Technical Data
1756 ControlLogix Power Supplies Specifications
Standard Power Supplies Catalog Numbers 1756-PA72, 1756-PA75, 1756-PB72, 1756-PB75, 1756-PC75, 1756-PH75
Standard Slim Power Supplies Catalog Numbers 1756-PA50, 1756-PB50
ControlLogix-XT Power Supplies Catalog Numbers 1756-PAXT, 1756-PBXT
ControlLogix-XT Slim Power Supplies Catalog Numbers 1756-PA30XT, 1756-PB30XT
Redundant Power Supplies Catalog Numbers 1756-PA75R, 1756-PB75R
Redundant Power Supplies Chassis Adapter Catalog Number 1756-PSCA2
ControlLogix-XT Redundant Power Supplies Catalog Numbers 1756-PAXTR, 1756-PBXTR
ControlLogix-XT Redundant Power Supplies Chassis Adapter Catalog Number 1756-PSCA2XT
Redundant Power Supply Power Cable Catalog Numbers 1756-CPR2, 1756-CPR2D, 1756-CPR2U
Topic Page
Standard AC Power Supplies 2
Standard DC Power Supplies 2
1756 ControlLogix-XT Power Supplies 8
Redundant Power Supplies 11
Power Load and Transformer Sizing 18
Additional Resources 21
ControlLogix power supplies are used with the 1756 chassis to provide 1.2V, 3.3V, 5V, and 24V DC power directly to
the chassis backplane. Standard, Slim, ControlLogix-XT, and redundant power supplies are available.
Summary of Changes
This manual contains changes to the 1756-PBXT ControlLogix-XT power supply and 1756-PBXTR ControlLogix-XT
redundant power supply technical specifications.
1756 ControlLogix Power Supplies Specifications
Standard AC Power Supplies
Mounting Dimensions
1756-PA72 and 1756-PA75 1756-PA50
14.0 14.0
(5.51) (5.51)
11.2
7.8
(4.41)
(3.07)
Dimensions are in cm (in.).
Technical Specifications - Standard AC Power Supplies
Attribute 1756-PA50 1756-PA72/C 1756-PA75/B
Input voltage range(1) 85265V AC
Input voltage, nom 120V/240V AC
Input frequency range 4763 Hz
Input power, max 81 W/91VA @ 50 C (122 F) 100VA/100 W
68 W/77VA @ 60 C (140 F)
Output power, max 60 W @ 0+50 C (+32+122 F)(3) 75 W @ 0+60 C (+32+140 F)(6)
50 W @ 0+60 C (+32+140 F)(4)
Inrush current, max 20 A
Hold up time(2) 4 cycles @85...265V AC, 50/60 Hz, 60 W 5 cycles @ 85V AC, 50/60 Hz 2 cycles @ 85V AC, 60 Hz
5 cycles @85...265V AC, 50/60 Hz, 50 W 6 cycles @ 120V AC, 50/60 Hz 6 cycles @ 120V AC, 60 Hz
6 cycles @ 200V AC, 50/60 Hz 20 cycles @ 220V AC, 60 Hz
6 cycles @ 240V AC, 50/60 Hz
Current capacity @ 1.2V DC 1.5 A
Current capacity @ 3.3V DC 2A 4A
Current capacity @ 5.1V DC 8 A @ 50 C (122 F) 10 A 13 A
6 A @ 60 C (140 F)
Current capacity @ 24V DC 2.5 A @ 50 C (122 F) 2.8 A
2.0 A @ 60 C (140 F)
Isolation voltage 250V (continuous), Reinforced Insulation 250V (continuous), Reinforced Insulation Type, Power Input to Backplane
Type, Power Input to Backplane Type tested at 3500V DC for 60 s
Type tested @ 3150V DC for 60 s
Weight, approx 0.77 kg (1.7 lb) 0.95 kg (2.10 lb)
Dimensions (HxWxD), approx 14.0 x 7.8 x 14.5 cm 14.0 x 11.2 x 14.5 cm (5.51 x 4.41 x 5.71 in.)
(5.51 x 3.07 x 5.71 in.)
Module location Left side of 1756 chassis
Chassis 1756-A4, 1756-A7, 1756-A10, 1756-A13, 1756-A17
Chassis compatibility Series A Series B
Series B Series C
Series C
Wire size 2.5 mm2 (14 AWG) solid or stranded copper wire rated at 90 C (194 F), or greater, 1.2 mm (3/64 in.) insulation max
2 Rockwell Automation Publication 1756-TD005G-EN-E - June 2017
1756 ControlLogix Power Supplies Specifications
Technical Specifications - Standard AC Power Supplies
Attribute 1756-PA50 1756-PA72/C 1756-PA75/B
Wire category 1 - on power ports(5)
Conductor screw torque 0.8 Nm (7 lbin)
North American temperature code T4
Enclosure type rating None (open-style)
(1) UL certification for 120/240V AC, 50/60 Hz nominal. Rockwell Automation specified 85265V AC, 4763 Hz.
(2) The hold up time is the time between input voltage removal and DC power failure.
(3) The combination of all output power (5.1V backplane, 24V backplane, 3.3V backplane, and 1.2V backplane) cannot exceed 60 W @ 50 C (122 F) maximum temperature.
(4) The combination of all output power (5.1V backplane, 24V backplane, 3.3V backplane, and 1.2V backplane) cannot exceed 50 W @ 60 C (140 F) maximum temperature.
(5) Use this conductor category information to plan conductor routing as described in the system level installation manual. See the Industrial Automation Wiring and Grounding Guidelines,
publication 1770-4.1.
(6) The combination of all output power (5.1V backplane, 24V backplane, 3.3V backplane, and 1.2V backplane) cannot exceed 75 W.
Environmental Specifications - Standard AC Power Supplies
Attribute 1756-PA50 1756-PA72/C, 1756-PA75/B
Temperature, operating 0 C < Ta < +60 C (+32 F < Ta < +140 F)
IEC 60068-2-1 (Test Ad, Operating Cold),
IEC 60068-2-2 (Test Bd, Operating Dry Heat),
IEC 60068-2-14 (Test Nb, Operating Thermal Shock)
Temperature, surrounding air, max 60 C (140 F)
Temperature, non-operating -40+85 C (-40+185 F)
IEC 60068-2-1 (Test Ab, Unpackaged Nonoperating Cold),
IEC 60068-2-2 (Test Bb, Unpackaged Nonoperating Dry Heat),
IEC 60068-2-14 (Test Na, Unpackaged Nonoperating Thermal
Shock)
Relative humidity 595% noncondensing
IEC 60068-2-30 (Test Db, Unpackaged Damp Heat)
Vibration 2 g @ 10500 Hz
IEC 60068-2-6 (Test Fc, Operating)
Shock, operating 30 g
IEC 60068-2-27 (Test Ea, Unpackaged Shock)
Shock, nonoperating 50 g(1)
IEC 60068-2-27 (Test Ea, Unpackaged Shock)
Emissions IEC 61000-6-4
ESD immunity 6 kV contact discharges
IEC 61000-4-2 8 kV air discharges
Radiated RF immunity 10V/m with 1 kHz sine-wave 80% AM from 802000 MHz
IEC 61000-4-3 10V/m with 200 Hz 50% Pulse 100% AM @ 900 MHz
10V/m with 200 Hz 50% Pulse 100% AM @ 1890 MHz
3V/m with 1kHz sine-wave 80% AM from 20002700 MHz
EFT/B immunity 4 kV at 5 kHz on power ports
IEC 61000-4-4
Surge transient immunity 1 kV line-line (DM) and 2 kV line-earth (CM) on power ports
IEC 61000-4-5
Conducted RF immunity 10V rms with 1 kHz sine-wave 80% AM from 150 kHz80 MHz
IEC 61000-4-6
Voltage variation 30% dips for 1 period at 0 and 180 on AC supply ports
IEC 61000-4-11 60% dips for 5 and 50 periods on AC supply ports
10% fluctuations for 15 min on AC supply ports
>95% interruptions for 250 periods on AC supply ports
Damped oscillatory wave immunity 2.5 kV line-line (DM) and 2.5 kV line-earth (CM) on power
IEC 61000-4-18 ports
(1) Series C chassis have a maximum nonoperating shock value of 30 g. If you select a Series C chassis for use with your power supply, you are limited to a maximum nonoperating shock value of 30 g.
