber lamp will light until high battery voltage
     595       normal operational range - Moderately severe         condition is corrected.
     103
               level. High turbocharger speed has been
      16
               detected.
     599       Auxiliary commanded dual output shutdown -        None or possible engine noise associated with
     640       Special instructions.                             higher injection pressures (especially at idle or
      14                                                         light load). Engine power is reduced.
               Turbocharger 1 speed - Data valid but below Engine power derate.
     687       normal operational range - Moderately severe
     103
               level. Low turbocharger speed detected by the
      18
               ECM.
     689       Engine crankshaft speed/position - Data erratic, Engine power derate.
     190       intermittent, or incorrect. Loss of signal from
      2        crankshaft sensor.
               Turbocharger 1 compressor inlet temperature Engine will run derated. Excessive black
     691       circuit - Voltage above normal, or shorted to smoke, hard start, and rough idle possible.
    1172       high source. High signal voltage detected at
      3        turbocharger compressor inlet air temperature
               circuit.
               Turbocharger 1 compressor inlet temperature Possible no noticeable performance effects,
     692
               circuit - Voltage below normal, or shorted to low engine dying, or hard starting.
    1172
      4        source. Low signal voltage detected at
               turbocharger compressor inlet air tempera
               Engine speed / position camshaft and Possible poor starting. Engine power derate.
     731       crankshaft misalignment - Mechanical system
     723       not responding properly or out of adjustment.
      7        mechanical misalignment between the
               crankshaft and camshaft engine speed sensors.
     757       Electronic control module data lost - Condition Possible poor starting. Engine power derate.
     611       exists. Severe loss of data from the ECM.
      31
               Engine camshaft speed / position sensor - Data       Possible no noticeable performance effects or
     778
               erratic, intermittent, or incorrect. The ECM has     engine dying or hard starting. Fault information,
     723
               detected an error in the camshaft position           trip information, and maintenance monitor data
      2
               sensor signal.                                       may be inaccurate.
     779       Auxiliary equipment sensor input 3 - Root            Engine will shut down.
     703       cause not known.
      11
 Some fault codes are not applied to this machine.
                                                     5-24
  Fault code
  J1939 SPN                         Reason                                Effect (only when fault code is active)
  J1939 FMI
               Power supply lost with ignition on - Data erratic, Engine will shut down.
               intermittent, or incorrect. Supply voltage to the
     1117      ECM fell below 6.2 volts momentarily, or the
      627
               ECM was not allowed to power down correctly
       2
               (retain battery voltage for 30 seconds after key
               OFF).
               OEM datalink cannot transmit - Data erratic, Engine will only idle.
     1633      intermittent, or incorrect. Communications within
      625
               the OEM datalink network is intermittent.
       2
               Sensor supply 4 circuit - Voltage above normal,       Possibly hard to start, low power, or engine
    2185       or shorted to high source. High voltage detected      smoke.
   520197
               at +5 volt sensor supply circuit to the accelerator
     3
               pedal position sensor.
               Sensor supply 4 circuit - Voltage below normal,       None or possible engine noise associated with
    2186       or shorted to low source. Low voltage detected        higher injection pressure (especially at idle or
   520197
               at +5 volt sensor supply circuit to the accelerator   light load)
     4
               pedal position sensor.
               Injector metering rail 1 pressure - Data valid but    Engine may be difficult to start.
     2249
               below normal operational range - Most severe
      157
               level. The ECM has detected that fuel pressure
       1
               is lower than commanded pressure.
               Electric lift pump for engine fuel supply circuit -   Possible low power.
     2265
               Voltage above normal, or shorted to high
     1075
               source. High voltage or open detected at the
       3
               fuel lift pump signal circuit.
               Electric lift pump for engine fuel supply circuit -   Engine may exhibit misfire as control switches
     2266
               Voltage below normal, or shorted to low source.       from the primary to the backup speed sensor.
     1075
       4       Low signal voltage detected at the fuel lift pump     Engine power is reduced while the engine
               circuit.                                              operates on the backup speed sensor.
     2311      Electronic fuel injection control valve circuit -     Possible low power.
      633      Condition exists. Fuel pump actuator circuit
       31      resistance too high or too low.
     2321      Engine crankshaft speed/position - Data erratic,      Engine power derate.
      190      intermittent, or incorrect. crankshaft engine
       2       speed sensor intermittent synchronization.
               Engine camshaft speed / position sensor - Data        Engine power derate.
     2322
               erratic, intermittent, or incorrect. Camshaft
      723
       2       engine speed sensor intermittent
               synchronization.
     2345      Turbocharger 1 Speed - Abnormal rate of               Engine power derate.
      103      change. The turbocharger speed sensor has
      10       detected an erroneous speed value.
               Turbocharger turbine inlet temperature                Engine brake on cylinders 1, 2, and 3 can not
     2346      (Calculated) - Data valid but above normal            be activated or exhaust brake will not operate.
     2789      operational range - Least severe level.
      15       Turbocharger turbine inlet temperature has
               exceeded the engine protection limit.
     2347      Turbocharger compressor outlet temperature            Engine brake on cylinders 4, 5 and 6 can not
     2790      (Calculated) - Data valid but above normal            be activated or exhaust brake will not operate.
      15       operational range - Least severe level.
     2377      Fan control circuit - Voltage above normal, or        Variable geometry turbocharger will go to the
      647      shorted to high source. Open circuit or high          open position.
       3       voltage detected at the fan control circuit.
 Some fault codes are not applied to this machine.
                                                      5-25
  Fault code
  J1939 SPN                        Reason                               Effect (only when fault code is active)
  J1939 FMI
     2384      VGT actuator driver circuit - Voltage below         The intake air heaters may be ON or OFF all
      641      normal, or shorted to low source. Low voltage       the time.
       4       detected at turbocharger control valve circuit.
               VGT actuator driver circuit - Voltage above         The intake air heaters may be ON or OFF all
     2385      normal, or shorted to high source. Open circuit     the time.
      641
               or high voltage detected at turbocharger control
       3
               valve circuit.
     2555      Intake air heater 1 circuit - Voltage above         Can not control transmission.
      729      normal, or shorted to high source. High voltage
       3       detected at the intake air heater signal circuit.
     2556      Intake air heater 1 circuit - Voltage below         Can not control transmission.
      729      normal, or shorted to low source. Low voltage
       4       detected at the intake air heater signal circuit.
     2557      Auxiliary PWM driver 1 circuit - Voltage above      Power derate and possible engine shutdown if
      697      normal, or shorted to high source. High signal      engine protection shutdown feature is enabled.
       3       voltage detected at the analog torque circuit.
     2558      Auxiliary PWM driver 1 circuit - Voltage below      Pregressive power derate increasing in severity
      697      normal, or shorted to low source. Low signal        from time of alert.
       4       voltage detected at the analog torque circuit.
               Intake manifold 1 pressure - Data erratic,
     2973      intermittent, or incorrect. The ECM has detected
      102      an intake manifold pressure signal that is too
       2       high or low for current engine operating
               conditions.
 Some fault codes are not applied to this machine.
5-26