Interface Basica DB25: 1 To Connect The PC Parallel Port by The Parallel Cable of The Priter

1. The document describes the basic DB25 interface for connecting a PC parallel port to a CNC system using a parallel cable. 2. It explains the power supply input port can be configured for single or dual power supplies and identifies the connections for power and ground. 3. The output connector has 12 wires for controlling 6 axes (X, Y, Z, A, B, C) with separate pins for pulses and directions. An additional connector is for small drivers. 4. It notes the input has 5 channels that can connect sensors and switches to realize functions programmed in software, such as mechanical or emergency switches.
Copyright
© © All Rights Reserved
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
18 views

Interface Basica DB25: 1 To Connect The PC Parallel Port by The Parallel Cable of The Priter

1. The document describes the basic DB25 interface for connecting a PC parallel port to a CNC system using a parallel cable. 2. It explains the power supply input port can be configured for single or dual power supplies and identifies the connections for power and ground. 3. The output connector has 12 wires for controlling 6 axes (X, Y, Z, A, B, C) with separate pins for pulses and directions. An additional connector is for small drivers. 4. It notes the input has 5 channels that can connect sensors and switches to realize functions programmed in software, such as mechanical or emergency switches.
Copyright
© © All Rights Reserved
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 3

www.TodoCNC.com.mx www.OXnetworks.

com

Interface Basica DB25

1 To connect the PC parallel port by the parallel cable of the priter,

2 The power supply input port, it can set up the single or double power supply
www.TodoCNC.com.mx www.OXnetworks.com
JN1&JN2 connected , which is the case of the single power .The +5Vand
isolating source(+) will be connected, the GND and the isolating source
(GND) will be connected. But if the JN1&JN2 is open circuit , the +5V and
the isolating source(+) will be cut off, the GND and the isolating source
(GND) will be cut off.

J4 is the isolating source(GND) and Isolating source(+)

3 Output connector, 12 wires OC( screw terminal output.)

P2 is for X axis pulse, P3 is for X aixs direction


P4 is for Y axis pulse, P5 is for Y axis direction
P6 is for Z axis pulse, P7 is for Z axis direction
Other 3 axis can be setting as
P8 is for A axis pulse, P9 is for A aixs direction
P14 is for B axis pulse,P1 is for B axis direction
P16 is for C axis pulse,and P17 is for C axis direction

J1 is the contact pin output, as the same as the terminal P2-P7, used
to connect the small driver.
www.TodoCNC.com.mx www.OXnetworks.com
4 The 5 channel input signal port can be connected to the external
mechanical switch, the proximity switch etc.

Through the P10-P15 , it can connect to the sensor and switch, and
it can realized the functions by setting up the software.
The connection of the mechanical / emergency switch..