Rockwell Automation Publication 1756-TD005G-EN-E - June 2017 3
1756 ControlLogix Power Supplies Specifications
Certifications - Standard AC Power Supplies
Certification(1) 1756-PA50 1756-PA72/C 1756-PA75/B
UL UL Listed Industrial Control Equipment. See UL File E65584.
c-UL-us UL Listed Industrial Control Equipment, certified for US
and Canada. See UL File E65584.
UL Listed for Class I, Division 2 Group A,B,C,D Hazardous
Locations, certified for U.S. and Canada. See UL File
E194810.
CSA CSA Certified Process Control Equipment. See CSA File LR54689C.
CSA Certified Process Control Equipment for Class I, Division 2 Group A,B,C,D Hazardous Locations. See CSA File
LR69960C.
FM FM Approved Equipment for use in Class I Division 2 Group A,B,C,D Hazardous Locations
CE European Union 2014/30/EU EMC Directive, compliant European Union 2014/30/EU EMC Directive, compliant with:
with: EN 61326-1; Meas./Control/Lab., Industrial Requirements
EN 61326-1; Meas./Control/Lab., Industrial EN 61000-6-2; Industrial Immunity
Requirements EN 61000-6-4; Industrial Emissions
EN 61000-6-2; Industrial Immunity EN 61131-2; Programmable Controllers (Clause 8, Zone A & B)
EN 61000-6-4; Industrial Emissions European Union 2014/35/EU LVD, compliant with:
EN 61131-2; Programmable Controllers (Clause 8, Zone EN 61131-2; Programmable Controllers (Clause 11)
A & B)
European Union 2014/35/EU LVD, compliant with:
EN 61010-2-201; Control Equipment Safety
Requirements
RCM Australian Radiocommunications Act, compliant with:
EN 61000-6-4; Industrial Emissions
KC Korean Registration of Broadcasting and Communications Equipment, compliant with:
Article 58-2 of Radio Waves Act, Clause 3
EAC Russian Customs Union TR CU 020/2011 EMC Technical Regulation
Russian Customs Union TR CU 004/2011 LV Technical Regulation
(1) See the Product Certification link at http://www.ab.com for Declarations of Conformity, Certificates, and other certification details.
4 Rockwell Automation Publication 1756-TD005G-EN-E - June 2017
1756 ControlLogix Power Supplies Specifications
Standard DC Power Supplies
Mounting Dimensions
1756-PB72, 1756-PB75,
1756-PC75, and 1756-PH75 1756-PB50
14.0 14.0
(5.51) (5.51)
11.2
7.8
(4.41)
(3.07)
Dimensions are in cm (in.).
Technical Specifications - Standard DC Power Supplies
Attribute 1756-PB50 1756-PB72/C 1756-PB75/B 1756-PC75/B 1756-PH75/B
Input voltage range 1832V DC(2) 3060V DC(5) 90143V DC(6)
Input voltage, nom 24V DC 48V DC 125V DC
Input power, max 85 W @ 50 C (122 F) 95 W
70 W @ 60 C (140 F)
Output power, max 60 W @ 050 C 75 W @ 060 C (32140 F)(4)
(32122 F)
50 W @ 060 C
(32140 F)
Inrush current, max 30 A
(1)
Hold up time 30 ms @18...32V DC, 35 ms @ 18V DC 50 ms @ 3060V DC 50 ms @ 90143V DC
60 W 40 ms @ 24V DC nom nom
40 ms @18...32V DC, 40 ms @ 32V DC
50 W
Current capacity @ 1.2V 1.5 A
Current capacity @ 3.3V 2A 4A
Current capacity @ 5.1V 8 A @ 50 C (122 F) 10 A 13 A
6 A @ 60 C (140 F)
Current capacity @ 24V 2.5 A @ 50 C (122 F) 2.8 A
2.0 A @ 60 C (140 F)
Isolation voltage 250V (continuous), 250V (continuous), Reinforced Insulation Type, Power Input to Backplane
Reinforced Insulation Type tested @ 3500V DC for 60 s
Type, Power Input to
Backplane
Type tested @
3150V DC for 60 s
Weight, approx 0.77 kg (1.7 lb) 0.95 kg (2.10 lb)
Dimensions (HxWxD), approx 14.0 x 7.8 x 14.5 cm 14.0 x 11.2 x 14.5 cm (5.51 x 4.41 x 5.71 in.)
(5.51 x 3.07 x 5.71 in.)
Module location Left side of 1756 chassis
Chassis 1756-A4, 1756-A7, 1756-A10, 1756-A13, 1756-A17
Rockwell Automation Publication 1756-TD005G-EN-E - June 2017 5
1756 ControlLogix Power Supplies Specifications
Technical Specifications - Standard DC Power Supplies
Attribute 1756-PB50 1756-PB72/C 1756-PB75/B 1756-PC75/B 1756-PH75/B
Chassis compatibility Series A Series B
Series B Series C
Series C
Wire size 2.5 mm2 (14 AWG) solid or stranded copper wire rated at 90 C (194 F), or greater, 1.2 mm (3/64 in.) insulation max
Wire category 1 - on power ports(3)
Conductor screw torque 0.8 Nm (7 lbin)
North American temperature code T4
ATEX temperature code T4
IEC temperature code T4
Enclosure type rating None (open-style)
(1) The hold up time is the time between input voltage removal and DC power failure.
(2) UL certification for 24V DC nominal. Rockwell Automation specified 1832V DC.
(3) Use this conductor category information to plan conductor routing as described in the system level installation manual. See the Industrial Automation Wiring and Grounding Guidelines, publication 1770-4.1.
(4) The combination of all output power (5.1V backplane, 24V backplane, 3.3V backplane, and 1.2V backplane) cannot exceed 75 W.
(5) UL Certification for 48V DC nominal. Rockwell Automation specified 3060V DC.
(6) UL certification for 125V DC nominal. Rockwell Automation specified 90143V DC.
Environmental Specifications - Standard DC Power Supplies
Attribute 1756-PB50 1756-PB72/C, 1756-PB75/B 1756-PC75/B, 1756-PH75/B
Temperature, operating 0 C < Ta < +60 C (+32 F < Ta < +140 F)
IEC 60068-2-1 (Test Ad, Operating Cold),
IEC 60068-2-2 (Test Bd, Operating Dry Heat),
IEC 60068-2-14 (Test Nb, Operating Thermal
Shock)
Temperature, surrounding air, max 60 C (140 F)
Temperature, nonoperating -40+85 C (-40+185 F)
IEC 60068-2-1 (Test Ab, Unpackaged
Nonoperating Cold),
IEC 60068-2-2 (Test Bb, Unpackaged
Nonoperating Dry Heat),
IEC 60068-2-14 (Test Na, Unpackaged
Nonoperating Thermal Shock)
Relative humidity 595% noncondensing
IEC 60068-2-30
(Test Db, Unpackaged Damp Heat)
Vibration 2 g @ 10500 Hz
IEC 60068-2-6 (Test Fc, Operating)
Shock, operating 30 g
IEC 60068-2-27 (Test Ea, Unpackaged Shock)
Shock, nonoperating 50 g(1)
IEC 60068-2-27 (Test Ea, Unpackaged Shock)
Emissions IEC 61000-6-4
ESD immunity 6 kV contact discharges
IEC 61000-4-2 8 kV air discharges
Radiated RF immunity 10V/m with 1 kHz sine-wave 80% AM from 802000 MHz
IEC 61000-4-3 10V/m with 200 Hz 50% Pulse 100% AM @ 900 MHz
10V/m with 200 Hz 50% Pulse 100% AM @ 1890 MHz
3V/m with 1 kHz sine-wave 80% AM from 20002700 MHz
EFT/B immunity 4 kV at 5 kHz on power ports
IEC 61000-4-4
6 Rockwell Automation Publication 1756-TD005G-EN-E - June 2017
1756 ControlLogix Power Supplies Specifications
Environmental Specifications - Standard DC Power Supplies
Attribute 1756-PB50 1756-PB72/C, 1756-PB75/B 1756-PC75/B, 1756-PH75/B
Surge transient immunity 1 kV line-line (DM) and 2 kV line-earth (CM) on power ports
IEC 61000-4-5
Conducted RF immunity 10V rms with 1 kHz sine-wave 80% AM from 150 kHz80 MHz
IEC 61000-4-6
Voltage variation 10 ms interruption on DC supply ports(2)
IEC 61000-4-29 60% dips for 100 ms on DC supply ports
100% dips for 50 ms on DC supply ports
20% fluctuations for 15 min on DC supply ports
5 s interruptions on DC supply ports(3)
(1) Series C chassis have a maximum nonoperating shock value of 30 g. If you select a Series C chassis for use with your power supply, you are limited to a maximum nonoperating shock value of 30 g.
(2) Short interruption test verifies ride through. The supply remains fully functional under this condition.
(3) Long interruption test verifies that repetitive inrush surge currents do not create any unsafe conditions. The supply fully shuts down and starts up in this test.
Certifications - Standard DC Power Supplies
Certification(1) 1756-PB50 1756-PB72/C, 1756-PB75/B 1756-PC75/B, 1756-PH75/B
UL UL Listed Industrial Control Equipment. See UL File
E65584.
c-UL-us UL Listed Industrial Control Equipment, certified for US and Canada. See UL File E65584.
UL Listed for Class I, Division 2 Group A,B,C,D Hazardous Locations, certified for US and Canada. See UL File E194810.
CSA CSA Certified Process Control Equipment. See CSA File LR54689C.
CSA Certified Process Control Equipment for Class I, Division 2 Group A,B,C,D Hazardous Locations. See CSA File
LR69960C.
FM FM Approved Equipment for use in Class I Division 2 Group A,B,C,D Hazardous Locations
CE European Union 2014/30/EU EMC Directive, compliant European Union 2014/30/EU EMC Directive, compliant with:
with: EN 61326-1; Meas./Control/Lab., Industrial Requirements
EN 61326-1; Meas./Control/Lab., Industrial EN 61000-6-2; Industrial Immunity
Requirements EN 61000-6-4; Industrial Emissions
EN 61000-6-2; Industrial Immunity EN 61131-2; Programmable Controllers (Clause 8, Zone A & B)
EN 61131-2; Programmable Controllers (Clause 8, Zone European Union 2014/35/EU LVD, compliant with:
A & B) EN 61131-2; Programmable Controllers (Clause 11)
EN 61000-6-4; Industrial Emissions
European Union 2014/35/EU LVD, compliant with:
EN 61010-2-201; Control Equipment Safety
Requirements
RCM Australian Radiocommunications Act, compliant with:
EN 61000-6-4; Industrial Emissions
Ex European Union 2014/34/EU ATEX Directive, compliant with:
EN 60079-0; General Requirements
EN 60079-15; Potentially Explosive Atmospheres, Protection "n"
II 3 G Ex nA IIC T4 Gc
DEMKO13ATEX1325026X
IECEx IECEx System, compliant with:
IEC 60079-0; General Requirements
IEC 60079-15; Potentially Explosive Atmospheres, Protection "n"
II 3 G Ex nA IIC T4 Gc
IECEx UL 14.0008X
KC Korean Registration of Broadcasting and Communications Equipment, compliant with:
Article 58-2 of Radio Waves Act, Clause 3
EAC Russian Customs Union TR CU 020/2011 EMC Technical Regulation
Russian Customs Union TR CU 004/2011 LV Technical Regulation
(1) When marked. See the Product Certification link at http://www.ab.com for Declarations of Conformity, Certificates, and other certification details.
Rockwell Automation Publication 1756-TD005G-EN-E - June 2017 7
1756 ControlLogix Power Supplies Specifications
1756 ControlLogix-XT Power Supplies
The ControlLogix-XT products include control and communication system components that, when used with
FLEX I/O-XT products, provide a complete control system solution that you can use in environments where
temperatures range from -20+70 C (-4+158 F).
When used independently, the ControlLogix-XT system can withstand environments where the temperature ranges
from -25+70 C (-13+158 F).
Mounting Dimensions
1756-PAXT and 1756-PBXT 1756-PA30XT and 1756-PB30XT
14.0 14.0
(5.51) (5.51)
11.2
7.8
(4.41)
(3.07)
Dimensions are in cm (in.).
Technical Specifications - ControlLogix-XT Power Supplies
Attribute 1756-PAXT 1756-PA30XT 1756-PBXT 1756-PB30XT
(1)
Input voltage range 85265V AC 1832V DC 1832V DC(3)
Input voltage, nom 120/240V AC 24V DC
Input frequency range 4763 Hz
Input power, max 82VA 64 W 60VA 50 W 70 W 50 W
Output power, max 42 W @ -25+70 C 30 W @ -25+70 C 52 W @ -25+70 C 30 W @ -25+70 C
(-13+158 F) (-13+158 F) (-13+158 F) (-13+158 F)
Inrush current, max 20 A 30 A
Current capacity @ 1.2V 1.5 A
Current capacity @3.3V 4A 2A 4A 2A
Current capacity @ 5.1V 8A 6A 10 A 6A
Current capacity @ 24V 1.75 A 1.25 A 2.1 A 1.25 A
Isolation voltage 250V (continuous), 250V (continuous), 250V (continuous), 250V (continuous),
Reinforced Insulation Type, Reinforced Insulation Type, Reinforced Insulation Type, Reinforced Insulation Type,
Power Input to Backplane Power Input to Backplane Power Input to Backplane Power Input to Backplane
Type tested @ 3260V DC for Type tested @ 3150V DC for Type tested @ 3260V DC for Type tested @ 3150V DC for
60 s 60 s 60 s 60 s
Weight, approx 0.95 kg (2.10 lb) 0.77 kg (1.7 lb) 0.95 kg (2.10 lb) 0.77 kg (1.7 lb)
Dimensions (HxWxD), approx 14.0 x 11.2 x 14.5 cm 14.0 x 7.8 x 14.5 cm 14.0 x 11.2 x 14.5 cm 14.0 x 7.8 x 14.5 cm
(5.51 x 4.41 x 5.71 in.) (5.51 x 3.07 x 5.71 in.) (5.51 x 4.41 x 5.71 in.) (5.51 x 3.07 x 5.71 in.)
Module location Left side of 1756 chassis
8 Rockwell Automation Publication 1756-TD005G-EN-E - June 2017
1756 ControlLogix Power Supplies Specifications
Technical Specifications - ControlLogix-XT Power Supplies
Attribute 1756-PAXT 1756-PA30XT 1756-PBXT 1756-PB30XT
Chassis 1756-A4LXT/B, 1756-A5XT/B, 1756-A7LXT/B, 1756-A7XT/B, 1756-A7XT/C, 1756-A10XT/C
Wire size 2.5 mm2 (14 AWG) solid or stranded copper wire rated at 90 C (194 F), or greater, 1.2 mm (3/64 in.) insulation, max
Wire category 1 - on power ports(2)
Conductor screw torque 0.8 Nm (7 lbin)
North American temperature code T4 T4 T4A T4
ATEX temperature code T4
IEC temperature code T4
Enclosure type rating None (open-style)
(1) UL certification for 120/240V AC, 50/60 Hz nominal. Rockwell Automation specified 85265V AC, 4763 Hz.
(2) Use this conductor category information to plan conductor routing as described in the system level installation manual. See the Industrial Automation Wiring and Grounding Guidelines, publication 1770-4.1.
(3) UL certification for 24V DC nominal. Rockwell Automation specified 1832V DC.
Environmental Specifications - ControlLogix-XT Power Supplies
Attribute 1756-PAXT 1756-PA30XT 1756-PBXT 1756-PB30XT
Temperature, operating -25 C < Ta < +70 C (-13 F < Ta < +158 F)
IEC 60068-2-1 (Test Ad, Operating Cold),
IEC 60068-2-2 (Test Bd, Operating Dry
Heat),
IEC 60068-2-14 (Test Nb, Operating
Thermal Shock)
Temperature, surrounding air, max 70 C 158 F)
Temperature, nonoperating -40+85 C (-40+185 F)
IEC 60068-2-1 (Test Ab, Unpackaged
Nonoperating Cold),
IEC 60068-2-2 (Test Bb, Unpackaged
Nonoperating Dry Heat),
IEC 60068-2-14 (Test Na, Unpackaged
Nonoperating Thermal Shock)
Relative humidity 595% noncondensing
IEC 60068-2-30 (Test Db, Unpackaged
Damp Heat)
Vibration 2 g @ 10500 Hz
IEC 60068-2-6 (Test Fc, Operating)
Shock, operating 30 g
IEC 60068-2-27 (Test Ea, Unpackaged
Shock)
Shock, nonoperating 50 g(1)
IEC 60068-2-27 (Test Ea, Unpackaged
Shock)
Emissions IEC 61000-6-4
ESD immunity 6 kV contact discharges
IEC 61000-4-2 8 kV air discharges
Radiated RF immunity 10V/m with 1 kHz sine-wave 80% AM from 802000 MHz
IEC 61000-4-3 10V/m with 200 Hz 50% Pulse 100% AM at 900 MHz
10V/m with 200 Hz 50% Pulse 100% AM at 1890 MHz
3V/m with 1 kHz sine-wave 80% AM from 20002700 MHz
EFT/B immunity 4 kV at 5 kHz on power ports
IEC 61000-4-4
Surge transient immunity 1 kV line-line (DM) and 2 kV line-earth (CM) on power ports
IEC 61000-4-5
Conducted RF immunity 10V rms with 1 kHz sine-wave 80% AM from 150 kHz80 MHz
IEC 61000-4-6
Rockwell Automation Publication 1756-TD005G-EN-E - June 2017 9
1756 ControlLogix Power Supplies Specifications
Environmental Specifications - ControlLogix-XT Power Supplies
Attribute 1756-PAXT 1756-PA30XT 1756-PBXT 1756-PB30XT
Voltage variation 30% dips for 1 period at 0 and 180 on AC supply ports
IEC 61000-4-11 60% dips for 5 and 50 periods on AC supply ports
10% fluctuations for 15 min on AC supply ports
>95% interruptions for 250 periods on AC supply ports
Voltage variation 10 ms interruption on DC supply ports(2)
IEC 61000-4-29 60% dips for 100 ms on DC supply ports
100% dips for 50 ms on DC supply ports
20% fluctuations for 15 min on DC supply ports
5 s interruptions on DC supply ports(3)
Damped oscillatory wave immunity 2.5 kV line-line (DM) and 2.5 kV 2.5 kV line-line (DM) and 2.5 kV
IEC 61000-4-18 line-earth (CM) on power ports line-earth (CM) on power ports
(1) Series C chassis have a maximum nonoperating shock value of 30 g. If you select a Series C chassis for use with your power supply, you are limited to a maximum nonoperating shock value of 30 g.
(2) Short interruption test verifies ride through. The supply remains fully functional under this condition.
(3) Long interruption test verifies that repetitive inrush surge currents do not create any unsafe conditions. The supply fully shuts down and starts up in this test.
Certifications - ControlLogix-XT Power Supplies
Certification(1) 1756-PAXT 1756-PA30XT 1756-PBXT 1756-PB30XT
c-UL-us UL Listed Industrial Control Equipment, certified for US and Canada. See UL File E65584.
UL Listed for Class I, Division 2 Group A,B,C,D Hazardous Locations, certified for US and Canada. See UL File E194810.
CE European Union 2014/30/EU EMC European Union 2014/30/EU EMC European Union 2014/30/EU EMC European Union 2014/30/EU EMC
Directive, compliant with: Directive, compliant with: Directive, compliant with: Directive, compliant with:
EN 61326-1; Meas./Control/Lab., EN 61326-1; Meas./Control/Lab., EN 61326-1; Meas./Control/Lab., EN 61326-1; Meas./Control/Lab.,
Industrial Requirements Industrial Requirements Industrial Requirements Industrial Requirements
EN 61000-6-2; Industrial Immunity EN 61000-6-2; Industrial Immunity EN 61000-6-2; Industrial Immunity EN 61000-6-2; Industrial Immunity
EN 61000-6-4; Industrial Emissions EN 61000-6-4; Industrial Emissions EN 61000-6-4; Industrial Emissions EN 61000-6-4; Industrial Emissions
EN 61131-2; Programmable Controllers EN 61131-2; Programmable Controllers EN 61131-2; Programmable Controllers EN 61131-2; Programmable Controllers
(Clause 8, Zone A & B) (Clause 8, Zone A & B) (Clause 8, Zone A & B) (Clause 8, Zone A & B)
European Union 2014/35/EU LVD, European Union 2014/35/EU LVD, European Union 2014/35/EU LVD, European Union 2014/35/EU LVD,
compliant with: compliant with: compliant with: compliant with:
EN 61131-2; Programmable Controllers EN 61010-2-201; Control Equipment EN 61131-2; Programmable Controllers EN 61010-2-201; Control Equipment
(Clause 11) Safety Requirements (Clause 11) Safety Requirements
RCM Australian Radiocommunications Act, compliant with:
EN 61000-6-4; Industrial Emissions
Ex European Union 2014/34/EU ATEX Directive, compliant with:
EN 60079-0; General Requirements
EN 60079-15; Potentially Explosive Atmospheres, Protection "n"
II 3 G Ex nA IIC T4 Gc X
DEMKO13ATEX1325026X
IECEx IECEx System, compliant with:
IEC 60079-0; General Requirements
IEC 60079-15; Potentially Explosive Atmospheres, Protection "n"
II 3 G Ex nA IIC T4 Gc
IECEx UL 14.0008X
KC Korean Registration of Broadcasting and Communications Equipment, compliant with:
Article 58-2 of Radio Waves Act, Clause 3
EAC Russian Customs Union TR CU 020/2011 EMC Technical Regulation
Russian Customs Union TR CU 004/2011 LV Technical Regulation
(1) When marked. See the Product Certification link at http://www.ab.com for Declarations of Conformity, Certificates, and other certification details.
10 Rockwell Automation Publication 1756-TD005G-EN-E - June 2017
1756 ControlLogix Power Supplies Specifications
Redundant Power Supplies
To build a redundant power supply system, you need the following.
Cat. No. Description Amount
1756-PA75R/A, 1756-PAXTR, Redundant power supply 2
1756-PB75R/A, or 1756-PBXTR
1756-CPR2(1) Redundant power supply cable (Length = 0.9 1m [3 ft]) 2
1756-CPR2D(2) or
1756-CPR2U(2)
1756-PSCA2 or 1756-PSCA2XT Redundant power supply chassis adapter(3) 1
(4)
User-supplied Annunciator wiring (Length, max = 10 m [32.8 ft]) 2
(1) Cable bend radius is 12.7 cm (5.0 in.).
(2) Requires 10.16 cm (4.0 in.) of clearance next to the chassis adapter.
(3) The 1756-PSCA2 or 1756-PSCA-2XT chassis adapter is a passive device. The adapter funnels power from the redundant power supplies to the single power connector
on the ControlLogix series B chassis backplane.
(4) Optional user-provided annunciator wiring can be connected to the solid-state relay for status and troubleshooting.
System Configuration Recommendations
We recommend that you use one of these methods to configure your redundant power supply system.
Recommended Configurations for a System That Uses One Chassis
Recommended Configurations for a System That Uses Two Chassis
Rockwell Automation Publication 1756-TD005G-EN-E - June 2017 11
1756 ControlLogix Power Supplies Specifications
Mounting Dimensions
7.0
(2.76)
Top Mounting Bottom Mounting
Hole Diameter Hole Diameter
0.55
(0.217)
1.1
(0.433)
15.8 17.5
(6.22) (6.88)
14.4
(5.66)
Dimensions are in cm (in.).
Redundant Power Supply Features
The redundant power supplies offer the same features as the standard power supplies, and the following:
Redundant operation
Automatic chassis load sharing between the redundant power supplies
Status indicators for visual operating status of the pair
Solid-state relay for system recognition of supply status when wired to an input module
The ControlLogix redundant power supply system is designed to account for operational anomalies in only the
power supply (the chassis adapter and power supply cables are excluded)
Technical Specifications - ControlLogix Redundant Power Supplies
Attribute 1756-PA75R 1756-PB75R
Input voltage range 85265V AC(1) 1832V DC(2)
Input voltage 120V/240V AC, 50/60 Hz 24V DC
Input frequency range 4763 Hz
Input power, max 120VA 115 W 110 W
Output power, max 75 W @ 060 C (32140 F)
Inrush current, max 20 A 30 A
Hold up time(3) 2 cycles @ 60 Hz 20 ms
2 cycles @ 50 Hz
Current capacity @ 1.2V 1.5 A
Current capacity @ 3.3V 4A
Current capacity @ 5.1V 13 A
Current capacity @ 24V 2.8 A
Annunciator power 240V AC 50/60 Hz, 240V DC, 50 mA, resistive only 90V DC for ATEX/IECEx
Isolation voltage 250V (continuous), Reinforced Insulation Type, Power Input to Backplane, Power Input to Annunciator, Annunciator to Backplane
Type tested at 3250V DC for 60 s
12 Rockwell Automation Publication 1756-TD005G-EN-E - June 2017
1756 ControlLogix Power Supplies Specifications
Technical Specifications - ControlLogix Redundant Power Supplies
Attribute 1756-PA75R 1756-PB75R
Dimensions (HxWxD), approx 17.5 x 14.5 x 13.7 cm (6.9 x 5.7 x 5.4 in.)
Weight, approx 1.45 kg (3.2 lb)
Chassis 1756-A4, 1756-A7, 1756-A10, 1756-A13, 1756-A17
Wire size Power:
2.5 mm2 (14 AWG) solid or stranded copper wire rated at 90 C (194 F), or greater, 1.2 mm (3/64 in.) insulation max
Annunciator:
0.252.5 mm2 (2214 AWG) solid or stranded copper wire rated at 90 C (194 F), or greater, 1.2 mm (3/64 in.) insulation max
Wire category (4) 3 - on annunciator ports
1 - on power ports
3 - on 1756-CPR2 connections
Pilot duty rating Annunciator - not rated
Conductor screw torque 0.79 Nm (7 lbin)
North American temperature code T3C T4
ATEX temperature code T4
IEC temperature code T4
Enclosure type rating None (open-style)
(1) UL certification for 120/240V AC, 50/60 Hz nominal. Rockwell Automation specified 85265V AC, 4763 Hz.
(2) UL certification for 24V DC nominal. Rockwell Automation specified 1832V DC.
(3) The hold up time is the time between input voltage removal and DC power failure.
(4) Use this conductor category information to plan conductor routing. See the Industrial Automation Wiring and Grounding Guidelines, publication 1770-4.1.
Environmental Specifications - Redundant Power Supplies
Attribute 1756-PA75R 1756-PB75R
Temperature, operating 060 C (32140 F)
IEC 60068-2-1 (Test Ad, Operating Cold),
IEC 60068-2-2 (Test Bd, Operating Dry Heat),
IEC 60068-2-14 (Test Nb, Operating Thermal Shock)
Temperature, surrounding air, max 60 C 140 F)
Temperature, nonoperating -40+85 C (-40+185 F)
IEC 60068-2-1 (Test Ab, Unpackaged Nonoperating Cold),
IEC 60068-2-2 (Test Bb, Unpackaged Nonoperating Dry Heat),
IEC 60068-2-14 (Test Na, Unpackaged Nonoperating Thermal
Shock)
Relative humidity 595% noncondensing
IEC 60068-2-30 (Test Db, Unpackaged Damp Heat)
Vibration 2 g @ 10500 Hz
IEC 60068-2-6 (Test Fc, Operating)
Shock, operating 30 g
IEC 60068-2-27 (Test Ea, Unpackaged Shock)
Shock, nonoperating 50 g
IEC 60068-2-27 (Test Ea, Unpackaged Shock)
Emissions IEC 61000-6-4
ESD immunity 6 kV contact discharges
IEC 61000-4-2 8 kV air discharges
Radiated RF immunity 10V/m with 1 kHz sine-wave 80% AM from 802000 MHz
IEC 61000-4-3 10V/m with 200 Hz 50% Pulse 100% AM @ 900 MHz
10V/m with 200 Hz 50% Pulse 100% AM at 1890 MHz
3V/m with 1 kHz sine-wave 80% AM from 20002700 MHz
EFT/B immunity 4 kV at 5 kHz on power ports
IEC 61000-4-4 4 kV at 5 kHz on annunciator ports
Surge transient immunity 1 kV line-line (DM) and 2 kV line-earth (CM) on power ports
IEC 61000-4-5
Rockwell Automation Publication 1756-TD005G-EN-E - June 2017 13
1756 ControlLogix Power Supplies Specifications
Environmental Specifications - Redundant Power Supplies
Attribute 1756-PA75R 1756-PB75R
Conducted RF immunity 15V rms with 1 kHz sine-wave 80% AM from 150 kHz80 MHz
IEC 61000-4-6
Conducted audio immunity 2 W max from rated frequency to the 200th harmonic on AC supply ports
IEC 945
Voltage variation 30% dips for 1 period at 0 and 180 on AC supply ports
IEC 61000-4-11 60% dips for 5 and 50 periods on AC supply ports
10% fluctuations for 15 min on AC supply ports
>95% interruptions for 250 periods on AC supply ports
Voltage variation 10 ms interruption on DC supply ports(1)
IEC 61000-4-29 60% dips for 100 ms on DC supply ports
100% dips for 50 ms on DC supply ports
20% fluctuations for 15 min on DC supply ports
5 s interruptions on DC supply ports(2)
(1) Short interruption test verifies ride through. The supply remains fully functional under this condition.
(2) Long interruption test verifies that repetitive inrush surge currents do not create any unsafe conditions. The supply fully shuts down and starts up in this test.
Certifications - Redundant Power Supplies
Certification(1) 1756-PA75R 1756-PB75R
c-UL-us UL Listed Industrial Control Equipment, certified for US and Canada. See UL File E65584.
UL Listed for Class I, Division 2 Group A,B,C,D Hazardous Locations, certified for U.S. and Canada. See UL File E194810.
CSA CSA Certified Process Control Equipment. See CSA File LR54689C.
CSA Certified Process Control Equipment for Class I, Division 2 Group A,B,C,D Hazardous Locations. See CSA File LR69960C.
FM FM Approved Equipment for use in Class I Division 2 Group A,B,C,D Hazardous Locations
CE European Union 2014/30/EU EMC Directive, compliant with:
EN 61326-1; Meas./Control/Lab., Industrial Requirements
EN 61000-6-2; Industrial Immunity
EN 61000-6-4; Industrial Emissions
EN 61131-2; Programmable Controllers (Clause 8, Zone A & B)
European Union 2014/35/EU LVD, compliant with:
EN 61131-2; Programmable Controllers (Clause 11)
RCM Australian Radiocommunications Act, compliant with:
EN 61000-6-4; Industrial Emissions
Ex European Union 2014/34/EU ATEX Directive, compliant with:
EN 60079-0; General Requirements
EN 60079-15; Potentially Explosive Atmospheres, Protection "n"
II 3 G Ex nA IIC T4 Gc
DEMKO13ATEX1325026X
IECEx IECEx System, compliant with:
IEC 60079-0; General Requirements
IEC 60079-15; Potentially Explosive Atmospheres, Protection "n"
II 3 G Ex nA IIC T4 Gc
IECEx UL 14.0008X
KC Korean Registration of Broadcasting and Communications Equipment, compliant with:
Article 58-2 of Radio Waves Act, Clause 3
EAC Russian Customs Union TR CU 020/2011 EMC Technical Regulation
Russian Customs Union TR CU 004/2011 LV Technical Regulation
(1) When marked. See the Product Certification link at http://www.ab.com for Declarations of Conformity, Certificates, and other certification details.
Technical Specifications - ControlLogix-XT Redundant Power Supplies
Attribute 1756-PAXTR 1756-PBXTR
Input voltage range 85265V AC(1) 1832V DC
Input voltage 120V/240V AC 24V DC
Input frequency range 4763 Hz
Input power, max 75VA 65 W 81 W
14 Rockwell Automation Publication 1756-TD005G-EN-E - June 2017
1756 ControlLogix Power Supplies Specifications
Technical Specifications - ControlLogix-XT Redundant Power Supplies
Attribute 1756-PAXTR 1756-PBXTR
Output power, max 42 W @ 060 C (32140 F) 52 W
Inrush current, max 20 A 30 A
Current capacity @ 1.2V 1.5 A
Current capacity @ 3.3V 4A
Current capacity @ 5.1V 8A 10 A
Current capacity @ 24V 1.75 A 2.1 A
Annunciator power 240V AC 50/60 Hz, 240V DC, 50 mA, resistive only 240V AC 50/60 Hz, 240V DC, 50 mA, resistive only
90V DC for ATEX/IECEx
Isolation voltage 250V (continuous), Reinforced Insulation Type, Power Input to Backplane, Power Input to Annunciator, Annunciator to Backplane
Type tested at 3250V DC for 60 s
Dimensions (HxWxD), approx 17.5 x 14.5 x 13.7 cm (6.9 x 5.7 x 5.4 in.)
Weight, approx 1.45 kg (3.2 lb)
Chassis 1756-A4/B, 1756-A7/B, 1756-A10/B, 1756-A13/B, 1756-A17/B, 1756-A4LXT/B, 1756-A5XT/B, 1756-A7LXT/B, 1756-A7XT/B
1756-A4/C, 1756-A7/C, 1756-A10/C, 1756-A13/C, 1756-A17/C, 1756-A7XT/C
Wire size Power:
2.5 mm2 (14 AWG) solid or stranded copper wire rated at 90 C (194 F), or greater, 1.2 mm (3/64 in.) insulation max
Annunciator:
0.252.5 mm2 (2214 AWG) solid or stranded copper wire rated at 90 C (194 F), or greater, 1.2 mm (3/64 in.) insulation max
Wire category (2) 1 - on power ports
3 - on annunciator ports
3 - on 1756-CPR2 connections
Pilot duty rating Annunciator - not rated
Conductor screw torque 0.79 Nm (7 lbin)
North American temperature code T4A
ATEX temperature code T4
IEC temperature code T4
Enclosure type rating None (open-style)
(1) UL certification for 120/240V AC, 50/60 Hz nominal. Rockwell Automation specified 85265V AC, 4763 Hz.
(2) Use this conductor category information to plan conductor routing. See Industrial Automation Wiring and Grounding Guidelines, publication 1770-4.1.
Environmental Specifications - XT Redundant Power Supplies
Attribute 1756-PAXTR 1756-PBXTR
Temperature, operating -25+70 C (13+158 F)
IEC 60068-2-1 (Test Ad, Operating Cold),
IEC 60068-2-2 (Test Bd, Operating Dry Heat),
IEC 60068-2-14 (Test Nb, Operating Thermal Shock)
Temperature, surrounding air, max 70 C (158 F)
Temperature, nonoperating -40+85 C (-40+185 F)
IEC 60068-2-1 (Test Ab, Unpackaged Nonoperating Cold),
IEC 60068-2-2 (Test Bb, Unpackaged Nonoperating Dry Heat),
IEC 60068-2-14 (Test Na, Unpackaged Nonoperating Thermal
Shock)
Relative humidity 595% noncondensing
IEC 60068-2-30 (Test Db, Unpackaged Damp Heat)
Vibration 2 g @ 10500 Hz
IEC 60068-2-6 (Test Fc, Operating)
Shock, operating 30 g
IEC 60068-2-27 (Test Ea, Unpackaged Shock)
Shock, nonoperating 50 g
IEC 60068-2-27 (Test Ea, Unpackaged Shock)
Rockwell Automation Publication 1756-TD005G-EN-E - June 2017 15
1756 ControlLogix Power Supplies Specifications
Environmental Specifications - XT Redundant Power Supplies
Attribute 1756-PAXTR 1756-PBXTR
Emissions IEC 61000-6-4
ESD immunity 6 kV contact discharges
IEC 61000-4-2 8 kV air discharges
Radiated RF immunity 10V/m with 1 kHz sine-wave 80% AM from 802000 MHz
IEC 61000-4-3 10V/m with 200 Hz 50% Pulse 100% AM @ 900 MHz
10V/m with 200 Hz 50% Pulse 100% AM at 1890 MHz
3V/m with 1 kHz sine-wave 80% AM from 20002700 MHz
EFT/B immunity 4 kV at 5 kHz on power ports
IEC 61000-4-4 4 kV at 5 kHz on annunciator ports
Surge transient immunity 1 kV line-line (DM) and 2 kV line-earth (CM) on power ports
IEC 61000-4-5
Conducted RF immunity 15V rms with 1 kHz sine-wave 80% AM from 10V rms with 1 kHz sine-wave 80% AM from
IEC 61000-4-6 150 kHz80 MHz 150 kHz80 MHz
Conducted audio immunity 2 W max from rated frequency to the 200th harmonic on AC supply ports
IEC 945
Voltage variation 30% dips for 1 period at 0 and 180 on AC supply ports
IEC 61000-4-11 60% dips for 5 and 50 periods on AC supply ports
10% fluctuations for 15 min on AC supply ports
>95% interruptions for 250 periods on AC supply ports
Voltage variation 10 ms interruption on DC supply ports(1)
IEC 61000-4-29 60% dips for 100 ms on DC supply ports
100% dips for 50 ms on DC supply ports
20% fluctuations for 15 min on DC supply ports
5 s interruptions on DC supply ports(2)
(1) Short interruption test verifies ride through. The supply remains fully functional under this condition.
(2) Long interruption test verifies that repetitive inrush surge currents do not create any unsafe conditions. The supply fully shuts down and starts up in this test.
Certifications - XT Redundant Power Supplies
Certification(1) 1756-PAXTR 1756-PBXTR
c-UL-us UL Listed Industrial Control Equipment, certified for US and Canada. See UL File E65584.
UL Listed for Class I, Division 2 Group A,B,C,D Hazardous Locations, certified for U.S. and Canada. See UL File E194810.
CE European Union 2014/30/EU EMC Directive, compliant with:
EN 61326-1; Meas./Control/Lab., Industrial Requirements
EN 61000-6-2; Industrial Immunity
EN 61000-6-4; Industrial Emissions
EN 61131-2; Programmable Controllers (Clause 8, Zone A & B)
European Union 2014/35/EU LVD, compliant with:
EN 61131-2; Programmable Controllers (Clause 11)
RCM Australian Radiocommunications Act, compliant with:
EN 61000-6-4; Industrial Emissions
Ex European Union 2014/34/EU ATEX Directive, compliant with:
EN 60079-0; General Requirements
EN 60079-15; Potentially Explosive Atmospheres, Protection
"n"
II 3 G Ex nA IIC T4 Gc
DEMKO13ATEX1325026X
IECEx IECEx System, compliant with:
IEC 60079-0; General Requirements
IEC 60079-15; Potentially Explosive Atmospheres, Protection
"n"
II 3 G Ex nA IIC T4 Gc
IECEx UL 14.0008X
KC Korean Registration of Broadcasting and Communications Equipment, compliant with:
Article 58-2 of Radio Waves Act, Clause 3
EAC Russian Customs Union TR CU 020/2011 EMC Technical Regulation
Russian Customs Union TR CU 004/2011 LV Technical Regulation
(1) When marked. See the Product Certification link at http://www.ab.com for Declarations of Conformity, Certificates, and other certification details.
16 Rockwell Automation Publication 1756-TD005G-EN-E - June 2017
1756 ControlLogix Power Supplies Specifications
Redundant Power Supply Chassis Adapter
Technical Specifications - Redundant Power Supplies Chassis Adapter
Attribute 1756-PSCA2 1756-PSCA2XT
Current capacity @ 1.2V DC 1.5 A
Current capacity @ 3.3V DC 4A
Current capacity @ 5.1V DC 15 A
Current capacity @ 24V DC 2.8 A
Wire category (1) 3 - on 1756-CPR2 connections
North American temperature code T5 T4A
ATEX temperature code T4
IEC temperature code T4
Enclosure type rating None (open-style)
(1) Use this conductor category information to plan conductor routing. See the Industrial Automation Wiring and Grounding Guidelines, publication 1770-4.1.
Environmental Specifications - Redundant Power Supplies Chassis Adapter
Attribute 1756-PSCA2 1756-PSCA2XT
Temperature, operating 060 C (32140 F) -25+70 C (-13+158 F)
IEC 60068-2-1 (Test Ad, Operating Cold),
IEC 60068-2-2 (Test Bd, Operating Dry Heat),
IEC 60068-2-14 (Test Nb, Operating Thermal Shock)
Temperature, surrounding air, max 60 C (140 F) 70 C (158 F)
Temperature, nonoperating -40+85 C (-40+185 F)
IEC 60068-2-1 (Test Ab, Unpackaged Nonoperating Cold),
IEC 60068-2-2 (Test Bb, Unpackaged Nonoperating Dry Heat),
IEC 60068-2-14 (Test Na, Unpackaged Nonoperating Thermal Shock)
Relative humidity 595% noncondensing
IEC 60068-2-30 (Test Db, Unpackaged Damp Heat)
Vibration 2 g @ 10500 Hz
IEC 60068-2-6 (Test Fc, Operating)
Shock, operating 30 g
IEC 60068-2-27 (Test Ea, Unpackaged Shock)
Shock, nonoperating 50 g
IEC 60068-2-27 (Test Ea, Unpackaged Shock)
Emissions IEC 61000-6-4
ESD immunity 6 kV contact discharges
IEC 61000-4-2 8 kV air discharges
Radiated RF immunity 10V/m with 1 kHz sine-wave 80% AM from 802000 MHz
IEC 61000-4-3 10V/m with 200 Hz 50% Pulse 100% AM at 900 MHz
10V/m with 200 Hz 50% Pulse 100% AM at 1890 MHz
3V/m with 1 kHz sine-wave 80% AM from 20002700 MHz
Rockwell Automation Publication 1756-TD005G-EN-E - June 2017 17
1756 ControlLogix Power Supplies Specifications
Certifications - Redundant Power Supplies Chassis Adapter
Certification(1) 1756-PSCA2 1756-PSCA2XT
c-UL-us UL Listed Industrial Control Equipment, certified for US and Canada. See UL File E65584.
UL Listed for Class I, Division 2 Group A,B,C,D Hazardous Locations, certified for U.S. and Canada. See UL File E194810.
CSA CSA Certified Process Control Equipment. See CSA File
LR54689C.
CSA Certified Process Control Equipment for Class I, Division 2
Group A,B,C,D Hazardous Locations. See CSA File LR69960C.
FM FM Approved Equipment for use in Class I Division 2 Group
A,B,C,D Hazardous Locations
CE European Union 2014/30/EU EMC Directive, compliant with:
EN 61326-1; Meas./Control/Lab., Industrial Requirements
EN 61000-6-2; Industrial Immunity
EN 61000-6-4; Industrial Emissions
EN 61131-2; Programmable Controllers (Clause 8, Zone A & B)
RCM Australian Radiocommunications Act, compliant with:
EN 61000-6-4; Industrial Emissions
Ex European Union 2014/34/EU ATEX Directive, compliant with: European Union 2014/34/EU ATEX Directive, compliant with:
EN 60079-0; General Requirements EN 60079-0; General Requirements
EN 60079-15; Potentially Explosive Atmospheres, Protection EN 60079-15; Potentially Explosive Atmospheres, Protection
"n" "n"
II 3 G Ex nA IIC T4 Gc II 3 G Ex nA IIC T4 Gc
DEMKO13ATEX1325026X DEMKO13ATEX1325026X
IECEx IECEx System, compliant with: IECEx System, compliant with:
IEC 60079-0; General Requirements IEC 60079-0; General Requirements
IEC 60079-15; Potentially Explosive Atmospheres, Protection IEC 60079-15; Potentially Explosive Atmospheres, Protection
"n" "n"
II 3 G Ex nA IIC T4 Gc II 3 G Ex nA IIC T4 Gc
IECEx UL 14.0008X IECEx UL 14.0008X
KC Korean Registration of Broadcasting and Communications Equipment, compliant with:
Article 58-2 of Radio Waves Act, Clause 3
EAC Russian Customs Union TR CU 020/2011 EMC Technical Regulation
Russian Customs Union TR CU 004/2011 LV Technical Regulation
(1) When marked. See the Product Certification link at http://www.ab.com for Declarations of Conformity, Certificates, and other certification details.
Power Load and Transformer Sizing
The following graphs show the input power requirements for the power supplies, given the power that they are providing
to the modules in the chassis.
Follow these steps to determine the power requirements for your chassis.
1. Calculate the Backplane Power Load by adding the power draw (in watts) for all planned modules.
For module power draws, refer to the module specification tables in the ControlLogix Selection Guide,
publication 1756-SG001.
2. Locate the Backplane Power Load on the vertical (y) axis of the graph and determine the corresponding Real
Power (input-power) rating on the horizontal (x) axis.
The Real Power value is the amount of power that is consumed by the power supply.
18 Rockwell Automation Publication 1756-TD005G-EN-E - June 2017
1756 ControlLogix Power Supplies Specifications
Standard Power Supply Power Requirements
1756-PA72/C, 1756-PA75/B (AC) 1756-PBXT (DC)
56 70
100
75 49
60 42
Backplane Power 45 35
Load (Watts) 30 Backplane Power 28
15 Load (Watts) 21
6 14
0
7
4
0 20 40 60 80 100 120 0
Real Power (Watts) 0 10 20 30 40 50 60 70
Real Power (Watts)
1756-PB72/C, 1756-PB75/B (DC)
75 95 1756-PBXTR (DC)
56
60 49
81
Backplane Power 45
Backplane Power
42
Load (Watts) 30
Load (Watts)
35
15 28
0 4 21
0 20 40 60 80 100 120 14
Real Power (Watts) 7
6
0
0 10 20 30 40 50 60 70 80 90
1756-PH75/B, 1756-PC75/B (DC) Real Power (Watts)
95
75
1756-PA75R/A (AC)
60
Backplane Power 45 115
75
Load (Watts) 30 60
15 Backplane Power 45
4 Load (Watts) 30
0
15
0 20 40 60 80 100 120 13
0
Real Power (Watts) 0 20 40 60 80 100 120
Real Power (Watts)
1756-PAXT (AC)
64
42 1756-PB75R/A (DC)
35 110
75
28
60
Backplane Power 21 Backplane Power 45
Load (Watts) 14 Load (Watts) 30
7 15
6 7
0 0
0 10 20 30 40 50 60 70 0 20 40 60 80 100 120
Real Power (Watts) Real Power (Watts)
1756-PAXTR (AC)
75
42
35
28
Backplane Power 21
Load (Watts) 14
7
8
0
0 10 20 30 40 50 60 70 80
Real Power (Watts) Apparent Power (Watts) = Transformer Load (VA) = Real Power (Watts)
Rockwell Automation Publication 1756-TD005G-EN-E - June 2017 19
1756 ControlLogix Power Supplies Specifications
Slim Power Supply Power Requirements
1756-PA50 @ 50 C (AC) 1756-PA30XT (AC)
82 45
60 30
50 25
Backplane Power 40 Backplane Power 20
Load (Watts) 30 15
Load (Watts)
20 10
10 5
6 6
0 0
0 10 20 30 40 50 60 70 80 90 0 5 10 15 20 25 30 35 40 45 50
Real Power (Watts) Real Power (Watts)
1756-PA50 @ 60 C (AC) 1756-PB30XT (DC)
41
70 30
50
40 Backplane Power
Backplane Power 20
30
Load (Watts) 20
Load (Watts)
10
10
6
0 4
0
0 10 20 30 40 50 60 70 80
0 5 10 15 20 25 30 35 40 45
Real Power (Watts) Real Power (Watts)
1756-PB50 @ 50 C (DC)
78
60
50
Backplane Power 40
Load (Watts) 30
20
10
4
0
0 10 20 30 40 50 60 70 80 90
Real Power (Watts)
1756-PB50 @ 60 C (DC)
66
50
40
Backplane Power 30
Load (Watts) 20
10
4
0
0 10 20 30 40 50 60 70 80
Apparent Power (Watts) = Transformer Load (VA) = Real Power (Watts)
Real Power (Watts)
20 Rockwell Automation Publication 1756-TD005G-EN-E - June 2017
1756 ControlLogix Power Supplies Specifications
Additional Resources
These documents contain additional information concerning related products from Rockwell Automation.
Resource Description
ControlLogix Chassis Specifications Technical Data, publication 1756-TD006 Provides technical specifications for ControlLogix chassis.
ControlLogix Selection Guide, publication 1756-SG001 Provides overview of the ControlLogix system and its products.
ControlLogix Power Supply Installation Instructions, publication 1756-IN619 Provides information on how to install ControlLogix standard power supplies.
ControlLogix Redundant Power Supply Installation Instructions, publication 1756-IN620 Provides information on how to install ControlLogix redundant power supplies.
ControlLogix Chassis Installation Instructions, publication 1756-IN621 Provides information on how to install ControlLogix chassis.
ControlLogix System User Manual, publication 1756-UM001 Provides information on how to install, configure, program, and use ControlLogix
systems.
Industrial Automation Wiring and Grounding Guidelines, publication 1770.4.1 Provides general guidelines for installing a Rockwell Automation industrial system.
Product Certifications website, Provides declarations of conformity, certificates, and other certification details.
http://www.rockwellautomation.com/global/certification/overview.page
You can view or download publications at http://www.rockwellautomation.com/literature/. To order paper copies of
technical documentation, contact your local Allen-Bradley distributor or Rockwell Automation sales representative.
Rockwell Automation Publication 1756-TD005G-EN-E - June 2017 21
1756 ControlLogix Power Supplies Specifications
Notes:
22 Rockwell Automation Publication 1756-TD005G-EN-E - June 2017
1756 ControlLogix Power Supplies Specifications
Notes:
Rockwell Automation Publication 1756-TD005G-EN-E - June 2017 23
Rockwell Automation Support
Use the following resources to access support information.
Knowledgebase Articles, How-to Videos, FAQs, Chat, www.rockwellautomation.com/knowledgebase
Technical Support Center User Forums, and Product Notification Updates.
Locate the phone number for your country. www.rockwellautomation.com/global/support/get-support-
Local Technical Support Phone Numbers now.page
Find the Direct Dial Code for your product. Use the www.rockwellautomation.com/global/support/direct-
Direct Dial Codes code to route your call directly to a technical support dial.page
engineer.
Installation Instructions, Manuals, Brochures, and www.rockwellautomation.com/literature
Literature Library Technical Data.
Product Compatibility and Download Center Get help determining how products interact, check www.rockwellautomation.com/global/support/pcdc.page
features and capabilities, and find associated
(PCDC) firmware.
Documentation Feedback
Your comments will help us serve your documentation needs better. If you have any suggestions on how to improve this document, complete the
How Are We Doing? form at http://literature.rockwellautomation.com/idc/groups/literature/documents/du/ra-du002_-en-e.pdf.
Rockwell Automation maintains current product environmental information on its website at http://www.rockwellautomation.com/rockwellautomation/about-us/sustainability-ethics/product-environmental-compliance.page.
Allen-Bradley, ControlLogix, ControlLogix-XT, FLEX I/O-XT, LISTEN. THINK. SOLVE, Rockwell Automation, and Rockwell Software are trademarks of Rockwell Automation, Inc.
Trademarks not belonging to Rockwell Automation are property of their respective companies.
Rockwell Otomasyon Ticaret A.., Kar Plaza Merkezi E Blok Kat:6 34752 erenky, stanbul, Tel: +90 (216) 5698400
Publication 1756-TD005G-EN-E - June 2017
Supersedes Publication 1756-TD005F-EN-E - May 2016 Copyright 2017 Rockwell Automation, Inc. All rights reserved. Printed in the U.S.A.